Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Med Biol ; 65(21): 215015, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-32756019

RESUMO

BrachyView is a novel in-body imaging system developed to provide real-time intraoperative dosimetry for low dose rate prostate brachytherapy treatments. Seed positions can be reconstructed after in-vivo implantation using a high-resolution pinhole gamma camera inserted into the patient rectum. The obtained data is a set of 2D projections of the seeds on the image plane. The 3D reconstruction algorithm requires the identification of the seed's centre of mass. This work presents the development and techniques adopted to build an algorithm that provides the means for fully automatic seed centre of mass identification and 3D position reconstruction for real-time applications. The algorithm presented uses a local feature detector, speeded up robust features, to perform detection of brachytherapy seed 2D projections from images, allowing for robust seed identification. Initial results have been obtained with datasets of 30, 96 and 98 I-125 brachytherapy seeds implanted into a prostate gel phantom. It can detect 97% of seeds and correctly match 97% of seeds. The average overall computation time of 2.75 s per image and improved reconstruction accuracy of 22.87% for the 98 seed dataset was noted. Elimination processes for initial false positive detection removal have shown to be extremely effective, resulting in a 99.9% reduction of false positives, and when paired with automatic frame alignment and subtraction procedures allows for the effective removal of excess counts generated by previously implanted needles. The proposed algorithm will allow the BrachyView system to be used as a real-time intraoperative dosimetry tool for low dose rate prostate brachytherapy treatments.


Assuntos
Algoritmos , Braquiterapia/métodos , Próteses e Implantes , Doses de Radiação , Automação , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Técnica de Subtração , Fatores de Tempo
2.
Phys Med ; 66: 66-76, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31563727

RESUMO

PURPOSE: BrachyView is a novel in-body imaging system developed with the objective to provide real-time intraoperative dosimetry for low dose rate (LDR) prostate brachytherapy treatments. The BrachyView coordinates combined with conventional transrectal ultrasound (TRUS) imaging, provides the possibility to localise the effective position of the implanted seeds inside the prostate volume, providing a unique tool for intra-operative verification of the quality of the implantation. This research presents the first complete LDR brachytherapy plan reconstructed by the BrachyView system and is used to evaluate the effectiveness of an imaging algorithm with baseline subtraction. METHODS: A plan featuring 98 I-125 brachytherapy seeds, with an average activity of 0.248 mCi, were implanted into a prostate gel phantom under TRUS guidance. Images of implanted seeds were obtained by the BrachyView after the implantation of seeds. The baseline subtraction algorithm is applied as a pixel-to-pixel counts subtraction and is applied to every second projection obtained after the implantation of each needle. Seed positions and effectiveness of the baseline reconstruction in the identification of seeds were verified by a high-resolution post-implant CT scan. RESULTS: A complete brachytherapy plan has been reconstructed with a 100% detection rate. This is possible due to the effectiveness of the baseline subtraction, with its application an overall increase of 11.3% in position accuracy and 8.2% increase in detection rate was noted. CONCLUSION: It has been demonstrated that the BrachyView system shows the potential to be a solution to providing clinics with the means for intraoperative dosimetry for LDR prostate brachytherapy treatments.


Assuntos
Algoritmos , Braquiterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Técnica de Subtração , Humanos , Masculino , Imagens de Fantasmas , Próteses e Implantes , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Ultrassonografia
3.
Phys Med ; 34: 55-64, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28118951

RESUMO

PURPOSE: BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). METHODS: The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U125I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. RESULTS: The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. CONCLUSIONS: The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface.


Assuntos
Braquiterapia/instrumentação , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Doses de Radiação , Radioterapia Guiada por Imagem/instrumentação , Reto , Ultrassonografia/instrumentação , Géis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA