Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
Eur Heart J ; 45(12): 987-997, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538149

RESUMO

Patients with severe mental illness (SMI) including schizophrenia and bipolar disorder die on average 15-20 years earlier than the general population often due to sudden death that, in most cases, is caused by cardiovascular disease. This state-of-the-art review aims to address the complex association between SMI and cardiovascular risk, explore disparities in cardiovascular care pathways, describe how to adequately predict cardiovascular outcomes, and propose targeted interventions to improve cardiovascular health in patients with SMI. These patients have an adverse cardiovascular risk factor profile due to an interplay between biological factors such as chronic inflammation, patient factors such as excessive smoking, and healthcare system factors such as stigma and discrimination. Several disparities in cardiovascular care pathways have been demonstrated in patients with SMI, resulting in a 47% lower likelihood of undergoing invasive coronary procedures and substantially lower rates of prescribed standard secondary prevention medications compared with the general population. Although early cardiovascular risk prediction is important, conventional risk prediction models do not accurately predict long-term cardiovascular outcomes as cardiovascular disease and mortality are only partly driven by traditional risk factors in this patient group. As such, SMI-specific risk prediction models and clinical tools such as the electrocardiogram and echocardiogram are necessary when assessing and managing cardiovascular risk associated with SMI. In conclusion, there is a necessity for differentiated cardiovascular care in patients with SMI. By addressing factors involved in the excess cardiovascular risk, reconsidering risk stratification approaches, and implementing multidisciplinary care models, clinicians can take steps towards improving cardiovascular health and long-term outcomes in patients with SMI.


Assuntos
Doenças Cardiovasculares , Transtornos Mentais , Humanos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Doenças Cardiovasculares/complicações , Fatores de Risco , Transtornos Mentais/complicações , Transtornos Mentais/epidemiologia , Transtornos Mentais/terapia , Medição de Risco , Fatores de Risco de Doenças Cardíacas
2.
J Cardiovasc Electrophysiol ; 35(5): 950-964, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38477184

RESUMO

INTRODUCTION: Peak frequency (PF) mapping is a novel method that may identify critical portions of myocardial substrate supporting reentry. The aim of this study was to describe and evaluate PF mapping combined with omnipolar voltage mapping in the identification of critical isthmuses of left atrial (LA) atypical flutters. METHODS AND RESULTS: LA omnipolar voltage and PF maps were generated in flutter using the Advisor HD-Grid catheter (Abbott) and EnSite Precision Mapping System (Abbott) in 12 patients. Normal voltage was defined as ≥0.5 mV, low-voltage as 0.1-0.5 mV, and scar as <0.1 mV. PF distributions were compared with ANOVA and post hoc Tukey analyses. The 1 cm radius from arrhythmia termination was compared to global myocardium with unpaired t-testing. The mean age was 65.8 ± 9.7 years and 50% of patients were female. Overall, 34 312 points were analyzed. Atypical flutters most frequently involved the mitral isthmus (58%) or anterior wall (25%). Mean PF varied significantly by myocardial voltage: normal (335.5 ± 115.0 Hz), low (274.6 ± 144.0 Hz), and scar (71.6 ± 140.5 Hz) (p < .0001 for all pairwise comparisons). All termination sites resided in low-voltage regions containing intermediate or high PF. Overall, mean voltage in the 1 cm radius from termination was significantly lower than the remaining myocardium (0.58 vs. 0.95 mV, p < .0001) and PF was significantly higher (326.4 vs. 245.1 Hz, p < .0001). CONCLUSION: Low-voltage, high-PF areas may be critical targets during catheter ablation of atypical atrial flutter.


Assuntos
Potenciais de Ação , Flutter Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Valor Preditivo dos Testes , Humanos , Flutter Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Frequência Cardíaca
3.
Heart Rhythm ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38360252

RESUMO

BACKGROUND: Women might benefit more than men from cardiac resynchronization therapy (CRT) and do so at shorter QRS durations. OBJECTIVE: This meta-analysis was performed to determine whether sex-based differences in CRT effects are better accounted for by height, body surface area (BSA), or left ventricular end-diastolic dimension (LVEDD). METHODS: We analyzed patient-level data from CRT trials (MIRACLE, MIRACLE ICD, MIRACLE ICD II, REVERSE, RAFT, COMPANION, and MADIT-CRT) using bayesian hierarchical Weibull regression models. Relationships between QRS duration and CRT effects were examined overall and in sex-stratified cohorts; additional analyses indexed QRS duration by height, BSA, or LVEDD. End points were heart failure hospitalization (HFH) or death and all-cause mortality. RESULTS: Compared with men (n = 5628), women (n = 1439) were shorter (1.62 [interquartile range, 1.57-1.65] m vs 1.75 [1.70-1.80] m; P < .001), with smaller BSAs (1.76 [1.62-1.90] m2 vs 2.02 [1.89-2.16] m2; P < .001). In adjusted sex-stratified analyses, the reduction in HFH or death was greater for women (hazard ratio, 0.54; credible interval, 0.42-0.70) than for men (hazard ratio, 0.77; credible interval, 0.66-0.89; Pinteraction = .009); results were similar for all-cause mortality even after adjustment for height, BSA, and LVEDD. Sex-specific differences were observed only in nonischemic cardiomyopathy. The effect of CRT on HFH or death was observed at a shorter QRS duration for women (126 ms) than for men (145 ms). Indexing QRS duration by height, BSA, or LVEDD attenuated sex-specific QRS duration thresholds for the effects of CRT on HFH or death but not on mortality. CONCLUSION: Although body size partially explains sex-specific QRS duration thresholds for CRT benefit, it is not associated with the magnitude of CRT benefit. Indexing QRS duration for body size might improve selection of patients for CRT, particularly with a "borderline" QRS duration. GOV REGISTRATION: NCT00271154, NCT00251251, NCT00267098, NCT00180271.

4.
Circ Arrhythm Electrophysiol ; 17(4): e012424, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390713

RESUMO

BACKGROUND: The National Cardiovascular Data Registry Left Atrial Appendage Occlusion Registry (LAAO) includes the vast majority of transcatheter LAAO procedures performed in the United States. The objective of this study was to develop a model predicting adverse events among patients undergoing LAAO with Watchman FLX. METHODS: Data from 41 001 LAAO procedures with Watchman FLX from July 2020 to September 2021 were used to develop and validate a model predicting in-hospital major adverse events. Randomly selected development (70%, n=28 530) and validation (30%, n=12 471) cohorts were analyzed with 1000 bootstrapped samples, using forward stepwise logistic regression to create the final model. A simplified bedside risk score was also developed using this model. RESULTS: Increased age, female sex, low preprocedure hemoglobin, no prior attempt at atrial fibrillation termination, and increased fall risk most strongly predicted in-hospital major adverse events and were included in the final model along with other clinically relevant variables. The median in-hospital risk-standardized adverse event rate was 1.50% (range, 1.03%-2.84%; interquartile range, 1.42%-1.64%). The model demonstrated moderate discrimination (development C-index, 0.67 [95% CI, 0.65-0.70] and validation C-index, 0.66 [95% CI, 0.62-0.70]) with good calibration. The simplified risk score was well calibrated with risk of in-hospital major adverse events ranging from 0.26% to 3.90% for a score of 0 to 8, respectively. CONCLUSIONS: A transcatheter LAAO risk model using National Cardiovascular Data Registry and LAAO Registry data can predict in-hospital major adverse events, demonstrated consistency across hospitals and can be used for quality improvement efforts. A simple bedside risk score was similarly predictive and may inform shared decision-making.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Feminino , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fatores de Risco , Resultado do Tratamento
5.
HeartRhythm Case Rep ; 10(2): 158-161, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38404970
6.
Heart Rhythm ; 21(4): 471-483, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38101500

RESUMO

Catheter ablation of atrial fibrillation (AF) is an established therapy that reduces AF burden, improves quality of life, and reduces the risks of cardiovascular outcomes. Although there are clear guidelines for the application of de novo catheter ablation, there is less evidence to guide recommendations for repeat catheter ablation in patients who experience recurrent AF. In this review, we examine the rationale for repeat ablation, mechanisms of recurrence, patient selection, optimal timing, and procedural strategies. We discuss additional important considerations, including treatment of comorbidities and risk factors, risk of complications, and effectiveness. Mechanisms of recurrent AF are often due to non-pulmonary vein (non-PV) triggers; however, there is insufficient evidence supporting the routine use of empiric lesion sets during repeat ablation. The emergence of pulsed field ablation may alter the safety and effectiveness of de novo and repeat ablation. Extrapolation of data from randomized trials of de novo ablation does not optimally inform efficacy in cases of redo ablation. Additional large, randomized controlled trials are needed to address important clinical questions regarding procedural strategies and timing of repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Qualidade de Vida , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
7.
Am Heart J ; 267: 81-90, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37984672

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces heart failure hospitalizations (HFH) and mortality for guideline-indicated patients with heart failure (HF). Most patients with HF are aged ≥70 years but such patients are often under-represented in randomized trials. METHODS: Patient-level data were combined from 8 randomized trials published 2002-2013 comparing CRT to no CRT (n = 6,369). The effect of CRT was estimated using an adjusted Bayesian survival model. Using age as a categorical (<70 vs ≥70 years) or continuous variable, the interaction between age and CRT on the composite end point of HFH or all-cause mortality or all-cause mortality alone was assessed. RESULTS: The median age was 67 years with 2436 (38%) being 70+; 1,554 (24%) were women; 2,586 (41%) had nonischemic cardiomyopathy and median QRS duration was 160 ms. Overall, CRT was associated with a delay in time to the composite end point (adjusted hazard ratio [aHR] 0.75, 95% credible interval [CI] 0.66-0.85, P = .002) and all-cause mortality alone (aHR of 0.80, 95% CI 0.69-0.96, P = .017). When age was treated as a categorical variable, there was no interaction between age and the effect of CRT for either end point (P > .1). When age was treated as a continuous variable, older patients appeared to obtain greater benefit with CRT for the composite end point (P for interaction = .027) with a similar but nonsignificant trend for mortality (P for interaction = .35). CONCLUSION: Reductions in HFH and mortality with CRT are as great or greater in appropriately indicated older patients. Age should not be a limiting factor for the provision of CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Feminino , Idoso , Masculino , Teorema de Bayes , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Modelos de Riscos Proporcionais
8.
Eur J Heart Fail ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37671601

RESUMO

AIMS: Patients with heart failure usually have several other medical conditions that might alter the effects of interventions. We investigated whether the burden of comorbidity modified the clinical response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Original patient-level data from eight randomized trials exploring the effects of CRT versus no CRT were pooled (BLOCK-HF, MIRACLE, MIRACLE-ICD, MIRACLE-ICD II, RAFT, COMPANION, MADIT-CRT and REVERSE). A prior history of the following comorbidities was considered: episodic or persistent atrial fibrillation (n = 920), coronary artery disease (n = 3732), diabetes (n = 2171), and hypertension (n = 3353). Patients were classified into three groups based on the number of comorbidities: 0, 1-2, or ≥3. The outcomes of interest were time to all-cause mortality and time to the composite outcome of heart failure hospitalization (HFH) or all-cause mortality. Outcomes were evaluated within each comorbidity group using a Bayesian hierarchical Weibull survival regression model. Of 6324 patients, 970 (15%) had no comorbidities, 4052 (64%) had 1-2 and 1302 (21%) had ≥3 comorbidities. The adjusted hazard ratio (aHR) for CRT versus no CRT for all-cause mortality in the overall cohort was 0.79 (95% credible interval [CI] 0.68-0.93) (p = 0.010); for no comorbidities the aHR was 0.54 (95% CI 0.34-0.86), for 1-2 comorbidities was 0.81 (95% CI 0.67-0.97) and for ≥3 comorbidities was 0.83 (95% CI 0.64-1.07) (no significant interaction between CRT and comorbidity burden: p = 0.13). For the endpoint of HFH or all-cause mortality, the aHR for the overall cohort was 0.74 (95% CI 0.65-0.84) (p = 0.001), for no comorbidities was 0.69 (95% CI 0.50-0.94), for 1-2 comorbidities was 0.77 (95% CI 0.66-0.90) and for ≥3 comorbidities was 0.68 (95% CI 0.55-0.82) (no significant interaction between CRT and comorbidity burden: p = 0.081). CONCLUSION: In a meta-analysis of patient-level data from eight major trials, the totality of evidence suggests that CRT reduces HFH and/or all-cause mortality even when several comorbid diseases are present. CLINICAL TRIAL REGISTRATION: NCT00271154, NCT00251251, NCT00267098, NCT00180271.

9.
J Am Heart Assoc ; 12(16): e029293, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37586066

RESUMO

Background There is uncertainty about the appropriate use of primary prevention implantable cardioverter-defibrillators (ICDs) among older patients with hypertrophic cardiomyopathy. Methods and Results Patients with hypertrophic cardiomyopathy who received a primary prevention ICD between 2010 and 2016 were identified using the National Cardiovascular Data Registry ICD Registry. Trends in ICD utilization and patient characteristics were assessed over time. Using linked Centers for Medicare and Medicaid Service claims data, Cox proportional hazard models assessed factors associated with mortality and postdischarge hospitalization for cardiac arrest/ventricular arrhythmia. Of 5571 patients with hypertrophic cardiomyopathy, 1511 (27.1%) were ≥65 years old. ICD utilization increased over time in all age groups. There were no changes in the prevalence of risk factors for sudden cardiac death over time. The variables most strongly associated with postdischarge mortality were older age (adjusted hazard ratio (aHR) 1.80 [95% CI, 1.47-2.21]), New York Heart Association class (III/IV versus I/II aHR 2.17 [95% CI, 1.57-2.98]), and left ventricular ejection fraction (left ventricular ejection fraction ≤35% versus >50% aHR 2.34 [95% CI, 1.58-3.48]; left ventricular ejection fraction 36%-50% versus >50% aHR 2.98 [95% CI, 2.02-4.40]), while history of nonsustained ventricular tachycardia (aHR 2.38 [95% CI, 1.62-3.51]) and New York Heart Association class (III/IV versus I/II aHR 1.84 [95% CI, 1.22-2.78]) were strongly associated with hospitalization for ventricular arrhythmia/cardiac arrest. Conclusions Primary prevention ICD utilization in patients with hypertrophic cardiomyopathy increased over time, including among those ≥65 years old. Among older patients, the strongest risk factors for hospitalization for ventricular arrhythmia/cardiac arrest following ICD implantation were history of nonsustained ventricular tachycardia and New York Heart Association class.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Parada Cardíaca , Taquicardia Ventricular , Humanos , Idoso , Estados Unidos/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Assistência ao Convalescente , Função Ventricular Esquerda , Medicare , Alta do Paciente , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Arritmias Cardíacas/complicações , Fatores de Risco , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Parada Cardíaca/epidemiologia , Parada Cardíaca/terapia , Parada Cardíaca/complicações , Prevenção Primária
10.
Heart Rhythm ; 20(10): 1420-1428, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37406870

RESUMO

BACKGROUND: Left ventricular (LV) lead implantation is often the most challenging aspect of cardiac resynchronization therapy (CRT) procedures; early studies reported implant failure rates in ∼10% of cases. OBJECTIVE: The purpose of this study was to define rates, reasons for, and factors independently associated with LV lead implant failure. METHODS: We studied patients with left bundle branch block and ejection fraction ≤ 35% who underwent planned de novo transvenous CRT implantation (2010-2016) and were reported to the National Cardiovascular Data Registry ICD Registry. Independent predictors of LV lead implant failure were determined using logistic regression; age, sex, and variables with a univariable P value of <.15 were considered for inclusion in the model. RESULTS: Of the 111,802 patients who underwent a planned CRT procedure, 3.6% of patients (n = 3979) had LV lead implant failure. Reasons for implant failure included venous access (7.5%), coronary sinus access (64.3%), tributary vein access (13.5%), coronary sinus dissection (7.6%), unacceptable threshold (4.4%), and diaphragmatic stimulation (1.7%). Significant independent predictors of LV lead implant failure included younger age (odds ratio [OR] 1.01; 95% confidence interval [CI] 0.1.01-1.02), female sex (OR 1.38; 95% CI 1.29-1.47), black race (vs white, OR 1.44; 95% CI 1.32-1.57), Hispanic ethnicity (OR 1.23; 95% CI 1.08-1.40), QRS duration (OR 1.055 per 10 ms; 95% CI 1.038-1.072 per 10 ms), obstructive sleep apnea (OR 1.14; 95% CI 1.04-1.24), and implantation by a physician without specialized training (vs electrophysiology trained, OR 1.53; 95% CI 1.34-1.76). CONCLUSION: LV lead implant failure is uncommon in the current era and is most commonly due to coronary sinus access failure. Predictors of LV lead implant failure included younger age, female sex, black race, Hispanic ethnicity, increased QRS duration, sleep apnea, and absence of electrophysiology training.

11.
J Cardiovasc Electrophysiol ; 34(9): 1914-1924, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37522254

RESUMO

AIMS: To investigate the association of cardiac resynchronization therapy (CRT) on outcomes among participants with and without a history of atrial fibrillation (AF). METHODS: Individual-patient-data from four randomized trials investigating CRT-Defibrillators (COMPANION, MADIT-CRT, REVERSE) or CRT-Pacemakers (COMPANION, MIRACLE) were analyzed. Outcomes were time to a composite of heart failure hospitalization or all-cause mortality or to all-cause mortality alone. The association of CRT on outcomes for patients with and without a history of AF was assessed using a Bayesian-Weibull survival regression model adjusting for baseline characteristics. RESULTS: Of 3964 patients included, 586 (14.8%) had a history of AF; 2245 (66%) were randomized to CRT. Overall, CRT reduced the risk of the primary composite endpoint (hazard ratio [HR]: 0.69, 95% credible interval [CI]: 0.56-0.81). The effect was similar (posterior probability of no interaction = 0.26) in patients with (HR: 0.78, 95% CI: 0.55-1.10) and without a history of AF (HR: 0.67, 95% CI: 0.55-0.80). In these four trials, CRT did not reduce mortality overall (HR: 0.82, 95% CI: 0.66-1.01) without evidence of interaction (posterior probability of no interaction = 0.14) for patients with (HR: 1.09, 95% CI: 0.70-1.74) or without a history of AF (HR: 0.70, 95% CI: 0.60-0.97). CONCLUSION: The association of CRT on the composite endpoint or mortality was not statistically different for patients with or without a history of AF, but this could reflect inadequate power. Our results call for trials to confirm the benefit of CRT recipients with a history of AF.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/métodos , Teorema de Bayes , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
12.
medRxiv ; 2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37461448

RESUMO

Data on the benefits of cardiac resynchronization therapy (CRT) in patients with severe heart failure (HF) symptoms are limited. We investigated the relative effects of CRT in patients with ambulatory NYHA IV vs. III functional class at the time of device implantation. In this meta-analysis, we pooled patient-level data from the MIRACLE, MIRACLE-ICD, and COMPANION trials. Outcomes evaluated were time to the composite endpoint of first HF hospitalization (HFH) or all-cause mortality and time to all-cause mortality alone. The association between CRT and outcomes was evaluated using a Bayesian Hierarchical Weibull survival regression model. We assessed if this association differs between NYHA III and IV groups by adding an interaction term between CRT and NYHA class as a random effect. A sensitivity analysis was performed by including data from the RAFT trial. Our pooled analysis included 2309 patients. Overall, CRT was associated with a longer time to HFH or all-cause mortality (adjusted hazard ratio [aHR] 0.79, 95%CI 0.64 - 0.99, p = 0.044), with a similar association with time to all-cause mortality (aHR 0.78, 95% CI 0.59 - 1.03, p = 0.083). Associations of CRT with outcomes were not significantly different for those in NYHA III and IV classes (ratio of aHR 0.72, 95% CI 0.30 - 1.27, p = 0.23 for HFH/mortality; ratio of aHR 0.70, 95% CI 0.35 - 1.34, p = 0.27 for all-cause mortality alone). The sensitivity analysis, including RAFT data, did not show a significant relative CRT benefit between NYHA III and IV classes. Overall, there was no significant difference in the association of CRT with either outcome for patients in NYHA functional class III compared with functional class IV.

13.
Clinicoecon Outcomes Res ; 15: 387-395, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37273820

RESUMO

Background: Atrial fibrillation (AF) is associated with considerable morbidity and mortality. Timely management and treatment is critical in alleviating AF disease burden. Variation in treatment by race and ethnic and sex could lead to inequities in health outcomes. Objective: To identify racial and ethnic and sex differences in rhythm treatment for patients with incident AF. Methods: Using 2010-2019 Optum Clinformatics database, an administrative claims data for commercially insured patients in the United States (US), incident AF patients ≥20 years old who were continuously enrolled 12-months pre- and post-index diagnosis were identified. Rhythm control treatment (ablation, antiarrhythmic drugs [AAD], and cardioversion) for AF were compared by patient race and ethnicity (Asian, Hispanic, Black vs White) and sex (female vs male). Multivariable regression analysis was used to examine the relationship of race and ethnicity and sex with rhythm control AF treatment. Results: A total of 77,932 patients were identified with incident AF. Black and Hispanic female patients had the highest CHA2DS2VASc scores (4.3 ± 1.8) and Elixhauser scores (4.1 ± 2.8 and 4.0 ± 6.7), respectively. Black males were less likely to receive AAD treatment (adjusted odds ratio [aOR] 0.87; 95% confidence interval [CI], 0.79-0.96) or ablation (aOR, 0.72; 95% CI, 0.58-0.90). Compared to White males, all groups had lower likelihood of receiving cardioversion with Asian females having the lowest [aOR, 0.48; 95% CI, (0.37-0.63)]. Conclusion: Black patients were less likely to receive pharmacologic and procedural rhythm control therapies. Further research is needed to understand the drivers of undertreatment among racial and ethnic groups and females with AF.

14.
JACC Cardiovasc Interv ; 16(11): 1317-1328, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37316143

RESUMO

BACKGROUND: The impact of preprocedure imaging on the safety and effectiveness of left atrial appendage occlusion (LAAO) remains unclear. OBJECTIVES: This study sought to determine the rates of use of preprocedure computed tomography (CT)/cardiac magnetic resonance (CMR) and its association with safety and effectiveness of LAAO procedures. METHODS: The National Cardiovascular Data Registry LAAO Registry was used to evaluate patients who underwent attempted LAAO with the WATCHMAN and WATCHMAN FLX devices between January 1, 2016, and June 30, 2021. Safety and effectiveness of LAAO procedures was compared by use vs nonuse of preprocedural CT/CMR. Outcomes of interest included implantation success (deployment and release of device), device success (device released with peridevice leak <5 mm), and procedure success (device released with peridevice leak <5 mm and no in-hospital major adverse events [MAE]). Multivariable logistic regression was used to assess the relationship between preprocedure imaging and outcomes. RESULTS: Preprocedure CT/CMR was used for 18.2% (n = 20,851) of the 114,384 procedures in this study. CT/CMR use was more common among government and university hospitals and hospitals in the Midwest and South; it was less common among patients with uncontrolled hypertension, with abnormal renal function, and without prior thromboembolism. Overall rates of implantation success, device success, and procedure success were 93.4%, 91.2%, and 89.4%, respectively. Preprocedure CT/CMR was independently associated with an increased likelihood of implantation success (OR: 1.08; 95% CI: 1.00-1.17), device success (OR: 1.10; 95% CI: 1.04-1.16), and procedural success (OR: 1.07; 95% CI: 1.02-1.13). MAE were uncommon (2.3%) and not associated with use of preprocedure CT/CMR (OR: 1.02; 95% CI: 0.92-1.12). CONCLUSIONS: Preprocedure CT/CMR was associated with an increased likelihood of successful LAAO implantation; however, the magnitude of benefit appears small and it was not associated with MAE.


Assuntos
Apêndice Atrial , Hipertensão , Humanos , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Sistema de Registros
15.
J Cardiovasc Electrophysiol ; 34(7): 1561-1568, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37330678

RESUMO

INTRODUCTION: Transvenous implantable cardioverter-defibrillator (ICD) shocks have been associated with cardiac biomarker elevations and are thought in some cases to contribute to adverse clinical outcomes and mortality, possibly from myocardium exposed to excessive shock voltage gradients. Currently, there are only limited data for comparison with subcutaneous ICDs. We sought to compare ventricular myocardium voltage gradients resulting from transvenous (TV) and subcutaneous defibrillator (S-ICD) shocks to assess their risk of myocardial damage. METHODS: A finite element model was derived from thoracic magnetic resonance imaging (MRI). Voltage gradients were modeled for an S-ICD with a left-sided parasternal coil and a left-sided TV-ICD with a mid-cavity, a septal right ventricle (RV) coil, or a dual coil lead (TV mid, TV septal, TV septal + superior vena cava [SVC]). High gradients were defined as > 100 V/cm. RESULTS: The volumes of ventricular myocardium with high gradients > 100 V/cm were 0.02, 2.4, 7.7, and 0 cc for TV mid, TV septal, TV septal + SVC, and S-ICD, respectively. CONCLUSION: Our models suggest that S-ICD shocks produce more uniform gradients in the myocardium, with less exposure to potentially damaging electrical fields, compared to TV-ICDs. Dual coil TV leads yield higher gradients, as does closer proximity of the shock coil to the myocardium.


Assuntos
Desfibriladores Implantáveis , Veia Cava Superior , Humanos , Ventrículos do Coração , Miocárdio , Tela Subcutânea/diagnóstico por imagem
16.
Heart Rhythm O2 ; 4(5): 291-297, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37323995

RESUMO

Background: Catheter ablation is recommended for the treatment of symptomatic atrial fibrillation (AF) refractory to medical therapy. Objective: The study sought to examine racial/ethnic and sex differences in complications and AF/atrial flutter (AFL)-related acute healthcare utilization following catheter ablation for AF. Methods: We performed a retrospective analysis using data from the Centers for Medicare and Medicaid Services Medicare Standard Analytical Files (October 1, 2014, to September 30, 2019) among patients ≥65 years of age with AF who underwent catheter ablation for rhythm control. The risk of any complication within 30 days and AF/AFL-related acute healthcare utilization within 1 year of ablation by race, ethnicity, and sex were assessed using multivariable Cox regression modeling. Results: We identified 95,394 patients for analysis of postablation complications and 68,408 patients for analysis of AF/AFL-related acute healthcare utilization. Both cohorts were ∼95% White and 52% male. Female patients had a slightly elevated risk of complications compared with male patients (adjusted hazard ratio [aHR] 1.07, 95% confidence interval [CI] 1.03-1.12). Black (aHR 0.78, 95% CI 0.77-1.00) and Asian (aHR 0.67, 95% CI 0.50-0.89) patients had lower utilization compared with White patients. Specifically, Asian men (aHR 0.58, 95% CI 0.38-0.91) had lower utilization compared with White men. Conclusion: Differences in safety and healthcare utilization after catheter ablation for AF were observed by race/ethnicity and sex groups. Underrepresented racial and ethnic groups with AF had a lower risk of AF/AFL-related acute healthcare utilization postablation.

18.
J Cardiovasc Electrophysiol ; 34(5): 1192-1195, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37078339

RESUMO

INTRODUCTION: Incomplete anchoring of the Watchman left atrial appendage closure (LAAO) device can result in substantial device migration or device embolization (DME) requiring percutaneous or surgical retrieval. METHODS: We performed a retrospective analysis of Watchman procedures (January 2016 through March 2021) reported to the National Cardiovascular Data Registry LAAO Registry. We excluded patients with prior LAAO interventions, no device released, and missing device information. In-hospital events were assessed among all patients and postdischarge events were assessed among patients with 45-day follow-up. RESULTS: Of 120 278 Watchman procedures, the in-hospital DME rate was 0.07% (n = 84) and surgery was commonly performed (n = 39). In-hospital mortality rate was 14% among patients with DME and 20.5% among patients who underwent surgery. In-hospital DME was more common: at hospitals with a lower median annual procedure volume (24 vs. 41 procedures, p < .0001), with Watchman 2.5 versus Watchman FLX devices (0.08% vs. 0.04%, p = .0048), with larger LAA ostia (median 23 vs. 21 mm, p = .004), and with a smaller difference between device and LAA ostial size (median difference 4 vs. 5 mm, p = .04). Of 98 147 patients with 45-day follow-up, postdischarge DME occurred in 0.06% (n = 54) patients and cardiac surgery was performed in 7.4% (n = 4) of cases. The 45-day mortality rate was 3.7% (n = 2) among patients with postdischarge DME. Postdischarge DME was more common among men (79.7% of events but 58.9% of all procedures, p = .0019), taller patients (177.9 vs. 172 cm, p = .0005), and those with greater body mass (99.9 vs. 85.5 kg, p = .0055). The rhythm at implant was less frequently AF among patients with DME compared to those without (38.9% vs. 46.9%, p = .0098). CONCLUSION: While Watchman DME is rare, it is associated with high mortality and frequently requires surgical retrieval, and a substantial proportion of events occur after discharge. Due to the severity of DME events, risk mitigation strategies and on-site cardiac surgical back-up are of paramount importance.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Masculino , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Assistência ao Convalescente , Alta do Paciente , Sistema de Registros , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Cateterismo Cardíaco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA