Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Mil Med ; 189(Supplement_3): 510-516, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160836

RESUMO

INTRODUCTION: The purpose of this paper is to examine a scalable secure firearm storage intervention in the U.S. National Guard (NG) in preventing firearm injury and suicide. A study among firearm-owning members of the Mississippi NG testing Project Safe Guard (PSG), a 10 to 15 min lethal means counseling intervention, found that PSG increased self-reported secure firearm storage practices. Here, we sought to examine a "real world" rollout of a modified PSG program in the NG in which NG members were trained to understand the importance of lethal means safety and to deliver PSG to Guardsmen peers within their units. MATERIALS AND METHODS: The PSG team collaborated with the NG to identify 4 states for the rollout; for each state, the NG was responsible for identifying key personnel ("facilitators") who would receive the training. Team members provided in-person training at 5 locations across 4 states (AZ, GA, IA, and NV) from January to April 2023. Attendees were provided with combination trigger locks or cable locks and evaluation instructions. Questionnaires were administered to training attendees via REDCap at pre-training and post-training. We conducted descriptive and comparison statistics of questionnaire data. RESULTS: A total of 186 facilitators were trained at 5 in-person training locations across 4 states (AZ, GA, IA, and NV) from January to April 2023; data collection concluded in August 2023. There were 137 pre-training responses (74% pre-survey response rate) and 88 post-training responses (64% response rate from those who took the pre-training survey). Findings demonstrate increases in self-reported knowledge, attitudes, and beliefs regarding firearm injury and suicide and a reported desire to store personal firearms more securely. CONCLUSION: The adapted version of PSG shows promise as a relevant and acceptable intervention among Guardsmen to enhance knowledge and attitudes regarding firearm suicide, increase secure firearm storage practices, and normalize conversations about firearm suicide prevention among peers. This intervention seeks to frame firearm suicide prevention within a culture of safety, complementary to the existing prevention methods and training within the NG.


Assuntos
Armas de Fogo , Prevenção do Suicídio , Humanos , Armas de Fogo/estatística & dados numéricos , Masculino , Adulto , Feminino , Ferimentos por Arma de Fogo/prevenção & controle , Militares/estatística & dados numéricos , Militares/psicologia , Estados Unidos/epidemiologia , Mississippi , Inquéritos e Questionários , Suicídio/estatística & dados numéricos , Suicídio/psicologia
2.
Front Pediatr ; 12: 1354971, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756970

RESUMO

High-risk infants are discharged home from hospital with increased care needs and the potential for the emergence of developmental disabilities, contributing to high levels of parental stress and anxiety. To enable optimal outcomes for high-risk infants and their families, developmental follow-up programs need to continue following hospital discharge. However, current follow-up care for high-risk infants is variable in terms of type, access and equity, and there seems to be a gap in existing services such as supporting the transition home, parental support, and inclusion of all at-risk infants regardless of causality. Routine follow-up that identifies developmental delays or neuromotor concerns can facilitate timely referral and access to targeted intervention during critical periods of development. The Kids+ Parent Infant Program (PIP) is a unique model of developmental follow-up that shares some characteristics with established programs, but also includes additional key elements for a seamless, wrap-around service for all high-risk infants and their families living in a regional area of Australia. This community-based program provides integrated assessment and intervention of infants, alongside parent support and education, embracing a holistic model that accounts for the complexity and interrelatedness of infant, parent, medical and developmental factors. By prioritising the well-being of high-risk infants and their families, the Kids+ PIP paves the way for improved developmental outcomes and provides an innovative model for developmental follow-up, with the potential for reproduction in other healthcare settings.

3.
Radiography (Lond) ; 29(4): 786-791, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37267841

RESUMO

INTRODUCTION: This study aimed to provide clinically-relevant insights into establishing CT DRLs based on indication-based protocols in Ireland, focusing on CT head examinations performed at a neurology centre of excellence hospital. METHODS: Dose data were collected retrospectively. Typical values for six CT head indication-based protocols were established using a sample size of 50 patients for each protocol. Typical values for each protocol were set as the median of the distribution curve. Dose distributions for each protocol were calculated and compared using non-parametric median test (k-samples) to ascertain significant dose differences between the typical values. RESULTS: Most typical values pairings showed significant differences (p < 0.001) except between stroke/non-vascular brain, stroke/acute brain, and acute brain/non-vascular brain pairings. This was expected due to similar scan parameters. The typical value for stroke (3-phases angiogram) was 52% lower than the typical value for stroke. Dose levels of the male populations recorded were higher than female populations for all protocols. Statistical comparison showed significant differences for dose quantities and/or scan length between both genders in five protocols. CONCLUSION: Proposed values for DLP were up to 63% and 69% lower than the EU and Irish national DRLs respectively. Establishment of CT stroke DRLs should be based on the scan performed instead of number of scan acquisitions. Lastly, gender-based CT DRLs for specific protocols within the head region require further investigation. IMPLICATIONS FOR PRACTICE: With increasing CT examinations worldwide, radiation dose optimisation is key. The value of indication based DRLs is to enhance the required patient protection so image quality can be maintained, however with relevant DRLs for varying protocols. Establishment of CT typical values and site specific DRLs for procedures beyond the national DRLs can drive dose optimisation locally.


Assuntos
Níveis de Referência de Diagnóstico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Estudos Retrospectivos , Doses de Radiação , Valores de Referência , Tomografia Computadorizada por Raios X/métodos , Acidente Vascular Cerebral/diagnóstico por imagem
4.
Radiography (Lond) ; 29(1): 131-138, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36368249

RESUMO

INTRODUCTION: Accurate cardiac left ventricle (LV) delineation is essential to CT-derived left ventricular ejection fraction (LVEF). To evaluate dose-reduction potential, an anatomically accurate heart phantom, with realistic X-ray attenuation is required. We demonstrated and tested a custom-made phantom using 3D-printing, and examined the influence of image noise on automatically measured LV volumes METHODS: A single coronary CT angiography (CCTA) dataset was segmented and converted to Standard Tessellation Language (STL) mesh, using open-source software. A 3D-printed model, with hollow left heart chambers, was printed and cavities filled with gelatinized contrast media. This was CT-scanned in an anthropomorphic chest phantom, at different exposure conditions. LV and "myocardium" noise and attenuation was measured. LV volume was automatically measured using two different methods. We calculated Spearmans' correlation of LV volume with noise and contrast-noise ratio respectively om 486 scans of the phantom. Source images were compared to one phantom series with similar parameters. This was done using Dice coefficient on LV short-axis segmentations. RESULTS: Phantom "Myocardium" and LV attenuation was comparable to measurements on source images. Automatic volume measurement succeeded, with mean volume deviation to patient images less than 2 ml. There was a moderate correlation of volume with CNR, and strong correlation of volume with image noise. With papillary muscles included in LV volume, the correlation was positive, but negative when excluded. Variation of volumes was lowest at 90-100 kVp for both methods in the 486 repeat scans. The Dice coefficient was 0.87, indicating high overlap between the single phantom series and source scan. Cost of 3D-printer and materials was 400 and 30 Euro respectively. CONCLUSION: Both anatomically and radiologically the phantom mimicked the source scans closely. LV volumetry was reliably performed with automatic algorithms. IMPLICATIONS FOR PRACTICE: Patient-specific cardiac phantoms may be produced at minimal cost and can potentially be used for other anatomies and pathologies. This enables radiographic phantom studies without need for dedicated 3D-labs or expensive commercial phantoms.


Assuntos
Ventrículos do Coração , Função Ventricular Esquerda , Humanos , Ventrículos do Coração/diagnóstico por imagem , Projetos Piloto , Volume Sistólico , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Impressão Tridimensional
5.
J Public Health (Oxf) ; 45(1): 102-108, 2023 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-34850220

RESUMO

BACKGROUND: Lesbian, gay and bisexual (LGB) young people's increased risk of self-harm, suicidal attempts and suicide compared with heterosexual youth is well established. The current study sought to examine whether these findings also apply to the trans (T) population and which factors act as additional risk or protective factors. METHODS: In a national cross-sectional survey, 3713 LGBT adolescents, aged 11-19 years, reported on their own history of self-harm, suicidal ideation and suicide attempts, as well as their experiences of school and homophobic, biphobic and transphobic bullying. Logistic regressions tested the association between risk and protective factors on self-harm, suicidal ideation and suicide attempts. RESULTS: A high proportion of the sample reported self-harm (65.3%), suicidal ideation (73.8%) and suicide attempts (25.7%). Demographic risk factors included identifying as female, non-binary or trans and being from a low-income background. Bullying and online bullying were associated with an increased risk for each outcome, and positive school experience was associated with a reduced risk for each outcome. CONCLUSIONS: Consistent with minority stress theory, the study found high rates of mental health problems within LGBT youth. Interventions focused on improving young people's experiences in schools appear useful targets to help improve mental health outcomes.


Assuntos
Bullying , Comportamento Autodestrutivo , Minorias Sexuais e de Gênero , Humanos , Adolescente , Feminino , Status Econômico , Estudos Transversais , Comportamento Autodestrutivo/epidemiologia , Comportamento Autodestrutivo/psicologia , Ideação Suicida , Instituições Acadêmicas
6.
Radiat Prot Dosimetry ; 198(8): 441-447, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35640248

RESUMO

This study investigated the effects of cone-beam computed tomography (CBCT) guidance in trans-arterial chemoembolisation (TACE) procedures on the number of digital subtraction angiography (DSA) runs acquired and total patient radiation exposure in patients with hepatocellular carcinoma (HCC). A retrospective, analytical cross-sectional, single institution, study was conducted. Dose data were compared across the control (DSA guidance alone) and study (DSA and CBCT guidance) groups. A total of 122 procedures were included within the study. There was a significant reduction in the number of DSA runs (3 vs 5, p < 0.001) and DSA air kerma-area product (PKA) (3077.3 vs 4276.6 µGym2, p = 0.042) for the study group when compared to the control group. Total procedural PKA and total procedural reference air kerma (Ka,r) were shown to be 50 and 73% higher, respectively, for the study group when compared to the control group. CBCT imaging guidance does reduce the number of DSA runs and DSA PKA required to complete the TACE procedure for patients diagnosed with HCC; however, a substantial increase in total procedural PKA is to be expected and it is thus important that this increased dose is carefully considered and justified.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Exposição à Radiação , Angiografia Digital/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos Transversais , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Estudos Retrospectivos
7.
EMBO Mol Med ; 14(4): e14297, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35298086

RESUMO

T cells are the current choice for many cell therapy applications. They are relatively easy to access, expand in culture, and genetically modify. Rapamycin-conditioning ex vivo reprograms T cells, increasing their memory properties and capacity for survival, while reducing inflammatory potential and the amount of preparative conditioning required for engraftment. Rapamycin-conditioned T cells have been tested in patients and deemed to be safe to administer in numerous settings, with reduced occurrence of infusion-related adverse events. We demonstrate that ex vivo lentivirus-modified, rapamycin-conditioned CD4+ T cells can also act as next-generation cellular delivery vehicles-that is, "micropharmacies"-to disseminate corrective enzymes for multiple lysosomal storage disorders. We evaluated the therapeutic potential of this treatment platform for Fabry, Gaucher, Farber, and Pompe diseases in vitro and in vivo. For example, such micropharmacies expressing α-galactosidase A for treatment of Fabry disease were transplanted in mice where they provided functional enzyme in key affected tissues such as kidney and heart, facilitating clearance of pathogenic substrate after a single administration.


Assuntos
Lentivirus , Doenças por Armazenamento dos Lisossomos , Sirolimo , Linfócitos T , Animais , Modelos Animais de Doenças , Lentivirus/genética , Doenças por Armazenamento dos Lisossomos/terapia , Lisossomos , Camundongos , Sirolimo/uso terapêutico , Linfócitos T/efeitos dos fármacos , alfa-Galactosidase/uso terapêutico
8.
Radiography (Lond) ; 28(2): 353-359, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34953726

RESUMO

Patient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control (AEC) systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology. A number of professional bodies have already issued guidance in this regard. This paper represents the current consensus view of the main bodies involved in radiation safety and imaging in Europe: European Federation of Organisations for Medical Physics, European Federation of Radiographer Societies, European Society of Radiology, European Society of Paediatric Radiology, EuroSafe Imaging, European Radiation Dosimetry Group (EURADOS), and European Academy of DentoMaxilloFacial Radiology (EADMFR). It is based on the expert recommendations of the Gonad and Patient Shielding (GAPS) Group formed with the purpose of developing consensus in this area. The recommendations are intended to be clear and easy to use. They are intended as guidance, and they are developed using a multidisciplinary team approach. It is recognised that regulations, custom and practice vary widely on the use of patient shielding in Europe and it is hoped that these recommendations will inform a change management program that will benefit patients and staff.


Assuntos
Radiologia , Criança , Consenso , Humanos , Doses de Radiação , Radiografia , Radiologia/métodos , Tomografia Computadorizada por Raios X/métodos
9.
Radiography (Lond) ; 28(2): 426-432, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34556417

RESUMO

INTRODUCTION: To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols. METHODS: Characteristics of the left and right coronary arteries (mean Hounsfield Unit (HU) values and diameters) were collected from consecutive CCTA examinations (n = 43). Four different materials (two mixtures of glycerine, gelatine and water, pig hearts, Ecoflex™ silicone) were scanned inside a Lungman phantom using the CCTA protocol to find the closest model to in vivo data. A 3D printed model of the coronary artery tree was created using CCTA data by exporting a CT volume rendering into Autodesk Meshmixer™ software. The model was placed in an acid bath for 5 h, then covered in Ecoflex™, which was removed after drying. Both the Ecoflex™ and pig heart were later filled with a mixture of contrast (Visipaque 320 mg I/ml), NaCl and gelatin and scanned with different levels of tube current and iterative reconstruction (ASiR-V). Objective (HU, noise and size (vessel diameter) and subjective analysis were performed on all scans. RESULTS: The gelatine mixtures had HU values of 130 and 129, Ecoflex™ 65 and the pig heart 56. At the different mA/ASiR-V levels the contrast filled Ecoflex™ had a mean HU 318 ± 4, noise 47±7HU and diameter of 4.4 mm. The pig heart had a mean HU of 209 ± 5, noise 38±4HU and a diameter of 4.4 mm. With increasing iterative reconstruction level the visualisation of the pig heart arteries decreased so no measurements could be performed. CONCLUSION: The use of a 3D printed model of the arteries and casting with the Ecoflex™ silicone is the most suitable solution for a custom-designed phantom. IMPLICATIONS FOR PRACTICE: Custom designed phantoms using 3D printing technology enable cost effective optimisation of CT protocols.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Animais , Vasos Coronários/diagnóstico por imagem , Humanos , Impressão Tridimensional , Doses de Radiação , Silicones , Suínos , Tomografia Computadorizada por Raios X/métodos
10.
Radiography (Lond) ; 28(1): 48-54, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34404576

RESUMO

INTRODUCTION: Education and training of radiographers is known to be diverse between countries and regions. Under an IAEA project, this work collected data on radiographer education for the Europe and Central Asia region with a particular focus on radiation protection gaps and potential actions. METHODS: Following piloting, an electronic questionnaire was distributed to all national counterparts for the IAEA Technial Coopearation (TC) Europe region (n = 33 countries) and nominated national representatives. Contacts were additionally invited to a virtual workshop to discuss and rank common problems in education and training of radiographers and to propose potential solutions. RESULTS: Responses were received from 31 countries, including 14 from the European Union. Just over half of countries reported radiographer education being in higher education with 71% having program durations more than 3 years (range: 1 month-4 years). Programs included a spectrum of both clinical training and radiation protection hours with ten-fold variations noted across the region. Inclusion of core radiation protection topics within curricula varied similarly, as did radiographers' clinical involvement in both justification and optimisation between countries. Workshop participants identified five common training problems, namely education availability, lack of standardisation, radiation protection course quality, teamwork problems and lack of equipment. CONCLUSION: Radiographer education in the IAEA Europe region is heterogeneous with substantial differences in duration and quality of training programs between countries, which likely impact on quality of patient care delivered. Common problems have been identified and potential solutions proposed to focus quality improvement initiatives. IMPLICATIONS FOR PRACTICE: Radiographer education and training is diverse throughout the IAEA TC Europe region, with likely impacts on radiation protection practices applied. Clinical involvement of radiographers in justification and optimisation differs, potentially limiting adherence to radiation protection principles.


Assuntos
Pessoal Técnico de Saúde , Proteção Radiológica , Ásia , Europa (Continente) , Humanos , Inquéritos e Questionários
11.
Transl Psychiatry ; 11(1): 592, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34785639

RESUMO

Gamma oscillations (30-90 Hz) have been proposed as a signature of cortical visual information processing, particularly the balance between excitation and inhibition, and as a biomarker of neuropsychiatric diseases. Magnetoencephalography (MEG) provides highly reliable visual-induced gamma oscillation estimates, both at sensor and source level. Recent studies have reported a deficit of visual gamma activity in schizophrenia patients, in medication naive subjects, and high-risk clinical participants, but the genetic contribution to such a deficit has remained unresolved. Here, for the first time, we use a genetic risk score approach to assess the relationship between genetic risk for schizophrenia and visual gamma activity in a population-based sample drawn from a birth cohort. We compared visual gamma activity in a group (N = 104) with a high genetic risk profile score for schizophrenia (SCZ-PRS) to a group with low SCZ-PRS (N = 99). Source-reconstructed V1 activity was extracted using beamformer analysis applied to MEG recordings using individual MRI scans. No group differences were found in the induced gamma peak amplitude or peak frequency. However, a non-parametric statistical contrast of the response spectrum revealed more robust group differences in the amplitude of high-beta/gamma power across the frequency range, suggesting that overall spectral shape carries important biological information beyond the individual frequency peak. Our findings show that changes in gamma band activity correlate with liability to schizophrenia and suggest that the index changes to synaptic function and neuronal firing patterns that are of pathophysiological relevance rather than consequences of the disorder.


Assuntos
Esquizofrenia , Coorte de Nascimento , Ritmo Gama , Humanos , Magnetoencefalografia , Fatores de Risco , Esquizofrenia/genética
12.
Cytotherapy ; 23(9): 820-832, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34217618

RESUMO

BACKGROUND AIMS: T cells engineered with synthetic receptors have delivered powerful therapeutic results for patients with relapsed/refractory hematologic malignancies. The authors have recently described the T-cell antigen coupler (TAC) receptor, which co-opts the endogenous T-cell receptor (TCR) and activates engineered T cells in an HLA-independent manner. Here the authors describe the evolution of a next-generation TAC receptor with a focus on developing a TAC-engineered T cell for multiple myeloma. METHODS: To optimize the TAC scaffold, the authors employed a bona fide antigen-binding domain derived from the B-cell maturation antigen-specific monoclonal antibody C11D5.3, which has been used successfully in the clinic. The authors first tested humanized versions of the UCHT1 domain, which is used by the TAC to co-opt the TCR. The authors further discovered that the signal peptide affected surface expression of the TAC receptor. Higher density of the TAC receptor enhanced target binding in vitro, which translated into higher levels of Lck at the immunological synapse and stronger proliferation when only receptor-ligand interactions were present. RESULTS: The authors observed that the humanized UCHT1 improved surface expression and in vivo efficacy. Using TAC T cells derived from both healthy donors and multiple myeloma patients, the authors determined that despite the influence of receptor density on early activation events and effector function, receptor density did not impact late effector functions in vitro, nor did the receptor density affect in vivo efficacy. CONCLUSIONS: The modifications to the TAC scaffold described herein represent an important step in the evolution of this technology, which tolerates a range of expression levels without impacting therapeutic efficacy.


Assuntos
Antígeno de Maturação de Linfócitos B , Mieloma Múltiplo , Humanos , Imunoterapia Adotiva , Mieloma Múltiplo/terapia , Recidiva Local de Neoplasia , Receptores de Antígenos de Linfócitos T/genética , Linfócitos T
13.
Eur Radiol ; 31(10): 7984-7991, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33856515

RESUMO

OBJECTIVES: Justification of medical exposures from medical imaging is fundamental to radiation protection. Referral guidelines are intended to help physicians decide when an imaging study is justified. For two decades, referral guidelines have been a legally binding requirement for European Union member states. Recently, the European Society of Radiology (ESR) developed iGuide tool, which provides evidence-based referral guidance for imaging inclusive of children. The aim of this survey was to assess the availability, use and familiarity of referral guidelines for medical imaging in children and knowledge about the availability of ESR iGuide among ESR member radiologists. METHODS: Over a 2-month period (15 September-15 November 2019), 33,257 ESR member radiologists were invited to respond to an anonymised web-based questionnaire, which consisted of 12 multiple-choice questions. RESULTS: In total, 2067/33,257 responses (6.3%) were received from 52 countries. A total of 1068 out of 2067 (51.7%) respondents were aware that imaging referral guidelines are a legal requirement. One thousand five (48.6%) of all respondents did not know whether dedicated guidelines for imaging in children were available, and only 653 (31.2%) were aware of the mainstays of the available guidelines. Similarly, just 746 (36.1%) of all respondents were aware of ESR iGuide availability and features. CONCLUSIONS: The information gathered confirms that effective and widespread adoption of imaging referral guidelines is lacking, especially in children. Further work is required to improve uptake and awareness. KEY POINTS: • Justification of medical exposures is fundamental to radiation protection and evidence-based referral guidelines are crucial for practical implementation of this principle. • About half of survey respondents are aware that the availability of imaging referral guidelines is a legal requirement, despite this being mandated since 1997. • The information gathered from this survey confirms that, especially in children, an effective and widespread adoption of imaging referral guidelines is lacking.


Assuntos
Proteção Radiológica , Radiologistas , Criança , Diagnóstico por Imagem , Humanos , Encaminhamento e Consulta , Inquéritos e Questionários
14.
Radiography (Lond) ; 27(1): 1-7, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32402706

RESUMO

INTRODUCTION: Organ-based tube current modulation (OBTCM) is designed for anterior dose reduction in Computed Tomography (CT). The purpose was to assess dose reduction capability in chest CT using three organ dose modulation systems at different kVp settings. Furthermore, noise, diagnostic image quality and tumour detection was assessed. METHODS: A Lungman phantom was scanned with and without OBTCM at 80-135/140 kVp using three CT scanners; Canon Aquillion Prime, GE Revolution CT and Siemens Somatom Flash. Thermo-luminescent dosimeters were attached to the phantom surface and all scans were repeated five times. Image noise was measured in three ROIs at the level of the carina. Three observers visually scored the images using a fivestep scale. A Wilcoxon Signed-Rank test was used for statistical analysis of differences. RESULTS: Using the GE revolution CT scanner, dose reductions between 1.10 mSv (12%) and 1.56 mSv (24%) (p < 0.01) were found in the anterior segment and no differences posteriorly and laterally. Total dose reductions between 0.64 (8%) and 0.91 mSv (13%) were found across kVp levels (p < 0.00001). Maximum noise increase with OBTCM was 0.8 HU. With the Canon system, anterior dose reductions of 6-10% and total dose reduction of 0.74-0.76 mSv across kVp levels (p < 0.001) were found with a maximum noise increase of 1.1 HU. For the Siemens system, dose increased by 22-51% anteriorly; except at 100 kVp where no dose difference was found. Noise decreased by 1 to 1.5 HU. CONCLUSION: Organ based tube current modulation is capable of anterior and total dose reduction with minimal loss of image quality in vendors that do not increase posterior dose. IMPLICATIONS FOR PRACTICE: This research highlights the importance of being familiar with dose reduction technologies.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Doses de Radiação
15.
RSC Med Chem ; 11(5): 559-568, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33479657

RESUMO

Arginase is involved in a wide range of pathologies including cardiovascular diseases and infectious diseases whilst it is also a promising target to improve cancer immunotherapy. To date, only a limited number of inhibitors of arginase have been reported. Natural polyphenols, among them piceatannol, are moderate inhibitors of arginase. Herein, we report our efforts to investigate catechol binding by quantum chemistry and generate analogues of piceatannol. In this work, we synthesized a novel series of amino-polyphenols which were then evaluated as arginase inhibitors. Their structure-activity relationships were elucidated by deep quantum chemistry modelling. 4-((3,4-Dihydroxybenzyl)amino)benzene-1,2-diol 3t displays a mixed inhibition activity on bovine and human arginase I with IC50 (K i) values of 76 (82) µM and 89 µM, respectively.

17.
N Engl J Med ; 380(1): 45-56, 2019 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-30501490

RESUMO

BACKGROUND: Patients with diffuse large B-cell lymphoma that is refractory to primary and second-line therapies or that has relapsed after stem-cell transplantation have a poor prognosis. The chimeric antigen receptor (CAR) T-cell therapy tisagenlecleucel targets and eliminates CD19-expressing B cells and showed efficacy against B-cell lymphomas in a single-center, phase 2a study. METHODS: We conducted an international, phase 2, pivotal study of centrally manufactured tisagenlecleucel involving adult patients with relapsed or refractory diffuse large B-cell lymphoma who were ineligible for or had disease progression after autologous hematopoietic stem-cell transplantation. The primary end point was the best overall response rate (i.e., the percentage of patients who had a complete or partial response), as judged by an independent review committee. RESULTS: A total of 93 patients received an infusion and were included in the evaluation of efficacy. The median time from infusion to data cutoff was 14 months (range, 0.1 to 26). The best overall response rate was 52% (95% confidence interval, 41 to 62); 40% of the patients had complete responses, and 12% had partial responses. Response rates were consistent across prognostic subgroups. At 12 months after the initial response, the rate of relapse-free survival was estimated to be 65% (79% among patients with a complete response). The most common grade 3 or 4 adverse events of special interest included cytokine release syndrome (22%), neurologic events (12%), cytopenias lasting more than 28 days (32%), infections (20%), and febrile neutropenia (14%). Three patients died from disease progression within 30 days after infusion. No deaths were attributed to tisagenlecleucel, cytokine release syndrome, or cerebral edema. No differences between response groups in tumor expression of CD19 or immune checkpoint-related proteins were found. CONCLUSIONS: In this international study of CAR T-cell therapy in relapsed or refractory diffuse large B-cell lymphoma in adults, high rates of durable responses were produced with the use of tisagenlecleucel. (Funded by Novartis; JULIET ClinicalTrials.gov number, NCT02445248 .).


Assuntos
Imunoterapia Adotiva , Linfoma Difuso de Grandes Células B/terapia , Receptores de Antígenos de Linfócitos T/uso terapêutico , Receptores de Antígenos Quiméricos/uso terapêutico , Adulto , Idoso , Feminino , Humanos , Linfoma Difuso de Grandes Células B/mortalidade , Linfoma Difuso de Grandes Células B/patologia , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Intervalo Livre de Progressão , Recidiva , Análise de Sobrevida , Adulto Jovem
18.
QJM ; 111(6): 399-403, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29579300

RESUMO

BACKGROUND: Psychological features associated with execution are not fully understood. AIMS: To analyse demographics of individuals executed in Texas and investigate whether there has been any change in common themes and psychological factors evident in last statements before execution between 2002 and 2017. DESIGN: Analysis of last statements from Death Row, Texas. METHODS: We (a) studied themes and psychological factors in last statements in Texas between August 2011 and May 2017; and (b) combined our 2011-17 data with our previous data (2002-06 and 2006-11) to present an overall analysis of last statements from 2002 to 2017. RESULTS: Between April 2002 and May 2017 (279 executions; 240 last statements), the execution rate in Texas fell from 25 per year to 12; median time on death row increased from 108.5 months to 149.5; median age at execution increased from 38 years to 40.5; and the proportion of offences involving multiple victims rose from 28.4% to 47.1%. The most common themes in last statements were love (78%), spirituality (58%), regret (35%) and apology (35%). The most common psychological factors were identification-egression (51%), unbearable psychological pain (47%) and rejection-aggression (40%). Two themes (forgiveness, use of poetry/literature) and three psychological factors (inability to adjust, interpersonal relations, identification-egression) became less common. CONCLUSIONS: Between 2002 and 2017, executed prisoners in Texas became fewer and older, spent longer on death row and had committed more serious offences. Themes of love and spirituality were constants, but requests for forgiveness declined.


Assuntos
Pena de Morte , Perdão , Amor , Prisioneiros/psicologia , Espiritualidade , Adulto , Feminino , Humanos , Masculino , Texas , Adulto Jovem
19.
Radiat Prot Dosimetry ; 181(3): 261-268, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29462479

RESUMO

The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE Healthcare, Milwaukee, WI, USA) with various CT parameters, including Fast kVp switching. Dosimetry was performed using thermo-luminescent dosimeters, positioned both superficially and within the phantom. SSDE was calculated for all slices of the anthropomorphic phantom using both the localiser and axial images. In Fast kVp switching, SSDE underestimated the measured absorbed dose for the chest/abdomen region ~35% at the maximum, but were in closer agreement for the pelvic region about within 10%. In single energy techniques, SSDE could not be applied in the estimation of organ doses, but in Fast kVp switching dual energy techniques, SSDE could be applied for anatomical regions with larger thicknesses.


Assuntos
Abdome/efeitos da radiação , Pelve/efeitos da radiação , Imagens de Fantasmas , Monitoramento de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação , Radiografia Torácica
20.
Radiography (Lond) ; 24(1): 28-32, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29306371

RESUMO

INTRODUCTION: Computed Tomography (CT) use has increased in recent years with trends indicating increasing population doses as a result. Optimization of clinical radiation doses through technological developments has demonstrated potential to reduce patient dose from CT. This study aimed to quantify these dose reductions across a large clinical cohort. METHODS: Patient cohort was divided into three groups, assigned by CT optimisation technique. Group one underwent scanning with automated tube current modulation only. Group two underwent scanning with automated tube current modulation and iterative reconstruction and group three underwent scanning with automated tube current modulation, iterative reconstruction and automatic tube voltage modulation. Patient dose length product doses were retrospectively collected for the three groups. Clinical radiation doses between the groups were compared for four common CT examinations (Brain, pulmonary angiography, abdomen and thorax abdomen pelvis scans). RESULTS: Of 4011 patients, group one comprised of 1643 patients (40.96%), group two 1077 patients (26.85%) and group three 1291 patients (32.19%). No differences were found when comparing AP diameter between groups (p ≥ 0.05). Statistically significant dose reductions of 16-31% were achieved using iterative reconstruction alone (p = 0.001) and 24-42% with both iterative reconstruction and automatic tube voltage selection (p = 0.001). Objective noise improved when iterative reconstruction was used (p < 0.05). CONCLUSION: The application of optimization software confers significant dose savings during routine clinical CT examinations. Figures are based on a large clinical cohort, with equipment, staff and procedural protocols remaining consistent throughout. Dose reductions are likely to reflect the clinical dose reducing potential of the optimization software investigated.


Assuntos
Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Artefatos , Encéfalo/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Humanos , Pelve/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Tecnologia Radiológica , Tórax/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA