Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Braz Dent J ; 35: e245611, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537014

RESUMO

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/métodos , Ultrassom , Irrigantes do Canal Radicular , Irrigação Terapêutica/métodos , Microtomografia por Raio-X , Dentina
2.
Braz Oral Res ; 38: e006, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198306

RESUMO

The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.


Assuntos
Cavidade Pulpar , Ouro , Microtomografia por Raio-X , Cavidade Pulpar/diagnóstico por imagem , Análise de Variância , Dente Molar/diagnóstico por imagem
3.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1550086

RESUMO

Abstract This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Resumo Este estudo avaliou a correlação entre a curvatura do canal radicular e os efeitos da irrigação ultrassônica nos seguintes parâmetros: volume de remoção não controlada de dentina (UDRVol), profundidade máxima do desgaste de dentina, remoção de debris de tecido duro acumulado (AHTD) e transporte em canais radiculares curvos. Vinte e quatro molares inferiores humanos permanentes foram divididos em dois grupos de acordo com a curvatura do canal radicular: curvatura moderada (MC: média de 25°); e curvatura acentuada (SC: média de 48°). Os espécimes foram digitalizados usando um scanner microcomputador de raios X (Skyscan 1172) antes e depois da limpeza e modelagem e após a irrigação ultrassônica. Houve uma correlação moderada entre o grau de curvatura do canal radicular e o volume de AHTD remanescente (p<0,05) e entre o grau de curvatura do canal radicular e a profundidade máxima de defeitos devido à remoção descontrolada de dentina (p<0,05). Os dentes do grupo SC apresentaram maior profundidade máxima de defeitos na parede dentinária no terço apical do que os dentes do grupo MC (p<0,05). Ambos os grupos tiveram uma redução significativa de AHTD em todos os terços do canal, mas a quantidade de AHTD remanescente nos terços médio e apical e em todo o canal foi significativamente maior no grupo SC do que no grupo MC (p <0,05). O transporte do canal não foi influenciado pela curvatura do canal em todos os terços (p > 0,05). Este estudo concluiu que a curvatura do canal radicular afeta significativamente a remoção descontrolada de dentina e o volume remanescente de AHTD após a irrigação ultrassônica.

4.
Braz. oral res. (Online) ; 38: e006, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1528151

RESUMO

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

5.
Iran Endod J ; 18(2): 71-84, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37152852

RESUMO

Introduction: The nonsurgical endodontic retreatment (NERT) is the first choice of dental ministration when primary/initial endodontic treatment fails. The present study aimed to investigate the presence of postoperative pain (POP) after NERT in permanent asymptomatic teeth as well as possible factors associated with POP. Materials and Methods: A comprehensive search of literature was performed in Pubmed/MEDLINE, Embase, Scopus and Web of Science databases, up to January 2023; including randomized clinical trials and prospective studies. The risk of bias was assessed with RoB 2.0 and ROBINS-I tools. Subgroups analyses were conducted to evaluate the differences in the incidence or level of POP between the number of visits, the use/not use of solvent, the removal technique of gutta-percha, and the period of POP analysis. Mean differences and confidence intervals (CI) of 95% were used as measures of effect, and meta-regression was used along with subgroup analysis. The certainty of evidence was assessed using GRADE, and the probability value of <0.05 was considered significant. Results: Twenty-four studies were selected, with thirteen included in the meta-analysis. There was a statistical difference between the incidence of POP after 24 h (95% CI, 0.28 to 0.52) and one week (95% CI, 0.02 to 0.13) from the endodontic retreatment (P<0.01). However, there was no statistical difference between different techniques, number of visits and use of solvent (P>0.05) in the same period. In addition, the certainty of evidence was very low. Conclusions: Post-operative pain is a common response to NERT, independent of the retreatment technique(s) applied, number of visits and use of solvent(s); with very low certainty of evidence as well as low risk of bias. Moreover, the current analysis showed a (very) serious risk of inconsistency and imprecision. However, POP was significantly reduced within 1 week of the NERT.

6.
Braz. dent. j ; 32(6): 8-15, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1355844

RESUMO

Abstract The aim of this study was to evaluate surface wear, presence of microcracks and surface irregularities of WaveOne (WO) and WaveOne Gold (WOG) instruments before and after multiple uses. Eight Primary instruments of the WO and WOG systems were evaluated, each one was used to prepare six mesial canals of extracted human mandibular molars. The surface of the instruments was evaluated before use (T0), after instrumentation of three (T1) and six (T2) root canals. Surface wear was analyzed using a three-dimensional optical profiler and the presence of microcracks and surface irregularities were evaluated using a tabletop scanning electron microscopy. The Friedman test was used to assess surface wear and Kruskal-Wallis test to evaluate the presence of microcracks and surface irregularities, with a 5% significance level. There was a significant increase in wear in both groups at T2, compared to T0 (p=0.0003). The surface wear after instrumentation of six canals (T2-T0) was statistically greater in the WOG group, than in the WO group (p=0.02), where the presence of microcracks was significantly greater and increased after multiple uses (p<0.05). The presence of surface irregularities in the cutting blade before and after use was statistically greater in the WOG group than WO group (p<0.05). Wear of the cutting blade, microcracks and surface irregularities were observed on the surface topography of all the instruments after multiple uses. These surface changes may affect the cutting efficiency of WOG files and increase the risk of fracture of WO files.


Resumo O objetivo deste estudo foi avaliar o desgaste de superfície, a presença de microtrincas e irregularidades superficiais dos instrumentos WaveOne (WO) e WaveOne Gold (WOG) antes e após múltiplos usos. Oito instrumentos Primary dos sistemas WO e WOG foram avaliados, cada um utilizado no preparo de seis canais mesiais de molares inferiores humanos extraídos. A superfície dos instrumentos foi avaliada antes do uso (T0), após a instrumentação de três (T1) e seis (T2) canais radiculares. O desgaste de superfície foi analisado utilizando um perfilômetro ótico tridimensional e a presença de microtrincas e irregularidades superficiais foram avaliadas usando um microscópio eletrônico de varredura de bancada. O teste de Friedman foi usado para avaliar o desgaste de superfície e o teste de Kruskal-Wallis para avaliar a presença de microtrincas e irregularidades superficiais, com nível de significância de 5%. Houve um aumento significativo no desgaste em ambos os grupos em T2, comparado a T0 (p=0.0003). O desgaste de superfície após a instrumentação de seis canais (T2-T0) foi estatisticamente maior no grupo WOG que no grupo WO (p=0.02), onde a presença de microtrincas foi estatisticamente maior e aumentou após os múltiplos usos (p<0.05). A presença de irregularidades na superfície da lamina de corte antes e após o uso aumento significativamente no grupo WOG comparado ao grupo WO (p<0.05). Desgaste da lâmina de corte, microtrincas e irregularidades superficiais foram observadas na topografia de superfície de todos os instrumentos após os múltiplos usos. Essas alterações na superfície podem afetar a eficiência de corte dos instrumentos WOG e amentar o risco de fratura dos instrumentos WO.

7.
Aust Endod J ; 47(3): 624-630, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34097325

RESUMO

This study evaluated the shaping ability of XP-endo Shaper and Mtwo systems in long-oval-shaped canals of extracted human mandibular molars using micro-computed tomography (micro-CT). Images recorded before and after preparation were evaluated for morphometric measures regarding increase in canal volume, dentin removed, surface area, untouched walls and structure model index (SMI). Data were statistically analysed using the Mann-Whitney test with 5% of significance. On both groups, the root canal preparation significantly increased all analysed parameters (P > 0.05). There was no statistical difference between XP-endo Shaper and Mtwo systems in the increase of the canal volume (30.50%-27.82%), in volume of dentin removed (2.77%-2.40%), in the increase of the canal surface area (11.30%-8.86%), in canal untouched surfaces (9.57%-8.51%) and in the SMI (2.59%-2.68%), respectively. XP-endo Shaper and Mtwo systems showed similar shaping efficiency and were not able to completely prepare the walls of long-oval-shaped canals of extracted human mandibular molars.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Humanos , Dente Molar/diagnóstico por imagem , Microtomografia por Raio-X
8.
Braz Dent J ; 32(6): 8-15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35019022

RESUMO

The aim of this study was to evaluate surface wear, presence of microcracks and surface irregularities of WaveOne (WO) and WaveOne Gold (WOG) instruments before and after multiple uses. Eight Primary instruments of the WO and WOG systems were evaluated, each one was used to prepare six mesial canals of extracted human mandibular molars. The surface of the instruments was evaluated before use (T0), after instrumentation of three (T1) and six (T2) root canals. Surface wear was analyzed using a three-dimensional optical profiler and the presence of microcracks and surface irregularities were evaluated using a tabletop scanning electron microscopy. The Friedman test was used to assess surface wear and Kruskal-Wallis test to evaluate the presence of microcracks and surface irregularities, with a 5% significance level. There was a significant increase in wear in both groups at T2, compared to T0 (p=0.0003). The surface wear after instrumentation of six canals (T2-T0) was statistically greater in the WOG group, than in the WO group (p=0.02), where the presence of microcracks was significantly greater and increased after multiple uses (p<0.05). The presence of surface irregularities in the cutting blade before and after use was statistically greater in the WOG group than WO group (p<0.05). Wear of the cutting blade, microcracks and surface irregularities were observed on the surface topography of all the instruments after multiple uses. These surface changes may affect the cutting efficiency of WOG files and increase the risk of fracture of WO files.


Assuntos
Níquel , Preparo de Canal Radicular , Instrumentos Odontológicos , Cavidade Pulpar , Desenho de Equipamento , Temperatura Alta , Humanos , Titânio
9.
Dent. press endod ; 10(3): 49-55, Sept-Dec.2020. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1344785

RESUMO

Objetivo: O presente estudo usou micro-CT para avaliar a quantidade de material obturador remanescente em canais radiculares curvos que tinham sido obturados com cimento Endosequence BC/Cpoint ou com cimento AH/ guta-percha, depois do retratamento utilizando instrumentos rotatórios ou reciprocantes. Métodos: Sessenta canais mesiovestibulares de molares superiores foram instrumentados até MTwo #35.04. As amostras foram randomicamente alocadas em quatro grupos (n=15): os canais do G1 e G2 foram obturados com AH/guta-percha, e os canais do G3 e G4 foram obturados com BC/Cpoint. O material obturador foi removido usando instrumentos rotatórios ou reciprocantes ­ G1 e G3: R25 Reciproc + reinstrumentação com R40; e G2 e G4: Sistema ProTaper Universal Retratamento + reinstrumentação com MTwo 40.06. Micro-CTs foram usadas para medir a quantidade de material obturador remanescente (mm3 ) para o canal inteiro e para cada terço, em dois momentos: 1) após a remoção do material obturador; e 2) após a reinstrumentação. Resultados: Após a remoção do material obturador, BC/CPoint permaneceu mais dentro do canal do que AH/guta-percha quando o canal inteiro (29,92% x 19,25%, p=0,0290) e o terço apical foram analisados. Após a reinstrumentação, BC/CPoint permaneceu mais do que AH/guta-percha somente no terço apical. Protocolos de tratamento com instrumentos rotatórios ou reciprocantes removeram material obturador sem diferença para AH/guta-percha (G1 e G2: p> 0,05) e BC/CPoint (G3 e G4: p> 0,05). Conclusões: BC/Cpoint é mais difícil de ser removido de canais radiculares curvos do que AH/guta-percha. Instrumentos rotatórios e reciprocantes têm habilidade similar na remoção de material obturador (AU).


Objective: This study used micro-CT to evaluate the amount of remaining filling material in curved root canals obturated with Endosequence BC Sealer/Cpoint or AH/gutta-percha after a rotary or reciprocating retreatment. Methods: Sixty mesiobuccal canals of maxillary molars were instrumented up to MTwo #35.04. Samples were randomly assigned to four groups (n=15): canals from G1 and G2 were filled with AH/gutta-percha, and canals from G3 and G4 were filled with BC/Cpoint. Filling material was removed using rotary or reciprocating instruments: G1 and G3: R25 Reciproc + re-shaping with R40; and G2 and G4: ProTaper Universal Retreatment system + re-shaping with MTwo 40.06. Micro-CT was used to measure the remaining amount of filling material (mm3 ), for the whole canal, and for each third, in two moments: 1) after filling removal and 2) after canal re-shaping. Results: After filling removal, BC/CPoint remained more into the canal than AH/Gutta-percha when the whole canal (29.92% x 19.25%, p = 0.0290) and the apical third were analyzed. After re-shaping, BC/CPoint remained more than AH/Gutta-percha only in the apical third. Rotary or reciprocating retreatment protocols removed filling material without difference for AH/gutta-percha (G1 and G2: p > 0.05) and BC/CPoint (G3 and G4: p > 0.05). Conclusion: BC/Cpoint is more difficult to be removed from curved root canals than AH/gutta-percha. Reciprocating and rotary instruments have similar ability to remove filling material (AU).


Assuntos
Materiais Restauradores do Canal Radicular , Biofilmes , Instrumentos Odontológicos , Microtomografia por Raio-X , Remoção , Retratamento , Guta-Percha , Dente Molar
10.
J Endod ; 46(9): 1309-1316, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32565335

RESUMO

INTRODUCTION: The aim of this study was to compare, using micro-computed tomographic imaging, the preparation of mesial canals of mandibular molars with the Reciproc (VDW GmbH, Munich, Germany) and XP-endo Shaper (FKG, La Chaux-de-Fonds, Switzerland) systems, evaluating changes in dentin and canal volume, the percentage of untouched walls, the volume of accumulated hard tissue debris, and root canal deviation in the apical third. METHODS: Twenty-four mandibular molars with 2 mesial root canals and a single foramen were anatomically paired and divided into 2 experimental groups (n = 12) according to the system used. The specimens were scanned before and after preparation with the SkyScan 1176 microtomographic scanner (Bruker-microCT, Kontich, Belgium) at a resolution of 17.42 µm. The resulting data were statistically compared at a significance level of 5% using the Student t test and the Mann-Whitney test. RESULTS: A significant difference was observed in the untouched surface area for the total canal and the cervical and middle thirds, with the lowest untouched surface area in the XP-endo Shaper group (P < .05). The volume of accumulated hard tissue debris was significantly higher in the Reciproc group in the total canal as well as in the middle and apical thirds. There was no significant difference between the groups regarding the volume of dentin removed or the increase in canal volume and surface area (P > .05). CONCLUSIONS: The XP-endo Shaper touched more walls and left less accumulated hard tissue debris in the root canal system than the Reciproc group. Although the XP-endo Shaper showed superior results, neither system was able to fully prepare the root canal.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Bélgica , Fenômenos Biomecânicos , Humanos , Microtomografia por Raio-X
11.
Braz Oral Res ; 32(suppl 1): e67, 2018 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-30365608

RESUMO

The introduction of automated instrumentation in endodontics represented a major advance in progress for this specialty, with improvements in the quality and predictability of root canal preparation and a significant reduction in procedural errors. In recent years, endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments. In addition, new movements have also been incorporated to offer greater safety and efficiency, optimizing the properties of the NiTi alloy, especially through eccentric rotary motion. An understanding of the mechanical properties of these new NiTi instruments and their effect on the clinical performance of root canal preparation is essential if dental practitioners are to select the instruments that provide optimal clinical outcomes, especially in curved or flattened canals. The objective of this literature review is to present and discuss the characteristics of the NiTi alloys used in the major instrumentation systems available in the market, as well as the influence of the metallurgical and mechanical properties of NiTi instruments and the movements that drive them, to enable more accurate and predictable planning of root canal preparation.


Assuntos
Ligas/química , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Ligas Dentárias/química , Instrumentos Odontológicos , Humanos , Preparo de Canal Radicular/métodos , Propriedades de Superfície
12.
J Endod ; 43(12): 2102-2107, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29033087

RESUMO

INTRODUCTION: The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. METHODS: Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. RESULTS: The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). CONCLUSION: None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation.


Assuntos
Instrumentos Odontológicos/efeitos adversos , Dentina/diagnóstico por imagem , Dentina/patologia , Preparo de Canal Radicular/instrumentação , Microtomografia por Raio-X , Dentina/lesões , Humanos
13.
J Endod ; 43(4): 638-642, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28215345

RESUMO

INTRODUCTION: The objective of this study was to assess the presence of voids in mesial root canals of mandibular molar teeth obturated by using the single-cone (SC) and continuous wave of condensation (CWC) obturation techniques, and results were analyzed by using micro-computed tomography. METHODS: Twenty-four mandibular molars with fully developed roots and mesial root curvature ranging from 25° to 35° were instrumented by using Reciproc R25 files, and then they were obturated by using the SC and CWC techniques. Specimens were scanned before and after obturation for micro-computed tomography analysis (voxel size, 17.42 µm). After volumetric analysis and tridimensional reconstruction of the root canals, data were analyzed by using analysis of variance and the Tukey test. RESULTS: No significant differences were observed between the 2 techniques in terms of total percentage volume of voids: CWC = 3.91% ± 0.72%; SC = 6.52% ± 1.16% (P > .05). Only in the cervical third, CWC showed a significantly lower percentage of voids when compared with SC, namely 2.86% ± 0.94% vs 8.00% ± 1.86%, respectively (P < .05). CONCLUSIONS: The percentage volume of voids was similar in the 2 groups and was influenced by the obturation technique only in the cervical third.


Assuntos
Obturação do Canal Radicular/métodos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/cirurgia , Humanos , Mandíbula , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Radiografia Dentária/métodos , Obturação do Canal Radicular/efeitos adversos , Microtomografia por Raio-X/métodos
14.
Braz. dent. j ; 27(3): 325-331, May-June 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-782829

RESUMO

Abstract This study evaluated pH and release of calcium, sodium and phosphate ions from different medications in human dentin. Fifty premolars were prepared and randomly divided into groups: (CHX) - 2% chlorhexidine gel; (CHX + CH) - CHX + calcium hydroxide PA; (CH) - CH + propylene glycol 600; (NPBG) - experimental niobium phosphate bioactive glass + distilled water; (BG) - bioactive glass (Bio-Gran) + distilled water. The specimens were immersed in deionized water and the pH variations were measured. The quantification of ions in the solutions was made by inductively coupled plasma - atomic emission spectroscopy (ICP/AES) at 10 min, 24 h, 7, 14, 21 and 30 days. The results were analyzed by ANOVA and Tukey`s test, with a significance level of 5%. CH had the highest level of calcium ions release at 30 days, while CHX and BG released more sodium ions. BG, NPBG and CHX released a higher amount of phosphate ions. The pH of CH was significantly higher compared with the other groups. CH favored the greatest increase of pH and calcium ions release. The bioactive glasses released more sodium and phosphate ions and presented an alkaline pH immediately and after 30 days.


Resumo Este estudo avaliou o pH e a liberação de íons cálcio, sódio e fosfato de diferentes medicamentos em dentina humana. Cinquenta pré-molares foram preparados e divididos aleatoriamente em grupos: (CHX) - clorexidina gel 2%; (CHX + CH) - CHX + hidróxido de cálcio PA; (CH) - CH + propilenoglicol 600; (NPBG) - vidro experimental nióbio fosfato bioativo + água destilada; (BG) - vidro bioativo (Bio-Gran) + água destilada. Os espécimes foram submersos em água deionizada e as variações de pH foram mensuradas. A quantificação dos íons nas soluções foi feita por espectrometria de emissão atômica com plasma indutivamente acoplado (ICP - AES) nos tempos de 10 min, 24 h, 7, 14, 21 e 30 dias. Os resultados foram analisados por ANOVA e teste Tukey, com um nível de significância de 5%. Verificou-se que CH a teve a maior liberação íons de cálcio ao final de 30 dias, enquanto CHX e BG liberaram mais íons de sódio. BG, NPBG e CHX apresentaram a maior liberação de íons fosfato. O pH de CH foi significativamente maior em comparação com os outros grupos testados. O grupo CH aumentou o pH e a liberação de íons cálcio. Os vidros bioativos obtiveram uma maior liberação de íons sódio e fosfato e apresentaram pH alcalino imediato e ao final de 30 dias.


Assuntos
Humanos , Hidróxido de Cálcio/química , Cálcio/metabolismo , Clorexidina/química , Vidro , Concentração de Íons de Hidrogênio , Tratamento do Canal Radicular , Microscopia Eletrônica de Varredura
15.
Braz Dent J ; 27(3): 325-31, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27224568

RESUMO

This study evaluated pH and release of calcium, sodium and phosphate ions from different medications in human dentin. Fifty premolars were prepared and randomly divided into groups: (CHX) - 2% chlorhexidine gel; (CHX + CH) - CHX + calcium hydroxide PA; (CH) - CH + propylene glycol 600; (NPBG) - experimental niobium phosphate bioactive glass + distilled water; (BG) - bioactive glass (Bio-Gran) + distilled water. The specimens were immersed in deionized water and the pH variations were measured. The quantification of ions in the solutions was made by inductively coupled plasma - atomic emission spectroscopy (ICP/AES) at 10 min, 24 h, 7, 14, 21 and 30 days. The results were analyzed by ANOVA and Tukey`s test, with a significance level of 5%. CH had the highest level of calcium ions release at 30 days, while CHX and BG released more sodium ions. BG, NPBG and CHX released a higher amount of phosphate ions. The pH of CH was significantly higher compared with the other groups. CH favored the greatest increase of pH and calcium ions release. The bioactive glasses released more sodium and phosphate ions and presented an alkaline pH immediately and after 30 days.


Assuntos
Hidróxido de Cálcio/química , Cálcio/metabolismo , Clorexidina/química , Vidro , Concentração de Íons de Hidrogênio , Tratamento do Canal Radicular , Humanos , Microscopia Eletrônica de Varredura
16.
J Endod ; 42(3): 496-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26776939

RESUMO

INTRODUCTION: Cleaning and shaping without making procedural errors have always been a challenge in endodontics, particularly when the root canals are curved. Several rotary instruments have been developed to minimize such errors. The purpose of this study was to compare the shaping ability of 2 rotary file systems, BioRace (BR; FKG, La Chaux-de-Fonds, Switzerland) and ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), during the preparation of curved root canals in extracted teeth using micro-computed tomographic imaging. METHODS: A total of 20 first and second human mandibular molars with 2 separate mesial canals were scanned before and after root canal preparations using the SkyScan 1176 X-ray microtomograph (Bruker microCT, Kontich, Belgium) at a resolution of 17.42 µm. Canals were prepared using the BR and PTN systems. The percentage of dentin removed after preparation, root canal volume increase, untreated canal walls, structure model index, degree of canal transportation, and centering ability were also measured. RESULTS: There were no significant differences between the 2 groups in the removed dentin after preparation and determination of the root canal volume, percentage of untreated canal walls, structure model index, degree of canal transportation, and centering ability (P > .05). CONCLUSIONS: In conclusion, within the limitations of this ex vivo study, instrumentation of moderately curved mesial roots with 2 independent root canals and foramina using the BR and PTN rotary file systems were equally effective. Both instrumentation systems caused negligible procedural errors with minimal apical transportation.


Assuntos
Ligas/química , Ligas Dentárias/química , Preparo de Canal Radicular/instrumentação , Tratamento do Canal Radicular/instrumentação , Microtomografia por Raio-X/métodos , Cavidade Pulpar/anatomia & histologia , Dentina/anatomia & histologia , Desenho de Equipamento , Humanos , Tratamento do Canal Radicular/métodos , Raiz Dentária
17.
ScientificWorldJournal ; 2015: 686259, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26347249

RESUMO

OBJECTIVES: To evaluate the influence of dentine on the pH of different medications in standardized simulated canals. MATERIALS AND METHODS: Forty resin blocks were divided into groups with and without dentine powder, as follows: 2% chlorhexidine gel; 2% chlorhexidine gel associated with calcium hydroxide PA; calcium hydroxide PA delivered in propylene glycol 600; and NPG delivered in distilled water. The dentine powder was obtained from the root dentine of bovine teeth and added to the medications. The simulated canals were placed in containers with 1.5 mL of deionized water and pH was monitored in multiple intervals, up to 30 days. The mean pH values were calculated and submitted to statistical analysis using paired Student's t-test and ANOVA complemented by the Tukey test (p < 0.05). RESULTS: There was no statistical difference between the groups with and without dentine powder (p > 0.05). The pH values of calcium hydroxide were significantly higher than those of NPG in the first 24 hours (p < 0.05). After 7 days, both behaved in a similar manner. CONCLUSION: The addition of dentine powder to the medications evaluated did not alter the pH of the external solution in any of the time points tested.


Assuntos
Hidróxido de Cálcio/química , Clorexidina/química , Dentina/química , Vidro/química , Propilenoglicol/química , Irrigantes do Canal Radicular/química , Animais , Bovinos , Cavidade Pulpar/cirurgia , Géis , Concentração de Íons de Hidrogênio , Incisivo/cirurgia , Modelos Anatômicos , Nióbio/química , Preparo de Canal Radicular/métodos
18.
J Endod ; 41(10): 1660-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26093470

RESUMO

INTRODUCTION: The aim of this study was to compare the efficacy of passive ultrasonic irrigation (PUI) and the EndoVac (EV) System (Discus Dental, Culver City, CA) in hard tissue debris removal and its influence on the quality of the root canal filling with the aid of micro-computed tomographic scanner. METHODS: Twenty-four mandibular molars were subjected to 4 microtomographic scannings (ie, before and after instrumentation, after final irrigation, and after obturation) using the SkyScan 1176 X-ray microtomograph (Bruker microCT, Kontich, Belgium) at a resolution of 17.42 µm. Mesial canals were prepared using R25 Reciproc instruments (VDW GmbH, Munich, Germany) and divided into 2 groups according to the final irrigation method: the PUI group (n = 12) and the EV group (n = 12). All specimens were filled with the continuous wave of condensation technique. CTAn and CTvol software (Bruker microCT) were used for volumetric analysis and 3-dimensional model reconstruction of the root canals, hard tissue debris, and the filling material. Data were statistically analyzed using the Student t test. RESULTS: Analysis of the micro-computed tomographic scans revealed debris accumulated inside the root canals, occupying an average of 3.4% of the canal's volume. Irrigation with PUI and the EV system reduced the volume of hard tissue debris in 55.55% and 53.65%, respectively, with no statistical difference between them (P > .05). Also, there was no difference among the groups with regard to the volume of filling material and voids (P > .05). CONCLUSIONS: PUI and the EV system were equally efficient in the removal of hard tissue debris and the quality of root canal filling was similar in both groups, with no influence from the irrigation method.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Irrigantes do Canal Radicular/administração & dosagem , Preparo de Canal Radicular/métodos , Camada de Esfregaço , Irrigação Terapêutica/métodos , Microtomografia por Raio-X , Humanos , Mandíbula , Dente Molar/diagnóstico por imagem , Ultrassom
19.
J Endod ; 40(5): 717-20, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24767570

RESUMO

INTRODUCTION: More information regarding the ability of single files to maintain the original canal position is required before adopting a single-file approach to cleaning and shaping. This study compares apical transportation in curved root canals when instrumenting with a single WaveOne (WO) file (Dentsply Tulsa Dental Specialties, Tulsa, OK) in a reciprocating motion with that incurred when using a sequence of Twisted Files (TFs; SybronEndo, Orange, CA) in a continuous rotating motion. METHODS: Forty mesial canals of mandibular molars were evenly allocated into 2 balanced groups (n = 20) with a 17-mm average canal length and 20° average curvature. Canals were accessed in a conventional manner and instrumentation was completed with a single WO file or a series of TFs. The canals were instrumented according to the manufacturers' protocol. Apical transportation was assessed on a comparison of the pre- and postinstrumentation micro-computed tomographic scans at 1-, 2-, 3-, 4-, and 5-mm sections. One-way analysis of variance was performed to assess if a significant difference between systems exists. RESULTS: No significant difference (P > .05) was found between the WO and TF groups. Transportation in the mesial direction was of greater magnitude than distal transportation for both files systems. The mean transportation in the mesial direction was 100.1 ± 8.8 µm (WO group) and 101.0 ± 10.9 µm (TF group) (P = .5), whereas distal transportation was found to be 80.9 ± 14.6 µm (WO group) and 60.3 ± 11.0 µm (TF group) (P = .3). CONCLUSIONS: The results suggest that no difference exists between the WO file system and the conventional multifile TF system when considering apical transportation in curved canals.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Preparo de Canal Radicular/instrumentação , Ápice Dentário/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Anatomia Transversal/métodos , Desenho de Equipamento , Humanos , Técnicas In Vitro , Dente Molar/diagnóstico por imagem , Distribuição Aleatória , Irrigantes do Canal Radicular/uso terapêutico , Rotação , Hipoclorito de Sódio/uso terapêutico , Irrigação Terapêutica/métodos
20.
São Paulo; s.n; 2014. 96 p. ilus, tab. (BR).
Tese em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-747285

RESUMO

A instrumentação do canal radicular possui como conseqüência a formação de debris dentinários, os quais acumulam-se especialmente nas áreas mais complexas do sistema de canais radiculares. Por este motivo, atenção especial tem sido concedida aos métodos de agitação da substâ ncia química auxiliar, com o intuito de melhorar a sua eficácia química e mecânica. No entanto, não está claro se debris dentinários removidos do interior do canal radicular possuem efeito na qualidade da obturação. Portanto, os objetivos deste estudo foram, com o auxílio da microtomografia computadorizada (micro-CT): avaliar e quantificar a presença de debris dentinários em canais curvos, após o preparo químico-cirúrgico; comparar a remoção desses debris, após uso de Irrigação Ultrassônica Passiva (IUP) ou do sistema EndoVac; e avaliar a qualidade da obturação dos mesmos canais, mensurando o volume de material obturador e de espaços vazios. Vinte e quatro raízes mesiais de molares inferiores humanos extraídos foram divididos aleatoriamente em 2 grupos (n=12), de acordo com o método de irrigação final a ser avaliado. Cada espécime foi submetido a quatro escaneamentos: exame préoperatório, exame pós-preparo, exame pós-irrigação final e exame pós-obturação, com um microtomógrafo de raios-X SkyScan 1176, a uma resolução de 17,42 m. Após preparo químico-cirúrgico os grupos receberam irrigação final com IUP ou com o sistema EndoVac e em seguida obturados com a técnica termoplástica de ondas contínuas de condensação. Após a reconstrução das imagens resultantes dos quatro escaneamentos, o corregistro das mesmas foi realizado com o programa DataViewer. Os programas CTAn e CTvol foram utilizados para binarização dos objetos de interesse, análise volumétrica e reconstrução de modelos 3D do canal radicular, dos debris dentinários e do material obturador. Os dados foram analisados estatisticamente com o programa GraphPad Prism por meio do teste t de Student (p < 0,05). As análises de micro-CT revelaram debris dentinários acumulados no interior dos canais radiculares, ocupando uma porcentagem média em relação ao volume do canal de 2,71% para o grupo IUP e 4,10% para o grupo EndoVac. Não houve diferença entre os grupos quanto à remoção de debris dentinários, nem em relação ao volume de material obturador e de espaços vazios (p > 0,05). Concluiu-se que a IUP e o sistema EndoVac foram igualmente eficientes na remoção de debris dentinários, reduzindo em média 50% do seu volume. Também, a ativação dos irrigantes pelos dois métodos não interferiu na qualidade da obturação do canal radicular.


Root canal preparation has as a consequence the formation of hard-tissue debris, which accumulates specially in the complex areas of the root canal system. For this reason, special attention has been given to methods of agitation of the irrigants, aiming to improve its chemical and mechanical efficiency. However, it is not clear if dentin debris removed from the root canal have impact on the quality of root canal filling. Therefore, the objectives of this study were, with the aid of microcomputed tomography (micro-CT): evaluate and quantify the presence of hard-tissue debris in curved root canals, after chemical-surgical preparation; compare the removal of such debris after final irrigation with Passive Ultrasonic Irrigation (PUI) or with the EndoVac system; and evaluate the quality of filling of the same root canals, measuring the volume of filling material and voids. Twenty-four mesial roots of extracted mandibular human molars were randomly divided into 2 groups (n = 12) according to the method of final irrigation being evaluated. Each specimen was subjected to four scans: preoperative, post-operative, post-final irrigation and post-filling, with a microcomputed tomography SkyScan 1176, at a resolution of 17,42 m. After chemosurgical preparation groups received final irrigation with Passive Ultrasonic Irrigation (PUI) or with EndoVac system and were then filled with the continuous wave condensation thermoplastic technique. After the reconstruction of the images resulted from the four scans, co-registration was performed with the DataViewer software. CTAn and CTvol softwares were used for binarization of the objects of interest, volumetric analysis and reconstruction of 3D models of the root canal, hardtissue debris and the filling material. Data were statistically analyzed with the GraphPad Prism program through t students test (p < 0,05). The analysis of micro- CT showed hard-tissue debris accumulated inside the root canal, occupying an average percentage of 2.71 % for the PUI group and 4.10 % for EndoVac group. There was no difference between the groups regarding the removal of hard-tissue debris, or in relation to the volume of filling material and voids (p > 0.05). It was concluded that the EndoVac and PUI were equally efficient in the removal of hardtissue debris, reducing an average of 50% of its volume. Also, irrigants activation with the two methods did not affect the quality of root canal filling.


Assuntos
Humanos , Masculino , Feminino , Irrigantes do Canal Radicular/uso terapêutico , Microtomografia por Raio-X , Obturação do Canal Radicular/métodos , Tratamento do Canal Radicular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA