Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 12(8)2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-36005050

RESUMO

There is no consensus on the role of electromyographic analysis in detecting and characterizing the asymmetries of jaw muscle excitation in patients with temporomandibular disorders (TMD). To analyze the TMD patients (n = 72) in comparison with the healthy controls (n = 30), the surface electromyography (sEMG) of the temporalis anterior muscle (TA) and masseter muscle (M) was recorded while a maximal biting task was performed. The differences in the asymmetry of the relationship between the masseter muscles were assessed in a module to determine the sensitivity (Sn) of binomial logistic models, based on the dominance of the TA or the M muscle, in accurately predicting the presence of TMD. All assumptions were met, and comparisons between the groups showed significant differences for the TA muscle ratio (p = 0.007), but not for the M muscle ratio (p = 0.13). The left side was predominant over the right side in the TMD group for both the TA (p = 0.02) and M muscles (p = 0.001), while the non-TMD group had a higher frequency of the right side. Binary logistic regression showed a significant model (χ2 = 9.53; p = 0.002) for the TA muscle with Sn = 0.843. The model for the M muscle also showed significance (χ2 = 8.03; p = 0.005) with Sn = 0.837. The TMD patients showed an increased TA muscle ratio and asymmetry of left dominance, compared to the healthy subjects. Both of the binomial logistic models, based on muscle dominance TA or M, were moderately sensitive for predicting the presence of TMD.


Assuntos
Músculo Temporal , Transtornos da Articulação Temporomandibular , Eletromiografia , Feminino , Humanos , Músculo Masseter/fisiologia , Músculo Temporal/fisiologia
2.
Diagnostics (Basel) ; 12(1)2022 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-35054353

RESUMO

The objective was to assess the instrumental validity and the test-retest reliability of a low-cost hand-held push dynamometer adapted from a load-cell based hanging scale (tHHD) to collect compressive forces in different ranges of compressive forces. Three independent raters applied 50 pre-established compressions each on the tHHD centered on a force platform in three distinct ranges: ~70 N, ~160 N, ~250 N. Knee isometric strength was also assessed on 19 subjects in two sessions (48 h apart) using the tHHD anchored by an inelastic adjustable strap. Knee extension and flexion were assessed with the participant seated on a chair with the feet resting on the floor, knees, and hips flexed at 90°. The isometric force peaks were recorded and compared. The ICC and the Cronbach's α showed excellent consistency and agreement for both instrumental validity and test-retest reliability (range: 0.89-0.99), as the correlation and determination coefficients (range: 0.80-0.99). The SEM and the MDC analysis returned adequate low values with a coefficient of variation less than 5%. The Bland-Altman results showed consistency and high levels of agreement. The tHHD is a valid method to assess the knee isometric strength, showing portability, cost-effectiveness, and user-friendly interface to provide an effective form to assess the knee isometric strength.

3.
J Sport Rehabil ; 29(8): 1218-1221, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32028259

RESUMO

CONTEXT: Strength assessment is essential to prescribe exercise in sports and rehabilitation. Low-cost valid equipment may allow continuous monitoring of training. OBJECTIVE: To examine the validity of a very low-cost hanging scale by comparing differences in the measures of peak force to a laboratory grade load cell during shoulder abduction, flexion, extension, and internal and external rotations. DESIGN: Analytical study. PARTICIPANTS: Thirty-two healthy subjects (18 women, age 26 [10] y, height 172 [8] cm, mass 69 [13] kg, body mass index 23 [4] kg/m2). MAIN OUTCOME MEASURES: The dependent variable was the maximal peak force (in kilogram-force). The independent variable was the instrument (laboratory grade load cell and hanging scale). RESULTS: No differences were observed while comparing the results. The intraclass correlation coefficients1,1 ranged from .96 to .99, showing excellent results. The Cronbach alpha test also returned >.99 for all comparisons. The SEM ranged from 0.02 to 0.04 kgf, with an averaged SD from 0.24 to 0.38 kgf. The correlation was classified as high for all tested movements (r > .99; P < .001), with excellent adjusted coefficients of determination (.96 < r2 < .99). Bland-Altman results showed high levels of agreement with bias ranging from 0.27 to 0.48. CONCLUSIONS: Hanging scale provides valid measures of isometric strength with similar output measures as laboratory grade load cell.


Assuntos
Contração Isométrica/fisiologia , Dinamômetro de Força Muscular/normas , Força Muscular/fisiologia , Articulação do Ombro/fisiologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Dinamômetro de Força Muscular/economia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA