1.
J Clin Monit Comput ; 31(2): 427-433, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26897033

RESUMO

Automated control of inspired oxygen for newborn infants is an emerging technology, currently limited by reliance on a single input signal (oxygen saturation, SpO2). This is while other signals that may herald the onset of hypoxic events or identify spurious hypoxia are not usually utilised. We wished to assess the frequency of apnoea, loss of circuit pressure and/or motion artefact in proximity to hypoxic events in preterm infants on non-invasive ventilation. Hypoxic events (SpO2 < 80 %) were identified using a previously acquired dataset obtained from preterm infants receiving non-invasive ventilation. Events with concomitant apnoea, loss of circuit pressure or oximetry motion artefact were annotated, and the frequency of each of these factors was determined. The effect of duration and timing of apnoea on the characteristics of the associated hypoxic events was studied. Among 1224 hypoxic events, 555 (45 %) were accompanied by apnoea, 31 (2.5 %) by loss of circuit pressure and 696 (57 %) by motion artefact, while for 224 (18 %) there were no concomitant factors identified. Respiratory pauses of longer duration (>15 s) preceding hypoxic events, were associated with a relatively slow decline in SpO2 and more prolonged hypoxia compared to shorter pauses. Hypoxic events are frequently accompanied by respiratory pauses and/or motion artefact. Real-time monitoring and input of respiratory waveform may thus improve the function of automated oxygen controllers, allowing pre-emptive responses to respiratory pauses. Furthermore, use of motion-resistant oximeters and plethysmographic waveform assessment procedures will help to optimise feedback control of inspired oxygen delivery.


Assuntos
Hipóxia , Ventilação não Invasiva/instrumentação , Oximetria/instrumentação , Processamento de Sinais Assistido por Computador , Algoritmos , Apneia , Artefatos , Gráficos por Computador , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/terapia , Movimento (Física) , Ventilação não Invasiva/métodos , Oximetria/métodos , Oxigênio , Respiração , Interface Usuário-Computador
2.
Arch Dis Child Fetal Neonatal Ed ; 102(1): F37-F43, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27573518

RESUMO

OBJECTIVE: To evaluate the performance of a novel rapidly responsive proportional-integral-derivative (PID) algorithm for automated oxygen control in preterm infants with respiratory insufficiency. DESIGN: Interventional study of a 4-hour period of automated oxygen control compared with combined data from two flanking periods of manual control (4 hours each). SETTING: Neonatal intensive care unit. PARTICIPANTS: Preterm infants (n=20) on non-invasive respiratory support and supplemental oxygen, with oxygen saturation (SpO2) target range 90%-94% (manual control) and 91%-95% (automated control). Median gestation at birth 27.5 weeks (IQR 26-30 weeks), postnatal age 8.0 (1.8-34) days. INTERVENTION: Automated oxygen control using a standalone device, receiving SpO2 input from a standard oximeter and computing alterations to oxygen concentration that were actuated with a modified blender. The PID algorithm was enhanced to avoid iatrogenic hyperoxaemia and adapt to the severity of lung dysfunction. MAIN OUTCOME MEASURE: Proportion of time in the SpO2 target range, or above target range when in air. RESULTS: Automated oxygen control resulted in more time in the target range or above in air (manual 56 (48-63)% vs automated 81 (76-90)%, p<0.001) and less time at both extremes of oxygenation. Prolonged episodes of hypoxaemia and hyperoxaemia were virtually eliminated. The control algorithm showed benefit in every infant. Manual changes to oxygen therapy were infrequent during automated control (0.24/hour vs 2.3/hour during manual control), and oxygen requirements were unchanged (automated control period 27%, manual 27% and 26%, p>0.05). CONCLUSIONS: The novel PID algorithm was very effective for automated oxygen control in preterm infants, and deserves further investigation.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Doenças do Prematuro/terapia , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Oxigenoterapia/métodos , Oxigênio/administração & dosagem , Insuficiência Respiratória/terapia , Algoritmos , Automação , Estudos Cross-Over , Feminino , Seguimentos , Humanos , Recém-Nascido , Masculino , Oximetria/métodos , Resultado do Tratamento