Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
PLoS One ; 19(5): e0303289, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722891

RESUMO

Malaria and Human Immunodeficiency Virus infections are among the top 10 causes of death in low income countries. Furthermore, many medicines used in these treatment areas are substandard, which contributes to the high death rate. Using a monitoring system to identify substandard and falsified medicines, the study aims to evaluate the quality of antimalarial and antiretroviral medicines in Sahel countries, assessing site conditions, compliance of medicines with pharmacopoeia tests, formulation equivalence with a reference medicine, and the influence of climate on quality attributes. Ultra Performance Liquid Chromatography methods for eight active pharmaceutical ingredients were validated following the International Conference for Harmonization guideline for its detection and quantification. Quality control consists of visual inspections to detect any misinformation or imperfections and pharmacopeial testing to determine the quality of pharmaceutical products. Medicines which complied with uniformity dosage units and dissolution tests were stored under accelerated conditions for 6 months. Artemether/Lumefantrine and Lopinavir/Ritonavir formulations failed uniformity dosage units and disintegration tests respectively, detecting a total of 28.6% substandard medicines. After 6 months stored under accelerated conditions (40 °C // 75% relative humidity) simulating climatic conditions in Sahel countries, some medicines failed pharmacopeia tests. It demonstrated the influence of these two factors in their quality attributes. This study emphasizes the need of certified quality control laboratories as well as the need for regulatory systems to maintain standards in pharmaceutical manufacturing and distribution in these countries, especially when medicines are transported to rural areas where these climatic conditions are harsher.


Assuntos
Antimaláricos , Controle de Qualidade , Antimaláricos/análise , Antimaláricos/normas , Humanos , Antirretrovirais/análise , Saúde Pública , Ritonavir/análise , Ritonavir/uso terapêutico , Administração Oral , Medicamentos Fora do Padrão/análise , Infecções por HIV/tratamento farmacológico , Malária/tratamento farmacológico , Lopinavir/análise , Lopinavir/uso terapêutico
2.
Pharmaceutics ; 16(3)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38543302

RESUMO

Three-dimensional printing in the field of additive manufacturing shows potential for customized medicines and solving gaps in paediatric formulations. Despite successful clinical trials, 3D printing use in pharmaceutical point-of-care is limited by regulatory loopholes and a lack of Pharmacopoeia guidelines to ensure quality. Semi-solid extrusion is a 3D printing technology that stands out for its versatility, but understanding the fluid dynamics of the semi-solid mass is critical. The aim of this research is to look into the advantages of instrumenting a 3D printer with a semi-solid extrusion motor-driven printhead, which is able to record the printing pressure over time, for in situ characterization of the semi-solid mass and quality evaluation of dosage forms. Four formulations using hydrochlorothiazide as the active pharmaceutical ingredient and several excipients were used. Their flow properties were studied at different printing speeds and temperatures using traditional techniques (rheometer and Texture Analyzer) and the proposed semi-solid extrusion motor-driven printhead incorporated into a printing platform. In addition, the influence of printing speed in the printing process was also evaluated by the study of printing pressure and printlet quality. The results demonstrated the similarities between the use of a Texture Analyzer and the semi-solid extrusion motor-driven. However, the latter enables temperature selection and printing speed in accordance with the printing process which are critical printing parameters. In addition, due to the incorporation of a sensor, it was possible to conclude, for the first time, that there is a link between changes in essential printing parameters like printing speed or formulations and variations in printing pressure and printlet quality attributes such as the energy require to obtain a single dosage unit, weight or diameter. This breakthrough holds a lot of potential for assuring the quality of 3D printing dosage forms and paving the way for their future incorporation into point-of-care settings.

3.
Pharmaceutics ; 15(6)2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37376090

RESUMO

3D printing technology can be used to develop individualized medicines in hospitals and pharmacies, allowing a high degree of personalization and the possibility to adjust the dose of the API based on the quantity of material extruded. The main goal of incorporating this technology is to have a stock of API-load print cartridges that could be used at different storage times and for different patients. However, it is necessary to study the extrudability, stability, and buildability of these print cartridges during storage time. A paste-like formulation containing hydrochlorothiazide as a model drug was prepared and distributed in five print cartridges, each of which was studied for different storage times (0 h-72 h) and conditions, for repeated use on different days. For each print cartridge, an extrudability analysis was performed, and subsequently, 100 unit forms of 10 mg hydrochlorothiazide were printed. Finally, various dosage units containing different doses were printed, taking into account the optimized printing parameters based on the results of the extrudability analysis carried out previously. An appropriate methodology for the rapid development of appropriate SSE 3DP inks for pediatrics was established and evaluated. The extrudability analysis and several parameters allowed the detection of changes in the mechanical behavior of the printing inks, the pressure interval of the steady flow, and the selection of the volume of ink to be extruded to obtain each of the required doses. The print cartridges were stable for up to 72 h after processing, and orodispersible printlets containing 6 mg to 24 mg of hydrochlorothiazide can be produced using the same print cartridge and during the same printing process with guaranteed content and chemical stability. The proposed workflow for the development of new printing inks containing APIs will allow the optimization of feedstock material and human resources in pharmacy or hospital pharmacy services, thus speeding up their development and reducing costs.

4.
PLoS One ; 18(3): e0282023, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36928659

RESUMO

The quality of drug products may be affected from manufacture to dispensing, particularly at high temperature and humidity as in Mauritania. This country is not included in the World Health Organization reports on poor quality products due to the lack of a qualified laboratory and monitoring system. Ensuring the quality of medicine is even more relevant in the case of diseases such as Tuberculosis, due to its high prevalence, complex treatment and continuous bacterial resistance. The aim was to develop a monitoring system to assess the quality of antituberculosis drugs products, by the substandard detection based on European and United States Pharmacopeial recommendations regarding quality control. In addition to studying the influence of accelerated storage conditions (40 ± 2°C/75 ± 5% relative humidity) on their qualities and comparing the dissolution profiles to contrast the quality. 18 antituberculosis drug products were taken from Europe and Mauritania, and quality was studied through visual inspection and according to the compliance of the mass uniformity, uniformity of dosage units, dissolution, disintegration and friability pharmacopeial tests. Furthermore, a dissolution profile comparison was carried out to examine quality. A stability study was conducted to assess the influence of climatic conditions on the content and the dissolved amount of the active pharmaceutical ingredients, which were determined by an ultra-performance liquid chromatography system. As result, 69.3% of 13 Mauritanian formulations had a substandard quality mainly due to non-compliance with the test for friability or content uniformity of these medicines. All European drug products complied with pharmacopeia specifications. In addition, storage conditions affected the dissolution rate of ethambutol and the uniformity of the 4 antituberculosis combination drug products.


Assuntos
Antituberculosos , Laboratórios , Mauritânia , Controle de Qualidade , Preparações Farmacêuticas , Comprimidos
5.
Molecules ; 27(20)2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36296733

RESUMO

Drug products used for treating tuberculosis are one of the most widely reported medicines to be classified as falsified or substandard in low- and middle-income countries, representing a major hazard to health. The aim of this study was, firstly, to develop an ultra-performance liquid chromatography (UPLC) method which is able to analyze fixed combination tablets with up to four active pharmaceutical ingredients, including isoniazid, pyrazinamide, rifampicin, and ethambutol. Secondly, we aimed to optimize it through the design of experiments and multi-linear regression based on a central composite design and to validate it according to the guidelines of the International Conference on Harmonization. The application of this tools enabled the identification of the influential factors (flow rate, formic acid, and temperature) and their effects on the studied responses (retention factor and percentage for each drug) as part of the quality by design approach. The method proved to be to be linear in the range from 5.0 to 15 µg/mL for isoniazid, pyrazinamide, and rifampicin, being precise (<1%) and accurate (97−101%). In addition, the method validated for ethambutol proved to be linear from 1.4 to 4.2 µg/mL, as well as precise (0.54%) and accurate (97.3%). The method was stability indicated for all the active pharmaceutical ingredients studied and was able to detect two substandard formulations sampled on the African market.


Assuntos
Medicamentos Fora do Padrão , Tuberculose , Humanos , Etambutol/química , Pirazinamida/uso terapêutico , Pirazinamida/química , Isoniazida/uso terapêutico , Isoniazida/química , Rifampina/uso terapêutico , Rifampina/química , Antituberculosos/uso terapêutico , Antituberculosos/química , Tuberculose/tratamento farmacológico , Cromatografia Líquida , Comprimidos
6.
Int J Pharm X ; 4: 100133, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36299772

RESUMO

Semi-solid extrusion (SSE) is a three-dimensional printing (3DP) process that involves the extrusion of a gel or paste-like material via a syringe-based printhead to create the desired object. In pharmaceuticals, SSE 3DP has already been used to manufacture formulations for human clinical studies. To further support its clinical adoption, the use of a pressure sensor may provide information on the printability of the feedstock material in situ and under the exact printing conditions for quality control purposes. This study aimed to integrate a pressure sensor in an SSE pharmaceutical 3D printer for both material characterization and as a process analytical technology (PAT) to monitor the printing process. In this study, three materials of different consistency were tested (soft vaseline, gel-like mass and paste-like mass) under 12 different conditions, by changing flow rate, temperature, or nozzle diameter. The use of a pressure sensor allowed, for the first time, the characterization of rheological properties of the inks, which exhibited temperature-dependent, plastic and viscoelastic behaviours. Controlling critical material attributes and 3D printing process parameters may allow a quality by design (QbD) approach to facilitate a high-fidelity 3D printing process critical for the future of personalized medicine.

7.
Int J Pharm ; 605: 120801, 2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34139307

RESUMO

Sterilization is a quite challenging step in the development of novel polymeric scaffolds for regenerative medicine since conventional sterilization techniques may significantly alter their morphological and physicochemical properties. Supercritical (sc) sterilization, i.e. the use of scCO2 as a sterilizing agent, emerges as a promising sterilization method due to the mild operational conditions and excellent penetration capability. In this work, a scCO2 protocol was implemented for the one-pot preparation and sterilization of poly(ε-caprolactone) (PCL)/poly(lactic-co-glycolic acid) (PLGA) scaffolds. The sterilization conditions were established after screening against both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli, Pseudomonas aeruginosa) vegetative bacteria and spores of Bacillus stearothermophilus, Bacillus pumilus and Bacillus atrophaeus. The transition from the sterilization conditions (140 bar, 39 °C) to the compressed foaming (60 bar, 26 °C) was performed through controlled depressurization (3.2 bar/min) and CO2 liquid flow. Controlled depressurization/pressurization cycles were subsequently applied. Using this scCO2 technology toolbox, sterile scaffolds of well-controlled pore architecture were obtained. This sterilization procedure successfully achieved not only SAL-6 against well-known resistant bacteria endospores but also improved the scaffold morphologies compared to standard gamma radiation sterilization procedures.


Assuntos
Dióxido de Carbono , Alicerces Teciduais , Bacillus , Regeneração Óssea , Esterilização , Tecnologia
8.
Pharmaceutics ; 12(2)2020 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-32102447

RESUMO

(1) Background: First-line antituberculosis treatment in paediatrics entails the administration of Isoniazid, Pyrazinamide, and Rifampicin. This study examines the possibility of developing a combined dose liquid formulation for oral use that would facilitate dose adjustment and adherence to treatment for younger children. (2) Methods: The active pharmaceutical ingredients stability under in vitro paediatric digestive pH conditions have been checked. The samples were studied as individual or fixed combined paediatric dosages to determine the pH of maximum stability. The use of hydroxypropyl-ß-cyclodextrin to improve Rifampicin solubility and the use of ascorbic acid to increase the stability of the formulation have been studied. (3) Results: Maximum stability of combined doses was determined at pH 7.4, and maximum complexation at pH 8.0. Taking this into account, formulations presented the minimum dose of two active pharmaceutical ingredients dissolved. The addition of ascorbic acid at 0.1% w/v enables the detection of a higher remaining quantity of both drugs after three days of storage at 5 °C. (4) Conclusions: a formulation which combines the minimum paediatric dosages dissolved recommended by WHO for Isoniazid and Rifampicin has been developed. Future assays are needed to prolong the stability of the formulation with the aim of incorporating Pyrazinamide to the solution.

9.
Drug Dev Ind Pharm ; 46(2): 309-317, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31944867

RESUMO

Objective: Develop a child-friendly Fixed Dose Combination (FDC) water-dispersible tablet for Tuberculosis (TB) treatment, with 50, 150, and 75 mg of isoniazid, pyrazinamide and rifampicin respectively. This new formulation must contain the lowest number of excipients accepted for pediatrics and fulfill all the pharmacopeia requirements.Significance: At present, there is no adequate market dosage form available for children. There is, however, one in a prequalification phase by the World Health Organization but its composition contains excipients which may not be suitable for pediatrics. Therefore, this new formulation would cover this therapeutic gap.Methods: A factorial design, based on three quantitative factors (compression force and concentration of AcDiSol® and Explosol®) at three levels each, was performed to elucidate their influence over disintegration time and friability. In addition, the influence of the press speed on disintegration time, friability, tensile strength, fineness of dispersion and content uniformity over the target tablet was tested. A stability test was done following ICH guideline for accelerated conditions.Results: Tablets developed with 9% w/w of Explosol® and a compression force of 16 kN disintegrated in less than 3 min and showed a friability below 1% when 15-mm punches were used. The tableting process could be done up to 25 and 50 cycles/minute ensuring good quality attributes when 15 and 12-mm punches were used, respectively. All APIs remained inside the limit of ± 5% of drug content till 6 months of storage.Conclusion: A high-quality child-friendly FDC water-dispersible tablet was developed improving the treatment of TB in pediatric.


Assuntos
Antituberculosos/administração & dosagem , Antituberculosos/química , Isoniazida/química , Pirazinamida/química , Rifampina/química , Comprimidos/química , Tuberculose/tratamento farmacológico , Química Farmacêutica/métodos , Criança , Composição de Medicamentos/métodos , Excipientes/química , Dureza/efeitos dos fármacos , Humanos , Isoniazida/administração & dosagem , Pediatria/métodos , Pirazinamida/administração & dosagem , Rifampina/administração & dosagem , Solubilidade/efeitos dos fármacos , Comprimidos/administração & dosagem , Resistência à Tração
10.
AAPS PharmSciTech ; 20(5): 208, 2019 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-31161450

RESUMO

Individualized medicines for pediatrics are a useful alternative if there is no correct dosage marketed for this segment (easy to swallow, adequate volume and content, correct composition for pediatrics, good organoleptic properties, etc.). Its validation process must ensure quality testing: its content uniformity, physical (homogeneity after shaking), chemical, and microbiological stability. Some of these attributes are checked by the recommendations of European Pharmacopoeia (Ph. Eur.), International Conference of Harmonization (ICH), and National Formularies but others are not. The aim of this study is to develop a general high-demanding strategy to ensure the final quality of liquid dosage forms testing and developing standard operating processes (SOPs) for the elaboration of individualized oral liquid medicines for pediatric use. Furosemide was used as an example of the validation of an individualized liquid solution for pediatric use. Three SOPs were selected according to their composition and the recommendations of liquid dosage forms for pediatric use. Quality attributes according to National Formularies, Ph. Eur., and ICH were tested: pH, organoleptic properties, uniformity of mass of delivered dose from multidose containers, and chemical stability. In this study, a general high-demanding strategy was elaborated to validate oral liquid dosage forms, including validation of the analytical method used to test their quality. A second part focuses on the elaboration of liquid formulations for pediatrics with the highest standards of quality taking into account CQAs that were not contemplated by official compendial such as content uniformity and physical stability.


Assuntos
Excipientes/normas , Furosemida/normas , Pediatria/normas , Medicina de Precisão/normas , Administração Oral , Criança , Diuréticos/administração & dosagem , Diuréticos/normas , Composição de Medicamentos/métodos , Composição de Medicamentos/normas , Excipientes/administração & dosagem , Furosemida/administração & dosagem , Humanos , Pediatria/métodos , Soluções Farmacêuticas/administração & dosagem , Soluções Farmacêuticas/normas , Medicina de Precisão/métodos
11.
J Pediatr Pharmacol Ther ; 23(5): 405-409, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30429695

RESUMO

OBJECTIVES: Extemporaneous or magistral formulation of active pharmaceutical ingredients using traditional compounding techniques is a common practice when no commercial form is available for pediatrics. For this vulnerable group of patients, the formulation must be prepared with the minimum quantity and lowest proportion of excipients approved for pediatrics, avoiding the use of preservatives. Often the vehicles used for these preparations are dilutions of simple syrup with water. The objective of this study is to assess the effectiveness of antimicrobial preservation in simple syrup diluted with aqua conservans (conserved water), without propylene glycol or with a reduced proportion of parabens. METHODS: The European Pharmacopoeia test of efficacy of antimicrobial preservation was applied to 5 trial vehicles prepared with simple syrup diluted with water. RESULTS: Simple syrup is stable during 14 days. Vehicles prepared with simple syrup diluted with purified water did not meet the microbiological quality criteria, but when they are diluted with water that incorporates propylene glycol and parabens (aqua conservans), then they meet the criteria. In addition, if the water is prepared with parabens and without propylene glycol, the criteria for the dilution are met. Nevertheless, if the dilution is done with water prepared with an insufficient proportion of parabens to act as preservatives, the dilution does not meet the pharmacopoeia microbiological criteria. CONCLUSIONS: Dilution of simple syrup (50:50 v/v) to prepare a vehicle for extemporaneous or magistral preparation is microbiologically safe when water with methylparaben and propylparaben is used in a proportion of 0.08% and 0.02% (w/w), respectively, avoiding the use of propylene glycol as a solvent and thus its toxic effects in pediatrics.

12.
Pharm Dev Technol ; 23(10): 978-985, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27658320

RESUMO

There is as yet no commercialized preparation for oral administration of flecainide acetate (FA) to children. In such cases, manipulation of commercial tablets is the usual practice in pharmacy services of hospitals and compounding pharmacies, to provide a suitable dosage form for this vulnerable pediatric population group. In this study, we have formulated FA as an oral solution, as an alternative to the suspension elaborated from commercial tablets. Due to this sensitivity of young patients, we have used the pure active pharmaceutical ingredient (API) and the lowest permitted levels of pediatric excipients. Despite being a highly soluble API, only one of the formulations appears as a transparent solution due to complete FA solubilization. The proposed formulation is physico-chemically and microbiologically stable and the mass and dose uniformity is appropriate for 30 days' storage at 25 °C.


Assuntos
Antiarrítmicos/administração & dosagem , Flecainida/administração & dosagem , Bloqueadores do Canal de Sódio Disparado por Voltagem/administração & dosagem , Administração Oral , Antiarrítmicos/química , Carga Bacteriana , Criança , Composição de Medicamentos/métodos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Excipientes/química , Flecainida/química , Humanos , Pediatria , Soluções Farmacêuticas/química , Solubilidade , Suspensões/química , Bloqueadores do Canal de Sódio Disparado por Voltagem/química
13.
J Pharm Sci ; 106(11): 3353-3362, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28732712

RESUMO

PLGA (poly(lactic-co-glycolic) acid)-PEG (polyethylene glycol)-PLGA synthesis conditions have an impact on the physicochemical features of the copolymer and its usefulness as biomaterial. This study reports on an analysis of the composition and structural properties of PLGA-PEG-PLGA copolymers applying a variety of analytical techniques. Viscoelastic properties and particularly the temperature-responsive behavior of PLGA-PEG-PLGA showed a marked dependence on copolymer structural features. Physicochemical and biological properties, such as bioadhesion, biocompatibility and cell viability, of the raw copolymers and their gels were also evaluated. The most promising copolymer was chosen to formulate the osteoinductive protein bone morphogenetic protein-2 (125I-BMP-2), and the ability of its gels to sustain the release both in vitro and in vivo was monitored in situ using a gamma counter. In vitro diffusion studies were carried out using a bioinspired set-up that included a biorelevant receptor medium. In vivo release tests after implantation in a critical-size calvarial defect model showed an important burst, but then the release fitted well to the square-root kinetics. Importantly, the release rate constants recorded in vitro and in vivo matched each other suggesting close in vitro-in vivo correlation. Overall, the information gathered opens new perspectives in the biomedical application of these temperature-sensitive materials.


Assuntos
Proteína Morfogenética Óssea 2/administração & dosagem , Preparações de Ação Retardada/química , Géis/química , Polietilenoglicóis/química , Poliglactina 910/química , Adesividade , Animais , Proteína Morfogenética Óssea 2/farmacocinética , Galinhas , Liberação Controlada de Fármacos , Masculino , Ratos Sprague-Dawley , Temperatura
14.
Pharm Dev Technol ; 22(2): 191-197, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27109383

RESUMO

CONTEXT: The formulation of an active pharmaceutical ingredient (API) as oral solution or suspension in pediatrics is a habitual practice, due to the non-existence of many commercialized medicines in pediatric doses. It is also the simplest way to prepare and administer them to this vulnerable population. The design of a formulation that assures the dose and the system stability depends on the physico-chemical properties of the API. OBJECTIVE: In this study, we formulate a class IV API, Acetazolamide (AZM) as suspension for oral administration to pediatric population. The suspension must comply attributes of quality, safety and efficacy for this route of administration. MATERIALS AND METHODS: We use simple compounding procedures, as well as fewer pure excipients, as recommended for children. Mass and uniformity content assays and physical and chemical stability studies were performed. To quantify the API an UPLC method was used. RESULTS AND DISCUSSION: We verified the physico-chemical stability of the suspensions and that they passed the mass test of the European Pharmacopeia (EP), but not the dose uniformity test. CONCLUSIONS: This reveals that AZM must be formulated as liquid forms with a more complex system of excipients (not usually indicated in pediatrics), or otherwise solid forms capable of assuring uniformity of mass and dose for every dosage unit.


Assuntos
Acetazolamida/administração & dosagem , Acetazolamida/química , Anticonvulsivantes/administração & dosagem , Anticonvulsivantes/química , Administração Oral , Criança , Composição de Medicamentos , Estabilidade de Medicamentos , Excipientes/química , Humanos , Suspensões
15.
J Sep Sci ; 39(14): 2689-701, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27184267

RESUMO

An ultra high performance liquid chromatography method was developed and validated for the quantitation of triamcinolone acetonide in an injectable ophthalmic hydrogel to determine the contribution of analytical method error in the content uniformity measurement. During the development phase, the design of experiments/design space strategy was used. For this, the free R-program was used as a commercial software alternative, a fast efficient tool for data analysis. The process capability index was used to find the permitted level of variation for each factor and to define the design space. All these aspects were analyzed and discussed under different experimental conditions by the Monte Carlo simulation method. Second, a pre-study validation procedure was performed in accordance with the International Conference on Harmonization guidelines. The validated method was applied for the determination of uniformity of dosage units and the reasons for variability (inhomogeneity and the analytical method error) were analyzed based on the overall uncertainty.


Assuntos
Hidrogéis/química , Triancinolona Acetonida/análise , Cromatografia Líquida de Alta Pressão , Método de Monte Carlo
16.
Artigo em Inglês | MEDLINE | ID: mdl-27107247

RESUMO

Size exclusion chromatography (SEC) with different detection modes was assessed as a means to characterize the type of bevacizumab aggregate that forms under thermal stress, quantitatively monitoring the aggregation kinetics. The combination of SEC with light-scattering (SEC/LS) detection was validated using in-study validation process. This was performed by applying a strategy based on a control chart to monitor the process parameters and by inserting quality control samples in routine runs. The SEC coupled with a differential refractive-index detector (SEC/RI) was validated using a pre-study validation process in accordance with the ICH-Q2 (R1) guidelines and in-study monitoring in accordance with the Analytical Target Profile (ATP) criteria. The total error and ß-expectation tolerance interval rules were used to assess method suitability and control the risk of incorrectly accepting unsuitable analytical methods. The aggregation kinetics data were interpreted using a modified Lumry-Eyring model. The true order of the reaction was determined using the initial-rate approach. All the kinetic data show a linear Arrhenius dependence within the studied temperature range. The Arrhenius approach over-predicted the aggregation rate for 5°C, but provides an idea of the aggregation process and amount of aggregate formed. In any case, real-time stability data are necessary to establish the product shelf-life.


Assuntos
Anticorpos Monoclonais/análise , Cromatografia em Gel/métodos , Bevacizumab/análise , Cinética , Luz , Modelos Lineares , Modelos Teóricos , Estabilidade Proteica , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
17.
Eur J Pharm Sci ; 77: 170-9, 2015 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-26091571

RESUMO

Size exclusion chromatography with light scattering detection (SEC-MALLS) was assessed as a means to characterize the type of bevacizumab aggregates that form under mechanical and thermal stress, quantitatively monitoring the aggregation kinetics. The analytical method was monitored and verified during routine use at two levels: (1) the "pre-study" validation shows that the method is specific, linear, accurate, precise, robust and stability indicating; (2) the "in-study" validation was verified by inserting quality control samples and the use of control charts, indicating that the analytical method is in statistical control and stable. The aggregation kinetics data were interpreted using a modified Lumry-Eyring model, but the quality of the fit can be considered poor (R(2)>0.96), especially at higher temperatures. This indicates that the order of the reaction could not be reliably determined, suggesting a different degradation mechanism. The kinetic data set also fit the minimalistic Finke-Watzky (F-W) 2-step model, with an excellent quality of fit (R(2)>0.99), yielding the first quantitative rate constant for the steps of nucleation and growth in bevacizumab aggregation. The bevacizumab pharmaceutical preparation contains (initially) dimers, approximately 1.6% of bevacizumab total concentration, and the effect on aggregation kinetics of seeding was analyzed using the F-W 2-step model assuming [B]0≠0 (for the seeded case). The results suggested that the seeding had no impact on aggregation kinetics. Furthermore, the Arrhenius equation cannot be used to extrapolate the shelf-life since no linear temperature dependence of the rate constant was found within the temperature range. Although the real-time stability data provides the basis for determining the product shelf-life, predictive methodologies such as Vogel-Tammann-Fulcher (VFT) or the Arrhenius approach can be misleading and result in overestimates of the product shelf-life. However, they can be successfully applied to fixing the lower and upper limits of the aggregation rate, i.e. the best and worst-case scenarios regarding the aggregation potential of the product. In conclusion, the present study evaluates the first application of the F-W 2-step model to fitting and interpretation of experimental aggregation data for bevacizumab pharmaceutical preparations, using SEC-MALLS in this context.


Assuntos
Bevacizumab/química , Temperatura Alta , Modelos Químicos , Estresse Mecânico , Cinética , Termodinâmica
18.
J Chromatogr A ; 1353: 89-98, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24786652

RESUMO

In this study, we investigated if the size-exclusion chromatography coupled with light-scattering and refractive index detection (SEC/LS/RI) method is fitted for its intended purpose and checked if the analytical method is able to provide enough conforming results. For this, the process capability indices Cp, Cpk, and Cpm were computed. The traditional X-chart and moving range (MR) chart were used by the same analyst to monitor the equipment in the laboratory over a 1-year period. For this, a bovine serum albumin (BSA) sample (0.3 mg mL(-1)) with a nominal Mw of 66.4 kDa was analyzed each working day. The results confirmed that the analytical method is in-control and stable. To determine whether the given process meets the present capability requirement and runs under the desired quality conditions, the Pearn and Shu (2003) method based on the lower confidence bound C on Cpm was used. The estimator Cpm was 1.81, and the lower confidence bound C was 1.40. We therefore conclude that the true value of the method capability Cpm is no less than 1.40 with a 95% level of confidence. This result indicates that the method is satisfactory and no stringent precision control is required. The usefulness of this method was applied in the characterization of bevacizumab commercial pharmaceutical preparations stored under different conditions that lead to aggregation. In this case, the computed Cpm index was 0.98 (0.70, 1.26), which indicates that the method does not comply with the specification limits and needs to be revised. The quality improvement effort should: (1) reduce the uncertainty in the absolute Mw determination; (2) either move the process mean closer to the target value or reduce the process variation, i.e. improve the method accuracy (µ-T) and precision (σ(2)). On this point, the Bayesian posterior distribution of the mean and standard deviation pointed out the need to control the precision but specially accuracy in order to reduce the overall uncertainty of analytical method and thus, the method is capable.


Assuntos
Anticorpos Monoclonais Humanizados/análise , Cromatografia em Gel/métodos , Animais , Teorema de Bayes , Bevacizumab , Bovinos , Luz , Peso Molecular , Refratometria , Soroalbumina Bovina/análise
19.
Talanta ; 115: 490-9, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24054623

RESUMO

A simple and reproducible UPLC method was developed and validated for the quantitative analysis of finasteride in low-dose drug products. Method validation demonstrated the reliability and consistency of analytical results. Due to the regulatory requirements of pharmaceutical analysis in particular, evaluation of robustness is vital to predict how small variations in operating conditions affect the responses. Response surface methodology as an optimization technique was used to evaluate the robustness. For this, a central composite design was implemented around the nominal conditions. Statistical treatment of the responses (retention factor and drug concentrations expressed as percentage of label claim) showed that methanol content in mobile-phase and flow rate were the most influential factors. In the optimization process, the compromise decision support problem (cDSP) strategy was used. Construction of the robust domain from response-surfaces provided tolerance windows for the factors affecting the effectiveness of the method. The specified limits for the USP uniformity of dosage units assay (98.5-101.5%) and the purely experimental variations based on the repeatability test for center points (nominal conditions repetitions) were used as criteria to establish the tolerance windows, which allowed definition design space (DS) of analytical method. Thus, the acceptance criteria values (AV) proposed by the USP-uniformity of assay only depend on the sampling error. If the variation in the responses corresponded to approximately twice the repeatability standard deviation, individual values for percentage label claim (%LC) response may lie outside the specified limits; this implies the data are not centered between the specified limits, and that this term plus the sampling error affects the AV value. To avoid this fact, the limits specified by the Uniformity of Dosage Form assay (i.e., 98.5-101.5%) must be taken into consideration to fix the tolerance windows for each factor. All these results were verified by the Monte Carlo simulation. In conclusion, the level of variability for different factors must be calculated for each case, and not arbitrary way, provided a variation is found higher than the repeatability for center points and secondly, the %LC response must lie inside the specified limits i.e., 98.5-101.5%. If not the UPLC method must be re-developed.


Assuntos
Inibidores de 5-alfa Redutase/análise , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Cromatografia Líquida de Alta Pressão/normas , Finasterida/análise , Comprimidos/química , Cromatografia Líquida de Alta Pressão/métodos , Análise Fatorial , Método de Monte Carlo , Reprodutibilidade dos Testes , Projetos de Pesquisa
20.
Talanta ; 94: 158-66, 2012 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-22608429

RESUMO

Although the basic science behind current methods for studying biopharmaceutical drug stability has not changed significantly, the techniques available for predicting stability have evolved over the years. This paper therefore describes and discusses various options of data analysis for accelerated degradation studies of peptide and protein drugs based on the Arrhenius equation. Both linear and non-linear regression analyses are also discussed. The results indicate that the simultaneous treatment of all data, as opposed to determining individual rate constants is clearly preferable, combined with the use of the reparameterized Arrhenius equation. The estimated shelf-life at 5 °C varied between 2.2 and 4.0 years in function of the temperature range and procedure used, whereas the precision of the estimated parameter is reflected in the width of the 95% confidence intervals, the classic Arrhenius analysis was maxima. All these results were evaluated by the bootstrap approach.


Assuntos
Produtos Biológicos/análise , Tetragastrina/análise , Cromatografia Líquida , Cromatografia de Fase Reversa , Estabilidade de Medicamentos , Humanos , Cinética , Espectrometria de Massas , Análise de Regressão , Projetos de Pesquisa , Temperatura , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA