Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Clin Lab Anal ; : e25038, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38590133

RESUMO

OBJECTIVE: This study aimed to establish a highly sensitive and rapid single-tube, two-stage, multiplex recombinase-aided qPCR (mRAP) assay to specifically detect the khe, blaKPC-2, and blaNDM-1 genes in Klebsiella pneumoniae. METHODS: mRAP was carried out in a qPCR instrument within 1 h. The analytical sensitivities of mRAP for khe, blaKPC-2, and blaNDM-1 genes were tested using recombinant plasmids and dilutions of reference strains. A total of 137 clinical isolates and 86 sputum samples were used to validate the clinical performance of mRAP. RESULTS: mRAP achieved the sensitivities of 10, 8, and 14 copies/reaction for khe, blaKPC-2, and blaNDM-1 genes, respectively, superior to qPCR. The Kappa value of qPCR and mRAP for detecting khe, blaKPC-2, and blaNDM-1 genes was 1, 0.855, and 1, respectively (p < 0.05). CONCLUSION: mRAP is a rapid and highly sensitive assay for potential clinical identification of khe, blaKPC-2, and blaNDM-1 genes in K. pneumoniae.

2.
J Clin Lab Anal ; 37(5): e24858, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36916770

RESUMO

The most prevalent viruses currently causing diarrhea are norovirus and rotavirus, and rapid and sensitive detection methods are essential for the early diagnosis of disease. The purpose of this study was to establish a sensitive single-tube two-stage nucleic acid amplification method-reverse transcription recombinase-assisted PCR (RT-RAP)-for simultaneous detection of norovirus GII and group A Rotavirus, with the first stage consisting of isothermal reverse transcription recombinase-aided amplification (RT-RAA) and the second stage consisting of qPCR (quantitative PCR). RT-RAP is more sensitive than either RT-RAA or qRT-PCR (quantitative RT-PCR) alone. And the addition of a barrier that can be disassembled after heating enabled the detection of samples within 1 h in a single closed tube. Sensitivity was 10 copies/reaction of norovirus (Novs) GII and group A rotavirus (RVA). In parallel, two hundred fecal specimens were used to evaluate the method and compare it with a commercial fluorescent quantitative RT-PCR. The data showed kappa values of 0.957 and 0.98 (p < 0.05) for detecting Novs GII and RVA by the two methods, indicating the potential of the newly established assay to be applied to clinical and laboratory testing.


Assuntos
Infecções por Caliciviridae , Gastroenterite , Norovirus , Rotavirus , Humanos , Rotavirus/genética , Norovirus/genética , Gastroenterite/diagnóstico , Infecções por Caliciviridae/diagnóstico , Fezes , Recombinases , Sensibilidade e Especificidade
3.
Diagn Microbiol Infect Dis ; 104(4): 115801, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36130430

RESUMO

Timely identification of respiratory pathogens guides specific treatment, reduces hospital costs and minimizes the excessive use of antibiotics. A new multiplex real-time PCR panel was developed based on an automatic molecular detection and analysis system (AutoMolec system), consisting of three separate internally controlled assays. Mycoplasma pneumoniae, Chlamydia pneumoniae, adenovirus, human metapneumovirus, influenza B virus, respiratory syncytial virus and human parainfluenza virus 1-3 may be directly detected in original samples. The system's clinical performance was evaluated by comparison with an approved commercial kit, using 517 clinical samples. The limit of detection of the AutoMolec mRT-PCR panel ranged from 4 × 10-4 ∼3.3 TCID50/mL and no cross-reaction with common respiratory pathogens was observed. The AutoMolec mRT-PCR panel had 99.09% sensitivity and 100.0% specificity and overall detection consistency was 99.61%, making it comparable to that of the commercial kit. Therefore, the AutoMolec mRT-PCR panel has great potential for routine screening of respiratory infection in China.


Assuntos
Metapneumovirus , Vírus Sincicial Respiratório Humano , Infecções Respiratórias , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Multiplex , Infecções Respiratórias/diagnóstico , Metapneumovirus/genética , Sensibilidade e Especificidade
4.
AMB Express ; 12(1): 71, 2022 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-35689713

RESUMO

Epstein-Barr virus (EBV), a common human γ-herpesvirus, infects more than 90% of adults worldwide. The purpose of this study was to establish a novel EBV detection method by combining the recombinase aided amplification (RAA) assay with an initial enrichment step that utilizes magnetic beads coated with a recombinant human mannan-binding lectin (rhMBL, M1 protein). An M1 protein-protein A magnetic bead complex (M1 beads) was prepared and used to achieve separation and enrichment of EBV from blood. After nucleic acid extraction, DNA was amplified by RAA. Using 388 whole blood samples and 1 serum sample, we explored the specificity, sensitivity and applicability of the newly developed detection method and compared it with commercial quantitative real-time polymerase chain reaction (qPCR) following M1 bead enrichment, traditional qPCR and traditional RAA. After enrichment, the positivity rate of EBV was increased from 15.94% to 17.74% by RAA (P < 0.05) and from 7.20% to 15.17% by qPCR (P < 0.05). The viral loads after enrichment were increased by 1.13 to 23.19-fold (P < 0.05). Our data demonstrates that an RAA assay incorporating M1 bead enrichment is a promising tool for detecting low EBV viral loads in blood samples that will facilitate an early response to EBV infection.

5.
J Microbiol Methods ; 193: 106404, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34990645

RESUMO

Vibrio parahaemolyticus (V. parahaemolyticus) is a widely distributed pathogen in the coastal areas, which causes food poisoning and leads to gastroenteritis and sepsis. Therefore, developing a simple, sensitive, and rapid detection method for V. parahaemolyticus is a major concern globally. This study established a sensitive and rapid technique based on recombinase aided amplification (RAA) to detect V. parahaemolyticus. The RAA reaction was carried out successfully at 39 °C within 30 min. The sensitivity of the RAA assay was 101 copies/µL using the recombinant plasmid and 10-3 ng/µL using the V. parahaemolyticus strain. In addition, RAA directly detected 7 × 103 CFU/mL of simulated fecal samples and 0.1 CFU/mL after enrichment for 4 h. The sensitivity and specificity of the RAA assay using fecal and fish samples were 100% similar to that of the real-time PCR. We conclude that the RAA assay is an ideal screening method for detecting V. parahaemolyticus due to its rapidity, high accuracy, and simplicity in operation.


Assuntos
Vibrio parahaemolyticus , Animais , Primers do DNA , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Recombinases , Sensibilidade e Especificidade , Vibrio parahaemolyticus/genética
6.
Biomed Environ Sci ; 34(8): 650-655, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34474727

RESUMO

Epstein-Barr virus (EBV) and cytomegalovirus (CMV), two of the most prevalent human herpesviruses, cause a wide spectrum of diseases and symptoms and are associated with serious health problem. In this study, we developed an internal control reference recombinase-aided amplification (ICR-RAA) assay for the rapid detection of EBV and CMV within 30 min. The assay had a sensitivity of 5 and 1 copies/test for EBV and CMV, respectively, with no cross reaction with other pathogens. In comparison with those of the commercial quantitative polymerase chain reaction (qPCR), the sensitivity of the EBV and CMV ICR-RAAs using extracted DNA was 93.33% and 84.84%, respectively; the specificity was 98.75% and 100.00%, respectively; and the Kappa values were 0.930 and 0.892 ( P < 0.05), respectively. In comparison with those of qPCR, the sensitivity of the EBV and CMV ICR-RAAs using the DNA by thermal lysis was 72.22% and 80.00%, respectively; the specificity was 100.00%; and the Kappa values were 0.764 and 0.878 ( P < 0. 05), respectively. Thus, rapid and specific detection of EBV and CMV is possible using ICR-RAA assays.


Assuntos
Citomegalovirus/genética , DNA Viral/análise , Herpesvirus Humano 4/genética , Técnicas de Amplificação de Ácido Nucleico , Recombinases/genética , Adolescente , Adulto , Criança , Pré-Escolar , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , Infecções por Vírus Epstein-Barr/diagnóstico , Infecções por Vírus Epstein-Barr/virologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Adulto Jovem
7.
Int J Infect Dis ; 93: 224-230, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32045697

RESUMO

OBJECTIVES: Bordetella pertussis is a highly contagious respiratory agent and is the causative pathogen of pertussis, which primarily affects children. Current diagnostic techniques for this pathogen have a variety of limitations including a long culture time, low bacterial load, and lack of specificity. METHODS: This article reports the development of a one-tube nested quantitative real-time PCR assay using the locked nucleic acid (LNA) technique (LNA-OTN-q-PCR), targeting the BP485 gene and using a simple inexpensive extraction method. A total of 130 clinical samples from patients with clinically suspected pertussis, collected from the Children's Hospital of Hebei, China, were tested by LNA-OTN-q-PCR assay. RT-PCR and two-step semi-nested PCR assays were performed in parallel for comparison. RESULTS: Only strains of B. pertussis were identified as positive, whereas all of the remaining strains were appropriately identified as negative by the LNA-OTN-q-PCR assay. A single copy per reaction can be detected by the LNA-OTN-q-PCR assay. Additionally, the sensitivity of this method was 100 times that of the RT-PCR assay (100 copies per reaction). Sixty-three of the 130 clinical samples were detected positive by LNA-OTN-q-PCR assay; in contrast, RT-PCR was able to detect only 41 positive samples. Following this, all 63 samples were positively identified by two-step semi-nested PCR. Compared with the two-step semi-nested PCR assay, both the specificity and sensitivity of the LNA-OTN-q-PCR assay using purified DNA and crude extract were 100%. CONCLUSIONS: This assay was able to detect B. pertussis infection with high sensitivity and specificity. This test shows great potential as a promising technique to detect B. pertussis in both clinical laboratories and public health settings.


Assuntos
Bordetella pertussis/isolamento & purificação , Oligonucleotídeos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Coqueluche/diagnóstico , Bordetella pertussis/genética , Criança , China , DNA Bacteriano , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Coqueluche/microbiologia
8.
J Med Virol ; 92(12): 3073-3080, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31981228

RESUMO

Multiplex real-time quantitative polymerase chain reaction (mRT-qPCR) assay is commonly used to detect respiratory viruses, however, the sensitivity is limited for most reports. A panel of locked nucleic acid based multiplex closed one-tube nested real-time PCR (mOTNRT-PCR) assay consisting of five separate internally controlled RT-qPCR assays was developed for detection of 14 respiratory viruses. The sensitivity and reproducibility of mOTNRT-PCR panel were evaluated using plasmid standards and the specificity was evaluated using clinical samples. The clinical performance of mOTNRT-PCR panel was further evaluated with 468 samples collected from patients with an acute respiratory infection and compared with individual real-time PCR (RT-qPCR) assay. The analytical sensitivities of mOTNRT-PCR panel ranged from 2 to 20 copies/reaction, and no cross-reaction with common respiratory viruses was observed. The coefficients of variation of intra-assay and inter-assay were between 0.35% and 8.29%. Totally 35 clinical samples detected by mOTNRT-PCR assay panel were missed by RT-qPCR and confirmed true positive by sequencing of nested PCR products. The mOTNRT-PCR assay panel provides a more sensitive and high-throughput method for the detection of 14 respiratory viruses.

9.
J Clin Virol ; 123: 104254, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31901884

RESUMO

BACKGROUND: Human adenovirus (HAdV) is a common pathogen in children that can cause acute respiratory tract infection (ARTI), but the molecular epidemiological and clinical information relating to HAdV among hospitalized children with ARTI are few reported in China. OBJECTIVES: To evaluate the epidemiological, clinical, and molecular characteristics of HAdV infections among hospitalized children with ARTI in Hebei, Northern China from June 2017 to May 2018. STUDY DESIGN: A 12-month longitudinal, retrospective study on HAdV, typed by nested polymerase chain reaction targeting the hexon gene's hypervariable region (typing was merely performed by sequencing of the hexon neutralization epitope and thus genotypes could not be identified unequivocally), associated with ARTI was performed. The epidemiological and clinical data of different types of HAdV were analyzed using statistical product and service solutions (SPSS) 21.0 software. RESULTS: HAdV was detected in 330 (3.71%) of the 8906 specimens, with most (88.48%, 292/330) HAdV-positives cases detected among children < 3 years old. HAdV were detected throughout the year with a higher prevalence in spring. 11 types were identified, with HAdV-2 (33.33%, 110/330) as the predominant type, followed by HAdV-3 (21.21%, 70/330) and HAdV-7 (13.94%, 46/330). Of the 330 HAdV-positive specimens, 247 (74.85%) were co-detected with other respiratory pathogens, most commonly rhinovirus (HRV) (58.7%, 145/247). Additionally, patients with HAdV-7 positive had longer duration of fever than HAdV-2 or -3 positive patients. CONCLUSIONS: During the study period, HAdV-2, HAdV-3 and HAdV-7 were the predominant types identified from children with ARTI in Hebei Province. Pediatric patients with HAdV-7 positive may not present more severe clinical outcome except a longer duration of fever.


Assuntos
Infecções por Adenovirus Humanos/epidemiologia , Adenovírus Humanos/genética , Hospitalização/estatística & dados numéricos , Infecções Respiratórias/virologia , Doença Aguda/epidemiologia , Infecções por Adenovirus Humanos/virologia , Adenovírus Humanos/classificação , Adenovírus Humanos/patogenicidade , Adolescente , Criança , Pré-Escolar , China/epidemiologia , Coinfecção/epidemiologia , Coinfecção/virologia , DNA Viral/genética , Feminino , Genótipo , Humanos , Lactente , Estudos Longitudinais , Masculino , Filogenia , Prevalência , Infecções Respiratórias/epidemiologia , Estudos Retrospectivos , Análise de Sequência de DNA
10.
BMC Infect Dis ; 19(1): 835, 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31601192

RESUMO

BACKGROUND: Increasing number of hospitalized children with community acquired pneumonia (CAP) is co-detected with Mycoplasma pneumoniae (Mp). The clinical characteristics and impact of Mp co-detected with other bacterial and/or viral pathogens remain poorly understood. The purpose of this study was to evaluate the demographic and clinical features of CAP children with Mp mono-detection and Mp co-detection. METHODS: A total of 4148 hospitalized children with CAP were recruited from January to December 2017 at the Children's Hospital of Hebei Province, affiliated to Hebei Medical University. A variety of respiratory viruses, bacteria and Mp were detected using multiple modalities. The demographic and clinical features of CAP children with Mp mono-detection and Mp co-detection were recorded and analyzed. RESULTS: Among the 110 CAP children with Mp positive, 42 (38.18%) of them were co-detected with at least one other pathogen. Co-detection was more common among children aged ≤3 years. No significant differences were found in most clinical symptoms, complications, underlying conditions and disease severity parameters among various etiological groups, with the following exceptions. First, prolonged duration of fever, lack of appetite and runny nose were more prevalent among CAP children with Mp-virus co-detection. Second, Mp-virus (excluding HRV) co-detected patients were more likely to present with prolonged duration of fever. Third, patients co-detected with Mp-bacteria were more likely to have abnormal blood gases. Additionally, CAP children with Mp-HRV co-detection were significantly more likely to report severe runny nose compared to those with Mp mono-detection. CONCLUSION: Mp co-detection with viral and/or bacterial pathogens is common in clinical practice. However, there are no apparent differences between Mp mono-detection and Mp co-detections in terms of clinical features and disease severity.


Assuntos
Infecções Comunitárias Adquiridas/diagnóstico , Mycoplasma pneumoniae/isolamento & purificação , Pneumonia por Mycoplasma/diagnóstico , Bactérias/isolamento & purificação , Líquido da Lavagem Broncoalveolar/microbiologia , Criança , Criança Hospitalizada , Pré-Escolar , Infecções Comunitárias Adquiridas/microbiologia , DNA Bacteriano/metabolismo , Feminino , Humanos , Lactente , Masculino , Mycoplasma pneumoniae/genética , Pneumonia por Mycoplasma/microbiologia , Prevalência , Estudos Prospectivos , Vírus/isolamento & purificação
11.
Int J Infect Dis ; 86: 108-113, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31288091

RESUMO

OBJECTIVES: Pertussis is a highly transmissible acute respiratory infection caused by the bacterial pathogen Bordetella pertussis. The purpose of this study was to develop a rapid, simple and sensitive diagnostic test for detecting this pathogen. METHODS: Here we present a recombinase aided amplification (RAA) assay incorporating competitive internal amplification control (IAC) to detect Bordetella pertussis using the DNA obtained by boiling. This assay was performed in a single closed tube at 39°C within 30min. A total of 115 clinical samples suspected of pertussis were collected and tested by the internally controlled RAA assay using both extracted DNA with the commercial kit and the DNA obtained by boiling. For comparison, the real-time PCR (RT-PCR) was also performed with DNA extraction in parallel. RESULTS: The sensitivity of the internally controlled RAA assay was 101 copies or 10CFU/ml per reaction in detecting plasmid DNA or B. pertussis strain. The optimum concentration of the IAC plasmid was determined to be 100 copies, and the introduction of IAC effectively reduced the occurrence of false negatives. Compared to the RT-PCR, RAA results with DNA extraction obtained 100% sensitivity and specificity, and the RAA results with heat-treated DNA showed 85.96% sensitivity and 100% specificity. CONCLUSION: With the advantages of 45min turn-around time and simple steps of DNA purification, this assay could become a useful diagnostic tool for Bordetella pertussis detection and is potentially suitable for point-of-care identification to guide prompt clinical treatment.


Assuntos
Bordetella pertussis/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Recombinases , Coqueluche/diagnóstico , Bordetella pertussis/genética , Criança , Pré-Escolar , DNA Bacteriano/isolamento & purificação , Feminino , Temperatura Alta , Humanos , Lactente , Masculino , Técnicas de Amplificação de Ácido Nucleico/normas , Reação em Cadeia da Polimerase em Tempo Real , Padrões de Referência , Sensibilidade e Especificidade
12.
BMC Infect Dis ; 19(1): 229, 2019 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-30836947

RESUMO

BACKGROUND: Hepatitis B virus (HBV) infection is the major public health problem worldwide. In clinical practice, serological and molecular assays are the most commonly used diagnostic methods to detect HBV infection in clinical practices. METHODS: Here we present a rapid and sensitive recombinase aided amplification assay (RAA) to detect HBV at 39.0 °C for 30 min without DNA extraction from serum samples. The analytical sensitivity of RAA assay was 100 copies per reaction and showed no cross reaction with human immunodeficiency virus (HIV) and hepatitis C virus (HCV). The universality of RAA assay was validated by testing of 41 archived serum samples with predefined HBV genotypes (B, C and D). RESULTS: A total of 130 archived suspected HBV infected serum samples were detected by commercial qPCR with DNA extraction and RAA assay without DNA extraction (heat-treatment). Compared with qPCR assay as a reference, the RAA assay obtained 95.7% sensitivity and 100% specificity and a kappa value of 0.818. CONCLUSIONS: We developed a rapid, convenient, highly sensitive and specific method to detect HBV without DNA extraction in clinical samples. This RAA method of HBV detection is very suitable for clinical testing.


Assuntos
Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , Técnicas de Amplificação de Ácido Nucleico , Recombinases/metabolismo , Adulto , DNA Viral/isolamento & purificação , DNA Viral/metabolismo , Feminino , Hepatite B/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase em Tempo Real , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Arch Virol ; 164(1): 63-68, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30255299

RESUMO

Some serotypes of enterovirus (EV) may lead to transient and symptomatic gastrointestinal infections while others are commensal residents of the human gut. To determine whether certain EV types are more often associated with diarrhea, we conducted a preliminary study on the prevalence of EV serotypes and common diarrhea viruses in fecal samples of diarrhea children and healthy controls. EV was tested with one step nest polymerase chain reaction and typed by direct sequencing while common causative diarrhea viruses rotavirus (RV), norovirus (NoV), adenovirus (AdV), bocavirus (HBoV), and astrovirus (AstV) were screened with multiplex PCR assays. Human Rhinovirus (HRV) and human EVs that were present in both groups were further quantified and their odds ratios (OR) were calculated. Enteric pathogens were detected in 89 (32.6%) of 273 children with diarrhea and included human EVs (51, 18.68%), HRV (32, 11.72%), RV (38, 13.92%), AdV (24, 8.79%), NoVGII (16, 8.79%), HBoV (8, 2.93%) and AstV (3, 1.09%). Potential enteric pathogens were found in 25 (6.93%) of 361 healthy controls and included human EV (59, 16.34%), HRV (8, 2.22%), RV (1, 0.28%), NoVGII (5, 1.39%), AstV (2, 0.55%), AdV (16, 4.43%) and HBoV (1, 0.28%). In addition, EV71, echovirus 3,9,14,25 and coxsackievirus A14 existed in healthy controls only, while HRV, echovirus11,18, coxsackievirus A2,4,6 and B2,4 were found in both patients and healthy controls. OR assessment confirmed a strong association of HRV (P < 0.001) and a weak one for echovirus 11 and coxsackievirus A6 with diarrhea (P > 0.05). Our results indicate the diversity of EV serotypes in diarrhea and healthy control groups varies, and the potential etiological role of HRV in diarrhea.


Assuntos
Diarreia/virologia , Infecções por Enterovirus/virologia , Enterovirus/isolamento & purificação , Estudos de Casos e Controles , Pré-Escolar , Fezes/virologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino
14.
Diagn Microbiol Infect Dis ; 93(2): 101-106, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30266400

RESUMO

Respiratory syncytial virus (RSV) causes serious respiratory tract infection worldwide. The relatively low RSV load makes it difficult to detect in frail, elderly, and severely immune-compromised patients. In the present study, we developed a locked nucleic acid--based 1-tube nested real-time RT-PCR (OTNRT-PCR) assay with the advantages of extremely high sensitivity, facile operability, and less likelihood of cross-contamination. The sensitivity, specificity, and clinical performance of the OTNRT-PCR assay were compared in parallel with a conventional TaqMan probe-based real-time PCR (qRT-PCR) assay and a traditional 2-step nested RT-PCR assay. The limit of detection of the OTNRT-PCR assay was 1.02 × 10-1 TCID50/mL, equivalent to the traditional 2-step nested RT-PCR assay and 25-fold lower than the qRT-PCR assay. Of 616 nasopharyngeal aspirates tested, 143 RSV-negative samples by qRT-PCR were confirmed as positive by sequencing the OTNRT-PCR products. We therefore conclude that OTNRT-PCR is more sensitive than qRT-PCR for detection of RSV in clinical samples.


Assuntos
Oligonucleotídeos/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vírus Sincicial Respiratório Humano/genética , Primers do DNA/genética , Humanos , Limite de Detecção , Desnaturação de Ácido Nucleico , RNA Viral/análise , RNA Viral/genética , Vírus Sincicial Respiratório Humano/isolamento & purificação
15.
Virol J ; 15(1): 167, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30376870

RESUMO

BACKGROUND: Respiratory syncytial virus (RSV), human Rhinovirus (HRV) and human Metapneumo Virus (HMPV) are important viral pathogens causing acute respiratory tract infections in the hospitalized patients. Sensitive and accurate detection of RSV, HRV and HMPV is necessary for clinical diagnosis and treatment. RESULTS: A locked nucleic acid (LNA)-based multiplex closed one-tube nested real-time RT-PCR (mOTNRT-PCR) assay was developed for simultaneous detection of RSV, HRV and HMPV. The sensitivity, specificity, reproducibility and clinical performance of mOTNRT-PCR were evaluated and compared with individual real time PCR (RT-qPCR) assay using clinical samples. The analytical sensitivity of mOTNRT-PCR assay was 5 copies/reaction for RSV, HRV and HMPV, respectively, and no cross-reaction with other common respiratory viruses was observed. The coefficients of variation (CV) of intra-assay and inter-assay were between 0.51 to 3.67%. Of 398 nasopharyngeal aspirates samples tested, 109 (27.39%), 150 (37.69%) and 44 (11.06%) were positive for RSV, HRV and HMPV, respectively, whereas 95 (23.87%), 137 (34.42%) and 38 (9.55%) were positive for RSV, HRV and HMPV, respectively, by individual RT-qPCR assay. Thirty three samples that were positive by mOTNRT-PCR but negative by RT-qPCR were confirmed as true positives by sequencing using reported traditional two-step nested PCR assay. CONCLUSION: mOTNRT-PCR assay reveals extremely higher sensitivity than that of RT-qPCR assay for detecting RSV, HRV and HMPV in clinical settings.


Assuntos
Metapneumovirus/isolamento & purificação , Infecções por Paramyxoviridae/diagnóstico , Infecções por Picornaviridae/diagnóstico , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vírus Sincicial Respiratório Humano/isolamento & purificação , Rhinovirus/isolamento & purificação , Doença Aguda , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Metapneumovirus/genética , Reação em Cadeia da Polimerase Multiplex , Nasofaringe/virologia , Reprodutibilidade dos Testes , Vírus Sincicial Respiratório Humano/genética , Rhinovirus/genética , Sensibilidade e Especificidade
16.
BMC Infect Dis ; 18(1): 450, 2018 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-30176819

RESUMO

BACKGROUND: Diarrhea is a major source of morbidity and mortality among young children in low-income and middle-income countries. Human adenoviruses (HAdV), particular HAdV species F (40, 41) has been recognized as important causal pathogens, however limited data exist on molecular epidemiology of other HAdV associated with acute gastroenteritis. METHODS: In the present preliminary study, we performed a case-control study involving 273 children who presented diarrheal disease and 361 healthy children matched control in Children's hospital of Hebei Province (China) to investigate the relationship between non-enteric HAdV and diarrhea. HAdV were detected and quantified using quantitative real-time PCR (qPCR) and serotyped by sequencing and phylogenetic analysis. Odds ratio (OR) was used to assess the risk factor of HAdV. RESULTS: HAdV were detected in 79 (28.94%) of 273 children with diarrhea including 7 different serotypes (HAdV 40, 41, 3, 2,1,5 and 57) with serotypes 40, 41 and 3 being the most dominant and in 26 (7.20%) of 361 healthy children containing 9 serotypes (HAdV 40, 41, 3, 2,1,5,57,6 and 31). A majority (91.14%) of HAdV positives occurred in diarrhea children and 65.38% in controls< 3 years of age. No significant difference in the viral load was found between case and control groups or between Ad41-positive patients and healthy controls. In addition to HAdV 40 and 41, HAdV 3 was also associated with diarrhea (OR = 17.301, adjusted OR = 9.205, p < 0.001). CONCLUSIONS: Our results demonstrate a high diversity of HAdV present among diarrhea and healthy children and implicate that non-enteric HAdV3 may lead to diarrhea.


Assuntos
Infecções por Adenovirus Humanos/epidemiologia , Infecções por Adenovirus Humanos/virologia , Diarreia/epidemiologia , Diarreia/virologia , Infecções por Adenovirus Humanos/complicações , Adenovírus Humanos/genética , Adenovírus Humanos/isolamento & purificação , Adolescente , Estudos de Casos e Controles , Criança , Pré-Escolar , China/epidemiologia , Feminino , Gastroenterite/epidemiologia , Gastroenterite/virologia , Humanos , Lactente , Masculino , Epidemiologia Molecular , Filogenia , Reação em Cadeia da Polimerase em Tempo Real , Sorotipagem , Carga Viral
17.
Virol J ; 15(1): 81, 2018 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-29716642

RESUMO

BACKGROUND: Human adenovirus (HAdV) serotypes 2, 3 and 7 are more prevalent than other serotypes and have been associated with severe pneumonia in pediatric children. Molecular typing of HAdV is not routinely performed in clinical diagnostic laboratories as it is time-consuming and labor-intensive. METHODS: In the present study, we developed a triplex quantitative real-time PCR assay (tq-PCR) in a single closed tube for differential detection and quantitative analysis of HAdV serotypes 2, 3 and 7. The sensitivity, specificity, reproducibility and clinical performance of tq-PCR were evaluated. RESULTS: The analytical sensitivity of the tq-PCR was 100 copies/reaction for each of HAdV serotypes 2, 3 and 7, and no cross-reaction with other common respiratory viruses or HAdV serotypes 1,4,5,6,31,55 and 57 was observed. The coefficients of variation (CV) of intra-assay and inter-assay were between 0.6% to 3.6%. Of 138 previously-defined HAdV-positive nasopharyngeal aspirates samples tested, the detection agreement between tq-PCR and nested PCR was 96.38% (133/138). CONCLUSION: The proposed tq-PCR assay is a sensitive, specific and reproducible method and has the potential for clinical use in the rapid and differential detection and quantitation of HAdV serotypes 2, 3 and 7.


Assuntos
Adenovírus Humanos/genética , Tipagem Molecular/métodos , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por Adenovirus Humanos/virologia , Adenovírus Humanos/classificação , Adenovírus Humanos/isolamento & purificação , Criança , Pré-Escolar , Humanos , Lactente , Tipagem Molecular/instrumentação , Tipagem Molecular/normas , Reação em Cadeia da Polimerase Multiplex/normas , Nasofaringe/virologia , Variações Dependentes do Observador , Reação em Cadeia da Polimerase em Tempo Real/normas , Reprodutibilidade dos Testes , Infecções Respiratórias/virologia , Sensibilidade e Especificidade , Sorogrupo
18.
Diagn Microbiol Infect Dis ; 90(3): 181-185, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29273481

RESUMO

The sensitivity of qRT-PCR assay is not adequate for the detection of the samples with lower viral load, particularly in the cerebrospinal fluid (CSF) of patients. Here, we present the development of a highly sensitive real-time nested RT-PCR (RTN RT-PCR) assay in a single closed tube for detection of human enterovirus (HEV). The clinical performance of both RTN RT-PCR and qRT-PCR was also tested and compared using 140 CSF and fecal specimens. The sensitivities of RTN RT-PCR assay for EV71, Coxsackievirus A (CVA)16, CVA6 and CVA10 achieved 10-8 dilution with a corresponding Ct value of 38.20, 36.45, 36.75, and 36.45, respectively, which is equal to traditional two-step nested RT-PCR assay and approximately 2-10-fold lower than that of qRT-PCR assay. The specificity of RTN RT-PCR assay was extensively analyzed insilico and subsequently verified using the reference isolates and clinical samples. Sixteen qRT-PCR-negative samples were detected by RTN RT-PCR and a variety of enterovirus serotypes was identified by sequencing of inner PCR products. We conclude RTN RT-PCR is more sensitive than qRT-PCR for the detection of HEV in clinical samples.


Assuntos
Líquido Cefalorraquidiano/virologia , Encefalite/diagnóstico , Enterovirus Humano A/genética , Infecções por Enterovirus/diagnóstico , Meningite Viral/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , Pré-Escolar , Encefalite/virologia , Enterovirus Humano A/isolamento & purificação , Infecções por Enterovirus/virologia , Fezes/virologia , Humanos , Meningite Viral/virologia , RNA Viral/genética , Sensibilidade e Especificidade
19.
Diagn Microbiol Infect Dis ; 90(2): 90-95, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29141771

RESUMO

In this study, a rapid reverse-transcription recombinase aided amplification (RT-RAA) assay was developed to detect respiratory syncytial virus (RSV) subgroups A and B, respectively. The reaction was performed at 39°C in less than 30min. The analytical sensitivities of RSVA and RSVB at 95% probability by probit regression analysis were 38copies per reaction and 35 copies per reaction, respectively, and no cross reactions with other related respiratory viruses were observed. The RT-RAA assay was further utilized to detect and subgroup 306 clinical specimens and the results showed that 79(25.82%, 79/306) samples were positive for RSV, of those 16(20.25%, 16/79) were identified as RSVA and 63(79.75%, 63/79) were RSVB, which is completely consistent with the results obtained by RSV RT-qPCR assay. In conclusion, the developed RAA assay will be of benefit as a faster, sensitive and specific alternative tool for detection of RSV.


Assuntos
Tipagem Molecular/métodos , Infecções por Vírus Respiratório Sincicial/virologia , Vírus Sincicial Respiratório Humano/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Nasofaringe/virologia , RNA Viral/análise , Infecções por Vírus Respiratório Sincicial/diagnóstico , Sensibilidade e Especificidade , Virologia
20.
Diagn Microbiol Infect Dis ; 88(2): 115-119, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28365060

RESUMO

Respiratory Pathogen 13 Detection Kit (13× kit) is able to simultaneously detect 11 respiratory viruses, Mycoplasma pneumoniae (MP) and Chlamydia in a single reaction. Using 572 Nasopharyngeal aspirates collected from hospitalized children, the clinical performance of 13× kit for detecting 11 respiratory viruses was evaluated in comparison with a routinely used 2-tube multiplex reverse transcription PCR assay (2-tube assay) at provincial Centers for Disease Control and Prevention in China. The clinical performance of 13× kit for detecting MP and Chlamydia was evaluated by commercial real-time quantitative PCR (qPCR) kits or sequencing. For tested viruses, the assay concordance was 95.98% and the kappa coefficient was 0.89. All the MP and Chlamydia positive samples detected by 13× kit were confirmed as true positives. The utilization of the 13× kit in clinical settings will be helpful for doctors to assess clinical outcome according to virus type or multiple infections, and to limit the use of antibiotics.


Assuntos
Infecções por Chlamydia/diagnóstico , Chlamydia/genética , Mycoplasma pneumoniae/genética , Pneumonia por Mycoplasma/diagnóstico , Infecções Respiratórias/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Viroses/diagnóstico , Vírus/genética , Adolescente , Criança , Criança Hospitalizada , Pré-Escolar , Chlamydia/isolamento & purificação , Infecções por Chlamydia/microbiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Mycoplasma pneumoniae/isolamento & purificação , Líquido da Lavagem Nasal/microbiologia , Líquido da Lavagem Nasal/virologia , Pneumonia por Mycoplasma/microbiologia , Vírus/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA