Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Int J Legal Med ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862819

RESUMO

Klales et al. (2012) is a popular standard for the estimation of skeletal sex. Since its publication, a number of studies have demonstrated that population-specific applications of Klales improve classification accuracy. However, it has also been shown that age appears to affect the expression of dimorphism in the pelvis across the lifespan. As such, the present study examines the accuracy of Klales, and the modified global standard of Kenyhercz et al. (2017), in a contemporary Indonesian population, including quantifying the effect of age. Pelvic multi-slice CT scans of 378 individuals (213 female; 165 male) were analysed in OsiriX®. Both standards were tested and Indonesian-specific models thereafter derived.When applied to the Indonesian sample, both the Klales and Kenyhercz standards resulted in lower classification accuracy relative to the original studies. In considering the Indonesian-specific models, the ventral arc was the most accurate for the classification of sex, at 93.3% with a - 3.0% sex bias. The accuracy of the three-trait model was 94.4%, with a - 5.5% sex bias. Age was shown to significantly affect the distribution of pelvic trait scores. As such, age-dependent models were also derived, with the standard for individuals between 30 and 49 years the most accurate, at 93.1% and a sex bias of - 4.0%. Accuracy was lower in individuals aged ≥ 50 years, at 91.3% and a sex bias of 4.1%. These findings support the importance of establishing population-specific standards and to facilitate improved accuracy and capabilities for forensic practitioners in Indonesia.

2.
Phys Med Biol ; 69(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38776943

RESUMO

Objective.To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.Approach.Phantoms of polyethylene, gelatin, or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent11C,10C and15O radionuclides contributions in each voxel were determined from the extracted time activity curves. Next, the experimental configurations were simulated in Geant4 Monte Carlo versions 10.0 to 11.1, with three different fragmentation models-binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 model-version combinations. Total positron annihilation and parent isotope production yields predicted by each simulation were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Finally, we compared the depth of the maximum positron annihilation yield and the distal point at which the positron yield decreases to 50% of peak between each model and the experimental results.Main results.Performance varied considerably across versions and models, with no one version/model combination providing the best prediction of all positron-emitting fragments in all evaluated target materials and irradiation conditions. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions.Significance.The best predictions of the spatial distribution of positron annihilations and positron-emitting fragment production along the beam path during carbon and oxygen ion therapy was obtained using Geant4 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.


Assuntos
Método de Monte Carlo , Elétrons/uso terapêutico , Radioterapia com Íons Pesados/métodos , Tomografia por Emissão de Pósitrons , Imagens de Fantasmas
3.
Int J Legal Med ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38763925

RESUMO

The present study analyzes morphological differences femora of contemporary Japanese and Western Australian individuals and investigates the feasibility of population affinity estimation based on computed tomographic (CT) data. The latter is deemed to be of practical importance because most anthropological methods rely on the assessment of aspects of skull morphology, which when damaged and/or unavailable, often hampers attempts to estimate population affinity. The study sample comprised CT scans of 297 (146 females; 151 males) Japanese and 330 (145 females; 185 males) Western Australian adult individuals. A total of 10 measurements were acquired in two-dimensional CT images of the left and right femora; two machine learning methods (random forest modeling [RFM]) and support vector machine [SVM]) were then applied for population affinity classification. The accuracy of the two-way (sex-specific and sex-mixed) model was between 71.38 and 82.07% and 76.09-86.09% for RFM and SVM, respectively. Sex-specific (female and male) models were slightly more accurate compared to the sex-mixed models; there were no considerable differences in the correct classification rates between the female- and male-specific models. All the classification accuracies were higher in the Western Australian population, except for the male model using SVM. The four-way sex and population affinity model had an overall classification accuracy of 74.96% and 79.11% for RFM and SVM, respectively. The Western Australian females had the lowest correct classification rate followed by the Japanese males. Our data indicate that femoral measurements may be particularly useful for classification of Japanese and Western Australian individuals.

4.
Int J Legal Med ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613625

RESUMO

Chile had a violent military coup (1973-1990) that resulted in 3,000 victims declared detained, missing or killed; many are still missing and unidentified. Currently, the Human Rights Unit of the Forensic Medical Service in Chile applies globally recognised forensic anthropological approaches, but many of these methods have not been validated in a Chilean sample. As current research has demonstrated population-specificity with extant methods, the present study aims to validate sex estimation methods in a Chilean population and thereafter establish population-specific equations. A sample of 265 os coxae of known age and sex of adult Chileans from the Santiago Subactual Osteology Collection were analysed. Visual assessment and scoring of the pelvic traits were performed in accordance with the Phenice (1969) and Klales et al. (2012) methods. The accuracy of Phenice (1969) in the Chilean sample was 96.98%, with a sex bias of 7.68%. Klales et al. (2012) achieved 87.17% accuracy with a sex bias of -15.39%. Although both methods showed acceptable classification accuracy, the associated sex bias values are unacceptable in forensic practice. Therefore, six univariate and eight multivariate predictive models were formulated for the Chilean population. The most accurate univariate model was the ventral arc at 96.6%, with a sex bias of 5.2%. Classification accuracy using all traits was 97.0%, with a sex bias of 7.7%. This study provides Chilean practitioners a population-specific morphoscopic standard with associated classification probabilities acceptable to accomplish legal admissibility requirements in human rights and criminal cases specific to the second half of the 20th century.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38479560

RESUMO

PURPOSE: Neutron capture enhanced particle therapy (NCEPT) is a proposed augmentation of charged particle therapy that exploits thermal neutrons generated internally, within the treatment volume via nuclear fragmentation, to deliver a biochemically targeted radiation dose to cancer cells. This work is the first experimental demonstration of NCEPT, performed using both carbon and helium ion beams with 2 different targeted neutron capture agents (NCAs). METHODS AND MATERIALS: Human glioblastoma cells (T98G) were irradiated by carbon and helium ion beams in the presence of NCAs [10B]-BPA and [157Gd]-DOTA-TPP. Cells were positioned within a polymethyl methacrylate phantom either laterally adjacent to or within a 100 × 100 × 60 mm spread out Bragg peak (SOBP). The effect of NCAs and location relative to the SOBP on the cells was measured by cell growth and survival assays in 6 independent experiments. Neutron fluence within the phantom was characterized by quantifying the neutron activation of gold foil. RESULTS: Cells placed inside the treatment volume reached 10% survival by 2 Gy of carbon or 2 to 3 Gy of helium in the presence of NCAs compared with 5 Gy of carbon and 7 Gy of helium with no NCA. Cells placed adjacent to the treatment volume showed a dose-dependent decrease in cell growth when treated with NCAs, reaching 10% survival by 6 Gy of carbon or helium (to the treatment volume), compared with no detectable effect on cells without NCA. The mean thermal neutron fluence at the center of the SOBP was approximately 2.2 × 109 n/cm2/Gy (relative biological effectiveness) for the carbon beam and 5.8 × 109 n/cm2/Gy (relative biological effectiveness) for the helium beam and gradually decreased in all directions. CONCLUSIONS: The addition of NCAs to cancer cells during carbon and helium beam irradiation has a measurable effect on cell survival and growth in vitro. Through the capture of internally generated neutrons, NCEPT introduces the concept of a biochemically targeted radiation dose to charged particle therapy. NCEPT enables the established pharmaceuticals and concepts of neutron capture therapy to be applied to a wider range of deeply situated and diffuse tumors, by targeting this dose to microinfiltrates and cells outside of defined treatment regions. These results also demonstrate the potential for NCEPT to provide an increased dose to tumor tissue within the treatment volume, with a reduction in radiation doses to off-target tissue.

6.
Int J Legal Med ; 138(4): 1381-1390, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38316656

RESUMO

The present study analyzes morphological differences in the pelvis of Japanese and Western Australian individuals and investigates the feasibility of population affinity classification based on computed tomography (CT) data. The Japanese and Western Australian samples comprise CT scans of 207 (103 females; 104 males) and 158 (78 females; 80 males) adult individuals, respectively. Following volumetric reconstruction, a total of 19 pelvic landmarks were obtained on each sample, and 11 measurements, including two angles, were calculated. Machine learning methods (random forest modeling [RFM] and support vector machine [SVM]) were used to classify population affinity. Classification accuracy of the two-way models was approximately 80% for RFM: the two-way sex-specific and sex-mixed models for SVM achieved > 90% and > 85%, respectively. The sex-specific models had higher accurate classification rates than the sex-mixed models, except for the Japanese male sample. The classification accuracy of the four-way sex and population affinity model had an overall classification accuracy of 76.71% for RFM and 87.67% for SVM. All the correct classification rates were higher in the Japanese relative to the Western Australian sample. Our data suggest that pelvic morphology is sufficiently distinct between Japanese and Western Australian individuals to facilitate the accurate classification of population affinity based on measurements acquired in CT images. To the best of our knowledge, this is the first study investigating the feasibility of population affinity estimation based on CT images of the pelvis, which appears as a viable supplement to traditional approaches based on cranio-facial morphology.


Assuntos
Antropologia Forense , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Adulto , Antropologia Forense/métodos , Máquina de Vetores de Suporte , Pessoa de Meia-Idade , Austrália Ocidental , Japão , Povo Asiático , Idoso , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/anatomia & histologia , Pontos de Referência Anatômicos , Aprendizado de Máquina , Adulto Jovem , População do Leste Asiático
7.
Int J Legal Med ; 138(4): 1559-1571, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38300302

RESUMO

There is renewed interest in Asia for the development of forensic anthropological standards, partly due to the need for population-specific models to maintain high classification accuracies. At present, there are no known studies utilising morphoscopic standards specific to the Indonesian population. Craniometric analyses can often be time-consuming; morphoscopic assessments are quicker and are also known to be reliable and accurate. One of the most utilised morphoscopic standards for the estimation of skeletal sex is that of Walker (2008). Its application across population groups demonstrated reduced accuracies outside of the United States; population-specific predictive models would thus serve to improve the identification process of unknown skeletal remains. Digital imaging also allows for the validation of standards on a contemporary population and is an appropriate proxy to physical skeletal material.The present study quantifies the applicability of the Walker standard to a contemporary Indonesian population. A total of 200 cranial MSCT scans from a hospital in Makassar were analysed using OsiriX®. Scoring was performed in accordance with the Walker standard. Five univariate and nine multivariate predictive models were derived using single trait and multi-trait combinations. The best performing univariate model included the glabella, with a total classification accuracy of 82.0% and a sex bias of 14.6%. Classification accuracy with all traits considered was at 95.2% for females and 82.8% for males with a sex bias of 12.5%. These results provide forensic practitioners in Indonesia with an appropriate morphoscopic sex estimation standard, strengthening their capabilities in the field and improving judicial outcomes.


Assuntos
Antropologia Forense , Determinação do Sexo pelo Esqueleto , Crânio , Humanos , Indonésia , Masculino , Determinação do Sexo pelo Esqueleto/métodos , Feminino , Crânio/diagnóstico por imagem , Crânio/anatomia & histologia , Adulto , Antropologia Forense/métodos , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Adulto Jovem , Idoso , Adolescente , Cefalometria
8.
Int J Legal Med ; 138(3): 1193-1203, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38252284

RESUMO

The estimation of ancestry is important not only towards establishing identity but also as a required precursor to facilitating the accurate estimation of other attributes such as sex, age at death, and stature. The present study aims to analyze morphological variation in the crania of Japanese and Western Australian individuals and test predictive models based on machine learning for their potential forensic application. The Japanese and Western Australian samples comprise computed tomography (CT) scans of 230 (111 female; 119 male) and 225 adult individuals (112 female; 113 male), respectively. A total of 18 measurements were calculated, and machine learning methods (random forest modeling, RFM; support vector machine, SVM) were used to classify ancestry. The two-way unisex model achieved an overall accuracy of 93.2% for RFM and 97.1% for SVM, respectively. The four-way sex and ancestry model demonstrated an overall classification accuracy of 84.0% for RFM and 93.0% for SVM. The sex-specific models were most accurate in the female samples (♀ 95.1% for RFM and 100% for SVM; ♂91.4% for RFM and 97.4% for SVM). Our findings suggest that cranial measurements acquired in CT images can be used to accurately classify Japanese and Western Australian individuals into their respective population. This is the first study to assess the feasibility of ancestry estimation using three-dimensional CT images of the skull.


Assuntos
Tomografia Computadorizada Multidetectores , Determinação do Sexo pelo Esqueleto , Adulto , Humanos , Masculino , Feminino , Japão , Antropologia Forense/métodos , Austrália , Crânio/diagnóstico por imagem , Crânio/anatomia & histologia , Determinação do Sexo pelo Esqueleto/métodos
9.
Sci Rep ; 14(1): 2601, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297114

RESUMO

This work provides the first experimental proof of an increased neutron capture photon signal following the introduction of boron to a PMMA phantom during helium and carbon ion therapies in Neutron Capture Enhanced Particle Therapy (NCEPT). NCEPT leverages [Formula: see text]B neutron capture, leading to the emission of detectable 478 keV photons. Experiments were performed at the Heavy Ion Medical Accelerator in Chiba, Japan, with two Poly(methyl methacrylate) (PMMA) targets, one bearing a boron insert. The BeNEdiCTE gamma-ray detector measured an increase in the 478 keV signal of 45 ± 7% and 26 ± 2% for carbon and helium ion irradiation, respectively. Our Geant4 Monte Carlo simulation model, developed to investigate photon origins, found less than 30% of detected photons originated from the insert, while boron in the detector's circuit boards contributed over 65%. Further, the model investigated detector sensitivity, establishing its capability to record a 10% increase in 478 keV photon detection at a target [Formula: see text]B concentration of 500 ppm using spectral windowing alone, and 25% when combined with temporal windowing. The linear response extended to concentrations up to 20,000 ppm. The increase in the signal in all evaluated cases confirm the potential of the proposed detector design for neutron capture quantification in NCEPT.

10.
Anthropol Anz ; 81(2): 161-167, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-37642531

RESUMO

With the increasing use of radiological three-dimensional imaging, different metric and morphological aspects of the frontal sinuses (FS) have been examined relative to their potential to aid human identification, including sex estimation. The aim of this study is to assess the validity of the metric analysis of the FS volume for estimating sex in a Western Australian (WA) adult population, following the Michel et al. (2015) method. The right, left and total frontal sinus volume (TFSV) from 99 computed tomography scans (47 males and 52 females) of WA individuals aged 18-40 years were three-dimensionally reconstructed using OsiriX® and their volumes acquired in mm3. Sexual dimorphism in the TFSV was tested, and the accuracy of the Michel et al. (2015) formulae was calculated. Population-specific regression equations were also produced. There was a significant difference between the mean TFSV in males and females. The classification accuracy derived from the Michel et al. (2015) formulae was 59.6%. The WA-specific logistic regression analysis yielded an accuracy of 57.2%. The low accuracy rates preclude the use of the sex estimation method in the WA population, but the volume analysis confirmed the individual variability of the frontal sinuses, which may be useful for personal identification.


Assuntos
Seio Frontal , Determinação do Sexo pelo Esqueleto , Adulto , Masculino , Feminino , Humanos , Seio Frontal/diagnóstico por imagem , Seio Frontal/anatomia & histologia , Determinação do Sexo pelo Esqueleto/métodos , Austrália , Tomografia Computadorizada por Raios X , Antropologia Forense/métodos
11.
Int J Legal Med ; 138(2): 537-545, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37269396

RESUMO

The ability to differentiate individuals based on their biological sex is essential for the creation of an accurate anthropological assessment; it is therefore crucial that the standards that facilitate this are likewise accurate. Given the relative paucity of population-specific anthropological standards formulated specifically for application in the contemporary Australian population, forensic anthropological assessments have historically relied on the application of established methods developed using population geographically and/or temporally disparate. The aim of the present paper is, therefore, to assess the accuracy and reliability of established cranial sex estimation methods, developed from geographically distinct populations, as applied to the contemporary Australian population. Comparison between the original stated accuracy and sex bias values (where applicable) and those achieved after application to the Australian population provides insight into the importance of having anthropological standards optimised for application in specific jurisdictions. The sample analysed comprised computed tomographic (CT) cranial scans of 771 (385 female and 386 male) individuals collected from five Australian states/territories. Cranial CT scans were visualised as three-dimensional volume-rendered reconstructions using OsiriX®. On each cranium, 76 cranial landmarks were acquired, and 36 linear inter-landmark measurements were calculated using MorphDB. A total of 35 predictive models taken from Giles and Elliot (1963), Iscan et al. (1995), Ogawa et al. (2013), Steyn and Iscan (1998) and Kranioti et al. (2008) were tested. Application to the Australian population resulted in an average decrease in accuracy of 21.2%, with an associated sex bias range between - 64.0 and 99.7% (average sex bias value of 29.6%), relative to the original studies. The present investigation has highlighted the inherent inaccuracies of applying models derived from geographically and/or temporally disparate populations. It is, therefore, imperative that statistical models developed from a population consistent with the decedent be used for the estimation of sex in forensic casework.


Assuntos
Tomografia Computadorizada Multidetectores , Determinação do Sexo pelo Esqueleto , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Austrália , Determinação do Sexo pelo Esqueleto/métodos , Análise Discriminante , Antropologia Forense/métodos
12.
Int J Legal Med ; 138(1): 239-247, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37055626

RESUMO

Sex estimation is an integral aspect of a forensic biological profile. The pelvis, being the most dimorphic part of the skeleton, has been studied in considerable detail relative to morphological and metric variation. However, empirical data on the effect of age on pelvic morphology relative to sex-specific morphological variation is limited, especially in regard to the estimation of skeletal sex. This study assesses whether there are age-related differences in the distribution of the Walker (2005) morphological scores for the greater sciatic notch (GSN) in an Australian population. Three-dimensional volumetric reconstructions derived from multi-detector computed tomography (MDCT) scans of 567 pelves of 258 females and 309 males aged 18 to 96 years were scored following Walker (2005). Differences in score distributions and means by sex and age group were tested using Pearson's chi-squared test and ANOVA, respectively. The accuracy of sex estimates derived from logistic regression equations was explored using leave-one-out cross-validation. Significant differences were found in score distribution and means among age groups in females, but not in males. There was a tendency toward higher scores in older females. The overall sex estimation accuracy was 87.5%. When comparing age groups 18-49 and 70 + years, estimation accuracy decreased in females (99% vs. 91%), while the opposite was found for males (79% vs. 87%). These findings suggest that age affects GSN morphology. Higher mean scores in older females imply that, on average, the GSN becomes narrower with increasing age. It is thus recommended due consideration of estimated age when assessing sex based on the GSN in unidentified human remains.


Assuntos
Antropologia Forense , Determinação do Sexo pelo Esqueleto , Masculino , Feminino , Humanos , Idoso , Antropologia Forense/métodos , Austrália , Determinação do Sexo pelo Esqueleto/métodos , Pelve , Tomografia Computadorizada Multidetectores
13.
Nat Biomed Eng ; 7(10): 1229-1241, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37783757

RESUMO

Cardiovascular health is typically monitored by measuring blood pressure. Here we describe a wireless on-skin system consisting of synchronized sensors for chest electrocardiography and peripheral multispectral photoplethysmography for the continuous monitoring of metrics related to vascular resistance, cardiac output and blood-pressure regulation. We used data from the sensors to train a support-vector-machine model for the classification of haemodynamic states (resulting from exposure to heat or cold, physical exercise, breath holding, performing the Valsalva manoeuvre or from vasopressor administration during post-operative hypotension) that independently affect blood pressure, cardiac output and vascular resistance. The model classified the haemodynamic states on the basis of an unseen subset of sensor data for 10 healthy individuals, 20 patients with hypertension undergoing haemodynamic stimuli and 15 patients recovering from cardiac surgery, with an average precision of 0.878 and an overall area under the receiver operating characteristic curve of 0.958. The multinodal sensor system may provide clinically actionable insights into haemodynamic states for use in the management of cardiovascular disease.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Humanos , Hemodinâmica/fisiologia , Pressão Sanguínea/fisiologia , Eletrocardiografia
14.
Sci Rep ; 13(1): 17415, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37833371

RESUMO

In this study, we present a validated Geant4 Monte Carlo simulation model of the Dingo thermal neutron imaging beamline at the Australian Centre for Neutron Scattering. The model, constructed using CAD drawings of the entire beam transport path and shielding structures, is designed to precisely predict the in-beam neutron field at the position at the sample irradiation stage. The model's performance was assessed by comparing simulation results to various experimental measurements, including planar thermal neutron distribution obtained in-beam using gold foil activation and [Formula: see text]B[Formula: see text]C-coated microdosimeters and the out-of-beam neutron spectra measured with Bonner spheres. The simulation results demonstrated that the predicted neutron fluence at the field's centre is within 8.1% and 2.1% of the gold foil and [Formula: see text]B[Formula: see text]C-coated microdosimeter measurements, respectively. The logarithms of the ratios of average simulated to experimental fluences in the thermal (E[Formula: see text] 0.414 eV), epithermal (0.414 eV < E[Formula: see text] 11.7 keV) and fast (E[Formula: see text] 11.7 keV) spectral regions were approximately - 0.03 to + 0.1, - 0.2 to + 0.15, and - 0.4 to + 0.2, respectively. Furthermore, the predicted thermal, epithermal and fast neutron components in-beam at the sample stage position constituted approximately 18%, 64% and 18% of the total neutron fluence.

15.
Physiol Meas ; 44(11)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37494945

RESUMO

Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Monitores de Aptidão Física , Processamento de Sinais Assistido por Computador , Frequência Cardíaca/fisiologia
16.
Sci Adv ; 9(10): eadf7207, 2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36888718

RESUMO

All present commercial colors are based on pigments. While such traditional pigment-based colorants offer a commercial platform for large-volume and angle insensitiveness, they are limited by their instability in atmosphere, color fading, and severe environmental toxicity. Commercial exploitation of artificial structural coloration has fallen short due to the lack of design ideas and impractical nanofabrication techniques. Here, we present a self-assembled subwavelength plasmonic cavity that overcomes these challenges while offering a tailorable platform for rendering angle and polarization-independent vivid structural colors. Fabricated through large-scale techniques, we produce stand-alone paints ready to be used on any substrate. The platform offers full coloration with a single layer of pigment, surface density of 0.4 g/m2, making it the lightest paint in the world.

17.
PLoS One ; 18(3): e0281904, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36920897

RESUMO

Since the 1970s, monumental stone structures now called mustatil have been documented across Saudi Arabia. However, it was not until 2017 that the first intensive and systematic study of this structure type was undertaken, although this study could not determine the precise function of these features. Recent excavations in AlUla have now determined that these structures fulfilled a ritual purpose, with specifically selected elements of both wild and domestic taxa deposited around a betyl. This paper outlines the results of the University of Western Australia's work at site IDIHA-0008222, a 140 m long mustatil (IDIHA-F-0011081), located 55 km east of AlUla. Work at this site sheds new and important light on the cult, herding and 'pilgrimage' in the Late Neolithic of north-west Arabia, with the site revealing one of the earliest chronometrically dated betyls in the Arabian Peninsula and some of the earliest evidence for domestic cattle in northern Arabia.


Assuntos
Comportamento Ritualístico , Animais , Bovinos , Arábia , Arábia Saudita
18.
Comput Methods Programs Biomed ; 233: 107453, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36921463

RESUMO

PURPOSE: Selective internal radiation therapy (SIRT) has been proven to be an effective treatment for hepatocellular carcinoma (HCC) patients. In clinical practice, the treatment planning for SIRT using 90Y microspheres requires estimation of the liver-lung shunt fraction (LSF) to avoid radiation pneumonitis. Currently, the manual segmentation method to draw a region of interest (ROI) of the liver and lung in 2D planar imaging of 99mTc-MAA and 3D SPECT/CT images is inconvenient, time-consuming and observer-dependent. In this study, we propose and evaluate a nearly automatic method for LSF quantification using 3D SPECT/CT images, offering improved performance compared with the current manual segmentation method. METHODS: We retrospectively acquired 3D SPECT with non-contrast-enhanced CT images (nCECT) of 60 HCC patients from a SPECT/CT scanning machine, along with the corresponding diagnostic contrast-enhanced CT images (CECT). Our approach for LSF quantification is to use CNN-based methods for liver and lung segmentations in the nCECT image. We first apply 3D ResUnet to coarsely segment the liver. If the liver segmentation contains a large error, we dilate the coarse liver segmentation into the liver mask as a ROI in the nCECT image. Subsequently, non-rigid registration is applied to deform the liver in the CECT image to fit that obtained in the nCECT image. The final liver segmentation is obtained by segmenting the liver in the deformed CECT image using nnU-Net. In addition, the lung segmentations are obtained using 2D ResUnet. Finally, LSF quantitation is performed based on the number of counts in the SPECT image inside the segmentations. Evaluations and Results: To evaluate the liver segmentation accuracy, we used Dice similarity coefficient (DSC), asymmetric surface distance (ASSD), and max surface distance (MSD) and compared the proposed method to five well-known CNN-based methods for liver segmentation. Furthermore, the LSF error obtained by the proposed method was compared to a state-of-the-art method, modified Deepmedic, and the LSF quantifications obtained by manual segmentation. The results show that the proposed method achieved a DSC score for the liver segmentation that is comparable to other state-of-the-art methods, with an average of 0.93, and the highest consistency in segmentation accuracy, yielding a standard deviation of the DSC score of 0.01. The proposed method also obtains the lowest ASSD and MSD scores on average (2.6 mm and 31.5 mm, respectively). Moreover, for the proposed method, a median LSF error of 0.14% is obtained, which is a statically significant improvement to the state-of-the-art-method (p=0.004), and is much smaller than the median error in LSF manual determination by the medical experts using 2D planar image (1.74% and p<0.001). CONCLUSIONS: A method for LSF quantification using 3D SPECT/CT images based on CNNs and non-rigid registration was proposed, evaluated and compared to state-of-the-art techniques. The proposed method can quantitatively determine the LSF with high accuracy and has the potential to be applied in clinical practice.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Estudos Retrospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Pulmão/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
20.
Phys Med Biol ; 67(19)2022 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-35947996

RESUMO

Objective. We aim to evaluate a method for estimating 1D physical dose deposition profiles in carbon ion therapy via analysis of dynamic PET images using a deep residual learning convolutional neural network (CNN). The method is validated using Monte Carlo simulations of12C ion spread-out Bragg peak (SOBP) profiles, and demonstrated with an experimental PET image.Approach. A set of dose deposition and positron annihilation profiles for monoenergetic12C ion pencil beams in PMMA are first generated using Monte Carlo simulations. From these, a set of random polyenergetic dose and positron annihilation profiles are synthesised and used to train the CNN. Performance is evaluated by generating a second set of simulated12C ion SOBP profiles (one 116 mm SOBP profile and ten 60 mm SOBP profiles), and using the trained neural network to estimate the dose profile deposited by each beam and the position of the distal edge of the SOBP. Next, the same methods are used to evaluate the network using an experimental PET image, obtained after irradiating a PMMA phantom with a12C ion beam at QST's Heavy Ion Medical Accelerator in Chiba facility in Chiba, Japan. The performance of the CNN is compared to that of a recently published iterative technique using the same simulated and experimental12C SOBP profiles.Main results. The CNN estimated the simulated dose profiles with a mean relative error (MRE) of 0.7% ± 1.0% and the distal edge position with an accuracy of 0.1 mm ± 0.2 mm, and estimate the dose delivered by the experimental12C ion beam with a MRE of 3.7%, and the distal edge with an accuracy of 1.7 mm.Significance. The CNN was able to produce estimates of the dose distribution with comparable or improved accuracy and computational efficiency compared to the iterative method and other similar PET-based direct dose quantification techniques.


Assuntos
Radioterapia com Íons Pesados , Polimetil Metacrilato , Carbono/uso terapêutico , Radioterapia com Íons Pesados/métodos , Método de Monte Carlo , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA