Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 190
Filtrar
1.
Rev Cardiovasc Med ; 25(4): 125, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-39076547

RESUMO

Wolff-Parkinson-White (WPW) syndrome is defined by specific electrocardiogram (ECG) changes resulting in ventricular pre-excitation (the so-called WPW pattern), related to the presence of an accessory pathway (AP), combined with recurrent tachyarrhythmias. WPW syndrome is characterized by different supraventricular tachyarrhythmias (SVT), including atrioventricular re-entry tachycardia (AVRT) and atrial fibrillation (AF) with rapid ventricular response, with AVRT being the most common arrhythmia associated with WPW, and AF occurring in up to 50% of patients with WPW. Several mechanisms might be responsible for AF development in the WPW syndrome, and a proper electrocardiographic interpretation is of pivotal importance since misdiagnosing pre-excited AF could lead to the administration of incorrect treatment, potentially inducing ventricular fibrillation (VF). Great awareness of pre-excited AF's common ECG characteristics as well as associated causes and its treatment is needed to increase diagnostic performance and improve patients' outcomes. In the present review, starting from a paradigmatic case, we discuss the characteristics of pre-excited AF in the emergency department and its management, focusing on the most common ECG abnormalities, pharmacological and invasive treatment of this rhythm disorder.

2.
Heart Rhythm ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39029882

RESUMO

BACKGROUND: Limited data are available on leadless pacemaker (LPM) outcomes according to different stages of chronic kidney disease (CKD). OBJECTIVE: To investigate differences regarding safety and efficacy in LPMs patients stratified per different stages of renal function. METHODS: Consecutive patients enrolled in the multicenter, international i-LEAPER registry were analyzed. Patients were divided into three groups according to CKD stage. The primary endpoint was the comparison of LPM-related major complication rate at implant and during follow-up. Differences in electrical performance were deemed secondary outcomes. RESULTS: Among 1748 patients enrolled, 33% were CKD stage G3a/G3b and 9.4% were CKD stage G4/G5. CKD patients presented cardiovascular comorbidities more frequently. During a median follow-up of 39 [interquartile range (IQR) 18-59] months, major complications rate did not differ between groups (normal kidney function, NKF=1.8% vs CKD stage-G3a/G3b 2.9% vs CKD stage-G4/G5 2.4%, p=0.418). All-cause mortality resulted higher in CKD stage-G4/G5 when compared with NKF group (19.5% vs 9.8%, aHR:1.9, 95%CI 1.25-2.89, p=0.003). LPM electrical performance was comparable between groups, except for CKD patients who showed a slightly higher pacing threshold during the 1-month follow-up (NKF group 0.50 [IQR 0.35-0.70]V vs G3a/G3b group 0.56 [IQR 0.38-0.81]V vs G4/G5 group, 0.51 [0.38-0.84]V @0.24 msec, p<.001). CONCLUSION: In a real-world setting, advanced CKD patients who underwent LPM implantation were underrepresented. Although all-cause mortality was higher in end-stage CKD, periprocedural complications and LPM performance were overall comparable between NKF and different stages of CKD, except for higher values of pacing threshold in CKD patients up to first-month follow-up.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38814252

RESUMO

BACKGROUND: Catheter ablation (CA) of atrial fibrillation is routinely used to obtain rhythm control. Evidence suggest that catheter ablation should be done during uninterrupted oral anticoagulation. METHODS: Italian Registry in the setting of atrial fibrillation ablation with rivaroxaban (IRIS) is an Italian multicenter, non-interventional, prospective study which enrolled 250 consecutive atrial fibrillation patients eligible for catheter ablation on rivaroxaban. The decision for rivaroxaban management was left to the physician: uninterrupted or shortly interrupted prior to Catheter ablation. Patients received a follow-up visit at 1 month and 12 months after the procedure. RESULTS: The primary outcome, represented by all-cause death and systemic embolism at 1 month and 12 months was characterized by one transient ischemic attack and one myocardial infarction in the first 30 days. Both events happened in patients with shortly interrupted strategy (P=0.147), and both in patients who underwent radiofrequency ablation (P=0.737). In the primary safety outcome represented by major bleeding we did not register any event in the 12-month follow-up. The secondary outcome constituted by minor bleeding registered 1 event, after the first 30 days since CA. CONCLUSIONS: IRIS is the biggest real-life data registry regarding CA ablation on rivaroxaban in Italian setting, proving the safety and efficacy of rivaroxaban.

4.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696701

RESUMO

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Pontuação de Propensão , Sistema de Registros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Arritmias Cardíacas/terapia , Medição de Risco , Europa (Continente) , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
5.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
6.
Heart Rhythm ; 21(7): 1072-1080, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38432424

RESUMO

BACKGROUND: Leadless pacemakers (LPs) capable of VDD pacing allow for atrioventricular synchrony through mechanical sensing of atrial contraction. However, mechanical sensing is less reliable and less predictable than electrical sensing. OBJECTIVE: The purpose of this study was to evaluate P-wave amplitude during sinus rhythm from preoperative 12-lead electrocardiograms (ECGs) as a predictor for atrial mechanical sensing in patients undergoing VDD LP implantation. METHODS: Consecutive patients undergoing VDD LP implantation were included in this 2-center prospective cohort study. ECG parameters were evaluated separately and in combination for association with the signal amplitude of atrial mechanical contraction (A4). RESULTS: Eighty patients (median age 82 years; female 55%; mean body mass index [BMI] 25.8 kg/m2) were included in the study and 61 patients in the A4 signal analysis (19 patients in VVI mode during follow-up). Absolute (aVL, aVF, V1, V2) and BMI-adjusted (I, II, aVL, aVF, aVR, V1, V2) P-wave amplitudes from baseline ECGs demonstrated a statistically significant positive correlation with A4 signal amplitude (all P <.05). A combined P-wave signal amplitude of at least 0.2 mV in V1 and aVL was predictive, with specificity of 83% (95% confidence interval 67%-100%) for A4 signal ≥1 m/s2. We found a significant correlation of A4 signal amplitude and overall atrioventricular synchrony (P = .013). CONCLUSION: P-wave amplitudes in ECG leads aVL and V1 can predict A4 signal amplitude in patients with VDD LP and therefore the probability of successful AV synchronous pacing.


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Átrios do Coração , Marca-Passo Artificial , Humanos , Feminino , Masculino , Idoso de 80 Anos ou mais , Estudos Prospectivos , Estimulação Cardíaca Artificial/métodos , Átrios do Coração/fisiopatologia , Idoso , Desenho de Equipamento , Seguimentos
7.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
8.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
9.
J Clin Med ; 12(20)2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37892671

RESUMO

BACKGROUND: The safety and efficacy of an uninterrupted direct anticoagulation (DOAC) strategy during catheter ablation (CA) for atrial fibrillation (AF) has not been fully investigated with different ablation techniques. METHODS: We evaluated consecutive AF patients undergoing catheter ablation with three different techniques. All patients were managed with an uninterrupted DOAC strategy. The primary endpoint was the rate of periprocedural thromboembolic and bleeding events. The secondary endpoints of the study were the rate of MACE and bleeding events at one-year follow-up. RESULTS: In total, 162 patients were enrolled. Overall, 53 were female and the median age was 60 [55.5-69.5] years. The median CHA2DS2-VASc and HAS-BLED scores were 2 [1-4] and 2 [1-2], respectively. In total, 16 patients had a past stroke or TIA while 11 had a predisposition or a history of bleeding. The CA procedure was performed with different techniques: RF 43%, cryoballoon 37%, or laser-balloon 20%. Overall, 35.8% were on rivaroxaban, 20.4% were on edoxaban, 6.8% were on apixaban, and 3.7% were on dabigatran. All other patients were all naïve to DOACs; the first anticoagulant dose was given before the ablation procedure. As for periprocedural complications, we found three groin hematomas not requiring interventions, one ischemic stroke, and one systemic air embolism (the last two likely due to several catheter changes through the transeptal sheath). Five patients reached the secondary endpoints: one patient for a myocardial infarction while four patients experienced minor bleeding during 1-year follow-up. CONCLUSIONS: Our results corroborate the safety and the efficacy of uninterrupted DOAC strategy in patients undergoing CA for AF, regardless of the ablation technique.

10.
Expert Rev Med Devices ; 20(11): 951-961, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37712650

RESUMO

BACKGROUND: The prognosis for heart failure (HF) patients remains poor, with a high mortality rate, and a marked reduction in quality of life (QOL) and functional status. This study aims to explore the ongoing needs of HF management and the epidemiology of patients followed by Italian HF clinics, with a specific focus on cardiac contractility modulation (CCM). RESEARCH DESIGN AND METHODS: Data from patients admitted to 14 HF outpatients clinics over 4 weeks were collected and compared to the results of a survey open to physicians involved in HF management operating in Italian centers. RESULTS: One hundred and five physicians took part in the survey. Despite 94% of patients receive a regular follow-up every 3-6 months, available therapies are considered insufficient in 30% of cases. Physicians reported a lack of treatment options for 23% of symptomatic patients with reduced ejection fraction (EF) and for 66% of those without reduced EF. Approximately 3% of HF population (two patients per month per HF clinic) meets the criteria for immediate CCM treatment, which is considered a useful option by 15% of survey respondents. CONCLUSIONS: Despite this relatively small percentage, considering total HF population, CCM could potentially benefit numerous HF patients, particularly the elderly, by reducing hospitalizations, improving functional capacity and QOL.

11.
J Cardiovasc Electrophysiol ; 34(12): 2443-2451, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37767727

RESUMO

INTRODUCTION: Regardless of the catheter ablation (CA) for atrial fibrillation (AF) strategy, the role of early recurrences during the blanking period (BP) is still unclear. Our aim was to evaluate atrial tachyarrhythmias (ATAs) recurrences during the BP after CA with the laser-balloon (LB) technique. METHODS: Consecutive patients undergoing LBCA were enrolled. Primary outcome of the study was the overall crude ATA recurrence rate during the BP. ATA recurrences after the BP and in-hospital readmissions during the BP were deemed secondary outcomes. RESULTS: Two hundred and twenty-four patients underwent CA with the LB. Median age was 63.0 (55.5-69.5) years and 74.1% were males. 28.6% were persistent AF patients, and 34.8% of patients were followed up with a loop recorder. 15.6% of patients experienced at least an ATA recurrence during the BP. Male sex, chronic heart failure, persistent AF, and recurrences during the BP were found to be associated with long-term ATA recurrences. Recurrences during the BP remained associated with the outcome of interest at multivariate analysis (hazard ratio [HR] = 12.393, 95% confidence interval [95% CI] = 3.699-41.865, p < .001). An association over time was found between early and late recurrences, with 73.7%, 45.5%, and 10.8% of patients presenting with recurrences at 1-, 2-, and 3-month follow-up being free from recurrences after the BP, respectively. 8.0% of patients were readmitted during the BP: 4.5% for AF electrical cardioversion, and 1.8% for CA of other atrial arrhythmias; no redo CA was performed. CONCLUSION: After adjusting for confounders, ATA recurrences during the BP represent the most significant predictor of ATA recurrences after the BP, regardless of AF pattern.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia , Lasers
12.
Life (Basel) ; 13(8)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37629509

RESUMO

The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.

13.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37481220

RESUMO

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

15.
Eur Heart J Suppl ; 25(Suppl C): C227-C233, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125274

RESUMO

Cardiac resynchronization therapy (CRT) via biventricular pacing (BVP) is a well-established therapy for patients with heart failure with reduced ejection fraction and left bundle branch block, who remain symptomatic despite optimal medical therapy. Despite the long-standing clinical evidence, as well as the familiarity of cardiac electrophysiologists with the implantation technique, CRT via BVP cannot be achieved or may result ineffective in up to one-third of the patients. Therefore, new alternative techniques, such as conduction system pacing and left ventricular pacing, are emerging as potential alternatives to this technique, not only in case of BVP failure, but also as a stand-alone first choice due to several potential advantages over traditional CRT. Specifically, due to its procedural characteristics, left bundle branch area pacing appears to be the most convincing technique, showing comparable efficacy outcomes when compared with traditional CRT, not increasing short-term device-related complications, as well as improving procedural times. However, transvenous leads remain a major limitation of all these pacing modalities. To overcome this limit, a leadless left ventricular endocardial pacing has been developed as an additional tool to achieve a left endocardial activation, although being still associated with non-negligible pitfalls, limiting its current use in clinical practice. This article focuses on the current state and latest progresses in cardiac resynchronization therapy.

16.
Eur Heart J Suppl ; 25(Suppl C): C331-C336, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125308

RESUMO

Heart failure (HF) is a major and still growing medical problem and is characterized by episodes of acute decompensation that are associated with a negative prognosis and a significant burden on the patients, doctors, and healthcare resources. Early detection of incipient HF may allow outpatient treatment before patients severely decompensate, thus reducing HF hospitalizations and related costs. The HeartLogic™ algorithm is an automatic, remotely managed system combining data directly related to HF pathophysiology into a single score, the HeartLogic™ index. This index proved to be effective in predicting the risk of incipient HF decompensation, allowing to redistribute resources from low-risk to high-risk patients in a timely and cost-saving manner. The alert-based remote management system seems more efficient than the one based on scheduled remote transmission in terms of caregivers' workload and alert detection timing. The widespread application of the HeartLogic™ algorithm requires the resolution of logistical and financial issues and the adoption of a pre-defined, functional workflow. In this paper, we reviewed general aspects of remote monitoring in HF patients, the functioning and pathophysiological basis of the HeartLogic index, its efficiency in the management of HF patients, and the economic effects and the organizational revolution associated with its use.

17.
Int J Mol Sci ; 24(9)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37175633

RESUMO

Genetic susceptibility may influence ischemic heart disease (IHD) predisposition and affect coronary blood flow (CBF) regulation mechanisms. The aim of this study was to investigate the association among single nucleotide polymorphisms (SNPs) of genes encoding for proteins involved in CBF regulation and IHD. A total of 468 consecutive patients were enrolled and divided into three groups according to coronary angiography and intracoronary functional tests results: G1, patients with coronary artery disease (CAD); G2, patients with coronary microvascular dysfunction (CMD); and G3, patients with angiographic and functionally normal coronary arteries. A genetic analysis of the SNPs rs5215 of the potassium inwardly rectifying channel subfamily J member 11 (KCNJ11) gene and rs1799983 of the nitric oxide synthase 3 (NOS3) gene, respectively encoding for the Kir6.2 subunit of ATP sensitive potassium (KATP) channels and nitric oxide synthase (eNOS), was performed on peripheral whole blood samples. A significant association of rs5215_G/G of KCNJ11 and rs1799983_T/T of NOS3 genes was detected in healthy controls compared with CAD and CMD patients. Based on univariable and multivariable analyses, the co-presence of rs5215_G/G of KCNJ11 and rs1799983_T/T of NOS3 may represent an independent protective factor against IHD, regardless of cardiovascular risk factors. This study supports the hypothesis that SNP association may influence the crosstalk between eNOS and the KATP channel that provides a potential protective effect against IHD.


Assuntos
Doença da Artéria Coronariana , Isquemia Miocárdica , Humanos , Trifosfato de Adenosina , Doença da Artéria Coronariana/genética , Predisposição Genética para Doença , Isquemia Miocárdica/genética , Óxido Nítrico Sintase/genética , Óxido Nítrico Sintase Tipo III/genética , Óxido Nítrico Sintase Tipo III/metabolismo , Polimorfismo de Nucleotídeo Único
18.
J Cardiovasc Electrophysiol ; 34(6): 1386-1394, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194742

RESUMO

INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.


Assuntos
Síndrome de Brugada , COVID-19 , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/terapia , Estudos Retrospectivos , Incidência , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Sistema de Registros , Vacinação , Seguimentos
19.
Rev Port Cardiol ; 42(8): 711-717, 2023 08.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37085085

RESUMO

INTRODUCTION AND OBJECTIVES: The incidence of device infection has increased over time and is associated with increased mortality in patients with cardiac implantable electronic devices (CIEDs). Gentamicin-impregnated collagen sponges (GICSs) are useful in preventing surgical site infection (SSI) in cardiac surgery. Nevertheless, to date, there is no evidence concerning their use in CIED procedures. Our study aims to determine the effectiveness of treatment with GICSs in preventing CIED infection. METHODS: A total of 2986 adult patients who received CIEDs between 2010 and 2020 were included. Before device implantation, all patients received routine periprocedural systemic antibiotic prophylaxis. The study endpoints were the CIED infection rate at one year and the effectiveness of the use of GICSs in reducing CIED infection. RESULTS: Among 1524 pacemaker, 942 ICD and 520 CRT implantations, CIED infection occurred in 36 patients (1.2%). Early reintervention (OR 9 [95% CI 3.180-25.837], p<0.001), pocket hematoma (OR 11 [95% CI 4.195-28.961], p<0.001), diabetes (OR 2.9 [95% CI 1.465-5.799], p=0.002) and prolonged procedural time (OR 1.02 [95% CI 1.008-1.034], p=0.001) were independent risk factors for CIED infection. Treatment with GICSs reduced CIED infections significantly ([95% CI -0.031 to -0.001], p<0.001). CONCLUSIONS: The use of GICSs may help in reducing infections associated with CIED implantation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Adulto , Humanos , Desfibriladores Implantáveis/efeitos adversos , Gentamicinas , Pontuação de Propensão , Marca-Passo Artificial/efeitos adversos , Fatores de Risco , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA