RESUMO
OBJECTIVE: To measure noise exposure present on pickleball courts and assess the risk of noise-induced hearing loss (NIHL) per guidelines put forward by the National Institute of Occupational Safety and Health (NIOSH). METHODS: Observational study measuring noise levels at multiple recreational pickleball courts in the Richmond, VA area, documenting LAeq, LASmax, and LCpeak at courtside and waiting areas of pickleball courts. Measurements were completed using the NIOSH SLM application on an iPhone 13 with iMM-6 Calibrated Measurement Microphone (equivalent to IEC 61672-1 Class II) that was calibrated using ND-9 Sound Level Calibrator (IEC942 Class I). RESULTS: Average sound levels recorded at waiting areas adjacent to the courts, measured in LAeq, LASmax, and LCpeak, were 69.1 dBA, 92.0 dBA, and 112.1 dBC, respectively, while courtside measurements were 69.7 dBA, 92.2 dBA, and 115.6 dBC, respectively. These measurements were within NIOSH and OSHA recommendations. CONCLUSION: The data demonstrates that randomly sampled pickleball courts have noise levels that do not increase risk for NIHL for participants or bystanders alike based on NIOSH guidelines. However, prolonged noise exposure and ambient noise pollution may have other health implications and warrant further investigations. LEVEL OF EVIDENCE: Level 2.
Assuntos
Perda Auditiva Provocada por Ruído , Humanos , Perda Auditiva Provocada por Ruído/etiologia , Estados Unidos , Esportes , National Institute for Occupational Safety and Health, U.S. , Ruído/efeitos adversos , Exposição Ambiental/efeitos adversosRESUMO
OBJECTIVES: Upper airway stimulation (UAS) is an effective treatment for patients with obstructive sleep apnea. The device consists of a stimulating electrode, an internal pulse generator, and a respiratory sensing lead. The purpose of this study is to characterize the incidence of sensing lead malfunction necessitating revision surgery in a high-volume center in conjunction with a review of the FDA Manufacturer and User Facility Device Experience (MAUDE) database reports on adverse events associated with the sensing lead component. METHODS: Patients age ≥18 implanted with the device were reviewed between July 2017 and June 2022. Those determined to have sensing lead malfunction were analyzed. The FDA MAUDE database was reviewed for reports associated with "Inspire Model 4323 Respiratory" and "Inspire Model 4340 Respiratory" between January 2014 and September 2022. RESULTS: One hundred ninety patients underwent UAS at our institution during the study period and four (2.1%) patients were found to have sensing lead malfunction. Analysis of the MAUDE database revealed 122 reports of adverse events associated with the sensing lead component, with 72% (88/122) of these requiring revision surgery. The most frequently reported adverse event was sensing lead tip separation from lead body, noted in 46% of these reports (56/122). CONCLUSION: The functionality of the sensing lead component is vital to the integrity of the UAS device and is measurable through waveform analysis. To provide optimal care after device implantation, it is essential to have a comprehensive understanding of the scenarios in which this component fails, the incidence of such events, and appropriate management. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1479-1484, 2024.
Assuntos
Apneia Obstrutiva do Sono , Humanos , Bases de Dados Factuais , Resultado do Tratamento , Estudos RetrospectivosRESUMO
Eagle Syndrome (ES) is a rare disorder that can present with symptoms ranging from globus sensation to otalgia that is attributed to an elongated styloid process and/or calcified stylohyoid ligament. No standardized treatment algorithm exists, and although various surgical approaches have been described, data on the use of transoral robotic surgery (TORS) in this population is limited. To investigate the utility of TORS in the treatment of ES, a retrospective review in 19 ES patients was carried out at a single academic, tertiary medical center between 2000 and 2017. Nineteen patients underwent twenty-one styloid resections: 6 performed via TORS and 15 via transcervical approach. Across all patients, 90% reported some degree of lasting improvement in symptoms while 55% reported significant improvement. When TORS was compared to transcervical resection, there was no difference in the subjective rate of "meaningful" (83 vs. 57%) versus rate of "non-meaningful" symptom improvement (17 vs. 43%) (pâ¯=â¯0.35). There was a trend towards less estimated blood loss (EBL), operative time, and post-operative length of stay (LOS) with TORS versus transcervical cases (9.2â¯mL vs. 30.0â¯mL, 98 vs. 156â¯min, and 0.7 vs. 1.2â¯days); however, these did not reach statistical significance (pâ¯=â¯.11, 0.13, and 0.42, respectively). Three patients experienced complications associated with an open approach, as compared to none with TORS. In select patients, TORS styloidectomy is a reasonable surgical alternative to traditional transoral and transcervical techniques as it provides similar symptom improvement, and reduced length of stay, blood loss, and operative time.
Assuntos
Ossificação Heterotópica/cirurgia , Procedimentos Cirúrgicos Otorrinolaringológicos/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Osso Temporal/anormalidades , Adulto , Perda Sanguínea Cirúrgica/prevenção & controle , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos/tendências , Osso Temporal/cirurgia , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: The effect of hip arthroscopy on athletic performance compared with preinjury levels for professional athletes in different sports remains unknown. In addition, while return rates have been reported for professional baseball, football, and hockey players, return rates have not been reported for professional basketball players. HYPOTHESIS: Professional athletes in 4 major North American sports would be able to return to their sport and preoperative level of performance at a high rate after arthroscopic hip surgery. STUDY DESIGN: Descriptive epidemiology study. METHODS: Major League Baseball (MLB), National Basketball Association (NBA), National Football League (NFL), and National Hockey League (NHL) athletes who underwent hip arthroscopy were identified through a previously reported protocol based on public sources. Successful return to play (RTP) was defined as returning for at least 1 professional regular season game after surgery. Performance scores were calculated by use of previously established scoring systems. Each player served as his own control, with the season prior to surgery defined as baseline. To make comparisons across sports, the authors adjusted for expected season and career length differences between sports and calculated percentage changes in performance. RESULTS: The authors identified 227 procedures performed on 180 professional athletes between 1999 and 2016. Successful RTP was achieved in 84.6% (192/227) of the procedures. Compared with all other athletes, NBA athletes returned at a similar rate (85.7%, P ≥ .999). NFL offensive linemen returned at a significantly lower rate than all other athletes (61.1%, P = .010). NHL athletes returned at a significantly higher rate than all other athletes (91.8%, P = .048) and demonstrated significantly decreased performance during postoperative season 1 compared with baseline (-35.1%, P = .002). Lead leg surgery for MLB athletes (batting stance for hitters, pitching stance for pitchers) resulted in a 12.7% reduction in hitter performance score ( P = .041), a 1.3% reduction in pitcher fastball velocity ( P = .004), and a 60.7% reduction in pitch count ( P = .007) one season after surgery compared with baseline. Players in nearly every sport demonstrated significant reductions in game participation after surgery. CONCLUSION: This study supports the hypothesis that hip arthroscopy in professional athletes is associated with excellent rates of return at the professional level. However, postoperative performance outcomes varied based on sport and position.