Polymers (Basel) ; 13(16)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34451224

RESUMO

Orthopaedic implants and temporary osteosynthesis devices are commonly based on Titanium (Ti). For short-term devices, cell-material contact should be restricted for easy removal after bone healing. This could be achieved with anti-adhesive plasma-fluorocarbon-polymer (PFP) films created by low-temperature plasma processes. Two different PFP thin film deposition techniques, microwave (MW) and radiofrequency (RF) discharge plasma, were applied to receive smooth, hydrophobic surfaces with octafluoropropane (C3F8) or hexafluorohexane (C6F6) as precursors. This study aimed at examining the immunological local tissue reactions after simultaneous intramuscular implantation of four different Ti samples, designated as MW-C3F8, MW-C6F6, RF-C3F8 and Ti-controls, in rats. A differentiated morphometric evaluation of the inflammatory reaction was conducted by immunohistochemical staining of CD68+ macrophages, CD163+ macrophages, MHC class II-positive cells, T lymphocytes, CD25+ regulatory T lymphocytes, NK cells and nestin-positive cells in cryosections of surrounding peri-implant tissue. Tissue samples were obtained on days 7, 14 and 56 for investigating the acute and chronical inflammation (n = 8 rats/group). Implants with a radiofrequency discharge plasma (RF-C3F8) coating exhibited a favorable short- and long-term immune/inflammatory response comparable to Ti-controls. This was also demonstrated by the significant decrease in pro-inflammatory CD68+ macrophages, possibly downregulated by significantly increasing regulatory T lymphocytes.

2.
J Biomed Mater Res B Appl Biomater ; 108(5): 1801-1813, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31774237

RESUMO

Antimicrobial coating of implant material with poly(hexamethylene biguanide) hydrochloride (PHMB) may be an eligible method for preventing implant-associated infections. In the present study, an antibacterial effective amount of PHMB is adsorbed on the surface of titanium alloy after simple chemical pretreatment. Either oxidation with 5% H2 O2 for 24 hr or processing for 2 hr in 5 M NaOH provides the base for the subsequent formation of a relatively stable self-assembled PHMB layer. Compared with an untreated control group, adsorbed PHMB produces no adverse effects on SaOs-2 cells within 48 hr cell culture, but promotes the initial attachment and spreading of the osteoblasts within 15 min. Specimens were inoculated with slime-producing bacteria to simulate a perioperative infection. Adsorbed PHMB reacts bactericidally against Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa after surface contact. Adhered SaOs-2 cells differentiate and produce alkaline phosphatase and deposit calcium within 4 days in a mineralization medium on PHMB-coated Ti6Al4V surfaces, which have been precontaminated with S. epidermidis. The presented procedures provide a simple method for generating biocompatibly and antimicrobially effective implant surfaces that may be clinically important.


Assuntos
Ligas/química , Antibacterianos/química , Biguanidas/química , Materiais Revestidos Biocompatíveis/química , Titânio/química , Fosfatase Alcalina/metabolismo , Antibacterianos/farmacologia , Biguanidas/farmacologia , Adesão Celular , Diferenciação Celular , Linhagem Celular , Proliferação de Células , Materiais Revestidos Biocompatíveis/metabolismo , Humanos , Osteoblastos/citologia , Próteses e Implantes , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus/efeitos dos fármacos , Propriedades de Superfície
3.
Polymers (Basel) ; 11(6)2019 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-31195717

RESUMO

Biomaterials should be bioactive in stimulating the surrounding tissue to accelerate the ingrowth of permanent implants. Chemical and topographical features of the biomaterial surface affect cell physiology at the interface. A frequently asked question is whether the chemistry or the topography dominates the cell-material interaction. Recently, we demonstrated that a plasma-chemical modification using allylamine as a precursor was able to boost not only cell attachment and cell migration, but also intracellular signaling in vital cells. This microwave plasma process generated a homogenous nanolayer with randomly distributed, positively charged amino groups. In contrast, the surface of the human osteoblast is negatively charged at -15 mV due to its hyaluronan coat. As a consequence, we assumed that positive charges at the material surface-provoking electrostatic interaction forces-are attractive for the first cell encounter. This plasma-chemical nanocoating can be used for several biomaterials in orthopedic and dental implantology like titanium, titanium alloys, calcium phosphate scaffolds, and polylactide fiber meshes produced by electrospinning. In this regard, we wanted to ascertain whether plasma polymerized allylamine (PPAAm) is also suitable for increasing the attractiveness of a ceramic surface for dental implants using Yttria-stabilized tetragonal zirconia.

4.
J Biomed Mater Res A ; 106(10): 2726-2734, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30051967

RESUMO

Biomaterials can cause a chronic local inflammation called foreign body reaction, with formation of foreign body giant cells (FBGC) by monocyte/macrophage fusion. However, FBGC appearance and role for biomaterials with different physicochemical properties are not yet fully understood. This study aimed at examining FBGC and inflammatory cells after intramuscular implantation of poly(l-lactide-co-d/l-lactide) (PLA) as membranes and uncoated electro-spun fiber meshes or meshes with a positively charged plasma-polymer coating into rats. After 7, 14 and 56 days, CD68+ and CD163+ macrophages, T lymphocytes, MHC-II+ cells, FBGC, and nestin-stained tissue area as regeneration marker were morphometrically analyzed. FBGC occurrence was primarily determined by material morphology, as their numbers for meshes were 10-fold higher during acute and 50-fold higher during chronic inflammation than for membranes but comparable between uncoated and coated meshes. CD68+ macrophages decreased around and within meshes, while CD163+ macrophages and MHC-II+ cells increased within meshes. T lymphocytes within meshes were higher for coated meshes, suggesting that the peri-implant tissue immunological response is also influenced by surface chemistry. FBGC were predominantly CD68+ and CD163- , and nestin-stained tissue area was negatively correlated with CD68+ monocytes/macrophages numbers and positively correlated with CD163+ macrophages numbers, highlighting differing roles in FBGC formation and tissue regeneration. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2726-2734, 2018.


Assuntos
Células Gigantes de Corpo Estranho/patologia , Inflamação/etiologia , Poliésteres/efeitos adversos , Poliésteres/química , Próteses e Implantes/efeitos adversos , Animais , Células Apresentadoras de Antígenos/metabolismo , Antígenos CD/metabolismo , Antígenos de Histocompatibilidade Classe II/metabolismo , Inflamação/patologia , Macrófagos/metabolismo , Masculino , Ratos Endogâmicos Lew , Propriedades de Superfície , Linfócitos T/metabolismo
5.
Cell Biosci ; 8: 22, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29588849

RESUMO

BACKGROUND: Biomaterial modifications-chemical and topographical-are of particular importance for the integration of materials in biosystems. Cells are known to sense these biomaterial characteristics, but it has remained unclear which physiological processes bio modifications trigger. Hence, the question arises of whether the dynamic of intracellular calcium ions is important for the characterization of the cell-material interaction. In our prior research we could demonstrate that a defined geometrical surface topography affects the cell physiology; this was finally detectable in a reduced intracellular calcium mobilization after the addition of adenosine triphosphate (ATP). RESULTS: This new contribution examines the cell physiology of human osteoblasts concerning the relative cell viability and the calcium ion dynamic on different chemical modifications of silicon-titanium (Ti) substrates. Chemical modifications comprising the coating of Ti surfaces with a plasma polymerized allylamine (PPAAm)-layer or with a thin layer of collagen type-I were compared with a bare Ti substrate as well as tissue culture plastic. For this purpose, the human osteoblasts (MG-63 and primary osteoblasts) were seeded onto the surfaces for 24 h. The relative cell viability was determined by colorimetric measurements of the cell metabolism and relativized to the density of cells quantified using crystal violet staining. The calcium ion dynamic of osteoblasts was evaluated by the calcium imaging analysis of fluo-3 stained vital cells using a confocal laser scanning microscope. The positively charged nano PPAAm-layer resulted in enhanced intracellular calcium ion mobilization after ATP-stimulus and cell viability. This study underlines the importance of the calcium signaling for the manifestation of the cell physiology. CONCLUSIONS: Our current work provides new insights into the intracellular calcium dynamic caused by diverse chemical surface compositions. The calcium ion dynamic appears to be a sensitive parameter for the cell physiology and, thus, may represent a useful approach for evaluating a new biomaterial. In this regard, reliable in vitro-tests of cell behavior at the interface to a material are crucial steps in securing the success of a new biomaterial in medicine.

6.
J Cell Sci ; 131(1)2018 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-29122983

RESUMO

The topographical and chemical surface features of biomaterials are sensed by the cells, affecting their physiology at the interface. When placed on titanium, we recently discovered osteoblasts attempted caveolae-mediated phagocytosis of the sharp-edged microstructures. This active, energy-consuming process resulted in decreased osteoblastic cell functions (e.g. secretion of extracellular matrix proteins). However, chemical modification with plasma polymerized allylamine (PPAAm) was able to amplify osteoblast adhesion and spreading, resulting in better implant osseointegration in vivo In the present in vitro study, we analyzed whether this plasma polymer nanocoating is able to attenuate the microtopography-induced changes of osteoblast physiology. On PPAAm, we found cells showed a higher cell interaction with the geometrical micropillars by 30 min, and a less distinct reduction in the mRNA expression of collagen type I, osteocalcin and fibronectin after 24 h of cell growth. Interestingly, the cells were more active and sensitive on PPAAm-coated micropillars, and react with a substantial Ca2+ ion mobilization after stimulation with ATP. These results highlight that it is important for osteoblasts to establish cell surface contact for them to perform their functions.


Assuntos
Adesão Celular , Materiais Revestidos Biocompatíveis/química , Proteínas da Matriz Extracelular/metabolismo , Expressão Gênica , Osteoblastos/citologia , Alilamina/química , Linhagem Celular , Colágeno Tipo I/metabolismo , Fibronectinas/metabolismo , Humanos , Osteoblastos/metabolismo , Osteocalcina/metabolismo , Polimerização , RNA Mensageiro/análise , Propriedades de Superfície , Titânio/química
7.
J Funct Biomater ; 8(3)2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-28726761

RESUMO

Copper (Cu) could be suitable to create anti-infective implants based on Titanium (Ti), for example by incorporating Cu into the implant surface using plasma immersion ion implantation (Cu-PIII). The cytotoxicity of Cu might be circumvented by an additional cell-adhesive plasma polymerized allylamine film (PPAAm). Thus, this study aimed to examine in vivo local inflammatory reactions for Ti6Al4V implants treated with Cu-PIII (Ti-Cu), alone or with an additional PPAAm film (Ti-Cu-PPAAm), compared to untreated implants (Ti). Successful Cu-PIII and PPAAm treatment was confirmed with X-ray Photoelectron Spectroscopy. Storage of Ti-Cu and Ti-Cu-PPAAm samples in double-distilled water for five days revealed a reduction of Cu release by PPAAm. Subsequently, Ti, Ti-Cu and Ti-Cu-PPAAm samples were simultaneously implanted into the neck musculature of 24 rats. After 7, 14 and 56 days, peri-implant tissue was retrieved from 8 rats/day for morphometric immunohistochemistry of different inflammatory cells. On day 56, Ti-Cu induced significantly stronger reactions compared to Ti (tissue macrophages, antigen-presenting cells, T lymphocytes) and to Ti-Cu-PPAAm (tissue macrophages, T lymphocytes, mast cells). The response for Ti-Cu-PPAAm was comparable with Ti. In conclusion, PPAAm reduced the inflammatory reactions caused by Cu-PIII. Combining both plasma processes could be useful to create antibacterial and tissue compatible Ti-based implants.

8.
ACS Appl Mater Interfaces ; 9(12): 10461-10471, 2017 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-28296389

RESUMO

Topographical and chemical features of biomaterial surfaces affect the cell physiology at the interface and are promising tools for the improvement of implants. The dominance of the surface topography on cell behavior is often accentuated. Striated surfaces induce an alignment of cells and their intracellular adhesion-mediated components. Recently, it could be demonstrated that a chemical modification via plasma polymerized allylamine was not only able to boost osteoblast cell adhesion and spreading but also override the cell alignment on stochastically machined titanium. In order to discern what kind of chemical surface modifications let the cell forget the underlying surface structure, we used an approach on geometric microgrooves produced by deep reactive ion etching (DRIE). In this study, we systematically investigated the surface modification by (i) methyl-, carboxyl-, and amino functionalization created via plasma polymerization processes, (ii) coating with the extracellular matrix protein collagen-I or immobilization of the integrin adhesion peptide sequence Arg-Gly-Asp (RGD), and (iii) treatment with an atmospheric pressure plasma jet operating with argon/oxygen gas (Ar/O2). Interestingly, only the amino functionalization, which presented positive charges at the surface, was able to chemically disguise the microgrooves and therefore to interrupt the microtopography induced contact guidance of the osteoblastic cells MG-63. However, the RGD peptide coating revealed enhanced cell spreading as well, with fine, actin-containing protrusions. The Ar/O2-functionalization demonstrated the best topography handling, e.g. cells closely attached even to features such as the sidewalls of the groove steps. In the end, the amino functionalization is unique in abrogating the cell contact guidance.


Assuntos
Adesão Celular , Materiais Biocompatíveis , Osteoblastos , Propriedades de Superfície , Titânio
9.
Mater Sci Eng C Mater Biol Appl ; 69: 1116-24, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27612809

RESUMO

Excellent osseointegration of permanent implants is crucial for the long lasting success of the implantation. To improve the osseointegrative potential, bio-inert titanium alloy surfaces (Ti6Al4V) are modified by plasma chemical oxidation (PCO®) of the titanium-oxide layer to a non-stoichiometric, amorphous calcium phosphate layer. The native titanium-oxide film measuring only a few nanometers is converted by PCO® to a thick porous calcium phosphate layer of about 10µm. In a second step the PCO surface is combined with a cell adhesive plasma-polymerized allylamine (PPAAm) nano film (5 and 50nm). Independent of the PPAAm coating homogeneity, the human osteoblast-like MG-63 cells show a remarkable increase in cell size and well-developed filopodia. Analyses of the actin cytoskeleton reveal that the cells mold to the pore shape of the PPAAm-covered PCO, thereby establishing a strong attachment to the surface. Interestingly, we could demonstrate that even though our untreated PCO shows excellent hydrophilicity, this alone is not sufficient to facilitate fast cell spreading, but the positive surface charges mediated by PPAAm. This multilayer composite material guarantees enhanced interlocking of the cells with the porous surface.


Assuntos
Cerâmica/química , Materiais Revestidos Biocompatíveis/química , Polímeros/química , Citoesqueleto de Actina/efeitos dos fármacos , Ligas , Alilamina/química , Fosfatos de Cálcio/química , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Microscopia Eletrônica de Varredura , Oxirredução , Espectroscopia Fotoeletrônica , Porosidade , Propriedades de Superfície , Titânio/química
10.
Biomed Res Int ; 2015: 103137, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064874

RESUMO

A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.). Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 (p < 0.002) was found between 3D and 2D quantification of BIC. The µCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.


Assuntos
Materiais Revestidos Biocompatíveis , Osseointegração , Próteses e Implantes , Titânio , Algoritmos , Ligas , Animais , Etilenodiaminas , Feminino , Imageamento Tridimensional , Teste de Materiais , Poliaminas , Ratos , Ratos Sprague-Dawley , Tíbia/diagnóstico por imagem , Tíbia/patologia , Tíbia/cirurgia , Microtomografia por Raio-X
11.
J Mater Sci Mater Med ; 26(3): 131, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25698342

RESUMO

Implantation of biomaterials can cause complications often associated with inflammatory reactions. However, repeated evaluation of the implant site would be burdening for patients. Alternatively, blood examinations with analysis of inflammatory serum markers could potentially be useful to reflect the local cellular response for detection and/or prediction of inflammation-related complications. Therefore, following intramuscular implantation of surface-modified Ti implants in rats, this study aimed at examining possible associations between the post-implantation time course of pro-inflammatory (INFγ, IL-2) and anti-inflammatory (IL-4, IL-10) cytokine serum concentrations and the local peri-implant tissue response after 56 days (pro-inflammatory CD68-positive monocytes/macrophages, anti-inflammatory CD163-positive macrophages, MHC class II-positive cells, activated natural killer cells and mast cells). Multivariate correlation analysis revealed a significant interaction between serum IFNγ and peri-implant tissue CD68-positive monocytes/macrophages (p = 0.001) while no interactions were found for other cytokines and cell types. Additional Pearson correlation analysis of IFNγ serum concentrations on each experimental day vs. the CD68-positive monocytes/macrophages response on day 56 demonstrated a consistently positive correlation that was strongest during the first three weeks. Thus, high early pro-inflammatory IFNγ serum concentration was associated with high late number of pro-inflammatory CD68-positive monocyte/macrophages and low early serum IFNγ with low late CD68-positive monocyte/macrophage numbers. Further studies aimed at examination of patient samples could establish the relevance of this association to predict clinical complications. After implantation of titanium samples, high early IFNγ serum concentrations were associated with a pronounced late pro-inflammatory CD68-positive monocyte/ macrophage (red circle) response, while no correlation was found for other investigated cytokines and inflammatory cells (green circle). In contrast, low early IFNγ serum concentrations were correlated with low late monocyte/ macrophage numbers.


Assuntos
Implantes de Medicamento , Interferon gama/administração & dosagem , Macrófagos/imunologia , Animais , Ratos
12.
Langmuir ; 30(46): 13914-24, 2014 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-25356776

RESUMO

The long-term stability and γ-sterilisability of bioactive layers is the precondition for the application of implants. Thus, aging processes of a microwave deposited, plasma polymerized allylamine nanofilm (PPAAm) with positively charged amino groups were evaluated concerning physicochemical characteristics and cell adhesion capacity over the course of one year. XPS, FT-IR, surface free energy, and water contact angle measurements elucidated not only the oxidation of the PPAAm film due to atmospheric oxygen reacting with surface free radicals but also the influence of atmospheric moisture during sample storage in ambient air. Surprisingly, within 7 days 70% of the primary amino groups are lost and mostly converted into amides. A positive zeta-potential was verified for half a year and longer. Increasing polar surface groups and a water contact angle shift from 60° to 40° are further indications of altered surface properties. Nevertheless, MG-63 human osteoblastic cells adhered and spread out considerably on aged and additionally γ-sterilized PPAAm layers deposited on polished titanium alloys (Ti-6Al-4V_P). These cell-relevant characteristics were highly significant over the whole period of one year and may not be related to the existence of primary amino groups. Rather, the oxidation products, the chemical amide group, that is, seem to support the attachment of osteoblasts at all times up to one year.


Assuntos
Alilamina , Membranas Artificiais , Nanoestruturas/química , Osteoblastos/metabolismo , Gases em Plasma , Titânio , Ligas , Alilamina/química , Alilamina/farmacologia , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Teste de Materiais , Osteoblastos/citologia , Oxirredução , Fatores de Tempo , Titânio/química , Titânio/farmacologia
13.
Biomaterials ; 35(20): 5261-5277, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24703717

RESUMO

An effective amount of the antiseptic agent PHMB cannot simply be placed on the surface of titanium alloys where hydrocarbons were removed by different purification procedures. Pre-treatment of Ti6Al4V specimen with 5% H2O2 in 24 h results in extra introduced -OH and -COOH groups as well as an adsorbed water film on the surface, which provide the base for the subsequent formation of a relatively stable and multi-layered PHMB film. The superficially adhering PHMB film produces no adverse effects on MG63 cells within a 48 h-cell culture, but promotes the initial attachment and spreading of the osteoblasts on the modified Ti6Al4V surface within 15 min. After direct bacterial inoculation of the active sample, the PHMB film reacts antimicrobially against Gram-positive (Staphylococcus aureus, Staphylococcus epidermidis) and Gram-negative strains (Pseudomonas aeruginosa, Escherichia coli) after surface contact. The bactericidal efficacy is only slightly reduced after using of the same specimen for re-testing the antibacterial activity. MG63 cells adhere and proliferate within 48 h on a PHMB film-containing Ti6Al4V surface, which has been pre-contaminated with S. aureus. Bacterial biofilms were only revealed in controls without PHMB.


Assuntos
Biguanidas/farmacologia , Peróxido de Hidrogênio/química , Titânio/química , Molhabilidade/efeitos dos fármacos , Adsorção , Ligas , Antibacterianos/química , Antibacterianos/farmacologia , Anti-Infecciosos Locais/química , Anti-Infecciosos Locais/farmacologia , Biguanidas/química , Biofilmes , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Humanos , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus epidermidis/efeitos dos fármacos
14.
Int J Mol Sci ; 15(2): 2454-64, 2014 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-24521883

RESUMO

By means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V) coated with plasma-polymerized allylamine (PPAAm) and plasma-polymerized ethylenediamine (PPEDA) versus uncoated. Shear stress on human osteoblast-like MG-63 cells was investigated in vitro using a spinning disc device. Furthermore, bone-to-implant contact (BIC) was evaluated in vivo. Custom-made conical titanium implants were inserted at the medial tibia of female Sprague-Dawley rats. After a follow-up of six weeks, the BIC was determined by means of histomorphometry. The quantification of cell adhesion showed a significantly higher shear stress for MG-63 cells on PPAAm and PPEDA compared to uncoated Ti6Al4V. Uncoated titanium alloyed implants showed the lowest BIC (40.4%). Implants with PPAAm coating revealed a clear but not significant increase of the BIC (58.5%) and implants with PPEDA a significantly increased BIC (63.7%). In conclusion, plasma polymer coatings demonstrate enhanced cell adhesion and bone ongrowth compared to uncoated titanium surfaces.


Assuntos
Osseointegração , Polimerização , Próteses e Implantes , Titânio , Ligas , Animais , Adesão Celular , Linhagem Celular , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Osteoblastos/metabolismo , Ratos
15.
J Mater Sci Mater Med ; 24(3): 761-71, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23314622

RESUMO

Copper (Cu) could serve as antibacterial coating for Ti6Al4V implants. An additional cell-adhesive layer might compensate Cu cytotoxicity. This study aimed at in vitro and in vivo evaluation of low-temperature plasma treatment of Ti6Al4V plates with Ti/Cu magnetron sputtering (Ti6Al4V-Ti/Cu), plasma-polymerized ethylenediamine (Ti6Al4V-PPEDA), or both (Ti6Al4V-Ti/Cu-PPEDA). Ti6Al4V-Ti/Cu and Ti6Al4V-Ti/Cu-PPEDA had comparable in vitro Cu release and antibacterial effectiveness. Following intramuscular implantation of Ti6Al4V-Ti/Cu, Ti6Al4V-PPEDA, Ti6Al4V-Ti/Cu-PPEDA and Ti6Al4V controls for 7, 14 and 56 days with 8 rats/day, peri-implant tissue was immunohistochemically examined for different inflammatory cells. Ti6Al4V-PPEDA had more mast cells and NK cells than Ti6Al4V, and more tissue macrophages, T lymphocytes, mast cells and NK cells than Ti6Al4V-Ti/Cu-PPEDA. Ti6Al4V-Ti/Cu had more mast cells than Ti6Al4V and Ti6Al4V-Ti/Cu-PPEDA. Results indicate that PPEDA-mediated cell adhesion counteracted Cu cytotoxicity. Ti6Al4V-Ti/Cu-PPEDA differed from Ti6Al4V only for mast cells on day 56. Altogether, implants with both plasma treatments had antibacterial properties and did not increase inflammatory reactions.


Assuntos
Cobre/química , Etilenodiaminas/química , Inflamação/etiologia , Gases em Plasma , Titânio/efeitos adversos , Ligas , Animais , Biofilmes , Imuno-Histoquímica , Inflamação/imunologia , Linfócitos/imunologia , Masculino , Testes de Sensibilidade Microbiana , Ratos , Ratos Endogâmicos Lew , Staphylococcus aureus , Temperatura
16.
Acta Biomater ; 8(10): 3840-51, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22705633

RESUMO

Topographical and chemical modifications of biomaterial surfaces both influence tissue physiology, but unfortunately little knowledge exists as to their combined effect. There are many indications that rough surfaces positively influence osteoblast behavior. Having determined previously that a positively charged, smooth titanium surface boosts osteoblast adhesion, we wanted to investigate the combined effects of topography and chemistry and elucidate which of these properties is dominant. Polished, machined and corundum-blasted titanium of increasing microroughness was additionally coated with plasma-polymerized allylamine (PPAAm). Collagen I was then immobilized using polyethylene glycol diacid and glutar dialdehyde. On all PPAAm-modified surfaces (i) adhesion of human MG-63 osteoblastic cells increased significantly in combination with roughness, (ii) cells resemble the underlying structure and melt with the surface, and (iii) cells overcome the restrictions of a grooved surface and spread out over a large area as indicated by actin staining. Interestingly, the cellular effects of the plasma-chemical surface modification are predominant over surface topography, especially in the initial phase. Collagen I, although it is the gold standard, does not improve surface adhesion features comparably.


Assuntos
Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Gases em Plasma/química , Gases em Plasma/farmacologia , Titânio/química , Titânio/farmacologia , Citoesqueleto de Actina/efeitos dos fármacos , Citoesqueleto de Actina/metabolismo , Alilamina/química , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Nucléolo Celular/efeitos dos fármacos , Nucléolo Celular/metabolismo , Forma Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Microscopia Eletrônica de Varredura , Polimerização/efeitos dos fármacos , Propriedades de Superfície , Água/química
17.
J Mater Sci Mater Med ; 23(5): 1299-307, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22402792

RESUMO

Surface modification of Titanium (Ti) by low-temperature plasma influences cell-material interactions. Therefore, this study aimed at examining serum cytokine levels and associations after intramuscular implantation (n = 8 rats/group) of Ti-plates with Plasma Polymerized Allyl Amine (Ti-PPAAm), Plasma Polymerized Acrylic Acid (Ti-PPAAc), and without such layers (Ti-Controls). Pro-inflammatory (IL-2, IFNγ, IL-6) and anti-inflammatory (IL-4, IL-10, IL-13) cytokines were measured weekly for 56 days. Ti-PPAAm caused increased IL-2 (d7-14, d35), increased IFNγ (d35) and decreased IL-10 (d35, d49-56). Ti-PPAAc induced divergent anti-inflammatory cytokine changes with increased IL-4 (d28-56) and decreased IL-10 (d42-56). Ti-Controls elicited increased IL-2 (d42) and IFNγ (d35-42, d56). IL-6 was not detected and IL-13 only in three samples, thus they do not influence the response against these Ti implants. Correlation analysis revealed surface-dependent associations between cytokines indicating the involvement of different inflammatory cell populations. Concluding, different plasma modifications induce specific serum cytokine profiles and associations indicating distinct inflammatory responses.


Assuntos
Anti-Inflamatórios/sangue , Citocinas/sangue , Mediadores da Inflamação/sangue , Implantação de Prótese , Titânio/farmacologia , Animais , Anti-Inflamatórios/metabolismo , Materiais Revestidos Biocompatíveis/farmacologia , Lâmpadas de Polimerização Dentária , Citocinas/metabolismo , Equipamentos e Provisões/efeitos adversos , Mediadores da Inflamação/metabolismo , Masculino , Metaboloma/efeitos dos fármacos , Gases em Plasma/química , Gases em Plasma/farmacologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/reabilitação , Ratos , Ratos Endogâmicos Lew , Propriedades de Superfície , Titânio/química
18.
Bioinorg Chem Appl ; 2012: 850390, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22162672

RESUMO

New developments of antimicrobial implant surfaces doped with copper (Cu) ions may minimize the risk of implant-associated infections. However, experimental evaluation of the Cu release is influenced by various test parameters. The aim of our study was to evaluate the Cu release characteristics in vitro according to the storage fluid and surface roughness. Plasma immersion ion implantation of Cu (Cu-PIII) and pulsed magnetron sputtering process of a titanium copper film (Ti-Cu) were applied to titanium alloy (Ti6Al4V) samples with different surface finishing of the implant material (polished, hydroxyapatite and corundum blasted). The samples were submersed into either double-distilled water, human serum, or cell culture medium. Subsequently, the Cu concentration in the supernatant was measured using atomic absorption spectrometry. The test fluid as well as the surface roughness can alter the Cu release significantly, whereby the highest Cu release was determined for samples with corundum-blasted surfaces stored in cell medium.

19.
J Mater Sci Mater Med ; 22(4): 1015-26, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21455678

RESUMO

Implantation of biomaterials like titanium (Ti) causes inflammatory reactions possibly affecting implant functionality. Surface modifications could improve biocompatibility and functionality of implants. Biomembrane-derived phospholipids might be useful as implant coating due to their biomimetic properties. In vitro studies demonstrated beneficial effects for 2-oleoyl-1-palmitoyl-sn-glycero-3-phosphoethanolamin (POPE) as coating regarding interactions with cells and bacteria. Therefore, this in vivo study aimed at examining local inflammatory reactions after implantation of POPE-coated Ti plates. Ti implants with POPE attached non-covalently or covalent via octadecylphosphonic acid (OPA), with OPA alone and uncoated controls were simultaneously implanted intramuscularly in rats for 7, 14 and 56 days. The peri-implant tissue was quantitatively analyzed by immunohistochemistry for total macrophages, tissue macrophages, T cells, antigen-presenting cells and proliferating cells. Overall, both POPE-coated series were comparable to the controls. Furthermore, no differences were found between POPE coating on a covalently linked OPA monolayer and POPE coating dried from solution. Together with earlier in vitro results, this demonstrates the potential of phospholipids for implant surface modification.


Assuntos
Fosfolipídeos/química , Titânio/química , Animais , Materiais Biocompatíveis/química , Biomimética , Proliferação de Células , Humanos , Imuno-Histoquímica/métodos , Inflamação , Macrófagos/citologia , Teste de Materiais , Organofosfonatos/química , Fosfatidiletanolaminas/química , Ratos , Medicina Regenerativa/métodos , Fatores de Tempo
20.
Int J Artif Organs ; 33(10): 738-48, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21058265

RESUMO

PURPOSE: To improve orthopedic implant ingrowth, knowledge of the effect of chemical surface modifications on vital cell function in vitro is of importance. Early in our investigations we recognized that amino groups, positively charged via plasma polymerized allylamine, increased cell growth and the actin-filament formation in the initial cell-material contact phase. To gain insight into continuous vital cell behavior on this plasma polymer layer, here we present the metabolic activity of osteoblasts and their time-dependent adhesion using the sensor chip technology. METHODS: We demonstrate a new method for continuous 24 hour-measurements with vital human osteoblast-like cells (MG-63, ATCC) on sensor chips (Bionas® SC 1000) modified with plasma polymerized allylamine (PPAAm). The PPAAm film deposited on the chip is a cross-linked, strongly fixed plasma polymer with relatively high amino functionality and well defined chemical surface composition. We assessed continuous cell adhesion and the metabolic activity, i.e., oxygen consumption and acidification. RESULTS: We determined that adhesion of vital cells on PPAAm is not only enhanced shortly (1 h) after cell seeding but remained continuously higher for 24 h, which is significant. This nanometer-thin PPAAm layer did not change the overall metabolic activity of MG-63 cells during 24 h. CONCLUSION: This tool--using adhesion and metabolic sensor chips--appears to be a suitable method for the recognition of vital cell physiology in biocompatibility measurements of plasma chemical treated surfaces.


Assuntos
Alilamina/metabolismo , Técnicas Biossensoriais , Adesão Celular , Materiais Revestidos Biocompatíveis , Nanoestruturas , Osteoblastos/metabolismo , Consumo de Oxigênio , Gases em Plasma , Alilamina/química , Linhagem Celular Tumoral , Humanos , Concentração de Íons de Hidrogênio , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA