1.
Ophthalmology ; 108(11): 1999-2004, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11713068

RESUMO

OBJECTIVE: To investigate the cause of severe central opacification in 41 foldable acrylic intraocular lenses (IOLs) requiring explantation. Another IOL was opacified in the original sealed vial. DESIGN: Case series and laboratory analysis. TESTING: Light microscopy, high performance liquid chromatography, sodium dodecyl sulfate polyacoylamide gel electrophoresis, spectrometric analysis, and autoclaving. RESULTS: Neither fatty acids nor proteins could be identified within the IOLs. Spectrometric analysis yielded absorption peaks in the ultraviolet spectral range. CONCLUSIONS: The spectroscopic findings indicate premature aging of the ultraviolet blocking agent. The source of the opacification is a change in the IOL material itself.


Assuntos
Resinas Acrílicas , Lentes Intraoculares , Falha de Prótese , Resinas Acrílicas/química , Idoso , Cromatografia Líquida de Alta Pressão , Remoção de Dispositivo , Eletroforese em Gel de Poliacrilamida , Proteínas do Olho/análise , Ácidos Graxos/análise , Feminino , Humanos , Masculino
2.
Ophthalmic Res ; 33(6): 303-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11721181

RESUMO

PURPOSE: It is of major interest to understand how intraocular lens (IOL) surfaces interact with aqueous humor or tissues after implantation. Important parameters to describe the physicochemical surface properties are the contact angle and critical surface tension. Therefore, we performed measurements of the contact angle and critical surface tension of several commercially available IOLs. SETTING: Department of Ophthalmology, Johannes Gutenberg University, Mainz, University Eye Hospital, Tübingen, and Max Planck Institute for Polymer Research, Mainz, Germany. METHODS: A total of 17 commercially available standard quality IOL types (6 of each) of different materials from several manufacturers were studied. Scanning electron microscopy and contact angle measurements using the sessile drop method were made. RESULTS: The sessile drop method differentiated all materials based on their surface forces. The contact angle (mean +/- SD) ranged from 56.5 +/- 3.8b 3. CONCLUSION: Contact angles differed between the IOLs depending on the IOL material with the lowest contact angle in the heparin-surface-modified IOL. The contact angle measurement method generates useful information about the material surface and its potential biomaterial interactions.


Assuntos
Lentes Intraoculares , Tensão Superficial , Resinas Acrílicas , Materiais Revestidos Biocompatíveis , Heparina , Polimetil Metacrilato , Elastômeros de Silicone
3.
J Cataract Refract Surg ; 27(7): 994-9, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11489566

RESUMO

We describe a simple method to assign a diagnosis of cataract to patients with obscurely impaired vision as well as to those with mild lens opacities. When the narrowest slit is used in a slitlamp examination, a small beam of light appears on the macula. Routine fundoscopy with the 78.0 diopter lens or a 3-mirror glass is appropriate. If a cataract is present, the beam of light is scattered into several straight lines, distorted lines, or both. This has proved a useful diagnostic tool when the lens appears clear but the patient's vision is impaired, and extensive examinations such as computer tomography or nuclear magnetic resonance tomography for impaired vision may be avoided. The beam-deflection method uses devices that are generally available and can detect cataract in the early stages of development.


Assuntos
Catarata/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Transtornos da Visão/diagnóstico , Adolescente , Adulto , Idoso , Catarata/complicações , Criança , Pré-Escolar , Feminino , Humanos , Cristalino/patologia , Luz , Masculino , Pessoa de Meia-Idade , Transtornos da Visão/etiologia , Acuidade Visual
4.
J Cataract Refract Surg ; 26(2): 282-6, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10683799

RESUMO

PURPOSE: To study the propagation of ultrasonic shock waves in viscoelastic agents and the resulting corneal load. SETTING: University Siegen, Institute for Mechanics and Control Engineering, Siegen, Germany. METHODS: The anterior chamber of a manufactured artificial eye was constructed according to anatomic dimensions. Three openings were drilled--for the phaco tip, for the exchange of a viscoelastic agent or water, and for the shock-wave sensor. The sensor was fixed to the area corresponding to the corneal apex. The sensor signal was analyzed using a direct oscilloscope that measured the amplitude reaching the corneal apex. Shock-wave propagation in several viscoelastic agents was compared with that in balanced salt solution. RESULTS: In hydroxypropyl methylcellulose, the shock wave was amplified or influenced slightly. In hyaluronic-acid preparations, acoustic dampening occurred. CONCLUSION: Removal of hyaluronic-acid derivatives prior to phacoemulsification is not necessary.


Assuntos
Câmara Anterior/diagnóstico por imagem , Sulfatos de Condroitina/química , Ácido Hialurônico/química , Metilcelulose/análogos & derivados , Modelos Anatômicos , Facoemulsificação , Ultrassom , Temperatura Corporal , Humanos , Derivados da Hipromelose , Injeções , Metilcelulose/química , Ultrassonografia
5.
J Cataract Refract Surg ; 25(12): 1675-8, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10609215

RESUMO

A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 -3.0 x 90) and BCVA remained stable for 7 months. No significant IOL rotation was observed. Implantation of a toric PMMA IOL corrected high corneal astigmatism. Toric IOL technology with high cylindrical power allows enhancement of IOL surgery.


Assuntos
Astigmatismo/cirurgia , Córnea/cirurgia , Implante de Lente Intraocular , Facoemulsificação , Polimetil Metacrilato , Astigmatismo/complicações , Astigmatismo/patologia , Catarata/complicações , Córnea/patologia , Topografia da Córnea , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Refração Ocular , Acuidade Visual
6.
Ophthalmologica ; 212(4): 228-30, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9672209

RESUMO

In ocular surgery complications can occur from eye movements during topical anesthesia or insufficient retrobulbar anesthesia. To minimize eye movements during surgery a fixation light was designed consisting of a diode array embedded in an eye patch, and a keyboard, which will be positioned on the patient's thorax. The patient focuses with the unoperated eye at a flashing diode which is part of the diode array. The operated eye is guided by conjugated eye movements. With the keyboard, the surgeon can change the diode signal all over the array. As a result, the eye is kept still or moved in the appropriate direction to facilitate the surgical process. The flat and lightweight design of the device enables its use under sterile surgical covers or in an upright position of the patient during laser applications.


Assuntos
Movimentos Oculares , Fixação Ocular , Procedimentos Cirúrgicos Oftalmológicos/métodos , Estimulação Luminosa/instrumentação , Privação Sensorial , Anestesia Local , Desenho de Equipamento , Humanos , Terapia Assistida por Computador
7.
Klin Monbl Augenheilkd ; 213(5): 309-11, 1998 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-9888137

RESUMO

BACKGROUND: After a cataract surgery procedure with vitreous loss a vitreous strand remained in the wound. An unusual visual impairment was observed. PATIENT: A shift in refraction depending on the pupillary diameter was observed. In miosis the refraction was estimated to +1.0 sph, in mydriasis -1.0 sph/ -0.5 cyl, respectively. METHOD: We presumed that the vitreous strand between the iris and the intraocular lens caused an axial displacement of the IOL during the change from miosis to mydriasis and v.v. Therefore the vitreous strand was surgically eliminated. After surgery the refractive changes by pupillary actions were overcome. In a computer simulation (ray tracing), the amount of axial displacement of the IOL was estimated to 1.5 mm. CONCLUSION: This paper reminds of considering other reasons for loss of VA than CME, e.g. axial displacement of IOL. An adequate method of examination is the measurement of refraction in miosis and mydriasis.


Assuntos
Lentes Intraoculares , Acuidade Visual/fisiologia , Idoso , Extração de Catarata/efeitos adversos , Diagnóstico Diferencial , Feminino , Humanos , Miose/diagnóstico , Midríase/diagnóstico , Ruptura/diagnóstico , Ruptura/fisiopatologia , Corpo Vítreo/fisiopatologia
8.
Klin Monbl Augenheilkd ; 208(6): 472-6, 1996 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-8965466

RESUMO

PURPOSE: A computer program developed by the authors allows to calculate the path of light rays coming from an object through all the refractive surfaces of a Gullstrand model eye until it reaches the retina. METHOD: The program calculates several hundred light rays for every point of a given object. A menue allows to modify optical and morphological parameters in an interactive way. For instance, the indices of refraction, the radii of the cornea and of the cristalline lens, as well as the length of the bulbus can be modified. Further, one can add seeing aids such as eye glasses or a contact lens, or implant an artificial intraocular lens. The seeing aids may be decentered and/or tilted. RESULTS: The code calculates also the visual impression by projecting the image from the retina back to a screen at the distance of the object, where the human brain "sees" the object. For image interpretation we use a normal Gullstrand eye with a very small aperture stop. In this way we can simulate the visual mapping (visual impression) of a corrected or uncorrected ametropia. CONCLUSIONS: In this paper we present two nontrivial examples: we calculate the regional polyopia ("Bildverdoppelung") and the annular scotoma which appear whenever a high myopia or aphakia are corrected by eye glasses.


Assuntos
Simulação por Computador , Refração Ocular , Erros de Refração/fisiopatologia , Retina/fisiopatologia , Software , Percepção Visual/fisiologia , Lentes de Contato , Óculos , Humanos , Lentes Intraoculares , Óptica e Fotônica , Valores de Referência
9.
Ger J Ophthalmol ; 5(2): 118-25, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8741157

RESUMO

Ray tracing with a personal computer allows realistic simulation of optical properties of the human eye. Patterns of point sources are used as objects. The path of light rays is calculated between the point source and the retina for a Gullstrand eye model with improved parameters; the normal eye model has a resolution limit close to the natural resolution limit of the human eye. The image formed on the retina is projected back to a screen at the distance of the object so as to simulate image interpretation by the brain. Refractive errors are modeled by a change in eye parameters and corrected by eyeglasses or/and contact lenses or by an artificial intraocular lens. For optic correction the parameters of seeing aids can be fitted automatically by a least-squares routine. The effect of faulty eye correction on image quality is visualized by using a photograph of a realistic scene as an object.


Assuntos
Simulação por Computador , Olho/fisiopatologia , Luz , Modelos Biológicos , Oftalmologia/métodos , Afacia/fisiopatologia , Afacia/terapia , Lentes de Contato , Olho/efeitos da radiação , Óculos , Humanos , Lentes Intraoculares , Microcomputadores , Miopia/fisiopatologia , Fenômenos Fisiológicos Oculares , Valores de Referência
10.
Klin Monbl Augenheilkd ; 206(4): 277-8, 1995 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-7791291

RESUMO

A 22 year-old-man and owner of several tarantulas visited his ophthalmologist because of red itchy eyes. Additionally to kerato-conjunctivitis epidemica, uncommon hairs were found especially in his left cornea. Corrected visual acuity was 0.8. According to literature these spider hairs can induce granulomas in the meaning of ophthalmia nodosa, and even migrate inside the eye. Therefore we removed as many hairs as possible, but we left two, not to cause iatrogen perforation. The penetration depth was measured by laser tomography. Local steroids successfully prevented further granuloma formation. Regular ophthalmological controls are important to early detect possible changes, and if necessary to remove these hairs even from deeper corneal layers, in case by keratectomy.


Assuntos
Córnea , Corpos Estranhos no Olho/diagnóstico , Cabelo , Ceratoconjuntivite/etiologia , Aranhas , Adulto , Animais , Corpos Estranhos no Olho/complicações , Corpos Estranhos no Olho/terapia , Granuloma de Corpo Estranho/complicações , Granuloma de Corpo Estranho/diagnóstico , Granuloma de Corpo Estranho/terapia , Humanos , Ceratoconjuntivite/terapia , Masculino
11.
Ophthalmologe ; 90(1): 58-61, 1993 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-8443451

RESUMO

If the sap of Euphorbia inadvertently gets in the eye, it can cause conjunctivitis, keratitis or iritis. Therapy consists of rinsing, antibiotics, steroids and mydriatics when the anterior chamber is inflamed. It may also be necessary to protect the damaged eye from light, because photoallergic reactions are possible.


Assuntos
Queimaduras Químicas/etiologia , Queimaduras Oculares/induzido quimicamente , Intoxicação por Plantas/etiologia , Plantas Tóxicas , Queimaduras Químicas/terapia , Terapia Combinada , Queimaduras Oculares/terapia , Humanos , Ceratite/induzido quimicamente , Ceratite/terapia , Masculino , Pessoa de Meia-Idade , Intoxicação por Plantas/terapia
12.
Ophthalmic Surg ; 23(4): 233-7, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1589191

RESUMO

Long-term intraocular pressure (IOP) was evaluated in 41 glaucoma patients after extracapsular cataract extraction (ECCE) with posterior chamber lens (PC-IOL) implantation. All patients were initially monitored for a mean of 19 days. Eight failed to return for reexamination, but follow up of the other 33 continued for a mean of 12 months. IOP dropped significantly and the need for medication was reduced in all patients (particularly in those with open-angle glaucoma and prior iridotomy and iris suturing). The reduction in pressure remained significant in patients with simple or exfoliation glaucoma even after long-term observation. Pressure also significantly dropped in patients who had undergone previous ophthalmic surgery. The pressure drop was possibly due to a surgical deepening of the chamber angle. (Using the laser tomographic scanner, we found the same phenomenon in 50 patients without glaucoma: following ECCE/PC-IOL, the anterior chamber angle widened 9.3 +/- 4.3 degrees.)


Assuntos
Câmara Anterior/patologia , Extração de Catarata , Pressão Intraocular , Lentes Intraoculares , Idoso , Câmara Anterior/fisiopatologia , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Estudos Longitudinais , Masculino , Estudos Retrospectivos
13.
Klin Monbl Augenheilkd ; 199(1): 22-4, 1991 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-1895735

RESUMO

In order to verify reproducibility and validity of confocal measurements of the cornea we examined a well known biological model: Increasing corneal thickness under hypoxic conditions during contact lens wear. The method verified increasing thickness with high significance. In addition, reproducibility was determined within a range of 5 mu. As a result, confocal measurements proof to be a powerful tool for topographical reconstruction of corneal shape.


Assuntos
Lentes de Contato , Substância Própria/patologia , Lasers , Tomografia/instrumentação , Algoritmos , Ritmo Circadiano/fisiologia , Feminino , Humanos , Masculino , Miopia/patologia , Miopia/terapia
14.
Fortschr Ophthalmol ; 88(3): 266-70, 1991.
Artigo em Alemão | MEDLINE | ID: mdl-1889776

RESUMO

With a scanning laser ophthalmoscope (SLO), a hexagonal reflex phenomenon can be observed, which originates from the tear film and corneal tissue layers. Time motion analysis verifies that it is possible to discriminate between the cornea and tear film.


Assuntos
Doenças da Córnea/patologia , Processamento de Imagem Assistida por Computador/instrumentação , Lasers , Oftalmoscópios , Córnea/patologia , Humanos
15.
Fortschr Ophthalmol ; 88(6): 865-9, 1991.
Artigo em Alemão | MEDLINE | ID: mdl-1794823

RESUMO

After local application of pilocarpine (minimum 1%), timolol (0.5%) or levobunolol (0.5%) to 6 patients, cell differentiation of the conjunctival epithelium was compared to that in 48 healthy persons. The least difference was found after pilocarpine application. The five ultrastructurally defined cell types were found to vary least when compared to the same cell types in normal subjects. The patients treated with timolol and levobunolol showed a reduction in secretory epithelial cells, especially within the conjunctiva bulbi, and a pronounced increase in cells with rough endoplasmatic reticulum. In addition to a loss of desmosomes and zonulae occludentes on the cell surface, a minimum 1-year application of the three antiglaucomatous medications leads to a reduction in the microvilli and microplicae and, particularly in patients treated with beta blockers, to intracellular changes, specifically increased vacuolization and dilation of the rough endoplasmatic reticulum. The latter may be attributable to the action of benzalkonium chloride (present as a preservative in all three eye drops studied) on the superficial epithelial cells. The cytotoxic action of the preservative may be intensified by the simultaneous application of beta blockers due to their destabilizing effect on the tear film.


Assuntos
Diferenciação Celular/efeitos dos fármacos , Túnica Conjuntiva/efeitos dos fármacos , Glaucoma/tratamento farmacológico , Pilocarpina/efeitos adversos , Túnica Conjuntiva/patologia , Glaucoma/patologia , Humanos , Microscopia Eletrônica , Soluções Oftálmicas , Pilocarpina/administração & dosagem
16.
Appl Opt ; 30(33): 4930-5, 1991 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-20717299

RESUMO

A special sizing technique is applied to measuring the diameter of monosized droplet streams that are used for investigation of fuel droplets in enginelike conditions. For these experiments the droplet diameter must be known precisely. The sizing technique used is based on the evaluation of the fringe spacing of scattered light in the forward direction. This technique is independent of the intensity of the incident light. No absolute intensities need to be measured. The droplets are exposed to a focused laser beam. Therefore the frequently used assumption of plane wave fronts is not fulfilled. Elaborate experiments have been carried out to study the influence of a Gaussian intensity distribution of the laser beam on the accuracy of the sizing technique. It has been shown that the droplet diameter can be measured to an accuracy of better than 2% even if the droplet is illuminated by a Gaussian beam for a droplet diameter that is smaller than the beam diameter.

17.
Appl Opt ; 30(33): 4960-5, 1991 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-20717302

RESUMO

For many optical methods in liquid particle sizing the refractive index of the liquid must be known. There is no problem if the data are available in the literature. If the liquid is unknown or if the refractive index changes because of a heating process or chemical reactions, the refractive index must be measured to achieve accurate sizing. A method is presented to determine the real part of the refractive index of droplets using the shift in the position of the first rainbow. Results from the application of this method to burning droplet streams are presented.

18.
Klin Monbl Augenheilkd ; 197(5): 432-5, 1990 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-2290301

RESUMO

The Hyperimmunoglobulinemia-E-Syndrome (HIE) is characterized by high levels of serum-IgE, diminished counts of T-suppressor-cells, eosinophilia, and disturbed chemotactic functions of neutrophil granulocytes. An 8 years old female, suffering from hyperimmunoglobulinemia E (HIE), showed marginal corneal ulcera since five years. Positive conjunctival smears included several bacterias and chlamydia, but never local herpes virus. Inspite of treatment by antibiotics, virostatica, and therapeutical contact lens, a spontaneous corneal perforation occurred. A penetrating keratoplasty was successful for a short time, but soon ulceration rose again. At last a second penetrating keratoplasty was necessary. The early status showed tidy results, but some weeks later marginal ulceration occurred again. There was no clinical proof for herpetical genesis of the course, but evidence is conceivable for pathomechanisms similar to conjunctivitis vernalis.


Assuntos
Úlcera da Córnea/diagnóstico , Hipergamaglobulinemia/diagnóstico , Imunoglobulina E/análise , Criança , Transplante de Córnea/imunologia , Úlcera da Córnea/imunologia , Úlcera da Córnea/cirurgia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Hipergamaglobulinemia/imunologia , Hipergamaglobulinemia/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/imunologia , Recidiva
19.
Fortschr Ophthalmol ; 87(2): 158-67, 1990.
Artigo em Alemão | MEDLINE | ID: mdl-2192974

RESUMO

The current state of the art for the major laser scanning methods, laser scanning ophthalmoscopy (LSO) and laser tomographic scanning (LTS) is discussed and the function principles are described. Experience with a prototype of each instrument from Rodenstock (LSO) and Heidelberg Instruments (LTS) is reported. LSO imaging of the cornea, vitreous, retina, and optic disc, as well as on-line processing is demonstrated with examples (nerve fibre colour coding and histograms). Measurement of the cornea, optic disc and retinal topography with LTS is also demonstrated with examples. An example of polarization optical imaging of the cornea's assumed interferometric "tension patterns" is shown. The current status and future possibilities of laser scanning, its expanded diagnostic potential with microperimetry, IR scanning angiography and polarization optic imaging and measurement (eg. nerve fibre thickness) is discussed extensively. The safety aspects of laser light exposure of the macula are also mentioned. Laser scanners as imaging and measuring sensors of unknown accuracy open a new area of possibly revolutionary diagnostic possibilities.


Assuntos
Oftalmopatias/diagnóstico , Processamento de Imagem Assistida por Computador/instrumentação , Lasers , Oftalmoscópios , Gravação em Vídeo/instrumentação , Córnea/patologia , Humanos , Lentes , Disco Óptico/patologia , Retina/patologia , Ultrassonografia/instrumentação , Testes de Campo Visual/instrumentação , Corpo Vítreo/patologia
20.
Fortschr Ophthalmol ; 87(2): 168-70, 1990.
Artigo em Alemão | MEDLINE | ID: mdl-2358273

RESUMO

The laser scanning ophthalmoscope offers tissue examination and support of papillometrical evaluations as a result of different forms of illumination. Confocal, mixed, and Tyndall light are used in the differential diagnosis and identification of the scleral rim. With highpower mixed light under miotic conditions, imaging of the excavation is possible.


Assuntos
Lasers , Oftalmoscópios , Disco Óptico/patologia , Glaucoma/patologia , Humanos , Nervo Óptico/patologia , Papiledema/patologia