Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 259(10): 3175-3183, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33825029

RESUMO

PURPOSE: To evaluate the potential impact of rebubbling on the anterior segment parameters and refractive outcomes in patients with graft detachment following uneventful DMEK for Fuchs endothelial dystrophy (FED). METHODS: Retrospective institutional cohort study of comparing 34 eyes of 31 patients with rebubbling for graft detachment following Descemet membrane endothelial keratoplasty (DMEK) to 33 eyes of 28 patients with uneventful DMEK. Main outcome parameters were various corneal parameters obtained by Scheimpflug imaging, refractive outcome, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). RESULTS: Anterior and posterior corneal astigmatism, corneal densitometry, central corneal thickness, and anterior chamber depth and volume showed no significant differences. Preoperative distribution of astigmatism axis orientations showed a high proportion of anterior corneal with-the-rule astigmatism (71%) in eyes requiring rebubbling. Mean postoperative cylinder in the rebubbling group (1.21 ± 0.85 D) was significantly higher compared to the controls (p = 0.04), while differences in spherical equivalent (SE) were insignificant (p = 0.24). Postoperative CDVA was 0.11 ± 0.11 in the control group compared to 0.21 ± 0.17 in the rebubbling group (p = 0.03). Eyes with subsequent rebubbling demonstrated a significantly higher endothelial cell loss (56% versus 37%) (p < 0.001). CONCLUSION: Apart from higher cylinder values, refractive outcome and corneal parameters assessed by Scheimpflug imaging were comparable in eyes with rebubbling and controls. However, a reduced visual acuity and an increased endothelial cell loss should be taken into consideration prior to rebubbling especially in eyes with circumscribed graft detachment.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Estudos de Coortes , Lâmina Limitante Posterior , Endotélio Corneano , Distrofia Endotelial de Fuchs/diagnóstico , Distrofia Endotelial de Fuchs/cirurgia , Humanos , Estudos Retrospectivos
2.
Am J Ophthalmol ; 211: 42-55, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31678559

RESUMO

PURPOSE: To evaluate the safety and efficacy of femtosecond (fs) laser-assisted in situ keratomileusis (LASIK) combined with accelerated corneal cross-linking (LASIK Xtra) compared to conventional fs-LASIK (convLASIK) in high myopic patients. DESIGN: Prospective, randomized, fellow-eye controlled clinical trial. METHODS: Setting: Department of Ophthalmology, Goethe University, Frankfurt/Germany. StudyPopulation: Twenty-six patients with high myopia and/or myopic astigmatism received randomized treatment with LASIK Xtra (30 mW/cm2, 90 seconds with continuous ultraviolet-A) in 1 eye and convLASIK in the other eye. MainOutcomeMeasures: Uncorrected distance visual acuity (UDVA), best spectacle-corrected VA (BSCVA), manifest refractive spherical equivalent (MRSE), endothelial cell count (ECC), and corneal thickness. RESULTS: The UDVA improved from 1.26 ± 0.13 logMAR preoperative to -0.02 ± 0.15logMAR in LASIK Xtra eyes and from 1.27 ± 0.12 logMAR to 0.01 ± 0.15 logMAR in the convLASIK eyes (P > .05). The MRSE changed from -7.35 ± 1.15 diopters (D) and -7.5 ± 1.12 D to -0.17 ± 0.43 D and -0.25 ± 0.46 D, respectively. There was no significant difference in outcomes between both groups during the 12 months follow-up except for the convLASIK eyes' showing slightly better BSCVA after 1 week (P < .05). ConvLASIK eyes revealed a nonsignificant trend toward myopic regression from 3 to 12 months postoperative with a change in MRSE of -0.15 D compared to -0.1 D in LASIK Xtra eyes. Topography showed stability of corneal curvature with no signs of keratectasia in both groups at 12 months. CONCLUSION: While apparently safe, LASIK Xtra showed no advantages over conventional LASIK. At 12 months, both groups showed no difference regarding UDVA and refractive stability, and no signs of keratectasia.


Assuntos
Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia Degenerativa/terapia , Fotoquimioterapia/métodos , Adulto , Contagem de Células , Colágeno/metabolismo , Terapia Combinada , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/tratamento farmacológico , Miopia Degenerativa/metabolismo , Miopia Degenerativa/cirurgia , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Resultado do Tratamento , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA