Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38805071

RESUMO

The electroretinogram (ERG), a non-invasive electrophysiological tool used in ophthalmology, is increasingly applied to investigate neural correlates of depression. The present study aimed to reconsider previous findings in major depressive disorder (MDD) reporting (1) a diminished contrast sensitivity and (2) a reduced patten ERG (PERG) amplitude ratio, and additionally, to assess (3) the photopic negative response (PhNR) from the flash ERG (fERG), with the RETeval® device, a more practical option for clinical routine use. We examined 30 patients with a MDD and 42 healthy controls (HC), assessing individual contrast sensitivity thresholds with an optotype-based contrast test. Moreover, we compared the PERG ratio, an established method for early glaucoma detection, between both groups. The handheld ERG device was used to measure amplitudes and peak times of the fERG components including a-wave, b-wave and PhNR in both MDD patients and HCs. MDD patients exhibited diminished contrast sensitivity together with a reduced PERG ratio, compared to HC. With the handheld ERG device, we found reduced a-wave amplitudes in MDD, whereas no significant differences were observed in the fERG b-wave or PhNR between patients and controls. The reduced contrast sensitivity and PERG ratio in MDD patients supports the hypothesis that depression is associated with altered visual processing. The findings underscore the PERG's potential as a possible objective marker for depression. The reduced a-wave amplitude recorded with the RETeval® system in MDD patients might open new avenues for using handheld ERG devices as simplified approaches for advancing depression research compared to the PERG.

2.
Doc Ophthalmol ; 148(2): 87-95, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38416305

RESUMO

PURPOSE: The steady-state pattern electroretinogram (ssPERG) is used to assess retinal ganglion cell function in a variety of research contexts and diagnostic applications. In certain groups of patients or study participants, stable central fixation of the stimulus is not guaranteed. The present study aimed at assessing the effects of misfixation on the ssPERG response to checkerboard reversal stimuli. METHODS: Using two check sizes (0.8° and 15°), we compared ssPERG responses for several amounts of fixation deviation, ranging from 0° to 19° horizontally and from 0° to 14° diagonally. The stimulus area extended to 15° eccentricity, stimulus reversal rate was 15/s. RESULTS: Up to around 7° eccentricity, there was no sizable effect of fixation deviation under most conditions. Effects were somewhat larger for nasal than for temporal deviation, in particular for small checks. Diagonal deviation was associated with a response to luminance onset/offset at 7.5 Hz (subharmonic of the reversal rate), most prominently when the interior of a large check was fixated. CONCLUSION: Generally, moderate inaccuracies of fixation do not have a sizable effect on ssPERG amplitude. However, with large checks, the luminance response has to be considered.


Assuntos
Eletrorretinografia , Reconhecimento Visual de Modelos , Humanos , Reconhecimento Visual de Modelos/fisiologia , Células Ganglionares da Retina/fisiologia
3.
J Autism Dev Disord ; 2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36550331

RESUMO

Since the retina shares its embryological origin with the central nervous system, optical coherence tomography (OCT), an imaging technique frequently employed in ophthalmology to analyze the macula and intraretinal layer thicknesses and volumes, has recently become increasingly important in psychiatric research. We examined 34 autistic and 31 neurotypical adults (NT) using OCT. Autistic adults had reduced overall macular and outer nuclear layer (ONL) thickness and volume compared to NT. Both macular and ONL thickness showed significant inverse associations with the severity of autistic symptoms measured with the Social Responsiveness Scale 2 (SRS-2). Longitudinal studies across different age groups are required to clarify whether retinal changes may represent a possible trait marker.

4.
Autism Res ; 15(11): 2026-2037, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36217563

RESUMO

The electroretinogram (ERG) allows the investigation of retinal signaling pathways and has increasingly been applied in individuals with mental disorders in search for potential biomarkers of neurodevelopmental disorders. Preceding ERG examinations in individuals with autism spectrum disorders (ASD) showed inconsistent results, which might be due to the small number of participants, heterogeneity of the ASD population, differences in age ranges, and stimulation methods. The aim of this study was to investigate functional retinal responses in adults with ASD by means of the light-adapted (photopic) ERG. Light-adapted ERG measurements were obtained with the RETeval® system applying three different stimulation protocols. In the final analysis, the ERG parameters a-wave, b-wave, the photopic negative response (PhNR), the photopic hill parameters as well as additional amplitude ratios were compared between 32 adults with high-functioning ASD and 31 non-autistic controls. Both groups were matched with regard to sex and age. No significant functional retinal differences in amplitude or peak time of the a- or b-wave, PhNR, the photopic hill parameters or the ERG-amplitude ratios could be detected in individuals with ASD compared to non-autistic participants. The absence of electrophysiological functional retinal alterations in ASD, suggests that changes in visual perception, such as increased attention to detail or visual hypersensitivity in ASD, are not due to impairments at early levels of retinal signal processing.


Assuntos
Transtorno do Espectro Autista , Eletrorretinografia , Adulto , Humanos , Eletrorretinografia/métodos , Células Ganglionares da Retina/fisiologia , Estimulação Luminosa , Retina/fisiologia
5.
Transl Psychiatry ; 12(1): 402, 2022 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-36151078

RESUMO

Ophthalmological methods have increasingly raised the interest of neuropsychiatric specialists. While the integrity of the retinal cell functions can be evaluated with the electroretinogram (ERG), optical coherence tomography (OCT) allows a structural investigation of retinal layer thicknesses. Previous studies indicate possible functional and structural retinal alterations in patients with schizophrenia. Twenty-five patients with paranoid schizophrenia and 25 healthy controls (HC) matched for age, sex, and smoking status participated in this study. Both, ERG and OCT were applied to obtain further insights into functional and structural retinal alterations. A significantly reduced a-wave amplitude and thickness of the corresponding para- and perifoveal outer nuclear layer (ONL) was detected in patients with paranoid schizophrenia with a positive correlation between both measurement parameters. Amplitude and peak time of the photopic negative response (PhNR) and thickness of the parafoveal ganglion cell layer (GCL) were decreased in patients with schizophrenia compared to HC. Our results show both structural and functional retinal differences between patients with paranoid schizophrenia and HC. We therefore recommend the comprehensive assessment of the visual system of patients with schizophrenia, especially to further investigate the effect of antipsychotic medication, the duration of illness, or other factors such as inflammatory or neurodegenerative processes. Moreover, longitudinal studies are required to investigate whether the functional alterations precede the structural changes.


Assuntos
Antipsicóticos , Células Ganglionares da Retina , Eletrorretinografia/métodos , Humanos , Retina/diagnóstico por imagem , Células Ganglionares da Retina/fisiologia , Esquizofrenia Paranoide/diagnóstico por imagem
6.
Front Med (Lausanne) ; 8: 732222, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34778295

RESUMO

Background: The retina has gained increasing attention in non-ophthalmological research in recent years. The pattern electroretinogram (PERG), a method to evaluate retinal ganglion cell function, has been used to identify objective correlates of the essentially subjective state of depression. A reduction in the PERG contrast gain was demonstrated in patients with depression compared to healthy controls with normalization after remission. PERG responses are not only modulated by stimulus contrast, but also by check size and stimulation frequency. Therefore, the rationale was to evaluate potentially more feasible procedures for PERG recordings in daily diagnostics in psychiatry. Methods: Twenty-four participants (12 patients with major depression (MDD) and 12 age- and sex-matched healthy controls) were examined in this pilot study. We investigated PERG amplitudes for two steady-state pattern reversal frequencies (12.5/18.75 rps) and four sizes of a checkerboard stimulus (0.8°, 1.6°, 3.2°, and 16°) to optimize the PERG recordings in MDD patients. Results: Smaller PERG amplitudes in MDD patients were observed for all parameters, whereby the extent of the reduction appeared to be stimulus-specific. The most pronounced decline in the PERG of MDD patients was observed at the higher stimulation frequency and the finest pattern, whilst responses for the largest check size were less affected. Following the PERG ratio protocol for early glaucoma, where similar stimulus dependent modulations have been reported, we calculated PERG ratios (0.8°/16°) for all participants. At the higher frequency (18.75 rps), significantly reduced ratios were observed in MDD patients. Conclusion: The "normalization" of the PERG responses-via building a ratio-appears to be a very promising approach with regard to the development of an objective biomarker of the depressive state, facilitating inter-individual assessments of PERG recordings in patients with psychiatric disorders.

7.
Multisens Res ; 33(3): 251-275, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31972541

RESUMO

Are alternation and co-occurrence of stimuli of different sensory modalities conspicuous? In a novel audio-visual oddball paradigm, the P300 was used as an index of the allocation of attention to investigate stimulus- and task-related interactions between modalities. Specifically, we assessed effects of modality alternation and the salience of conjunct oddball stimuli that were defined by the co-occurrence of both modalities. We presented (a) crossmodal audio-visual oddball sequences, where both oddballs and standards were unimodal, but of a different modality (i.e., visual oddball with auditory standard, or vice versa), and (b) oddball sequences where standards were randomly of either modality while the oddballs were a combination of both modalities (conjunct stimuli). Subjects were instructed to attend to one of the modalities (whether part of a conjunct stimulus or not). In addition, we also tested specific attention to the conjunct stimuli. P300-like responses occurred even when the oddball was of the unattended modality. The pattern of event-related potential (ERP) responses obtained with the two crossmodal oddball sequences switched symmetrically between stimulus modalities when the task modality was switched. Conjunct oddballs elicited no oddball response if only one modality was attended. However, when conjunctness was specifically attended, an oddball response was obtained. Crossmodal oddballs capture sufficient attention even when not attended. Conjunct oddballs, however, are not sufficiently salient to attract attention when the task is unimodal. Even when specifically attended, the processing of conjunctness appears to involve additional steps that delay the oddball response.


Assuntos
Atenção/fisiologia , Percepção Auditiva/fisiologia , Potenciais Evocados Auditivos/fisiologia , Potenciais Evocados/fisiologia , Audição/fisiologia , Tempo de Reação/fisiologia , Estimulação Acústica , Adulto , Mapeamento Encefálico , Eletroencefalografia , Feminino , Testes Auditivos , Humanos , Masculino , Estimulação Luminosa , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA