Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 12920, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839866

RESUMO

The parameter extraction process for PV models poses a complex nonlinear and multi-model optimization challenge. Accurately estimating these parameters is crucial for optimizing the efficiency of PV systems. To address this, the paper introduces the Adaptive Rao Dichotomy Method (ARDM) which leverages the adaptive characteristics of the Rao algorithm and the Dichotomy Technique. ARDM is compared with the several recent optimization techniques, including the tuna swarm optimizer, African vulture's optimizer, and teaching-learning-based optimizer. Statistical analyses and experimental results demonstrate the ARDM's superior performance in the parameter extraction for the various PV models, such as RTC France and PWP 201 polycrystalline, utilizing manufacturer-provided datasheets. Comparisons with competing techniques further underscore ARDM dominance. Simulation results highlight ARDM quick processing time, steady convergence, and consistently high accuracy in delivering optimal solutions.

2.
Sci Rep ; 14(1): 3867, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365987

RESUMO

Solar Photovoltaic (SPV) technology advancements are primarily aimed at decarbonizing and enhancing the resiliency of the energy grid. Incorporating SPV is one of the ways to achieve the goal of energy efficiency. Because of the nonlinearity, modeling of SPV is a very difficult process. Identification of variables in a lumped electric circuit model is required for accurate modeling of the SPV system. This paper presents a new state-of-the-art control technique based on human artefacts dubbed Drone Squadron Optimization for estimating 15 parameters of a three-diode equivalent model solar PV system. The suggested method simulates a nonlinear relationship between the P-V and I-V performance curves, lowering the difference between experimental and calculated data. To evaluate the adaptive performance in every climatic state, two different test cases with commercial PV cells, RTC France and photo watt-201, are used. The proposed method provides a more accurate parameter estimate. To validate the recommended approach's performance, the data are compared to the results of the most recent and powerful methodologies in the literature. For the RTC and PWP Photo Watt Cell, the DSO technique has the lowest Root Mean Square Error (RMSE) of 6.7776 × 10-4 and 0.002310324 × 10-4, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA