Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
Int J Mol Sci ; 23(16)2022 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-36012237

RESUMO

Despite its discovery in the early 1970s, m6A modification within mRNA molecules has only powerfully entered the oncology field in recent years. This chemical modification can control all aspects of the maturation of mRNAs, both in the nucleus and in the cytoplasm. Thus, the alteration in expression levels of writers, erasers, and readers may significantly contribute to the alteration of gene expression observed in cancer. In particular, the activation of oncogenic pathways can lead to an alteration of the global rate of mRNA translation or the selective translation of specific mRNAs. In both cases, m6A can play an important role. In this review, we highlight the role of m6A in the regulation of translation by focusing on regulatory mechanisms and cancer-related functions of this novel but still controversial field.


Assuntos
Adenosina , Neoplasias , Adenosina/metabolismo , Humanos , Neoplasias/genética , Neoplasias/metabolismo , Neoplasias/terapia , Proteômica , RNA/metabolismo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
3.
Rev Neurol ; 55(3): 129-36, 2012 Aug 01.
Artigo em Espanhol | MEDLINE | ID: mdl-22825973

RESUMO

INTRODUCTION: Ankle brachial index (ABI) is not widespread in clinical practice because the need for specific equipment and training. Doing it without these requirements, quicker and with a cheaper method would facilitate their routine use. AIMS: To evaluate sensitivity and specificity of an automatic blood pressure device detecting ABI < 0.90, when technique is performed by nurses. To evaluate agreement between two techniques for the ABI determination. PATIENTS AND METHODS. Diagnostic accuracy study in 30 ischemic stroke patients. For each patient, three measurements were performed with the automatic device, and one with the reference method. RESULTS: The automatic blood pressure device performance detecting ABI < 0.90 was acceptable for each of the three measurements (sensitivity: 78%, 87% and 100%; specificity: 95%, 100% and 100%; positive predictive value: 87%, 100% and 100%; negative predictive value: 91%, 96% y 100%; accuracy: 90%, 97% y 100%). The intraclass correlation coefficients for intra-observer, inter-observer and inter-method variability showed acceptable levels, with results of 0.64, 0.83 and 0.75, respectively. In the Bland Altman test only inter-method comparison had less than 5% of its values out of range. CONCLUSIONS: Sensitivity and specificity of an automatic blood pressure device detecting ABI < 0.90 shows acceptable levels when technique is performed by nurses. This suggests its potential as screening tool in transient ischemic attack/ischemic stroke patients.


Assuntos
Índice Tornozelo-Braço/instrumentação , Isquemia Encefálica/diagnóstico , Esfigmomanômetros , Idoso de 80 Anos ou mais , Automação , Isquemia Encefálica/enfermagem , Isquemia Encefálica/fisiopatologia , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/enfermagem , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia Doppler/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA