Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Exp Biol Med (Maywood) ; 248(19): 1671-1683, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-38088106

RESUMO

The pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has raised awareness in the scientific community about the importance of being prepared for sanitary emergencies. Many measures implemented during the COVID pandemic are now being expanded to other applications. In the field of molecular and immunological diagnostics, the need to massively test the population worldwide resulted in the application of a variety of methods to detect viral infection. Besides gold standard reverse transcription quantitative polymerase chain reaction (RT-qPCR), the use of reverse transcription loop-mediated isothermal amplification (RT-LAMP) arose as an alternative and sensitive method to amplify and detect viral genetic material. We have used openly available protocols and have improved the protein production of RT-LAMP enzymes Bst polymerase and HIV-reverse transcriptase. To optimize enzyme production, we tested different protein tags, and we shortened the protein purification protocol, resulting in reduced processing time and handling of the enzymes and, thus, preserved the protein activity with high purity. The enzymes showed significant stability at 4 °C and 25 °C, over 60 days, and were highly reliable when used as a one-step RT-LAMP reaction in a portable point-of-care device with clinical samples. The enzymes and the reaction setup can be further expanded to detect other infectious diseases agents.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , DNA Polimerase Dirigida por RNA , Sensibilidade e Especificidade , SARS-CoV-2/genética , Técnicas de Diagnóstico Molecular/métodos , Testes Imediatos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Teste para COVID-19
2.
Diagnostics (Basel) ; 13(10)2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37238184

RESUMO

The complete blood count (CBC) is a highly requested test that is generally restricted to centralized laboratories, which are limited by high cost, being maintenance-demanding, and requiring costly equipment. The Hilab System (HS) is a small, handheld hematological platform that uses microscopy and chromatography techniques, combined with machine learning (ML) and artificial intelligence (AI), to perform a CBC test. This platform uses ML and AI techniques to add higher accuracy and reliability to the results besides allowing for faster reporting. For clinical and flagging capability evaluation of the handheld device, the study analyzed 550 blood samples of patients from a reference institution for oncological diseases. The clinical analysis encompassed the data comparison between the Hilab System and a conventional hematological analyzer (Sysmex XE-2100) for all CBC analytes. The flagging capability study compared the microscopic findings from the Hilab System and the standard blood smear evaluation method. The study also assessed the sample collection source (venous or capillary) influences. The Pearson correlation, Student t-test, Bland-Altman, and Passing-Bablok plot of analytes were calculated and are shown. Data from both methodologies were similar (p > 0.05; r ≥ 0.9 for most parameters) for all CBC analytes and flagging parameters. Venous and capillary samples did not differ statistically (p > 0.05). The study indicates that the Hilab System provides humanized blood collection associated with fast and accurate data, essential features for patient wellbeing and quick physician decision making.

3.
Sci Rep ; 13(1): 4690, 2023 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-36949174

RESUMO

Lateral flow antigen tests have been widely used in the Covid-19 pandemic, allowing faster diagnostic test results and preventing further viral spread through isolation of infected individuals. Accomplishment of this screening must be performed with tests that show satisfactory sensitivity in order to successfully detect the target protein and avoid false negatives. The aim of this study was to create a lateral flow test that could detect SARS-CoV-2 nucleocapsid protein in low concentrations that were comparable to the limits of detection claimed by existing tests from the market. To do so, several adjustments were necessary during research and development of the prototypes until they were consistent with these criteria. The proposed alternatives of increasing the test line antibody concentration and addition of an intermembrane between the conjugate pad and the nitrocellulose membrane were able to increase the sensitivity four-fold and generate a new rapid test prototype called "lateral flow intermembrane immunoassay test" (LFIIT). This prototype showed an adequate limit of detection (2.0 ng mL-1) while maintaining affordability and simplicity in manufacturing processes.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Pandemias , Sensibilidade e Especificidade , Nucleocapsídeo , Antígenos , Imunoensaio/métodos , Gossypium
4.
Sci Rep ; 12(1): 21424, 2022 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-36503901

RESUMO

The coronavirus pandemic accentuated the need for molecular diagnostic tests. A technique highly used to this end is the Polymerase Chain Reaction (PCR)-a sensitive and specific technique commonly used as the gold standard for molecular diagnostics. However, it demands highly trained personnel and high-maintenance equipment and is relatively time-consuming. An alternative is the Loop-Mediated Isothermal Amplification (LAMP) technique, which doesn't need sample purification or expensive equipment, and is similar to PCR when compared in sensitivity and specificity. In this paper, we developed an optimized colorimetric Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) Point-of-Care test using a portable device to diagnose COVID-19. Variables such as concentration of primers, magnesium sulfate, betaine, hydrochloride guanidine, Bst, and temperature of the reactions were tested. We also created a pipetting quality control system-using a combination of dyes-to avoid false negatives due to a lack of samples added to the reaction test tube. Mineral oil was incorporated in the composition of the RT-LAMP reactions to avoid evaporation when a heating lid isn't available. The final RT-LAMP test is tenfold more sensitive when compared to the WarmStart Colorimetric Master mix from New England Biolabs with a sensitivity of 5 copies per µL.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular , Colorimetria
5.
Sci Rep ; 12(1): 10409, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35729182

RESUMO

The complete blood count (CBC) is one of the most requested tests by physicians. CBC tests, most realized in conventional hematological analyzers, are restricted to centralized laboratories due to frequent maintenance, large devices, and expensive costs required. On the other hand, most handheld CBC devices commercially available show high prices and are not liable to calibration or control procedures, which results in poor quality compared to standard hematology instruments. The Hilab system is a small-handed hematological platform that uses microscopy and chromatography techniques for blood cells and hematimetric parameters analysis through artificial intelligence, machine learning, and deep learning techniques. For clinical evaluation of the handheld CBC device, 450 blood samples were analyzed. The samples encompassed normal (82%) and pathological conditions (18%), such as thalassemias (2.2%), anemias (6.6%), and infections (9.2%). For all analytes, accuracy, precision, method comparison, and flagging capabilities of the Hilab System, were compared with the Sysmex XE-2100 (Sysmex, Japan) results. The sample source (venous and capillary) influences were also evaluated. Pearson correlation, Student t test, bias, and the Bland-Altman plot of each blood count analyte were calculated and shown. The significance level was set at p ≤ 0.05. For clinical evaluation, Hilab System and the Sysmex XE-2100 showed a strong correlation (r ≥ 0.9) for most evaluated parameters. In the precision study, analytes showed CV inside the limits established according to European Federation of Clinical Chemistry and Laboratory Medicine guidelines. The flagging capabilities of the Hilab system, compared to the manual microscopy technique, presented high sensibility, specificity, and accuracy. Venous and capillary samples (p > 0.05) do not differ statistically. Considering the need for point-of-care CBCs, the study indicated that the Hilab system provides fast, accurate, low cost, and robust analysis for reliable clinical use.


Assuntos
Hematologia , Internet das Coisas , Inteligência Artificial , Contagem de Células Sanguíneas/métodos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA