Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Transl Oncol ; 21: 101445, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35523007

RESUMO

Prostate specific membrane antigen (PSMA) is a transmembrane protein that is highly expressed on prostate epithelial cells and is strongly upregulated in prostate cancer. Radioligand therapy using beta-emitting Lutetium-177 (177Lu)-labeled-PSMA-617, a radiolabeled small molecule, has gained attention as a novel targeted therapy for metastatic prostate cancer, given its high affinity and long tumor retention, and rapid blood pool clearance. In March 2022, the United States Food and Drug administration has granted approval to the targeted 177Lu-PSMA-617 therapy for treatment of patients with PSMA-positive metastatic castration resistant prostate cancer, who have been previously treated with an androgen-receptor pathway inhibitor and taxane-based chemotherapy. Studies have demonstrated the adverse effects of this treatment, mainly encountered due to radiation exposure to non-target tissues. Salivary glands show high PSMA-ligand uptake and receive increased radiation dose secondary to accumulation of 177Lu-PSMA-617. This predisposes the glands to radiation-mediated toxicity. The exact mechanism, scope and severity of radiation-mediated salivary gland toxicity are not well understood, however, the strategies for its prevention and treatment are under evaluation. This review will focus on the current knowledge about salivary gland impairment post 177Lu labeled PSMA-based radioligand therapies, diagnostic methodologies, and imaging with emphasis on salivary gland scintigraphy. The preventive strategies and known treatment options would also be briefly highlighted.

2.
Clin Nucl Med ; 46(3): e168-e170, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32956127

RESUMO

ABSTRACT: A 68-year-old man with a history of prostate cancer post-primary treatment presented with rising prostate-specific antigen levels and was referred for 18F-fluciclovine PET/MRI to localize recurrent disease. PET/MRI revealed a solitary focus of uptake in a soft tissue nodule in the anterior mediastinum, which was resected and found to be a type B2 thymoma. 18F-fluciclovine uptake is mediated by amino acid transporters, primarily alanine-serine-cysteine transporter 2 and l-type amino acid transporter 1, previously demonstrated to be expressed on thymic carcinomas. This case highlights the possibility of overexpression of amino acid transporters in thymomas as well, rarely described before.


Assuntos
Ácidos Carboxílicos/metabolismo , Ciclobutanos/metabolismo , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Timoma/diagnóstico por imagem , Timoma/metabolismo , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/metabolismo , Idoso , Transporte Biológico , Humanos , Masculino , Timoma/patologia , Neoplasias do Timo/patologia
3.
Isr Med Assoc J ; 22(3): 178-184, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32147984

RESUMO

BACKGROUND: The authors reviewed the two most common current uses of brain 18F-labeled fluoro-2-deoxyglucose positron emission tomography (FDG-PET) at a large academic medical center. For epilepsy patients considering surgical management, FDG-PET can help localize epileptogenic lesions, discriminate between multiple or discordant EEG or MRI findings, and predict prognosis for post-surgical seizure control. In elderly patients with cognitive impairment, FDG-PET often demonstrates lobar-specific patterns of hypometabolism that suggest particular underlying neurodegenerative pathologies, such as Alzheimer's disease. FDG-PET of the brain can be a key diagnostic modality and contribute to improved patient care.


Assuntos
Encéfalo/diagnóstico por imagem , Demência/diagnóstico por imagem , Epilepsia/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/patologia , Demência/patologia , Epilepsia/patologia , Humanos
4.
World J Nucl Med ; 17(4): 241-248, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30505221

RESUMO

Rapidly enlarging, painful plexiform neurofibromas (PN) in neurofibromatosis type 1 (NF1) patients are at higher risk for harboring a malignant peripheral nerve sheath tumor (MPNST). Fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has been used to support more invasive diagnostic and therapeutic interventions. However, PET/CT imparts an untoward radiation hazard to this population with tumor suppressor gene impairment. The use of FDG PET coupled with magnetic resonance imaging (MRI) rather than CT is a safer alternative but its relative diagnostic sensitivity requires verification. Ten patients (6 females, 4 males, mean age 27 years, range 8-54) with NF1 and progressive PN were accrued from our institutional NF Clinic. Indications for PET scanning included increasing pain and/or progressive disability associated with an enlarging PN on serial MRIs. Following a clinically indicated whole-body FDG PET/CT, a contemporaneous PET/MRI was obtained using residual FDG activity with an average time interval of 3-4 h FDG-avid lesions were assessed for both maximum standardized uptake value (SUVmax) from PET/CT and SUVmax from PET/MR and correlation was made between the two parameters. 26 FDG avid lesions were detected on both PET/CT and PET/MR with an accuracy of 100%. SUVmax values ranged from 1.4-10.8 for PET/CT and from 0.2-5.9 for PET/MRI. SUVmax values from both modalities demonstrated positive correlation (r = 0.45, P < 0.001). PET/MRI radiation dose was significantly lower (53.35% ± 14.37% [P = 0.006]). In conclusion, PET/MRI is a feasible alternative to PET/CT in patients with NF1 when screening for the potential occurrence of MPNST. Reduction in radiation exposure approaches 50% compared to PET/CT.

5.
World J Nucl Med ; 17(3): 188-194, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30034284

RESUMO

Fluorodeoxyglucose (FDG) positron emission tomography-magnetic resonance (PET/MR) is useful for the evaluation of cognitively-impaired patients. This study aims to assess two different attenuation correction (AC) methods (Dixon-MR and atlas-based) versus index-standard computed tomography (CT) AC for the visual interpretation of regional hypometabolism in patients with cognitive impairment. Two board-certified nuclear medicine physicians blindly scored brain region FDG hypometabolism as normal versus hypometabolic using two-dimensional (2D) and 3D FDG PET/MR images generated by MIM software. Regions were quantitatively assessed as normal versus mildly, moderately, or severely hypometabolic. Hypometabolism scores obtained using the different methods of AC were compared, and interreader, as well as intra-reader agreement, was assessed. Regional hypometabolism versus normal metabolism was correctly classified in 16 patients on atlas-based and Dixon-based AC map PET reconstructions (vs. CT reference AC) for 94% (90%-96% confidence interval [CI]) and 93% (89%-96% CI) of scored regions, respectively. The averaged sensitivity/specificity for detection of any regional hypometabolism was 95%/94% (P = 0.669) and 90%/91% (P = 0.937) for atlas-based and Dixon-based AC maps. Interreader agreement for detection of regional hypometabolism was high, with similar outcome assessments when using atlas- and Dixon-corrected PET data in 93% (Κ =0.82) and 93% (Κ =0.84) of regions, respectively. Intrareader agreement for detection of regional hypometabolism was high, with concordant outcome assessments when using atlas- and Dixon-corrected data in 93%/92% (Κ =0.79) and 92/93% (Κ =0.78). Despite the quantitative advantages of atlas-based AC in brain PET/MR, routine clinical Dixon AC yields comparable visual ratings of regional hypometabolism in the evaluation of cognitively impaired patients undergoing brain PET/MR and is similar in performance to CT-based AC. Therefore, Dixon AC is acceptable for the routine clinical evaluation of dementia syndromes.

6.
Clin Nucl Med ; 42(1): e58-e60, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27775934

RESUMO

Interpretation of iodine I whole-body scintigraphy can be challenging, as there are many nonpathologic findings that may present with increased radiotracer uptake. Radiotracer uptake has been reported in the literature involving the salivary glands, thymus, renal cysts, skin contamination, and other benign etiologies. We present the case of an incidental right wrist ganglion cyst demonstrating persistent increased uptake on I whole-body scintigraphy.


Assuntos
Cistos Glanglionares/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Imagem Corporal Total , Adulto , Radioisótopos de Cobalto , Humanos , Achados Incidentais , Radioisótopos do Iodo , Imageamento por Ressonância Magnética , Masculino , Compostos Radiofarmacêuticos , Punho/diagnóstico por imagem
7.
Clin Nucl Med ; 42(1): e8-e15, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27775939

RESUMO

PURPOSE: The aim of this study was to conduct a prospective pilot study comparing the diagnostic performance of MRI alone and F-FDG simultaneous PET/MRI using a diuresis protocol in bladder cancer patients. METHODS: Twenty-two bladder cancer patients underwent F-FDG PET/MRI, using intravenous furosemide and oral hydration for bladder clearance. A radiologist scored probability of tumor in 3 locations (urinary bladder, pelvic lymph nodes, nonnodal pelvis) using 1- to 3-point scale (1 = negative, 2 = equivocal, 3 = definite tumor). A nuclear medicine physician reviewed fused PET/MRI images, after which scores were reassigned based on combined findings. Follow-up pathologic and imaging data served as reference. Performances of MRI alone and PET/MRI were compared. RESULTS: Of these patients, 82%, 38%, and 18% were positive for bladder, pelvic nodal, and nonnodal pelvic tumor, respectively. At a score of 3, PET/MRI exhibited greater accuracy for detection of bladder tumor (86% vs 77%), metastatic pelvic lymph nodes (95% vs 76%), and nonnodal pelvic malignancy (100% vs 91%). In the bladder, PET changed the level of suspicion in 36% of patients (50% increased suspicion, 50% decreased suspicion), with 75% of these changes deemed correct based on reference standard. For pelvic lymph nodes, PET changed suspicion in 52% (36% increase, 64% decrease), with 95% of changes deemed correct. For nonnodal pelvis, PET changed suspicion in 9% (100% increase), with 100% deemed correct. CONCLUSIONS: Additional PET information helped to appropriately determine level of suspicion in multiple anatomic sites for otherwise equivocal findings on MRI alone. Although requiring larger studies, findings suggest a possible role for simultaneous PET/MRI to assist bladder cancer management.


Assuntos
Carcinoma de Células de Transição/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Idoso , Carcinoma de Células de Transição/secundário , Diurese , Diuréticos , Feminino , Fluordesoxiglucose F18 , Furosemida , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Pelve/diagnóstico por imagem , Neoplasias Peritoneais/secundário , Projetos Piloto , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Neoplasias da Bexiga Urinária/patologia
8.
PET Clin ; 11(4): 387-402, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27593245

RESUMO

Hybrid imaging systems have dramatically improved thoracic oncology patient care over the past 2 decades. PET-MR imaging systems have the potential to further improve imaging of thoracic neoplasms, resulting in diagnostic and therapeutic advantages compared with current MR imaging and PET-computed tomography systems. Increasing soft tissue contrast and lesion sensitivity, improved image registration, reduced radiation exposure, and improved patient convenience are immediate clinical advantages. Multiparametric quantitative imaging capabilities of PET-MR imaging have the potential to improve understanding of the molecular mechanisms of cancer and treatment effects, potentially guiding improvements in diagnosis and therapy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Mama/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino
9.
J Nucl Med ; 57(6): 918-24, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26837338

RESUMO

UNLABELLED: Simultaneous PET/MR of the brain is a promising technology for characterizing patients with suspected cognitive impairment or epilepsy. Unlike CT, however, MR signal intensities do not correlate directly with PET photon attenuation correction (AC), and inaccurate radiotracer SUV estimation can limit future PET/MR clinical applications. We tested a novel AC method that supplements standard Dixon-based tissue segmentation with a superimposed model-based bone compartment. METHODS: We directly compared SUV estimation between MR-based AC and reference CT AC in 16 patients undergoing same-day PET/CT and PET/MR with a single (18)F-FDG dose for suspected neurodegeneration. Three Dixon-based MR AC methods were compared with CT: standard Dixon 4-compartment segmentation alone, Dixon with a superimposed model-based bone compartment, and Dixon with a superimposed bone compartment and linear AC optimized specifically for brain tissue. The brain was segmented using a 3-dimensional T1-weighted volumetric MR sequence, and SUV estimations were compared with CT AC for whole-image, whole-brain, and 91 FreeSurfer-based regions of interest. RESULTS: Modifying the linear AC value specifically for brain and superimposing a model-based bone compartment reduced the whole-brain SUV estimation bias of Dixon-based PET/MR AC by 95% compared with reference CT AC (P < 0.05), resulting in a residual -0.3% whole-brain SUVmean bias. Further, brain regional analysis demonstrated only 3 frontal lobe regions with an SUV estimation bias of 5% or greater (P < 0.05). These biases appeared to correlate with high individual variability in frontal bone thickness and pneumatization. CONCLUSION: Bone compartment and linear AC modifications result in a highly accurate MR AC method in subjects with suspected neurodegeneration. This prototype MR AC solution appears equivalent to other recently proposed solutions and does not require additional MR sequences and scanning time. These data also suggest that exclusively model-based MR AC approaches may be adversely affected by common individual variations in skull anatomy.


Assuntos
Osso e Ossos/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Fótons
10.
J Oral Maxillofac Surg ; 74(5): 945-58, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26657395

RESUMO

PURPOSE: There is considerable controversy over the treatment of medication-related osteonecrosis of the jaw (MRONJ) and growing interest and debate related to the timing, type, technique, and goals of surgical intervention. The specific aim was to evaluate the predictive value of fluorodeoxyglucose (FDG) positron emission tomography (PET) with computed tomography (CT) on healing outcomes in patients undergoing surgery for MRONJ of the mandible. MATERIALS AND METHODS: A retrospective cohort study of 31 patients with 33 MRONJ lesions of the mandible who had undergone surgery using FDG PET-CT was conducted. Data were collected on FDG uptake patterns, healing, follow-up, demographics, lesion characteristics, antiresorptive therapy, and adjunctive therapy. Panoramic and/or periapical radiographs were used to identify non-restorable teeth and PET-CT images were used to identify sequestra and FDG uptake. Above the mandibular canal, surgery consisted of marginal resection and/or debridement of clinically involved bone and exposure of clinically uninvolved bone identified by FDG uptake. Below the mandibular canal, mobile segments of bony sequestra were removed, but areas of clinically uninvolved bone with FDG uptake were not. Patients who did not heal underwent segmental resection and reconstruction with rigid fixation and a local or regional soft tissue flap or free fibular flap. The primary predictor variable was the FDG uptake pattern for each patient. The outcome variable was postoperative healing defined by mucosal closure without signs of infection or exposed bone at the time of evaluation. RESULTS: Two risk groups were identified based on FDG uptake pattern. The low-risk group, type A, included 22 patients with activity limited to the alveolus, torus, and/or basal bone superior to the mandibular canal. The high-risk group, type B, included 11 patients with type A FDG activity with extension inferior to the mandibular canal. Treatment of type A MRONJ lesions was more successful than treatment of type B MRONJ lesions (100 vs 27%; P < .001). Seven of the type B failures were successfully retreated by segmental resection and reconstruction (1 patient refused further treatment). CONCLUSION: These results showed that low-risk FDG PET-CT findings predicted successful healing with surgery above the mandibular canal. In contrast, high-risk FDG findings were associated with a greater than 50% risk of failure for treatment that extended below the mandibular canal. Although these failures suggest that FDG uptake indicates infected tissue, further research is needed to identify which high-risk patients are most likely to benefit from a conservative treatment protocol.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/patologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/cirurgia , Feminino , Fluordesoxiglucose F18/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
11.
J Magn Reson Imaging ; 43(2): 504-11, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26192731

RESUMO

PURPOSE: To assess outcomes of lung nodules missed on simultaneous positron emission tomography and magnetic resonance imaging (PET/MRI) compared to the reference standard PET and computed tomography (PET/CT) in patients with primary malignancy. MATERIALS AND METHODS: In all, 208 patients with primary malignancy undergoing clinically indicated (18F) fluorodeoxyglucose (FDG) PET/CT followed by PET/MRI were independently reviewed by two readers. Upon review of the thoracic station on PET/MRI and PET/CT, 89 non-FDG avid small lung nodules in 43 patients were detected (by reader 1) only on the CT component of the PET/CT but were not identified on PET/MRI. Overall, 84 of these 89 nodules were examined on follow-up imaging with PET/CT or chest CT. The remaining five nodules had no follow-up imaging but had remote imaging available for comparison. RESULTS: Among the 84 nodules with follow-up, three nodules (3%) in one patient progressed, 10 (12%) nodules partially/completely resolved, whereas 71 nodules (85%) remained stable. The five nodules without follow-up were all stable since prior imaging of over 21 months. CONCLUSION: The vast majority (97%) of small non-FDG avid lung nodules missed on PET/MRI either resolved or remained stable on follow-up, suggestive of benignity. PET/MRI remains a viable alternative imaging modality in oncology patients, despite its low sensitivity in detecting small lung nodules.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética , Imagem Multimodal , Avaliação de Resultados em Cuidados de Saúde , Tomografia por Emissão de Pósitrons , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Adulto Jovem
12.
J Nucl Med ; 56(7): 1061-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26025957

RESUMO

UNLABELLED: In routine whole-body PET/MR hybrid imaging, attenuation correction (AC) is usually performed by segmentation methods based on a Dixon MR sequence providing up to 4 different tissue classes. Because of the lack of bone information with the Dixon-based MR sequence, bone is currently considered as soft tissue. Thus, the aim of this study was to evaluate a novel model-based AC method that considers bone in whole-body PET/MR imaging. METHODS: The new method ("Model") is based on a regular 4-compartment segmentation from a Dixon sequence ("Dixon"). Bone information is added using a model-based bone segmentation algorithm, which includes a set of prealigned MR image and bone mask pairs for each major body bone individually. Model was quantitatively evaluated on 20 patients who underwent whole-body PET/MR imaging. As a standard of reference, CT-based µ-maps were generated for each patient individually by nonrigid registration to the MR images based on PET/CT data. This step allowed for a quantitative comparison of all µ-maps based on a single PET emission raw dataset of the PET/MR system. Volumes of interest were drawn on normal tissue, soft-tissue lesions, and bone lesions; standardized uptake values were quantitatively compared. RESULTS: In soft-tissue regions with background uptake, the average bias of SUVs in background volumes of interest was 2.4% ± 2.5% and 2.7% ± 2.7% for Dixon and Model, respectively, compared with CT-based AC. For bony tissue, the -25.5% ± 7.9% underestimation observed with Dixon was reduced to -4.9% ± 6.7% with Model. In bone lesions, the average underestimation was -7.4% ± 5.3% and -2.9% ± 5.8% for Dixon and Model, respectively. For soft-tissue lesions, the biases were 5.1% ± 5.1% for Dixon and 5.2% ± 5.2% for Model. CONCLUSION: The novel MR-based AC method for whole-body PET/MR imaging, combining Dixon-based soft-tissue segmentation and model-based bone estimation, improves PET quantification in whole-body hybrid PET/MR imaging, especially in bony tissue and nearby soft tissue.


Assuntos
Osso e Ossos/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Imagem Corporal Total , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Osso e Ossos/patologia , Feminino , Fluordesoxiglucose F18/química , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/química , Tomografia Computadorizada por Raios X
13.
Abdom Imaging ; 40(6): 1366-73, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25985966

RESUMO

Positron emission tomography (PET) and magnetic resonance imaging, until recently, have been performed on separate PET and MR systems with varying temporal delay between the two acquisitions. The interpretation of these two separately acquired studies requires cognitive fusion by radiologists/nuclear medicine physicians or dedicated and challenging post-processing. Recent advances in hardware and software with introduction of hybrid PET/MR systems have made it possible to acquire the PET and MR images simultaneously or near simultaneously. This review article serves as a road-map for clinical implementation of hybrid PET/MR systems and briefly discusses hardware systems, the personnel needs, safety and quality issues, and reimbursement topics based on experience at NYU Langone Medical Center and Cleveland Clinic.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Humanos
14.
Clin Nucl Med ; 40(8): 637-41, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25783514

RESUMO

PURPOSE: The aim of this study was to compare coregistration of the bladder wall, bladder masses, and pelvic lymph nodes between sequential and simultaneous PET and MRI acquisitions obtained during hybrid (18)F-FDG PET/MRI performed using a diuresis protocol in bladder cancer patients. METHODS: Six bladder cancer patients underwent (18)F-FDG hybrid PET/MRI, including IV Lasix administration and oral hydration, before imaging to achieve bladder clearance. Axial T2-weighted imaging (T2WI) was obtained approximately 40 minutes before PET ("sequential") and concurrently with PET ("simultaneous"). Three-dimensional spatial coordinates of the bladder wall, bladder masses, and pelvic lymph nodes were recorded for PET and T2WI. Distances between these locations on PET and T2WI sequences were computed and used to compare in-plane (x-y plane) and through-plane (z-axis) misregistration relative to PET between T2WI acquisitions. RESULTS: The bladder increased in volume between T2WI acquisitions (sequential, 176 [139] mL; simultaneous, 255 [146] mL). Four patients exhibited a bladder mass, all with increased activity (SUV, 9.5-38.4). Seven pelvic lymph nodes in 4 patients showed increased activity (SUV, 2.2-9.9). The bladder wall exhibited substantially less misregistration relative to PET for simultaneous, compared with sequential, acquisitions in in-plane (2.8 [3.1] mm vs 7.4 [9.1] mm) and through-plane (1.7 [2.2] mm vs 5.7 [9.6] mm) dimensions. Bladder masses exhibited slightly decreased misregistration for simultaneous, compared with sequential, acquisitions in in-plane (2.2 [1.4] mm vs 2.6 [1.9] mm) and through-plane (0.0 [0.0] mm vs 0.3 [0.8] mm) dimensions. FDG-avid lymph nodes exhibited slightly decreased in-plane misregistration (1.1 [0.8] mm vs 2.5 [0.6] mm), although identical through-plane misregistration (4.0 [1.9] mm vs 4.0 [2.8] mm). CONCLUSIONS: Using hybrid PET/MRI, simultaneous imaging substantially improved bladder wall coregistration and slightly improved coregistration of bladder masses and pelvic lymph nodes.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Pelve/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Neoplasias da Bexiga Urinária/diagnóstico
15.
AJR Am J Roentgenol ; 204(4): 842-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25794075

RESUMO

OBJECTIVE: The objective of our study was to assess the role of recently introduced hybrid PET/MRI in the evaluation of lymphoma patients using PET/CT as a reference standard. SUBJECTS AND METHODS: In this prospective study 28 consecutive lymphoma patients (18 men, 10 women; mean age, 53.6 years) undergoing clinically indicated PET/ CT were subsequently imaged with PET/MRI using residual FDG activity from the PET/ CT study. Blinded readers evaluated PET/CT (reference standard), PET/MRI, and diffusion-weighted imaging (DWI) studies separately; for each study, they assessed nodal and extranodal involvement. Each FDG-avid nodal station was marked and compared on DWI, PET/MRI, and PET/CT. Modified Ann Arbor staging was performed and compared between PET/MRI and PET/CT. The maximum standardized uptake value (SUVmax) on PET/MRI for FDG-avid nodal lesions was compared with the SUVmax on PET/CT. The apparent diffusion coefficient (ADC) for FDG-avid nodal lesions was compared to SUVmax on PET/MRI. RESULTS: Fifty-one FDG-avid nodal groups were identified on PET/CT in 13 patients. PET/MRI identified 51 of these nodal groups with a sensitivity of 100%. DWI identified 32 nodal groups for a sensitivity of 62.7%. PET/MRI staging and PET/CT staging were concordant in 96.4% of patients. For the one patient with discordant staging results, disease was correctly upstaged to stage IV on the basis of the PET/MRI finding of bone marrow involvement, which was missed on PET/CT. DWI staging was concordant with PET/CT staging in 64.3% of the patients. The increased staging accuracy of PET/MRI relative to DWI was significant (p=0.004). SUVmax measured on PET/MRI and PET/CT showed excellent statistically significant correlation (r=0.98, p<0.001). There was a poor negative correlation between ADC and SUVmax (r=-0.036, p=0.847). CONCLUSION: PET/MRI can be used to assess disease burden in lymphoma with sensitivity similar to PET/CT and can be a viable alternative for lymphoma staging and follow-up.


Assuntos
Linfoma/diagnóstico , Imageamento por Ressonância Magnética , Imagem Multimodal , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Interpretação de Imagem Assistida por Computador , Linfoma/patologia , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
16.
Clin Nucl Med ; 40(3): 258-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25290291

RESUMO

A 78-year-old man with metastatic malignant melanoma underwent a restaging 18F-FDG PET/CT after initiation of ipilimumab therapy, a Food and Drug Administration-approved human monoclonal antibody targeting CTLA-4. PET/CT demonstrated intense FDG uptake fusing to poorly circumscribed hypodensities throughout the liver. Patient was experiencing high-grade fever, chills, and generalized fatigue at the time of imaging, as well as mildly elevated liver function tests. Patient was subsequently treated with corticosteroids for suspected ipilimumab-induced hepatitis, and the patient rapidly improved clinically. Follow-up PET/CT 2 months later revealed complete resolution of abnormal FDG uptake in the liver, confirming the diagnosis of ipilimumab-induced hepatitis.


Assuntos
Anticorpos Monoclonais/efeitos adversos , Hepatite/diagnóstico por imagem , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Idoso , Anticorpos Monoclonais/uso terapêutico , Fluordesoxiglucose F18 , Hepatite/etiologia , Humanos , Ipilimumab , Masculino , Melanoma/tratamento farmacológico , Imagem Multimodal , Compostos Radiofarmacêuticos
17.
J Oral Maxillofac Surg ; 72(10): 1957-65, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25053572

RESUMO

PURPOSE: Imaging is important to identify subclinical changes and for treatment planning in patients with osteonecrosis of the jaw (ONJ) exposed to antiresorptive therapy. The aim of this study was to compare the findings at radiography with those at fluorodeoxyglucose (FDG) positron emission tomography (PET) with computed tomography (CT) for patients with ONJ related to antiresorptive therapy. MATERIALS AND METHODS: A cross-sectional retrospective analysis of patients with clinically identified ONJ lesions of the mandible was performed. Two imaging modalities were evaluated for each patient: plain radiography (ie, panoramic or periapical) and FDG PET/CT with 1-mm sections. Outcome variables for the radiographic findings were osteolytic and osteosclerotic bone changes. Outcome variables for FDG PET/CT images were localization of FDG uptake. Maximum standard uptake values (SUVmax) of abnormal FDG jaw uptake were recorded, in addition to the mean SUV of the contralateral normal mandible, and used to calculate the target-to-background ratio. Radiographic changes and FDG uptake were classified as local (ie, corresponding to exposed cortical bone) or diffuse (ie, local changes and changes extending beyond the margins of exposed bone) for each imaging technique. Local and diffuse changes detected by each imaging modality were described and the difference in detection was compared with the McNemar test. RESULTS: Twenty-three patients with 25 clinically identified ONJ lesions were analyzed using radiography and FDG PET/CT. Differences were found in how radiography and FDG PET/CT detect local and diffuse changes associated with ONJ. Radiography showed local changes in 17 patients (68%), diffuse changes in 3 patients (12%), and no changes in 5 patients (20%), whereas FDG PET/CT imaging showed local changes in 17 patients (68%) and diffuse changes in 8 patients (32%). The McNemar test indicated that FDG PET/CT imaging was less likely to miss a lesion (P < .001). Mean SUVmax was 6.59, and the mean target-to-background ratio was 5.37. CONCLUSION: The results of this study show that FDG PET/CT detects local and diffuse metabolic changes that may not be represented by plain radiography for patients with ONJ related to antiresorptive therapy. The target-to-background ratio allowed the discrimination between ONJ lesions and background changes. Future studies are necessary to determine whether FDG PET/CT can determine risk and facilitate management of ONJ.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Fluordesoxiglucose F18 , Doenças Mandibulares/induzido quimicamente , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Conservadores da Densidade Óssea/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Estudos Transversais , Difosfonatos/efeitos adversos , Feminino , Humanos , Imidazóis/efeitos adversos , Masculino , Mandíbula/diagnóstico por imagem , Doenças Mandibulares/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia Interproximal/métodos , Radiografia Panorâmica/métodos , Estudos Retrospectivos , Extração Dentária , Ácido Zoledrônico
18.
PET Clin ; 9(2): 237-52, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25030285

RESUMO

Simultaneous positron emission tomography (PET)/magnetic resonance (MR) imaging is a promising novel technology for oncology diagnosis and staging and neurologic and cardiac applications. Our institution's current research protocol results in a total imaging time of approximately 45 to 70 minutes with simultaneous PET/MR imaging, making this a feasible total body imaging protocol. Further development of MR-based attenuation correction will improve PET quantification. Quantitatively accurate multiparametric PET/MR data sets will likely improve diagnosis of disease and help guide and monitor the therapies for individualized patient care.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/tendências , Imagem Multimodal/tendências , Tomografia por Emissão de Pósitrons/tendências , Compostos Radiofarmacêuticos , Desenho de Equipamento/tendências , Previsões , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagem Multimodal/instrumentação , Neoplasias/diagnóstico , Doenças do Sistema Nervoso/diagnóstico , Tomografia por Emissão de Pósitrons/instrumentação , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador , Fatores de Risco
20.
AJR Am J Roentgenol ; 201(5): 1115-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147485

RESUMO

OBJECTIVE: The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. SUBJECTS AND METHODS: Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. RESULTS: Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation Criteria in Solid Tumors 1.1. The ratio between SUVmax and ADCmin was higher among patients with progressive disease than those with a partial treatment response. CONCLUSION: Simultaneous PET/MRI is a promising technology for the detection of neoplastic disease. There are inverse correlations between SUVmax and ADCmin and between SUV ratio and ADCmin. Correlation coefficients between SUVmax and ADCmin from PET/MRI were similar to values obtained with SUVmax from the same-day PET/CT. Given that both SUV and ADC are related to malignancy and that the correlation between the two biomarkers is relatively weak, SUV and ADC values may offer complementary information to aid in determination of prognosis and treatment response. The combined tumoral biomarker, ratio between SUVmax and ADCmin, may be useful for assessing progressive disease versus partial treatment response.


Assuntos
Imagem Multimodal , Neoplasias/diagnóstico , Imagem Corporal Total , Idoso , Imagem de Difusão por Ressonância Magnética , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA