Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Meat Sci ; 200: 109139, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36933497

RESUMO

Eight treatments of edible coatings and nets including liquid smoke (SP and 24P) and xanthan gum (XG) were used to evaluate their effectiveness at controlling mite growth on dry-cured hams. Mite growth was controlled (P < 0.05) in both coating and netting treatments of 1% SP + 1% XG. Increasing SP concentration from 1% to 2% in the SP only treatments without XG did not control mite growth (P > 0.05) in the coating but controlled mite growth (P < 0.05) when infused in the nets. Both coating and netting treatments with 2% 24P + 1% XG controlled mite growth (P < 0.05), and ham cubes with 1% and 2% 24P in infused nets had mite numbers of 4.6 and 9.4, respectively. SP did not impact the sensory attributes of the ham. Results indicate that liquid smoke can potentially be added in coatings or ham nets to control mites and used in an integrated pest management program for dry-cured hams.


Assuntos
Ácaros , Carne de Porco , Animais , Fumaça , Controle de Pragas/métodos , Envelhecimento
2.
Wearable Technol ; 4: e4, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38487777

RESUMO

The development of wearable technology, which enables motion tracking analysis for human movement outside the laboratory, can improve awareness of personal health and performance. This study used a wearable smart sock prototype to track foot-ankle kinematics during gait movement. Multivariable linear regression and two deep learning models, including long short-term memory (LSTM) and convolutional neural networks, were trained to estimate the joint angles in sagittal and frontal planes measured by an optical motion capture system. Participant-specific models were established for ten healthy subjects walking on a treadmill. The prototype was tested at various walking speeds to assess its ability to track movements for multiple speeds and generalize models for estimating joint angles in sagittal and frontal planes. LSTM outperformed other models with lower mean absolute error (MAE), lower root mean squared error, and higher R-squared values. The average MAE score was less than 1.138° and 0.939° in sagittal and frontal planes, respectively, when training models for each speed and 2.15° and 1.14° when trained and evaluated for all speeds. These results indicate wearable smart socks to generalize foot-ankle kinematics over various walking speeds with relatively low error and could consequently be used to measure gait parameters without the need for a lab-constricted motion capture system.

3.
Healthcare (Basel) ; 10(7)2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35885797

RESUMO

Compression socks are used by a very diverse group of individuals and may potentially have a greater impact on physically diminished or impaired individuals as opposed to healthy individuals. The purpose of this study was to compare the effects of sub-clinical (SC) and clinical (CL) compression socks among healthy (CON), copers (COP), and individuals with chronic ankle instability (CAI). Postural stability was evaluated in 20 participants (11 males and 9 females) using Balance Tracking System Balance platform (BTrackS™) during the modified clinical test of sensory integration in balance (mCTSIB) and limits of stability (LOS) tests. Postural sway parameters were analyzed using a mixed model repeated measures analysis of variance 3 (group: CON, COP, and CAI) by 3 (compression condition: BF, SC, and CL) × 4 (balance condition: EO, EC, EOF, and ECF) for mCTSIB and a 3 (group: CON, COP, and CAI) by 3 (compression condition: BF, SC, CL) × 4 (balance condition: FL, BL, BR, FR) for LOS. Results revealed significantly greater postural stability with both SC and CL compression socks when compared to barefoot conditions. However, no significant differences were observed among groups for compression socks grades. Both SC and CL compression socks may be effective in increasing postural stability.

4.
Artigo em Inglês | MEDLINE | ID: mdl-35681957

RESUMO

The purpose of this study is to compare masks (non-medical/fabric, surgical, and N95 respirators) on filtration efficiency, differential pressure, and leakage with the goal of providing evidence to improve public health messaging. Masks were tested on an anthropometric face filtration mount, comparing both sealed and unsealed. Overall, surgical and N95 respirators provided significantly higher filtration efficiency (FE) and differential pressure (dP). Leakage comparisons are one of the most significant factors in mask efficiency. Higher weight and thicker fabric masks had significantly higher filtration efficiency. The findings of this study have important implications for communication and education regarding the use of masks to prevent the spread of COVID-19 and other respiratory illnesses, specifically the differences between sealed and unsealed masks. The type and fabric of facial masks and whether a mask is sealed or unsealed has a significant impact on the effectiveness of a mask. Findings related to differences between sealed and unsealed masks are of critical importance for health care workers. If a mask is not completely sealed around the edges of the wearer, FE for this personal protective equipment is misrepresented and may create a false sense of security. These results can inform efforts to educate health care workers and the public on the importance of proper mask fit.


Assuntos
COVID-19 , Dispositivos de Proteção Respiratória , COVID-19/prevenção & controle , Humanos , Máscaras , Equipamento de Proteção Individual , Saúde Pública , Têxteis
5.
Bioengineering (Basel) ; 9(1)2022 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-35049742

RESUMO

Wearable technologies are emerging as a useful tool with many different applications. While these devices are worn on the human body and can capture numerous data types, this literature review focuses specifically on wearable use for performance enhancement and risk assessment in industrial- and sports-related biomechanical applications. Wearable devices such as exoskeletons, inertial measurement units (IMUs), force sensors, and surface electromyography (EMG) were identified as key technologies that can be used to aid health and safety professionals, ergonomists, and human factors practitioners improve user performance and monitor risk. IMU-based solutions were the most used wearable types in both sectors. Industry largely used biomechanical wearables to assess tasks and risks wholistically, which sports often considered the individual components of movement and performance. Availability, cost, and adoption remain common limitation issues across both sports and industrial applications.

6.
Materials (Basel) ; 14(15)2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34361264

RESUMO

Standards for the fatigue testing of wearable sensing technologies are lacking. The majority of published fatigue tests for wearable sensors are performed on proof-of-concept stretch sensors fabricated from a variety of materials. Due to their flexibility and stretchability, polymers are often used in the fabrication of wearable sensors. Other materials, including textiles, carbon nanotubes, graphene, and conductive metals or inks, may be used in conjunction with polymers to fabricate wearable sensors. Depending on the combination of the materials used, the fatigue behaviors of wearable sensors can vary. Additionally, fatigue testing methodologies for the sensors also vary, with most tests focusing only on the low-cycle fatigue (LCF) regime, and few sensors are cycled until failure or runout are achieved. Fatigue life predictions of wearable sensors are also lacking. These issues make direct comparisons of wearable sensors difficult. To facilitate direct comparisons of wearable sensors and to move proof-of-concept sensors from "bench to bedside", fatigue testing standards should be established. Further, both high-cycle fatigue (HCF) and failure data are needed to determine the appropriateness in the use, modification, development, and validation of fatigue life prediction models and to further the understanding of how cracks initiate and propagate in wearable sensing technologies.

7.
Sensors (Basel) ; 21(16)2021 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-34450790

RESUMO

There is scarce research into the use of Strive Sense3 smart compression shorts to measure external load with accelerometry and muscle load (i.e., muscle activations) with surface electromyography in basketball. Sixteen external load and muscle load variables were measured from 15 National Collegiate Athletic Association Division I men's basketball players with 1137 session records. The data were analyzed for player positions of Centers (n = 4), Forwards (n = 4), and Guards (n = 7). Nonparametric bootstrapping was used to find significant differences between training and game sessions. Significant differences were found in all variables except Number of Jumps and all muscle load variables for Guards, and all variables except Muscle Load for Forwards. For Centers, the Average Speed, Average Max Speed, and Total Hamstring, Glute, Left, and Right Muscle variables were significantly different (p < 0.05). Principal component analysis was conducted on the external load variables. Most of the variance was explained within two principal components (70.4% in the worst case). Variable loadings of principal components for each position were similar during training but differed during games, especially for the Forward position. Measuring muscle activation provides additional information in which the demands of each playing position can be differentiated during training and competition.


Assuntos
Desempenho Atlético , Basquetebol , Humanos , Masculino , Músculos , Fenômenos Físicos , Análise de Componente Principal
8.
Artigo em Inglês | MEDLINE | ID: mdl-33924707

RESUMO

Research surrounding the mandated use of non-medical fabric masks is inconsistent and often confusing when compared to the standard N95. A recently published standard from ASTM International and the Centers for Disease Control and Prevention attempts to normalize evaluation procedures. The purpose of this study is to conduct a preliminary evaluation of the new methods for testing filtration efficiency of masks outlined by ASTM International F3502, where results can be directly compared to standards outlined for non-medical fabric masks. Eleven consumer non-medical fabric masks were tested for filtration efficiency and airflow resistance using a face filtration mount in accordance with the newly released ASTM International standard for facial barriers. The mean FE% (SD) ranged from 0.46% (0.44) to 11.80% (2.76) with the 3-layer athletic mesh having the highest performance and the highest deviations. All the masks tested following the procedure failed to meet to minimum FE of 20%; however all masks performed below the minimum upper limits for airflow resistance. Using a non-medical fabric masks as the sole mitigation strategy may not be as effective, as previously reported. With efforts to standardize and regulate the non-medical fabric mask market, this study demonstrates a variety of currently available consumer mask products do not meet the minimum standards nor are these remotely close to the standards of surgical or N95 masks.


Assuntos
Filtração , Têxteis
9.
Stem Cells Transl Med ; 7(3): 271-282, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29473346

RESUMO

Despite advances in ex vivo expansion of cord blood-derived hematopoietic stem/progenitor cells (CB-HSPC), challenges still remain regarding the ability to obtain, from a single unit, sufficient numbers of cells to treat an adolescent or adult patient. We and others have shown that CB-HSPC can be expanded ex vivo in two-dimensional (2D) cultures, but the absolute percentage of the more primitive stem cells decreases with time. During development, the fetal liver is the main site of HSPC expansion. Therefore, here we investigated, in vitro, the outcome of interactions of primitive HSPC with surrogate fetal liver environments. We compared bioengineered liver constructs made from a natural three-dimensional-liver-extracellular-matrix (3D-ECM) seeded with hepatoblasts, fetal liver-derived (LvSt), or bone marrow-derived stromal cells, to their respective 2D culture counterparts. We showed that the inclusion of cellular components within the 3D-ECM scaffolds was necessary for maintenance of HSPC viability in culture, and that irrespective of the microenvironment used, the 3D-ECM structures led to the maintenance of a more primitive subpopulation of HSPC, as determined by flow cytometry and colony forming assays. In addition, we showed that the timing and extent of expansion depends upon the biological component used, with LvSt providing the optimal balance between preservation of primitive CB HSPC and cellular differentiation. Stem Cells Translational Medicine 2018;7:271-282.


Assuntos
Sangue Fetal/metabolismo , Células-Tronco Hematopoéticas/metabolismo , Animais , Técnicas de Cultura de Células/métodos , Proliferação de Células , Células Cultivadas , Furões , Humanos , Células-Tronco , Microambiente Tumoral
10.
J Phys Chem Lett ; 7(9): 1646-52, 2016 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-27019342

RESUMO

The deployment of transformational nonaqueous CO2-capture solvent systems is encumbered by high viscosities even at intermediate uptakes. Using single-molecule CO2 binding organic liquids as a prototypical example, we present key molecular features that control bulk viscosity. Fast CO2-uptake kinetics arise from close proximity of the alcohol and amine sites involved in CO2 binding in a concerted fashion, resulting in a Zwitterion containing both an alkyl-carbonate and a protonated amine. The population of internal hydrogen bonds between the two functional groups determines the solution viscosity. Unlike the ion pair interactions in ionic liquids, these observations are novel and specific to a hydrogen-bonding network that can be controlled by chemically tuning single molecule CO2 capture solvents. We present a molecular design strategy to reduce viscosity by shifting the proton transfer equilibrium toward a neutral acid/amine species, as opposed to the ubiquitously accepted zwitterionic state. The molecular design concepts proposed here are readily extensible to other CO2 capture technologies.

11.
ChemSusChem ; 8(21): 3617-25, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26377774

RESUMO

The kinetics of the absorption of CO2 into two nonaqueous CO2-binding organic liquid (CO2 BOL) solvents were measured at T=35, 45, and 55 °C with a wetted-wall column. Selected CO2 loadings were run with a so-called "first-generation" CO2 BOL, comprising an independent base and alcohol, and a "second-generation" CO2 BOL, in which the base and alcohol were conjoined. Liquid-film mass-transfer coefficient (k'g ) values for both solvents were measured to be comparable to values for monoethanolamine and piperazine aqueous solvents under a comparable driving force, in spite of far higher solution viscosities. An inverse temperature dependence of the k'g value was also observed, which suggests that the physical solubility of CO2 in organic liquids may be making CO2 mass transfer faster than expected. Aspen Plus software was used to model the kinetic data and compare the CO2 absorption behavior of nonaqueous solvents with that of aqueous solvent platforms. This work continues our development of the CO2 BOL solvents. Previous work established the thermodynamic properties related to CO2 capture. The present paper quantitatively studies the kinetics of CO2 capture and develops a rate-based model.


Assuntos
Dióxido de Carbono/isolamento & purificação , Imidazolidinas/química , Modelos Químicos , Solventes/química , Gerenciamento de Resíduos , Absorção Fisico-Química , Dióxido de Carbono/química , Cinética , Solubilidade , Temperatura , Termodinâmica , Viscosidade , Gerenciamento de Resíduos/instrumentação , Gerenciamento de Resíduos/métodos , Água/química , Molhabilidade
12.
Dalton Trans ; 44(30): 13490-7, 2015 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-25970023

RESUMO

Metal-organic frameworks (MOFs) have proved to be very attractive for applications including gas storage, separation, sensing and catalysis. In particular, CO(2) separation from flue gas in post-combustion processes is one of the main focuses of research among the scientific community. One of the major issues that are preventing the successful commercialization of these novel materials is their high affinity towards water that not only compromises gas sorption capacity but also the chemical stability. In this paper, we demonstrate a novel post-synthesis modification approach to modify MOFs towards increasing hydrophobic behaviour and chemical stability against moisture without compromising CO(2) sorption capacity. Our approach consists of incorporating hydrophobic moieties on the external surface of the MOFs via physical adsorption. The rationale behind this concept is to increase the surface hydrophobicity in the porous materials without the need of introducing bulky functionalities inside the pore which compromises the sorption capacity toward other gases. We herein report preliminary results on routinely studied MOF materials [MIL-101(Cr) and NiDOBDC] demonstrating that the polymer-modified MOFs retain CO(2) sorption capacity while reducing the water adsorption up to three times, with respect to the un-modified materials, via an equilibrium effect. Furthermore, the water stability of the polymer-functionalized MOFs is significantly higher than the water stability of the bare material. Molecular dynamic simulations demonstrated that this equilibrium effect implies a fundamental and permanent change in the water sorption capacity of MOFs. This approach can also be employed to render moisture stability and selectivity to MOFs that find applications in gas separations, catalysis and sensing where water plays a critical role in compromising MOF performance and recyclability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA