Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Arch Cardiovasc Dis ; 114(6-7): 455-464, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33846095

RESUMO

BACKGROUND: With the growing adult congenital heart disease (ACHD) population, the number of catheter ablation procedures is expected to dramatically increase. Data reporting experience and evolution of catheter ablation in patients with ACHD, over a significant period of time, remain scarce. AIM: We aimed to describe temporal trends in volume and outcomes of catheter ablation in patients with ACHD. METHODS: This was a retrospective observational study including all consecutive patients with ACHD undergoing attempted catheter ablation in a large tertiary referral centre over a 15-year period. Acute procedural success rate and freedom from recurrence at 12 and 24 months were analysed. RESULTS: From November 2004 to November 2019, 302 catheter ablations were performed in 221 patients with ACHD (mean age 43.6±15.0 years; 58.9% male sex). The annual number of catheter ablations increased progressively from four to 60 cases per year (P<0.001). Intra-atrial reentrant tachycardia/focal atrial tachycardia was the most common arrhythmia (n=217, 71.9%). Over the study period, acute procedural success rate increased from 45.0% to 93.4% (P<0.001). Use of irrigated catheters (odds ratio [OR] 4.03, 95% confidence interval [CI] 1.86-8.55), a three-dimensional mapping system (OR 3.70, 95% CI 1.72-7.74), contact force catheters (OR 3.60, 95% CI 1.81-7.38) and high-density mapping (OR 3.69, 95% CI 1.82-8.14) were associated with acute procedural success. The rate of freedom from any recurrence at 12 months increased from 29.4% to 66.2% (P=0.001). Seven (2.3%) non-fatal complications occurred. CONCLUSIONS: The number of catheter ablation procedures in patients with ACHD has increased considerably over the past 15 years. Growing experience and advances in ablative technologies appear to be associated with a significant improvement in acute and mid-term outcomes.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/tendências , Cardiopatias Congênitas/terapia , Padrões de Prática Médica/tendências , Sobreviventes , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
2.
J Thorac Cardiovasc Surg ; 151(1): 99-103, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26699770

RESUMO

OBJECTIVE: Tricuspid valve repair has been recently advocated in patients undergoing mitral valve surgery who have mild to moderate secondary tricuspid regurgitation. However, the incidence of heart conduction disorders after combined mitral valve and tricuspid valve interventions has not been evaluated. We sought to analyze the incidence of permanent pacemaker implantations and heart conduction disorders in patients undergoing mitral valve surgery with and without tricuspid valve annuloplasty. METHODS: In 2011 and 2012, among 201 consecutive patients referred to the Hôpital Européen Georges Pompidou for isolated nonischemic mitral valve disease, 113 underwent an isolated mitral valve procedure (group 1) and 88 had a concomitant tricuspid valve ring annuloplasty (group 2). RESULTS: Patients' mean age was 59.7 ± 16.5 years in group 1 and 60.7 ± 14.9 years in group 2 (P = .5). Mean crossclamp time and bypass time were 78 ± 35 minutes and 105 ± 47 minutes in group 1 and 92 ± 36 minutes and 128 ± 50 minutes in group 2, respectively (P = .001 and .005, respectively). Operative mortality was 3% (2.7% in group 1 and 3.2% in group 2, P = .4). Incidence of high-grade heart conduction disorders lasting more than 3 days postoperatively was 14.5% in group 1 and 41.2% in group 2 (P = .001). At 3 years, freedom from permanent pacemaker implantation was 99% ± 2% in group 1 and 94.1% ± 5% in group 2 (P = .02). For the entire cohort, longer crossclamp time (P = .02) and tricuspid ring annuloplasty (hazard ratio, 3.8; P = .001) were independent predictors of heart conduction disorders. CONCLUSIONS: The need for permanent pacemaker implantation is increased after concomitant tricuspid ring annuloplasty in the setting of mitral valve surgery. A clinical period of observation up to 14 days after postoperative heart conduction disorders should be observed before recommending permanent pacemaker placement.


Assuntos
Arritmias Cardíacas/etiologia , Anuloplastia da Valva Cardíaca/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Anuloplastia da Valva Cardíaca/mortalidade , Intervalo Livre de Doença , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Duração da Cirurgia , Marca-Passo Artificial , Paris , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia
3.
Circ J ; 79(1): 70-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25482295

RESUMO

BACKGROUND: Little is known about mid-term (3-month) postoperative atrial fibrillation (MT-POAF) in patients treated with bioprosthetic aortic valve replacement (BAVR). The aim of this study was to describe the natural history, identify the predictors and investigate the potential consequences in terms of anti-thrombotic therapy. METHODS AND RESULTS: During a longitudinal, prospective study, 219 patients were treated with BAVR early (7 days) and at mid-term postoperatively (30 and 90 days). POAF was monitored and risk factors were identified on logistic regression analysis. History of previous AF (OR, 3.08; 95% CI: 1.35-6.98), early POAF (OR, 5.93; 95% CI: 2.96-11.8), and BMI (per 5 kg/m(2): OR, 1.46; 95% CI: 1.03-2.09), were independent predictors for MT-POAF whereas sex, age and Euroscore were not. Results were identical when restricted to the 176 patients free from preoperative AF. In this subgroup, 36 patients (20.4%) had MT-POAF; 33 out of 174 (18.7%) would have required anticoagulation (CHA2DS2VASc score ≥ 1). Conversely, patients with BMI <27.7 and sinus rhythm at early follow-up had a very low risk of MT-POAF (OR, 0.16; 95% CI: 0.06-0.42). CONCLUSIONS: There was a higher than expected occurrence of MT-POAF in patients treated with BAVR, particularly in overweight patients with early POAF. This raises the question of implementing an anti-thrombotic therapy in these patients at higher risk of delayed atrial arrhythmia.


Assuntos
Valva Aórtica/cirurgia , Fibrilação Atrial/etiologia , Bioprótese , Fibrinolíticos/uso terapêutico , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/etiologia , Adiposidade , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Índice de Massa Corporal , Comorbidade , Diabetes Mellitus/epidemiologia , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Hipertensão/epidemiologia , Masculino , Obesidade/complicações , Complicações Pós-Operatórias/epidemiologia , Período Pós-Operatório , Estudos Prospectivos , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Fumar/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Trombofilia/epidemiologia , Trombofilia/etiologia
4.
Interact Cardiovasc Thorac Surg ; 16(1): 16-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23054907

RESUMO

OBJECTIVES: The diagnostic accuracy of multiplane bi-dimensional transoesophageal echocardiography (TEE) in detecting aortic valve bicuspidy is good, but is less reliable when the leaflets are moderately or severely calcified. We hypothesized that systolic colour Doppler analysis might improve the accuracy of diagnosing aortic bicuspidy by TEE in patients with severe symptomatic aortic stenosis (AS). METHODS: Two colour Doppler images of a stenotic aortic valve were defined in a preliminary study using multiplane TEE. In type I, the valve opening had a linear, angular or 'hanger-like' configuration and in type II it was more star-like or 'stellar'. The accuracy of this classification in detecting bicuspidy was evaluated. Fifty-one patients (mean age 71 years (range 40-90 years); 52% male) with severe symptomatic AS (defined as aortic valve area ≤1 cm(2)), requiring surgical aortic valve replacement, were included in this prospective study. The surgical findings were compared with the echocardiographic data. RESULTS: The incidence of aortic bicuspidy was 43%. The presence of type I colour Doppler configuration was significantly higher for bicuspid than for tricuspid aortic valves (95.5 vs 3.5%, respectively; P < 0.001). Diagnostic accuracy in detecting bicuspidy was high (sensitivity 95.5%; specificity 96.5%; positive predictive value 95.5%). Intra- and inter-observer agreements were excellent (Kappa coefficient = 0.88 and 0.92, respectively). CONCLUSIONS: Aortic valve bicuspidy may be accurately diagnosed by colour Doppler valve analysis during TEE in patients with severe AS. Larger prospective studies are required to confirm our results.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Feminino , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Paris/epidemiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA