Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
Sci Rep ; 14(1): 11915, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789499

RESUMO

Speckle contrast optical spectroscopy (SCOS) is an emerging camera-based technique that can measure human cerebral blood flow (CBF) with high signal-to-noise ratio (SNR). At low photon flux levels typically encountered in human CBF measurements, camera noise and nonidealities could significantly impact SCOS measurement SNR and accuracy. Thus, a guide for characterizing, selecting, and optimizing a camera for SCOS measurements is crucial for the development of next-generation optical devices for monitoring human CBF and brain function. Here, we provide such a guide and illustrate it by evaluating three commercially available complementary metal-oxide-semiconductor cameras, considering a variety of factors including linearity, read noise, and quantization distortion. We show that some cameras that are well-suited for general intensity imaging could be challenged in accurately quantifying spatial contrast for SCOS. We then determine the optimal operating parameters for the preferred camera among the three and demonstrate measurement of human CBF with this selected low-cost camera. This work establishes a guideline for characterizing and selecting cameras as well as for determining optimal parameters for SCOS systems.


Assuntos
Circulação Cerebrovascular , Razão Sinal-Ruído , Análise Espectral , Humanos , Circulação Cerebrovascular/fisiologia , Análise Espectral/métodos , Análise Espectral/instrumentação , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Encéfalo/irrigação sanguínea
2.
Biomed Opt Express ; 15(3): 1959-1975, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38495689

RESUMO

Infants born at an extremely low gestational age (ELGA, < 29 weeks) are at an increased risk of intraventricular hemorrhage (IVH), and there is a need for standalone, safe, easy-to-use tools for monitoring cerebral hemodynamics. We have built a multi-wavelength multi-distance diffuse correlation spectroscopy device (MW-MD-DCS), which utilizes time-multiplexed, long-coherence lasers at 785, 808, and 853 nm, to simultaneously quantify the index of cerebral blood flow (CBFi) and the hemoglobin oxygen saturation (SO2). We show characterization data on liquid phantoms and demonstrate the system performance on the forearm of healthy adults, as well as clinical data obtained on two preterm infants.

3.
Biomed Opt Express ; 15(3): 1355-1369, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38495722

RESUMO

Carotid endarterectomy (CEA) involves removal of plaque in the carotid artery to reduce the risk of stroke and improve cerebral perfusion. This study aimed to investigate the utility of assessing pulsatile blood volume and flow during CEA. Using a combined near-infrared spectroscopy/diffuse correlation spectroscopy instrument, pulsatile hemodynamics were assessed in 12 patients undergoing CEA. Alterations to pulsatile amplitude, pulse transit time, and beat morphology were observed in measurements ipsilateral to the surgical side. The additional information provided through analysis of pulsatile hemodynamic signals has the potential to enable the discovery of non-invasive biomarkers related to cortical perfusion.

4.
Neurophotonics ; 11(1): 015004, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38282721

RESUMO

Significance: The non-invasive measurement of cerebral blood flow based on diffuse optical techniques has seen increased interest as a research tool for cerebral perfusion monitoring in critical care and functional brain imaging. Diffuse correlation spectroscopy (DCS) and speckle contrast optical spectroscopy (SCOS) are two such techniques that measure complementary aspects of the fluctuating intensity signal, with DCS quantifying the temporal fluctuations of the signal and SCOS quantifying the spatial blurring of a speckle pattern. With the increasing interest in the use of these techniques, a thorough comparison would inform new adopters of the benefits of each technique. Aim: We systematically evaluate the performance of DCS and SCOS for the measurement of cerebral blood flow. Approach: Monte Carlo simulations of dynamic light scattering in an MRI-derived head model were performed. For both DCS and SCOS, estimates of sensitivity to cerebral blood flow changes, coefficient of variation of the measured blood flow, and the contrast-to-noise ratio of the measurement to the cerebral perfusion signal were calculated. By varying complementary aspects of data collection between the two methods, we investigated the performance benefits of different measurement strategies, including altering the number of modes per optical detector, the integration time/fitting time of the speckle measurement, and the laser source delivery strategy. Results: Through comparison across these metrics with simulated detectors having realistic noise properties, we determine several guiding principles for the optimization of these techniques and report the performance comparison between the two over a range of measurement properties and tissue geometries. We find that SCOS outperforms DCS in terms of contrast-to-noise ratio for the cerebral blood flow signal in the ideal case simulated here but note that SCOS requires careful experimental calibrations to ensure accurate measurements of cerebral blood flow. Conclusion: We provide design principles by which to evaluate the development of DCS and SCOS systems for their use in the measurement of cerebral blood flow.

5.
Neurophotonics ; 10(3): 035008, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37680339

RESUMO

Significance: Combining near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) allows for quantifying cerebral blood volume, flow, and oxygenation changes continuously and non-invasively. As recently shown, the DCS pulsatile cerebral blood flow index (pCBFi) can be used to quantify critical closing pressure (CrCP) and cerebrovascular resistance (CVRi). Aim: Although current DCS technology allows for reliable monitoring of the slow hemodynamic changes, resolving pulsatile blood flow at large source-detector separations, which is needed to ensure cerebral sensitivity, is challenging because of its low signal-to-noise ratio (SNR). Cardiac-gated averaging of several arterial pulse cycles is required to obtain a meaningful waveform. Approach: Taking advantage of the high SNR of NIRS, we demonstrate a method that uses the NIRS photoplethysmography (NIRS-PPG) pulsatile signal to model DCS pCBFi, reducing the coefficient of variation of the recovered pulsatile waveform (pCBFi-fit) and allowing for an unprecedented temporal resolution (266 Hz) at a large source-detector separation (>3 cm). Results: In 10 healthy subjects, we verified the quality of the NIRS-PPG pCBFi-fit during common tasks, showing high fidelity against pCBFi (R2 0.98±0.01). We recovered CrCP and CVRi at 0.25 Hz, >10 times faster than previously achieved with DCS. Conclusions: NIRS-PPG improves DCS pCBFi SNR, reducing the number of gate-averaged heartbeats required to recover CrCP and CVRi.

8.
Sci Rep ; 13(1): 8803, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37258644

RESUMO

Diffuse correlation spectroscopy (DCS) is an optical technique that can be used to characterize blood flow in tissue. The measurement of cerebral hemodynamics has arisen as a promising use case for DCS, though traditional implementations of DCS exhibit suboptimal signal-to-noise ratio (SNR) and cerebral sensitivity to make robust measurements of cerebral blood flow in adults. In this work, we present long wavelength, interferometric DCS (LW-iDCS), which combines the use of a longer illumination wavelength (1064 nm), multi-speckle, and interferometric detection, to improve both cerebral sensitivity and SNR. Through direct comparison with long wavelength DCS based on superconducting nanowire single photon detectors, we demonstrate an approximate 5× improvement in SNR over a single channel of LW-DCS in the measured blood flow signals in human subjects. We show equivalence of extracted blood flow between LW-DCS and LW-iDCS, and demonstrate the feasibility of LW-iDCS measured at 100 Hz at a source-detector separation of 3.5 cm. This improvement in performance has the potential to enable robust measurement of cerebral hemodynamics and unlock novel use cases for diffuse correlation spectroscopy.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Hemodinâmica , Adulto , Humanos , Análise Espectral/métodos , Interferometria , Razão Sinal-Ruído
9.
Neurophotonics ; 9(Suppl 2): S24001, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36052058

RESUMO

This report is the second part of a comprehensive two-part series aimed at reviewing an extensive and diverse toolkit of novel methods to explore brain health and function. While the first report focused on neurophotonic tools mostly applicable to animal studies, here, we highlight optical spectroscopy and imaging methods relevant to noninvasive human brain studies. We outline current state-of-the-art technologies and software advances, explore the most recent impact of these technologies on neuroscience and clinical applications, identify the areas where innovation is needed, and provide an outlook for the future directions.

10.
Brain Sci ; 12(8)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-36009088

RESUMO

Objective: This pilot study aims to show the feasibility of noninvasive and real-time cerebral hemodynamic monitoring during carotid endarterectomy (CEA) via diffuse correlation spectroscopy (DCS) and near-infrared spectroscopy (NIRS). Methods: Cerebral blood flow index (CBFi) was measured unilaterally in seven patients and bilaterally in seventeen patients via DCS. In fourteen patients, hemoglobin oxygenation changes were measured bilaterally and simultaneously via NIRS. Cerebral autoregulation (CAR) and cerebrovascular resistance (CVR) were estimated using CBFi and arterial blood pressure data. Further, compensatory responses to the ipsilateral hemisphere were investigated at different contralateral stenosis levels. Results: Clamping of carotid arteries caused a sharp increase of CVR (~70%) and a marked decrease of ipsilateral CBFi (57%). From the initial drop, we observed partial recovery in CBFi, an increase of blood volume, and a reduction in CVR in the ipsilateral hemisphere. There were no significant changes in compensatory responses between different contralateral stenosis levels as CAR was intact in both hemispheres throughout the CEA phase. A comparison between hemispheric CBFi showed lower ipsilateral levels during the CEA and post-CEA phases (p < 0.001, 0.03). Conclusion: DCS alone or combined with NIRS is a useful monitoring technique for real-time assessment of cerebral hemodynamic changes and allows individualized strategies to improve cerebral perfusion during CEA by identifying different hemodynamic metrics.

11.
Sci Rep ; 12(1): 12798, 2022 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-35896691

RESUMO

In premature infants with an extremely low gestational age (ELGA, < 29 weeks GA), dysregulated changes in cerebral blood flow (CBF) are among the major pathogenic factors leading to germinal matrix/intraventricular hemorrhage (GM/IVH). Continuous monitoring of CBF can guide interventions to minimize the risk of brain injury, but there are no clinically standard techniques or tools for its measurement. We report the feasibility of the continuous monitoring of CBF, including measures of autoregulation, via diffuse correlation spectroscopy (DCS) in ELGA infants using CBF variability and correlation with scalp blood flow (SBF, served as a surrogate measure of systemic perturbations). In nineteen ELGA infants (with 9 cases of GM/IVH) monitored for 6-24 h between days 2-5 of life, we found a strong correlation between CBF and SBF in severe IVH (Grade III or IV) and IVH diagnosed within 72 h of life, while CBF variability alone was not associated with IVH. The proposed method is potentially useful at the bedside for the prompt assessment of cerebral autoregulation and early identification of infants vulnerable to GM/IVH.


Assuntos
Hemorragia Cerebral , Doenças do Prematuro , Hemorragia Cerebral/diagnóstico , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Análise Espectral
12.
J Perinatol ; 42(10): 1385-1391, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35790852

RESUMO

OBJECTIVE: To assess the association between cerebral saturation (crSO2) using Near-Infrared Spectroscopy (NIRS) and brain injury in extremely preterm infants. STUDY DESIGN: This retrospective study includes 62 infants (<28 weeks gestation) who underwent continuous NIRS monitoring in the first 5 days after birth. Median crSO2 were compared in 12 h increments between infants with and without germinal matrix/intraventricular hemorrhage (GM/IVH). crSO2 was also compared by IVH severity, onset, and by grade of injury on term equivalent MRI. RESULTS: After 48 h of life (HOL), infants with GM/IVH had significantly lower crSO2 than those without GM/IVH in analysis adjusted for potential confounding e.g., at 49-60 HOL (69.5 (66.2, 72.8) vs. 74.7 (71.8, 77.6), p = 0.023). There were no significant differences in crSO2 by IVH subcategory or injury severity on MRI. CONCLUSION: Clinical use of NIRS has the potential to identify crSO2 patterns associated with development of GM/IVH.


Assuntos
Lesões Encefálicas , Lactente Extremamente Prematuro , Encéfalo/diagnóstico por imagem , Lesões Encefálicas/diagnóstico por imagem , Hemorragia Cerebral/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Lactente , Recém-Nascido , Oxigênio , Saturação de Oxigênio , Estudos Retrospectivos
13.
Neuroimage ; 256: 119216, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35452803

RESUMO

Currently, there is great interest in making neuroimaging widely accessible and thus expanding the sampling population for better understanding and preventing diseases. The use of wearable health devices has skyrocketed in recent years, allowing continuous assessment of physiological parameters in patients and research cohorts. While most health wearables monitor the heart, lungs and skeletal muscles, devices targeting the brain are currently lacking. To promote brain health in the general population, we developed a novel, low-cost wireless cerebral oximeter called FlexNIRS. The device has 4 LEDs and 3 photodiode detectors arranged in a symmetric geometry, which allows for a self-calibrated multi-distance method to recover cerebral hemoglobin oxygenation (SO2) at a rate of 100 Hz. The device is powered by a rechargeable battery and uses Bluetooth Low Energy (BLE) for wireless communication. We developed an Android application for portable data collection and real-time analysis and display. Characterization tests in phantoms and human participants show very low noise (noise-equivalent power <70 fW/√Hz) and robustness of SO2 quantification in vivo. The estimated cost is on the order of $50/unit for 1000 units, and our goal is to share the device with the research community following an open-source model. The low cost, ease-of-use, smart-phone readiness, accurate SO2 quantification, real time data quality feedback, and long battery life make prolonged monitoring feasible in low resource settings, including typically medically underserved communities, and enable new community and telehealth applications.


Assuntos
Encéfalo/fisiologia , Oximetria/métodos , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Cabeça , Hemoglobinas/análise , Humanos , Oximetria/economia , Oximetria/instrumentação , Imagens de Fantasmas , Dispositivos Eletrônicos Vestíveis/economia , Tecnologia sem Fio/economia
16.
Biomed Opt Express ; 13(3): 1131-1151, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414976

RESUMO

We characterize cerebral sensitivity across the entire adult human head for diffuse correlation spectroscopy, an optical technique increasingly used for bedside cerebral perfusion monitoring. Sixteen subject-specific magnetic resonance imaging-derived head models were used to identify high sensitivity regions by running Monte Carlo light propagation simulations at over eight hundred uniformly distributed locations on the head. Significant spatial variations in cerebral sensitivity, consistent across subjects, were found. We also identified correlates of such differences suitable for real-time assessment. These variations can be largely attributed to changes in extracerebral thickness and should be taken into account to optimize probe placement in experimental settings.

17.
Sensors (Basel) ; 22(6)2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35336531

RESUMO

Capacitive proximity sensing is widespread in our everyday life, but no sensor for biomedical optics takes advantage of this technology to monitor the probe attachment to the subject's skin. In particular, when using optical monitoring devices, the capability to quantitatively measure the probe contact can significantly improve data quality and ensure the subject's safety. We present a custom novel optical probe based on a flexible printed circuit board which integrates a capacitive contact sensor, 3D-printed optic fiber holders and an accelerometer sensor. The device can be effectively adopted during continuous monitoring optical measurements to detect contact quality, motion artifacts, probe detachment and ensure optimal signal quality.


Assuntos
Artefatos , Tecnologia de Fibra Óptica , Monitorização Fisiológica , Movimento (Física)
18.
IEEE Trans Biomed Eng ; 69(6): 1943-1953, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34847015

RESUMO

OBJECTIVE: Diffuse correlation spectroscopy (DCS) is an optical technique that allows for the non-invasive measurement of blood flow. Recent work has shown that utilizing longer wavelengths beyond the traditional NIR range provides a significant improvement to signal-to-noise ratio (SNR). However, current detectors both sensitive to longer wavelengths and suitable for clinical applications (InGaAs/InP SPADs) suffer from suboptimal afterpulsing and dark noise characteristics. To overcome these barriers, we introduce a cross correlation method to more accurately recover blood flow information using InGaAs/InP SPADs. METHODS: Two InGaAs/InP SPAD detectors were used for during in vitro and in vivo DCS measurements. Cross correlation of the photon streams from each detector was performed to calculate the correlation function. Detector operating parameters were varied to determine parameters which maximized measurement SNR.State-space modeling was performed to determine the detector characteristics at each operating point. RESULTS: Evaluation of detector characteristics was performed across the range of operating conditions. Modeling the effects of the detector noise on the correlation function provided a method to correct the distortion of the correlation curve, yielding accurate recovery of flow information as confirmed by a reference detector. CONCLUSION: Through a combination of cross-correlation of the signals from two detectors, model-based characterization of detector response, and optimization of detector operating parameters, the method allows for the accurate estimation of the true blood flow index. SIGNIFICANCE: This work presents a method by which DCS can be performed at longer NIR wavelengths with existing detector technology, taking advantage of the increased SNR.


Assuntos
Fótons , Água , Hemodinâmica , Razão Sinal-Ruído , Análise Espectral
19.
Neurophotonics ; 8(3): 035006, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34423069

RESUMO

Significance: The ability of diffuse correlation spectroscopy (DCS) to measure cerebral blood flow (CBF) in humans is hindered by the low signal-to-noise ratio (SNR) of the method. This limits the high acquisition rates needed to resolve dynamic flow changes and to optimally filter out large pulsatile oscillations and prevents the use of large source-detector separations ( ≥ 3 cm ), which are needed to achieve adequate brain sensitivity in most adult subjects. Aim: To substantially improve SNR, we have built a DCS device that operates at 1064 nm and uses superconducting nanowire single-photon detectors (SNSPD). Approach: We compared the performances of the SNSPD-DCS in humans with respect to a typical DCS system operating at 850 nm and using silicon single-photon avalanche diode detectors. Results: At a 25-mm separation, we detected 13 ± 6 times more photons and achieved an SNR gain of 16 ± 8 on the forehead of 11 subjects using the SNSPD-DCS as compared to typical DCS. At this separation, the SNSPD-DCS is able to detect a clean pulsatile flow signal at 20 Hz in all subjects. With the SNSPD-DCS, we also performed measurements at 35 mm, showing a lower scalp sensitivity of 31 ± 6 % with respect to the 48 ± 8 % scalp sensitivity at 25 mm for both the 850 and 1064 nm systems. Furthermore, we demonstrated blood flow responses to breath holding and hyperventilation tasks. Conclusions: While current commercial SNSPDs are expensive, bulky, and loud, they may allow for more robust measures of non-invasive cerebral perfusion in an intensive care setting.

20.
Neurophotonics ; 8(3): 035005, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34395719

RESUMO

Significance: Time domain diffuse correlation spectroscopy (TD-DCS) can offer increased sensitivity to cerebral hemodynamics and reduced contamination from extracerebral layers by differentiating photons based on their travel time in tissue. We have developed rigorous simulation and evaluation procedures to determine the optimal time gate parameters for monitoring cerebral perfusion considering instrumentation characteristics and realistic measurement noise. Aim: We simulate TD-DCS cerebral perfusion monitoring performance for different instrument response functions (IRFs) in the presence of realistic experimental noise and evaluate metrics of sensitivity to brain blood flow, signal-to-noise ratio (SNR), and ability to reject the influence of extracerebral blood flow across a variety of time gates to determine optimal operating parameters. Approach: Light propagation was modeled on an MRI-derived human head geometry using Monte Carlo simulations for 765- and 1064-nm excitation wavelengths. We use a virtual probe with a source-detector separation of 1 cm placed in the pre-frontal region. Performance metrics described above were evaluated to determine optimal time gate(s) for different IRFs. Validation of simulation noise estimates was done with experiments conducted on an intralipid-based liquid phantom. Results: We find that TD-DCS performance strongly depends on the system IRF. Among Gaussian pulse shapes, ∼ 300 ps pulse length appears to offer the best performance, at wide gates (500 ps and larger) with start times 400 and 600 ps after the peak of the TPSF at 765 and 1064 nm, respectively, for a 1-s integration time at photon detection rates seen experimentally (600 kcps at 765 nm and 4 Mcps at 1064 nm). Conclusions: Our work shows that optimal time gates satisfy competing requirements for sufficient sensitivity and sufficient SNR. The achievable performance is further impacted by system IRF with ∼ 300 ps quasi-Gaussian pulse obtained using electro-optic laser shaping providing the best results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA