Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
ACS Sens ; 8(2): 610-618, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36657059

RESUMO

Inhaled medications are commonplace for administering bronchodilators, anticholinergics, and corticosteroids. While they have a defined legitimate use, they are also used in sporting events as performance-enhancing drugs. These performance enhancers can be acquired via both legal (i.e., at a pharmacy through over-the-counter medications or through a prescription) and illicit (i.e., black market and foreign pharmacies) means, thus making monitoring procurement impossible. While urine tests can detect these pharmacological agents hours after they have been inhaled, there is a significant lag time before they are observed in urine. Direct detection of these inhaled agents is complicated and requires a multiplexed approach due to the sheer number of inhaled pharmacological agents. Therefore, detection of propellants, which carry the drug into the lungs, provides a simpler path forward toward detection of broad pharmacological agents. In this paper, we demonstrate the first use of terahertz spectroscopy (THz) to detect inhaled medications in human subjects. Notably, we were able to detect and quantitate the propellant, HFA-134a, in breath up to 30 min after using an asthma inhaler, enabling the use of a point-of-care device to monitor exhaled breath for the presence of propellants. We also demonstrate via simulations that the same approach can be leveraged to detect and identify next-generation propellants, specifically HFA-152a. As a result, we provide evidence that a single point-of-care THz sensor can detect when individuals have used pressure-mediated dose inhalers (pMDIs) without further modification of the hardware.


Assuntos
Asma , Espectroscopia Terahertz , Humanos , Propelentes de Aerossol/uso terapêutico , Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Broncodilatadores/química , Broncodilatadores/uso terapêutico
2.
PLoS One ; 13(10): e0205237, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30321194

RESUMO

OBJECTIVE: Postoperative lymphopenia has been proposed as a risk factor for postoperative infections but has never been identified as such in a multivariate analysis. Postoperative pneumonia (POP) is one of the most common complications after lung cancer surgery and is associated with a worse outcome. We aimed to evaluate the association between postoperative lymphopenia and POP after lung cancer surgery. METHODS: Patients admitted for lung cancer surgery (lobectomy, bilobectomy, or pneumonectomy) aged ≥ 18 years and with no history of an immunosuppressive state were eligible for inclusion. Lymphocyte counts were determined in blood drawn on the day before surgery and at postoperative days 1, 3 and 7. POP diagnosis was based on clinical, biological and radiological data. A logistic regression model adjusted on currently described risk factors for POP was used to explain the onset of this condition. RESULTS: Two hundred patients were included, of whom 43 (21.5%) developed POP. Preoperative lymphocyte count was 1.8±0.6x10(9) cells/L and 2.0±0.7x10(9) cells/L in patients with and without POP, respectively (P = .091). In both groups, the lymphocyte count nadir occurred at postoperative day 1. In multivariate analysis, lymphopenia at postoperative day 1 was significantly associated with increased risk of POP (odds ratio: 2.63, 95% CI [1.03-5.40]). POP rate at postoperative day 7 was higher in patients presenting low lymphocyte counts (≤1.19x10(9) cells/L) at postoperative day 1 (P = .003). CONCLUSIONS: Our study showed that lymphopenia following lung cancer surgery was maximal at postoperative day 1 and was associated with POP.


Assuntos
Neoplasias Pulmonares/cirurgia , Linfopenia/epidemiologia , Pneumonectomia/efeitos adversos , Pneumonia/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Pulmão/cirurgia , Contagem de Linfócitos , Linfopenia/sangue , Linfopenia/etiologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Pneumonectomia/métodos , Pneumonia/etiologia , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Estudos Retrospectivos , Fatores de Risco
3.
J Breath Res ; 11(4): 047111, 2017 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-29018179

RESUMO

Hypoxia-like incidents in-flight have increased over the past decade causing severe safety concerns across the aviation community. As a result, the need to monitor flight crews in real-time for the onset of hypoxic conditions is paramount for continued aeronautical safety. Here, hypoxic events were simulated in the laboratory via a reduced oxygen-breathing device to determine the effect of recovery gas oxygen concentration (21% and 100%) on exhaled breath volatile organic compound composition. Data from samples collected both serially (throughout the exposure), prior to, and following exposures yielded 326 statistically significant features, 203 of which were unique. Of those, 72 features were tentatively identified while 51 were verified with authentic standards. A comparison of samples collected serially between recovery and hypoxia time points shows a statistically significant reduction in exhaled breath isoprene (2-methyl-1,3-butadiene, log2 FC -0.399, p = 0.005, FDR = 0.034, q = 0.033), however no significant difference in isoprene abundance was observed when comparing recovery gases (21% or 100% O2, p = 0.152). Furthermore, examination of pre-/post-exposure 1 l bag breath samples illustrate an overall increase in exhaled isoprene abundance post-exposure (log2 FC 0.393, p = 0.005, FDR = 0.094, q = 0.033) but again no significant difference between recovery gas (21% and 100%, p = 0.798) was observed. A statistically significant difference in trend was observed between isoprene abundance and recovery gases O2 concentration when plotted against minimum oxygen saturation (p = 0.0419 100% O2, p = 0.7034 21% O2). Collectively, these results suggest exhaled isoprene is dynamic in the laboratory ROBD setup and additional experimentation will be required to fully understand the dynamics of isoprene in response to acute hypoxic stress.


Assuntos
Testes Respiratórios/métodos , Butadienos/análise , Expiração , Hemiterpenos/análise , Hipóxia/diagnóstico , Pentanos/análise , Estresse Fisiológico , Adulto , Humanos , Hipóxia/sangue , Masculino , Oxigênio/sangue , Padrões de Referência , Fatores de Tempo , Adulto Jovem
4.
J Occup Environ Hyg ; 14(6): 461-472, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28278066

RESUMO

U.S. Air Force small arms firing ranges began using copper-based, lead-free frangible ammunition in the early 2000s due to environmental and health concerns related to the use of lead-based ammunition. Exposure assessments at these firing ranges have routinely detected chemicals and metals in amounts much lower than their mass-based occupational exposure limits, yet, instructors report work-related health concerns including respiratory distress, nausea, and headache. The objective of this study at one firing range was to characterize the aerosol emissions produced by weapons during firing events and evaluate the ventilation system's effectiveness in controlling instructor exposure to these emissions. The ventilation system was assessed by measuring the range static air pressure differential and the air velocity at the firing line. Air flow patterns were near the firing line. Instructor exposure was sampled using a filter-based air sampling method for metals and a wearable, real-time ultrafine particle counter. Area air sampling was simultaneously performed to characterize the particle size distribution, morphology, and composition. In the instructor's breathing zone, the airborne mass concentration of copper was low (range = <1 µg/m3 to 16 µg/m3), yet the ultrafine (nanoscale) particle number concentration increased substantially during each firing event. Ultrafine particles contained some copper and were complex in morphology and composition. The ventilation assessment found that the average velocity across all shooting lanes was acceptable compared to the recommended guideline (20% of the ideal 0.38 m/s (75 ft/min). However, uniform, downrange airflow pattern requirements were not met. These results suggest that the mass-based occupational exposure limits, as applied to this environment, may not be protective enough to eliminate health complaints reported by instructors whose full-time job involves training personnel on weapons that fire lead-free frangible ammunition. Using an ultrafine particle counter appears to be an alternative method of assessing ventilation effectiveness in removing ultrafine particulate produced during firing events.


Assuntos
Poluentes Ocupacionais do Ar/análise , Armas de Fogo , Exposição Ocupacional/análise , Movimentos do Ar , Cobre/análise , Monitoramento Ambiental/métodos , Humanos , Militares , Nanopartículas/análise , Ohio , Tamanho da Partícula , Ventilação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA