Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(8): 083518, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050087

RESUMO

A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (Te) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (Te0) and density (ne0) is greater than 35 × 1019 keV m-3, which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.

2.
Rev Sci Instrum ; 92(8): 083509, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34470419

RESUMO

A solid state terahertz interferometer has been developed on the recent commissioned HL-2M tokamak. It can work in a wide frequency region of 220-325 GHz, and the terahertz wave is generated from a low frequency phase locked voltage controlled oscillator with the frequency multiplying technique. A phase processor based on field programmable gate array (FPGA) technology is designed for the heterodyne interferometer, and it contributes to real-time display of electron density. To extract phase information, a novel numerical algorithm related to fast Fourier transform is written on the FPGA chip and enables one to obtain phase shift without being affected by amplitude variation induced by plasma absorption or frequency modulation from the outer electromagnetic environment. The interferometer achieves minimum measurable electron density in the order of 1016 m-3. With the plasma diagnosis, electron density and low frequency tearing mode have been measured during the first experimental campaign.

3.
Rev Sci Instrum ; 92(6): 063513, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243534

RESUMO

Remote control of the diagnostic systems is the basic requirement for the high performance plasma operation in a fusion device. This work presents the development of the remote control system for the multichannel Doppler backward scattering (DBS) reflectometers. It includes a remote controlled quasi-optical system and a remote intermediate frequency (IF) amplifier gain control system. The quasi-optical system contains a rotational polarizer, its polarization angle is tunable through a remote controlled motor, and it could combine the microwave beams with a wide frequency range into one focused beam. The remote IF gain control system utilizes the digital microcontroller (MCU) technique to regulate the signal amplitude for each signal channel. The gain parameters of amplifiers are adjustable, and the feedback of working status in the IF system will be sent to MCU in real time for safe operation. The gain parameters could be controlled either by the Ethernet remote way or directly through the local control interface on the system. Preliminary experimental results show the effectiveness of the remote controlled multichannel DBS system.

4.
Rev Sci Instrum ; 90(6): 063503, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31255033

RESUMO

A new correlation electron cyclotron emission (CECE) diagnostic has recently been installed on the HL-2A tokamak in order to study electron temperature fluctuations. Eight radial locations are measured simultaneously through eight pairs of correlated channels. Multiplexers are employed in the intermediate frequency section instead of the conventional separated filter banks to meet strict cross-isolation specifications and lower insertion loss. Relative electron temperature fluctuations are observed by CECE for the first time on the HL-2A by using the spectral decorrelation method. The achieved minimum detectable fluctuation level is up to (T̃e/Te)min∼0.5%. When studying electron temperature fluctuations in the core region with gas puffing, the cross-power spectra show that the amplitude of the electron temperature fluctuation increases in a high temperature and low density plasma. Further analysis demonstrates that the electron temperature gradient ∇Te drives the electron temperature fluctuations together with electron heat transport.

5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 25(1): 23-5, 2001 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-12583297

RESUMO

This paper describes a PC-computer program of a digital remote ECG monitoring system. In addition to current monitor's capabilities of real time displaying of dynamic ECG wave, over-limit alarming, and so on, it has developed most functions of the Holter system, that are recording the data of ECG more than 24 hours, reviewing and analyzing the ECG data, and giving out reports.


Assuntos
Eletrocardiografia Ambulatorial/instrumentação , Software , Telemetria/instrumentação , Humanos , Design de Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA