Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
2.
J Nucl Med ; 64(7): 1125-1130, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37116914

RESUMO

Radioactive iodine is well established as a successful treatment for differentiated thyroid cancer (DTC), although around 15% of patients have local recurrence or develop distant metastases and may become refractory to radioactive iodine (RAI). A personalized approach to treatment, based on the absorbed radiation doses delivered and using treatments to enhance RAI uptake, has not yet been developed. Methods: We performed a multicenter clinical trial to investigate the role of selumetinib, which modulates the expression of the sodium iodide symporter, and hence iodine uptake, in the treatment of RAI-refractory DTC. The iodine uptake before and after selumetinib was quantified to assess the effect of selumetinib. The range of absorbed doses delivered to metastatic disease was calculated from pre- and posttherapy imaging, and the predictive accuracy of a theranostic approach to enable personalized treatment planning was investigated. Results: Significant inter- and intrapatient variability was observed with respect to the uptake of RAI and the effect of selumetinib. The absorbed doses delivered to metastatic lesions ranged from less than 1 Gy to 1,170 Gy. A strong positive correlation was found between the absorbed doses predicted from pretherapy imaging and those measured after therapy (r = 0.93, P < 0.001). Conclusion: The variation in outcomes from RAI therapy of DTC may be explained, among other factors, by the range of absorbed doses delivered. The ability to assess the effect of treatments that modulate RAI uptake, and to estimate the absorbed doses at therapy, introduces the potential for patient stratification using a theranostic approach. Patient-specific absorbed dose planning might be the key to more successful treatment of advanced DTC.


Assuntos
Neoplasias da Glândula Tireoide , Humanos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/tratamento farmacológico , Radioisótopos do Iodo/uso terapêutico , Radiometria , Diagnóstico por Imagem
3.
Q J Nucl Med Mol Imaging ; 67(1): 4-13, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36633588

RESUMO

The use of alpha emitting radiotherapeutics is increasing, with further growth expected due to a number of clinical trials currently running involving new alpha emitters. However, literature concerning radiation safety aspects of alpha emitting radionuclides is limited and most of the available literature concerns 223Ra. In general, the occupational exposure from alpha emitting radionuclides is expected to be low, as are doses to the public from external exposure. However, care must be taken to avoid skin contamination, inhalation, and ingestion. Not all alpha emitting radionuclides are identical, they often have very different associated decay chains and emissions. The decay chains and the manufacturing process should be carefully examined to identify any long-lived progeny or impurities. These may have an impact on the radiation safety processes required to limit occupational exposure and for waste management. Doses to the public must also be assessed, either arising directly from exposure to patients treated with radiotherapeutics, or via waste streams. Risk assessments should be in place when starting a new service covering all aspects of the preparation and administration, as well as any foreseeable incidents such as skin contamination or patient death, and the appropriate steps to take in these instances. It is imperative that with the increase in the use of alpha emitting radiotherapeutics more literature is published on radiation safety aspects, especially for new alpha emitting radiotherapeutics which often have very different characteristics than the currently established ones.


Assuntos
Proteção Radiológica , Humanos , Radioisótopos/efeitos adversos , Medição de Risco , Partículas alfa/efeitos adversos , Doses de Radiação
4.
Radiat Res ; 199(2): 202-210, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36583945
5.
EJNMMI Phys ; 9(1): 86, 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36512147

RESUMO

BACKGROUND: Accurate quantification of radioactivity in a source of interest relies on accurate registration between SPECT and anatomical images, and appropriate correction of partial volume effects (PVEs). For small volumes, exact registration between the two imaging modalities and recovery factors used to correct for PVE are unreliable. There is currently no guidance relating to quantification or the associated uncertainty estimation for small volumes. MATERIAL AND METHODS: A method for quantification of small sources of interest is proposed, which uses multiple oversized volumes of interest. The method was applied to three Na[131I]I activity distributions where a Na[131I]I capsule was situated within a cylindrical phantom containing either zero background, uniform background or non-uniform background and to a scenario with small lesions placed in an anthropomorphic phantom. The Na[131I]I capsule and lesions were quantified using the proposed method and compared with measurements made using two alternative quantification methods. The proposed method was also applied to assess the absorbed dose delivered to a bone metastasis following [131I]mIBG therapy for neuroblastoma including the associated uncertainty estimation. RESULTS: The method is accurate across a range of activities and in varied radioactivity distributions. Median percentage errors using the proposed method in no background, uniform backgrounds and non-uniform backgrounds were - 0.4%, - 0.3% and 1.7% with median associated uncertainties of 1.4%, 1.4% and 1.6%, respectively. The technique is more accurate and robust when compared to currently available alternative methods. CONCLUSIONS: The proposed method provides a reliable and accurate method for quantification of sources of interest, which are less than three times the spatial resolution of the imaging system. The method may be of use in absorbed dose calculation in cases of bone metastasis, lung metastasis or thyroid remnants.

6.
Eur J Nucl Med Mol Imaging ; 49(9): 3247-3256, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35320386

RESUMO

PURPOSE: Concern is growing about long-term side effects of differentiated thyroid cancer treatment, most notably radioactive iodine (RAI) therapy. However, published studies on the subject have had heterogeneous cohorts and conflicting results. This review seeks to provide an updated evaluation of published evidence, and to elucidate the risk of second primary malignancies (SPMs), especially secondary hematologic malignancies (SHMs), attributable to RAI therapy. METHODS: An extensive literature search was performed in Ovid MEDLINE, Ovid MEDLINE and In-Process & Other Non-Indexed Citations, Ovid MEDLINE Epub Ahead of Print, Cochrane Central Register of Controlled Trials (CENTRAL) and PubMed. Studies regarding RAI-induced SPMs or a dose-response relationship between RAI therapy and SPMs were identified, 10 of which were eligible for the analysis. We evaluated risk of bias in each study and judged quality of evidence (QOE) across all studies using the Grading of Recommendations, Assessment, Development and Evaluations approach. RESULTS: For the outcome "SPM", the relative effect (relative risk, hazard ratio, or odds ratio) of RAI vs. no RAI ranged from 1.14 to 1.84 across studies, but most results were not statistically significant. For the outcome "SHM", reported relative effects ranged from 1.30 to 2.50, with 2/3 of the studies presenting statistically significant results. In 7/8 of the studies, increased risk for SPM was shown with increasing cumulative RAI activity. QOE was "very low" regarding SPM after RAI and regarding a dose-response relationship, and "low" for SHM after RAI. CONCLUSION: Based on low quality evidence, an excess risk for the development of SPM cannot be excluded but is expected to be small.


Assuntos
Adenocarcinoma , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Neoplasias da Glândula Tireoide , Adenocarcinoma/complicações , Humanos , Radioisótopos do Iodo/efeitos adversos , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Risco , Neoplasias da Glândula Tireoide/radioterapia
7.
J Nucl Med ; 63(3): 485-492, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34353873

RESUMO

This paper presents standardized methods for performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. Special models for calculating time-activity integrals (urinary bladder, intestines) are also reviewed. This article can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates from animal or human data.


Assuntos
Análise de Dados , Compostos Radiofarmacêuticos , Animais , Cinética , Doses de Radiação , Radiometria/métodos
8.
J Nucl Med ; 63(2): 316-322, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34353875

RESUMO

This paper presents standardized methods for collecting data to be used in performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. This document can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates, from animal or human data.


Assuntos
Radiometria , Compostos Radiofarmacêuticos , Animais , Cinética , Doses de Radiação , Radiometria/métodos
9.
Thyroid ; 31(12): 1829-1838, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34598656

RESUMO

Background: Patients with Graves' disease are commonly treated with radioiodine. There remains controversy over whether the aim of treatment should be to achieve euthyroidism or hypothyroidism, and whether treatments should be administered with standard levels of radioactivity or personalized according to the radiation absorbed doses delivered to the thyroid. The aim of this review was to investigate whether a relationship exists between radiation absorbed dose and treatment outcome. Methods: A systematic review and meta-analysis of all reports published before February 13, 2020, were performed using PubMed, Web of Science, OVID MEDLINE, and Embase. Proportion of patients achieving nonhyperthyroid status was the primary outcome. Secondary outcomes were proportion of patients who were specifically euthyroid or hypothyroid. A random-effects meta-analysis of proportions was performed for primary and secondary outcomes, and the impact of the radiation absorbed dose on treatment outcome was assessed through meta-regression. The study is registered with PROSPERO (CRD42020175010). Results: A total of 1122 studies were identified of which 15, comprising 2303 Graves' disease patients, were eligible for the meta-analysis. A strong association was found between radiation absorbed dose and nonhyperthyroid and hypothyroid outcomes (odds ratio [OR] = 1.11 [95% confidence interval {CI} 1.08-1.14] and OR = 1.09 [CI 1.06-1.12] per 10 Gy increase). Higher rates of euthyroid outcome were found for radiation absorbed doses within the range 120-180 Gy when compared with outside this range (n = 1172, OR = 2.50 [CI 1.17-5.35], p = 0.018). A maximum euthyroid response of 38% was identified at a radiation absorbed dose of 128 Gy. Conclusions: The presented radiation absorbed dose-response relationships can facilitate personalized treatment planning for radioiodine treatment of patients with Graves' disease. Further studies are required to determine how patient-specific covariates can inform personalized treatments.


Assuntos
Doença de Graves/radioterapia , Radioisótopos do Iodo/farmacocinética , Dosagem Radioterapêutica , Glândula Tireoide/efeitos da radiação , Humanos , Radioisótopos do Iodo/uso terapêutico
10.
Phys Med ; 89: 1-10, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34339928

RESUMO

PURPOSE: The aims of this study were to develop and apply a method to correct for the differences in partial volume effects of pre-therapy Technetium-99 m (99mTc)-MAA SPECT and post-therapy Yttrium-90 (90Y) bremsstrahlung SPECT imaging in selective internal radiation therapy, and to use this method to improve quantitative comparison of predicted and delivered 90Y absorbed doses. METHODS: The spatial resolution of 99mTc SPECT data was converted to that of 90Y SPECT data using a function calculated from 99mTc and 90Y point spread functions. This resolution conversion method (RCM) was first applied to 99mTc and 90Y SPECT phantom data to validate the method, and then to clinical data to assess the power of 99mTc SPECT imaging to predict the therapeutic absorbed dose. RESULTS: The maximum difference between absorbed doses to phantom spheres was 178%. This was reduced to 27% after the RCM was applied. The clinical data demonstrated differences within 38% for mean absorbed doses delivered to the normal liver, which were reduced to 20% after application of the RCM. Analysis of clinical data showed that therapeutic absorbed doses delivered to tumours greater than 100 cm3 were predicted to within 52%, although there were differences of up to 210% for smaller tumours, even after the RCM was applied. CONCLUSIONS: The RCM was successfully verified using phantom data. Analysis of the clinical data established that the 99mTc pre-therapy imaging was predictive of the 90Y absorbed dose to the normal liver to within 20%, but had poor predictability for tumours smaller than 100 cm3.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Microesferas , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/uso terapêutico
11.
J Radiol Prot ; 41(4)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34261047

RESUMO

Biokinetic models developed for healthy humans are not appropriate to describe biokinetics in thyroid cancer patients following thyroidectomy. The aim of this study was to adjust the population model for iodine proposed by the International Commission on Radiological Protection (ICRP) for the use in these patients. Rate constants of the ICRP publication 128 model for iodine were adjusted using the population modelling software package Monolix to describe activity retention in whole-body, thyroid, blood and protein-bound iodine observed in 23 patients. The new set of rate constants was compared to the four uptake scenarios proposed in ICRP publication 128. Flow from the inorganic iodide in blood compartment into the first thyroid compartment decreases to 0.15 d-1compared to a value of 7.27 d-1for the ICRP publication 128 model with a medium uptake. The transfer from first to second thyroid compartments and the outflow from the second thyroid compartment increases. An increased turnover rate of extrathyroidal organic iodine is observed. The rate constant from inorganic iodide in blood to kidney was also adjusted. Overall a good agreement was found between the adjusted model and the activity retention in thyroid cancer patients. The adjustment of population pharmacokinetic models to describe the biokinetic properties of specific patient populations for therapeutic radiopharmaceuticals is essential to capture the changes in biokinetics. The proposed set of rate constants for the established ICRP publication 128 model can be used to more accurately assess radiation protection requirements for the treatment of thyroid cancer patients using radioiodine.


Assuntos
Iodo , Proteção Radiológica , Neoplasias da Glândula Tireoide , Humanos , Iodetos , Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia
12.
EJNMMI Phys ; 7(1): 61, 2020 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-33030702

RESUMO

BACKGROUND: Differentiated thyroid cancer has been treated with radioiodine for almost 80 years, although controversial questions regarding radiation-related risks and the optimisation of treatment regimens remain unresolved. Multi-centre clinical studies are required to ensure recruitment of sufficient patients to achieve the statistical significance required to address these issues. Optimisation and standardisation of data acquisition and processing are necessary to ensure quantitative imaging and patient-specific dosimetry. MATERIAL AND METHODS: A European network of centres able to perform standardised quantitative imaging of radioiodine therapy of thyroid cancer patients was set-up within the EU consortium MEDIRAD. This network will support a concurrent series of clinical studies to determine accurately absorbed doses for thyroid cancer patients treated with radioiodine. Five SPECT(/CT) systems at four European centres were characterised with respect to their system volume sensitivity, recovery coefficients and dead time. RESULTS: System volume sensitivities of the Siemens Intevo systems (crystal thickness 3/8″) ranged from 62.1 to 73.5 cps/MBq. For a GE Discovery 670 (crystal thickness 5/8″) a system volume sensitivity of 92.2 cps/MBq was measured. Recovery coefficients measured on three Siemens Intevo systems show good agreement. For volumes larger than 10 ml, the maximum observed difference between recovery coefficients was found to be ± 0.02. Furthermore, dead-time coefficients measured on two Siemens Intevo systems agreed well with previously published dead-time values. CONCLUSIONS: Results presented here provide additional support for the proposal to use global calibration parameters for cameras of the same make and model. This could potentially facilitate the extension of the imaging network for further dosimetry-based studies.

13.
EJNMMI Phys ; 7(1): 63, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33044651

RESUMO

BACKGROUND: Internal dosimetry evaluation consists of a multi-step process ranging from imaging acquisition to absorbed dose calculations. Assessment of uncertainty is complicated and, for that reason, it is commonly ignored in clinical routine. However, it is essential for adequate interpretation of the results. Recently, the EANM published a practical guidance on uncertainty analysis for molecular radiotherapy based on the application of the law of propagation of uncertainty. In this study, we investigated the overall uncertainty on a sample of a patient following the EANM guidelines. The aim of this study was to provide an indication of the typical uncertainties that may be expected from performing dosimetry, to determine parameters that have the greatest effect on the accuracy of calculations and to consider the potential improvements that could be made if these effects were reduced. RESULTS: Absorbed doses and the relative uncertainties were calculated for a sample of 49 patients and a total of 154 tumours. A wide range of relative absorbed dose uncertainty values was observed (14-102%). Uncertainties associated with each quantity along the absorbed dose calculation chain (i.e. volume, recovery coefficient, calibration factor, activity, time-activity curve fitting, time-integrated activity and absorbed dose) were estimated. An equation was derived to describe the relationship between the uncertainty in the absorbed dose and the volume. The largest source of error was the VOI delineation. By postulating different values of FWHM, the impact of the imaging system spatial resolution on the uncertainties was investigated. DISCUSSION: To the best of our knowledge, this is the first analysis of uncertainty in molecular radiotherapy based on a cohort of clinical cases. Wide inter-lesion variability of absorbed dose uncertainty was observed. Hence, a proper assessment of the uncertainties associated with the calculations should be considered as a basic scientific standard. A model for a quick estimate of uncertainty without implementing the entire error propagation schema, which may be useful in clinical practice, was presented. Ameliorating spatial resolution may be in future the key factor for accurate absorbed dose assessment.

14.
Phys Med Biol ; 65(17): 175019, 2020 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-32640429

RESUMO

Quality control tests of molecular imaging systems are hampered by the complexity of phantom preparation. It is proposed that radioisotopes can be directly incorporated into photo-polymer resins. Use of the radio-polymer in a 3D printer allows phantoms with more complex and reliable activity distributions to be produced whilst simplifying source preparation. Initial tests have been performed to determine the practicality of integrating Tc-99m into a photo-polymer and example phantoms produced to test suitability for quality control. Samples of build and support resins were extracted from the print cartridges of an Objet30Pro Polyjet 3D printer. The response of the resin to external factors including ionising radiation, light and dilution with Tc-99m pertechnetate were explored. After success of the initial tests the radio-polymer was used in the production of different phantoms. Radionuclide dose calibrator and gamma camera acquisitions of the phantoms were used to test accuracy of activity concentration, print consistency, uniformity and heterogeneous reproducibility. Tomographic phantoms were also produced including a uniform hot sphere, a complex configuration of spheres and interlacing torus's and a hot rod phantom. The coefficient of variation between repeat prints of a 12 g disk phantom was 0.08%. Measured activity within the disks agreed to within 98 ± 2% of the expected activity based on initial resin concentration. Gamma camera integral uniformity measured across a 3D printed flood field phantom was 5.2% compared to 6.0% measured with a commercial Co-57 flood source. Heterogeneous distributions of activity were successfully reproduced for both 2D and 3D imaging phantoms. Count concentration across regions of heterogeneity agreed with the planned activity assigned to those regions on the phantom design. 3D printing of radioactive phantoms has been successfully demonstrated and is a promising application for quality control of Positron Emission Tomography and Single Photon Emission Computed Tomography systems.


Assuntos
Imagem Molecular/instrumentação , Imagens de Fantasmas , Impressão Tridimensional , Calibragem , Humanos , Imageamento Tridimensional , Reprodutibilidade dos Testes , Tecnécio
15.
Cancer Biother Radiopharm ; 35(7): 530-539, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32429699

RESUMO

Introduction: Thorium-227 is an alpha-emitting radioisotope with potential therapeutic applications in targeted alpha therapy. Thorium-227 decays to Radium-223, which may have an independent biodistribution to that of the parent Thorium-227 radiopharmaceutical. Quantitative in vivo imaging with sodium iodide (NaI) detectors is challenging due to cross-talk between neighboring γ-photopeaks as well as scattered γ-photons. The aim of this work was to validate the use of a spectral analysis technique to estimate the activity of each isotope within a region of interest applied to a pair of conjugate view planar acquisitions, acquired at multiple energy windows. Methods: Energy spectra per unit activity arising from unscattered Thorium-227 photons and Radium-223 photons as well as from scattered photons were modeled. These spectra were scaled until the combination of these component spectra resulted in the closest match to the measured data in four energy windows. Results: Measured estimates of activity followed the known decay curves in phantoms representative of a human torso. The mean errors in estimating Thorium-227 and Radium-223 were 5.1% (range -8.0% to 40.0%) and 3.4% (range -50.0% to 48.7%), respectively. The differences between the integrals of the theoretical and estimated time activity curve were <10% for both Thorium-227 and Radium-223. Conclusion: γ-camera quantification of Thorium-227 and Radium-223 can be achieved by using multiple energy window acquisitions.


Assuntos
Modelos Teóricos , Compostos Radiofarmacêuticos/farmacocinética , Rádio (Elemento)/farmacocinética , Tório/farmacocinética , Câmaras gama , Humanos , Modelos Anatômicos , Imagens de Fantasmas , Radiometria/métodos , Espectrometria gama/instrumentação , Espectrometria gama/métodos , Distribuição Tecidual , Tronco/diagnóstico por imagem
16.
Q J Nucl Med Mol Imaging ; 63(3): 271-277, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31315346

RESUMO

The field of molecular radiotherapy is expanding rapidly, with the advent of many new radiotherapeutics for the treatment of common as well as for rare cancers. Treatment outcome is dependent on the absorbed doses delivered to target volumes and to healthy organs-at-risk, which are shown to vary widely from fixed administrations of activity. There have been significant developments in quantitative imaging and internal dosimetry in recent years, although clinical implementation of these methods has been slow in comparison with external beam radiotherapy, partly due to there being relatively few patients treated at single centers. Multicenter clinical trials are therefore essential to acquire the data required to ensure best practice and to develop the personalized treatment planning that this area is well suited to, due to the unrivalled opportunity to image the therapeutic drug in vivo. Initial preparation for such trials requires a significant effort in terms of resources and trial design. Imaging systems in participating centers must be characterized and set up for quantitative imaging to allow for collation of data. Data transfer for centralized processing is usually necessary but is hindered in some cases by data protection regulations and local logistics. Recent multicenter clinical trials involving radioiodine therapy have begun to establish the procedures necessary for quantitative SPECT imaging in a multicenter setting using standard and anthropomorphic phantoms. The establishment of national and international multicenter imaging and dosimetry networks will provide frameworks to develop and harmonize best practice with existing therapeutic procedures and to ensure rapid and optimized clinical implementation of new radiotherapeutics across all centers of excellence that offer molecular radiotherapy. This will promote networks and collaborations that can provide a sound basis for further developments and will ensure that nuclear medicine maintains a key role in future developments.


Assuntos
Ensaios Clínicos como Assunto/métodos , Radioisótopos do Iodo/uso terapêutico , Estudos Multicêntricos como Assunto/métodos , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/radioterapia , Humanos , Radiometria
17.
Br J Radiol ; 92(1101): 20190184, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31287737

RESUMO

OBJECTIVES: In non-small cell lung cancer (NSCLC) patients, to establish whether the fractional volumes of irradiated anatomic or perfused lung differed between those with and without deteriorating lung function or radiation associated lung injury (RALI). METHODS: 48 patients undergoing radical radiotherapy for NSCLC had a radiotherapy-planning CT scan and single photon emission CT lung perfusion imaging (99mTc-labelled macroaggregate albumin). CT defined the anatomic and the single photon emission CT scan (co-registered with CT) identified the perfused (threshold 20 % of maximum) lung volumes. Fractional volumes of anatomic and perfused lung receiving more than 5, 10, 13, 20, 30, 40, 50 Gy were compared between patients with deteriorating (>median decline) vs stable (30, 40, 50 Gy). Fractional volumes of anatomic and perfused lung receiving > 10 Gy best predicted decline in FEV1 (Area under receiver operating characteristic curve (Az = 0.77 and 0.76 respectively); sensitivity/specificity 75%/81 and 80%/71%) for a 32.7% anatomic and 33.5% perfused volume cut-off. Irradiating an anatomic fractional volume of 4.7% to > 50 Gy had a sensitivity/specificity of 83%/89 % for indicating RALI (Az = 0.83). CONCLUSION: A 10-20 Gy radiation dose to anatomic or perfused lung results in decline in FEV1. A fractional anatomic volume of >5% receiving >50 Gy influences development of RALI. ADVANCES IN KNOWLEDGE: Extent of low-dose radiation to normal lung influences functional respiratory decline.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Lesões por Radiação/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Dosagem Radioterapêutica , Tomografia Computadorizada de Emissão de Fóton Único/métodos
18.
Int J Radiat Oncol Biol Phys ; 105(4): 884-892, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31349058

RESUMO

PURPOSE: 223Ra-Dichloride is used for treatment of patients with metastatic bone disease from castration-resistant prostate cancer. The uptake and mechanism of action of 223Ra-Dichloride is not well understood. The aim of this work was to develop a compartmental model for 223Ra-Dichloride in patients to improve understanding of the underlying mechanisms. METHODS AND MATERIALS: A compartmental model was developed based on activity retention data from 6 patients (2 treatments of 110 kBq/kg 223Ra-Dichloride) for plasma, bone surfaces, small intestines, large intestines, and excretion data. Rate constants were extracted. Rate constant variability between patients and treatments was assessed. A population model was proposed and compared with the established International Commission on Radiological Protection-67 compartmental model. RESULTS: A single bone compartment cannot accurately describe activity retention in the skeleton. The addition of a second bone compartment improved the fit to skeleton retention data, and the Akaike information criterion decreased. Mean rate constants of 4.0 (range, 1.9-10.9) and 0.15 (0.07-0.39) h-1 were obtained for transport from plasma to first bone compartment and vice versa. Rate constants from first to second bone compartment and back of 0.03 (0.02-0.06) and 0.008 (0.003-0.011) h-1 were calculated. Rate constants for individual patients showed no significant difference between patients and treatments. CONCLUSIONS: The developed compartmental model suggests that 223Ra-Dichloride initially locates at the bone surface and is then incorporated into the bone matrix relatively quickly. This observation could have implications for dosimetry and understanding of the effects of alpha radiation on normal bone tissue. Results suggest that a population model based on patient measurements is feasible.


Assuntos
Antineoplásicos/farmacocinética , Neoplasias Ósseas/metabolismo , Neoplasias Ósseas/secundário , Neoplasias de Próstata Resistentes à Castração/patologia , Rádio (Elemento)/farmacocinética , Partículas alfa , Antineoplásicos/administração & dosagem , Antineoplásicos/sangue , Neoplasias Ósseas/sangue , Neoplasias Ósseas/radioterapia , Osso e Ossos/metabolismo , Humanos , Intestino Grosso/metabolismo , Intestino Delgado/metabolismo , Masculino , Modelos Biológicos , Radioisótopos/administração & dosagem , Radioisótopos/sangue , Radioisótopos/farmacocinética , Rádio (Elemento)/administração & dosagem , Rádio (Elemento)/sangue
19.
EJNMMI Phys ; 6(1): 1, 2019 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-30617816

RESUMO

BACKGROUND: The aim of this work was to characterise the attenuation properties of 3D-printed tungsten and to assess the feasibility for its use in gamma camera collimator manufacture. METHOD: 3D-printed tungsten disks were produced using selective laser melting (SLM). Measurements of attenuation were made through increasing numbers of disks for a Tc-99m (140 keV) and I-131 (364 keV) source. The technique was validated by repeating the measurements with lead samples. Resolution measurements were also made with a SLM tungsten collimator and compared to Monte Carlo simulations of the experimental setup. Different collimator parameters were simulated and compared against the physical measurements to investigate the effect on image quality. RESULTS: The measured disk thicknesses were on average 20% above the specified disk thicknesses. The measured attenuation for the tungsten samples were lower than the theoretical value determined from the National Institute of Standards and Technology (NIST) cross-sectional database (Berger and Hubbell, XCOM: photon cross-sections on a personal computer, 1987). The laser scan strategy had a significant influence on material attenuation (up to 40% difference). Results of these attenuation measurements indicate that the density of the SLM material is lower than the raw tungsten density. However, an improved performance compared to a lead collimator was observed. The SLM tungsten collimator was adequately simulated as 80% density and 110% septal thickness. Scatter and septal penetration were 17% less than a similar lead collimator and 33% greater than tungsten at 100% density. CONCLUSIONS: SLM manufacture of tungsten collimators is feasible. Attenuation properties of SLM tungsten are superior to the lead alternative and the opportunity for bespoke collimator design is appealing.

20.
Eur J Nucl Med Mol Imaging ; 45(13): 2456-2474, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30218316

RESUMO

A framework is proposed for modelling the uncertainty in the measurement processes constituting the dosimetry chain that are involved in internal absorbed dose calculations. The starting point is the basic model for absorbed dose in a site of interest as the product of the cumulated activity and a dose factor. In turn, the cumulated activity is given by the area under a time-activity curve derived from a time sequence of activity values. Each activity value is obtained in terms of a count rate, a calibration factor and a recovery coefficient (a correction for partial volume effects). The method to determine the recovery coefficient and the dose factor, both of which are dependent on the size of the volume of interest (VOI), are described. Consideration is given to propagating estimates of the quantities concerned and their associated uncertainties through the dosimetry chain to obtain an estimate of mean absorbed dose in the VOI and its associated uncertainty. This approach is demonstrated in a clinical example.


Assuntos
Neoplasias/radioterapia , Guias de Prática Clínica como Assunto , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Incerteza , Radioisótopos de Ítrio/administração & dosagem , Radioisótopos de Ítrio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA