Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neurosurg Spine ; 13(1): 5-16, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20594011

RESUMO

OBJECT Numerous techniques have been historically used for occipitocervical fusion with varied results. The purpose of this study was to examine outcomes of various surgical techniques used in patients with various disease states to elucidate the most efficacious method of stabilization of the occipitocervical junction. METHODS A literature search of peer-reviewed articles was performed using PubMed and CINAHL/Ovid. The key words "occipitocervical fusion," "occipitocervical fixation," "cervical instrumentation," and "occipitocervical instrumentation" were used to search for relevant articles. Thirty-four studies were identified that met the search criteria. Within these studies, 799 adult patients who underwent posterior occipitocervical fusion were analyzed for radiographic and clinical outcomes including fusion rate, time to fusion, neurological outcomes, and the rate of adverse events. RESULTS No articles stronger than Class IV were identified in the literature. Among the patients identified within the cited articles, the use of posterior screw/rod instrumentation constructs were associated with a lower rate of postoperative adverse events (33.33%) (p < 0.0001), lower rates of instrumentation failure (7.89%) (p < 0.0001), and improved neurological outcomes (81.58%) (p < 0.0001) when compared with posterior wiring/rod, screw/plate, and onlay in situ bone grafting techniques. The surgical technique associated with the highest fusion rate was posterior wiring and rods (95.9%) (p = 0.0484), which also demonstrated the shortest fusion time (p < 0.0064). Screw/rod techniques also had a high fusion rate, fusing in 93.02% of cases. When comparing outcomes of surgical techniques depending on the disease status, inflammatory diseases had the lowest rate of instrumentation failure (0%) and the highest rate of neurological improvement (90.91%) following the use of screw/rod techniques. Occipitocervical fusion performed for the treatment of tumors by using screw/rod techniques had the lowest fusion rate (57.14%) (p = 0.0089). Traumatic causes of occipitocervical instability had the highest percentage of pain improvement with the use of screw/plates (100% improvement) (p < 0.0001). CONCLUSIONS Based on the existing literature, techniques that use screw/rod constructs in occipitocervical fusion are associated with very favorable outcomes in all categories assessed for all disease processes. For patients requiring occipitocervical arthrodesis for the treatment of inflammatory diseases, screw/rod constructs are associated with the most favorable outcomes, while posterior wiring and onlay in situ bone grafting is associated with the least favorable outcomes. Occipitocervical arthrodesis performed for the diagnosis of tumor is associated with the lowest rate of successful arthrodesis using screw/rod techniques, while posterior wiring and rods have the highest rate of arthrodesis. The nonspecified disease group had the lowest rate of surgical adverse events and the highest rate of neurological improvement.


Assuntos
Vértebras Cervicais/cirurgia , Osso Occipital/cirurgia , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos , Transplante Ósseo/métodos , Distribuição de Qui-Quadrado , Humanos , Fixadores Internos , Fusão Vertebral/instrumentação , Resultado do Tratamento
3.
Int Orthop ; 31(6): 735-41, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17962946

RESUMO

Since the identification of the osteogenic protein-1 (OP-1) gene, also called bone morphogenetic protein-7 (BMP-7), almost 20 years ago, OP-1 has become one of the most characteristic members of the BMP family. The biological activity of recombinant human OP-1 has been defined using a variety of animal models. These studies have demonstrated that local implantation of OP-1 in combination with a collagen matrix results in the repair of critical size defects in long bones and in craniofacial bones and the formation of bony fusion masses in spinal fusions. Clinical trials investigating long bone applications have provided supportive evidence for the use of OP-1 in the treatment of open tibial fractures, distal tibial fractures, tibial nonunions, scaphoid nonunions and atrophic long bone nonunions. Clinical studies investigating spinal fusion applications have provided supportive evidence for the use of OP-1 in posterolateral lumbar models and compromised patients as an adjunct or as a replacement for autograft. Both long bone repair and spinal fusion studies have demonstrated the efficacy and safety of OP-1 by clinical outcomes and radiographic measures. Future clinical investigations will be needed to better define variables, such as dose, scaffold and route of administration. Clearly the use of BMPs in orthopaedics is still in its formative stage, but the data suggest an exciting and promising future for the development of new therapeutic applications.


Assuntos
Proteínas Morfogenéticas Ósseas/uso terapêutico , Fraturas Ósseas/tratamento farmacológico , Fraturas não Consolidadas/tratamento farmacológico , Fator de Crescimento Transformador beta/uso terapêutico , Proteína Morfogenética Óssea 7 , Transplante Ósseo/métodos , Humanos , Procedimentos Ortopédicos/métodos , Fusão Vertebral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA