Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
BJR Case Rep ; 5(2): 20180105, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31501706

RESUMO

Choledochal cyst is a dilation of the intrahepatic and/or extrahepatic biliary tree. The pathogenesis is unknown and potentially is multifactorial. In 1977, Todani classified the cysts under five different types according to their morphology, number and distribution along the biliary tree. Presenting symptoms of Choledocal cysts which include upper abdominal pain, acute cholangitis and jaundice, although often they are clinically silent and discovered as an incidental finding. Biliary complications include cholangitis, biliary stones, pancreatitis, portal hypertension and cholangiocarcinoma. We describe a case of a rare Type II Todani cyst located on the right side of the common hepatic duct characterised by a clinical presentation similar to that observed in Mirizzi Syndrome. The treatment of a Type II choledochal cyst consists in cystic excision.

2.
Radiol Case Rep ; 14(2): 156-159, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30405867

RESUMO

The objective of this study was to describe a case of marked hypoplasia of the right renal vein with drainage into ipsilateral gonadal vein. A 66-year-old man, known for hypertension and previous smoking, underwent an abdominal ultrasound exam, which detected a juxtarenal aortic aneurysm. Computed tomography scan confirmed the presence of the aortic aneurysm; furthermore it showed an abnormal right kidney venous drainage consistent in a dilated and tortuous vein, which originated at the hilar region, heading caudally and joining the right spermatic vein at level of aortic carrefour. A thin vein-located more cranially with mild and late contrast enhancement-was also demonstrated from right kidney hilum to inferior vena cava, probably representing a remnant of the right main renal vein. To our knowledge, this anatomic variant was never reported in the peer-reviewed literature.

3.
Radiol Med ; 123(12): 891-903, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30039378

RESUMO

PURPOSE: To determine the accuracy of MDCT in the evaluation of blunt surgically relevant bowel and/or mesenteric injuries (BMIs) using single specific CT signs together with specific pairs of nonspecific signs. METHODS: Fifty-four patients examined with MDCT were divided into two groups: a 'surgical' group of 20 patients-which underwent surgery for blunt BMIs-and a control group of 34 'nonsurgical' trauma patients. Two radiologists with different experience performed a double-blind retrospective evaluation of the images, classifying the patients in the two groups by using only single specific signs; then, the images were reviewed in consensus with a third radiologist and sensitivity and specificity were calculated. Subsequently, the frequency of every single sign and of every possible combination of nonspecific signs in the two groups was registered, to find combinations present only in the surgical group; sensitivity and specificity were calculated by using even those specific combinations. RESULTS: At the first consensual evaluation, sensitivity and specificity were 75 and 100%, respectively. Two combinations of nonspecific signs (focal wall thickening + extraluminal air; focal wall thickening + seat belt sign) were found only in surgical patients that did not present any single specific sign: Sensitivity calculated adding those two combinations was 95%, without a decrease in specificity. CONCLUSIONS: MDCT is an accurate technique in the evaluation of blunt surgically relevant BMIs. The single specific CT signs were sufficient for the diagnosis in only 75% of the cases; adding the two specific combinations allowed an increase in sensitivity of 20%.


Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Intestinos/lesões , Mesentério/lesões , Tomografia Computadorizada Multidetectores/métodos , Ferimentos não Penetrantes/diagnóstico por imagem , Traumatismos Abdominais/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Método Duplo-Cego , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Ferimentos não Penetrantes/cirurgia
4.
Abdom Radiol (NY) ; 43(11): 2903-2912, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29541831

RESUMO

PURPOSE: To evaluate whether the addition of gadolinium-enhanced MRI and diffusion-weighted imaging (DWI) improves T2 sequence performance for the diagnosis of local recurrence (LR) from rectal cancer and to assess which approach is better at formulating this diagnosis among readers with different experience. METHODS: Forty-three patients with suspected LR underwent pelvic MRI with T2 weighted (T2) sequences, gadolinium fat-suppressed T1 weighted sequences (post-contrast T1), and DWI sequences. Three readers (expert: G, intermediate: E, resident: V) scored the likelihood of LR on T2, T2 + post-contrast T1, T2 + DWI, and T2 + post-contrast T1 + DWI. RESULTS: In total, 18/43 patients had LR; on T2 images, the expert reader achieved an area under the ROC curve (AUC) of 0.916, sensitivity of 88.9%, and specificity of 76%; the intermediate reader achieved values of 0.890, 88.9%, and 48%, respectively, and the resident achieved values of 0.852, 88.9%, and 48%, respectively. DWI significantly improved the AUC value for the expert radiologist by up to 0.999 (p = 0.04), while post-contrast T1 significantly improved the AUC for the resident by up to 0.950 (p = 0.04). For the intermediate reader, both the T2 + DWI AUC and T2 + post-contrast T1 AUC were better than the T2 AUC (0.976 and 0.980, respectively), but with no statistically significant difference. No statistically significant difference was achieved by any of the three readers by comparing either the T2 + DWI AUCs to the T2 + post-contrast T1 AUCs or the AUCs of the two pairs of sequences to those of the combined three sequences. Furthermore, using the T2 sequences alone, all of the readers achieved a fair number of "equivocal" cases: they decreased with the addition of either DWI or post-contrast T1 sequences and, for the two less experienced readers, they decreased even more with the three combined sequences. CONCLUSIONS: Both DWI and T1 post-contrast MRI increased diagnostic performance for LR diagnosis compared to T2; however, no significant difference was observed by comparing the two different pairs of sequences with the three combined sequences.


Assuntos
Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Retais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Variações Dependentes do Observador , Compostos Organometálicos , Neoplasias Retais/patologia , Sensibilidade e Especificidade
5.
Vasc Endovascular Surg ; 52(5): 335-343, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29576007

RESUMO

PURPOSE: To evaluate the variations in aortic diameters and long-term results in patients who underwent thoracic endovascular aortic repair (TEVAR) for acute blunt traumatic thoracic aortic injuries (BTTAIs). MATERIALS AND METHODS: We retrospectively evaluated 23 patients with a mean age of 39 years (range: 17-74 years) who underwent TEVAR for BTTAI between October 2000 and November 2014. All of the patients underwent computed tomography angiography (CTA) before hospital discharge as a baseline imaging for the subsequent follow-up examinations. The technical success, overall survival, and complications were evaluated. Furthermore, the aortic diameters outside of the stent-graft (1 cm proximal and 1 cm distal to the stent-graft) and the aortic diameters within the stent-graft (2 cm distal to the proximal end and 2 cm proximal to the distal end) were assessed. The diameters at baseline on CTA were compared with those of the latest available follow-up examination. RESULTS: Technical success was 100% with a mean follow-up of 65.4 months (range: 12-171 months). No death was registered, and 2 (8.7%) of 23 endograft-related complications (1 stent-graft distal infolding and 1 endoleak 2 and 4 months after the procedure, respectively) were observed. An increase in aortic diameter either proximal or distal to the stent-graft (mean value 0.7 and 0.5 mm, respectively) or within the stent-graft (mean value of 0.5 mm for both proximal and distal diameters) was registered (mean follow-up at 65.4 months, range: 12-171 months). CONCLUSION: Aortic dilatation following TEVAR for BTTAI is minimal during long-term follow-up. Endovascular treatment represents a durable and safe option in acute BTTAIs.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos/cirurgia , Lesões do Sistema Vascular/cirurgia , Ferimentos não Penetrantes/cirurgia , Adolescente , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Dilatação Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Stents , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Remodelação Vascular , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/fisiopatologia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/fisiopatologia , Adulto Jovem
6.
Ultrasound Med Biol ; 44(4): 771-778, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29352618

RESUMO

The goals of the study described here were to evaluate the feasibility and reproducibility of measuring spleen stiffness (SS) using point shear wave elastography in a series of cirrhotic patients and to investigate whether SS, liver stiffness (LS) and other non-invasive parameters are correlated with the presence of esophagogastric varices (EVs). Fifty-four cirrhotic patients with low-grade EVs or without EVs at esophago-gastro-duodenoscopy were enrolled. They underwent abdominal ultrasound and Doppler ultrasound of hepatic vessels simultaneously with p-SWE of the liver and spleen. In 42 patients, the accuracy of LS and SS, as well as of platelet count and spleen longitudinal diameter, in predicting the presence of EVs was evaluated. The technical success was 90.74% for LS (49/54 patients) and 77.78% for SS (42/54 patients). Inter-observer agreement for SS measurement was high. Both LS and SS correlated with esophago-gastro-duodenoscopy: LS had the highest accuracy in predicting the presence of EVs (area under the receiver operating characteristic curve [AUROC] = 0.913); SS had the lowest accuracy (AUROC = 0.675); platelet count and spleen diameter had intermediate accuracy (AUROC = 0.731 and 0.729, respectively). SS did not have an advantage over LS in predicting low-grade EVs and cannot be proposed as a useful tool in the diagnostic process of cirrhotic patients who require screening esophago-gastro-duodenoscopy.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Varizes Esofágicas e Gástricas/complicações , Hipertensão Portal/fisiopatologia , Baço/diagnóstico por imagem , Baço/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Varizes Esofágicas e Gástricas/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
7.
Vasc Endovascular Surg ; 52(1): 39-45, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29162027

RESUMO

BACKGROUND: To assess whether noncontrast-enhanced magnetic resonance imaging (NC-MRI) is an alternative to contrast-enhanced computed tomography angiography (CTA) for aortoiliac measurements before endovascular abdominal aortic aneurysm repair (EVAR). METHODS: This study encompasses 30 patients admitted for elective EVAR (27 men and 3 women). Two expert readers (vascular radiologist and vascular surgeon) reviewed CTA images in consensus and chose the proper endograft for each patient. Subsequently, a vascular radiologist and a resident radiologist (observer 1 and 2) reviewed CTA and NC-MRI examinations in a double-blind way and completed standard measurements. The interobserver and intermodality agreement was calculated by intraclass correlation coefficients (ICCs). Furthermore, the correlation between the endograft size chosen by the first pair and the second pair of observers was evaluated. RESULTS: Concerning all measurements, no significant difference was found. Both CTA and NC-MRI angiographic measurements showed strong correlation. Interobserver ICCs for CTA and NC-MRI showed ranges of 0.62 to 0.99 (mean: 0.92) and 0.56 to 0.99 (mean: 0.91); intermodality ICCs for observer 1 and 2 showed ranges of 0.64 to 0.99 (mean: 0.92) and 0.56 to 0.99 (mean: 0.92). The CTA and NC-MRI vascular measurements correlated strongly, except for both external iliac artery diameters. The choice of stent size was always the same between the 2 observers; furthermore, graft size was always in agreement with that selected prospectively. CONCLUSION: Computed tomography angiography remains the standard of reference for EVAR planning; NC-MRI can be an option for patients with contraindications for CTA, in particular those with renal impairment.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Iohexol/análogos & derivados , Angiografia por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Iohexol/administração & dosagem , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Stents
8.
Pol J Radiol ; 83: e600-e609, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30800199

RESUMO

PURPOSE: To assess the diagnostic performance of diffusion-weighted imaging (DWI) for the discrimination of complete responder (CR) from the non-complete responder (n-CR) in patients with locally advanced rectal cancer (LARC) undergoing chemotherapy and radiation (CRT). MATERIAL AND METHODS: Between December 2009 and January 2014, 32 patients (33 lesions: one patient had two synchronous lesions) were enrolled in this retrospective study. All patients underwent a pre- and post-CRT conventional MRI study completed with DWI. For both data sets (T2-weighted and DWI), the pre- and post-CRT tumour volume (VT2; VDWI) and the tumour volume reduction ratio (ΔV%) were determined as well as pre- and post-CRT apparent diffusion coefficient (ADC) and ADC change (ΔADC%). Histopathological findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DWI volumetry, as well as ADC. RESULTS: The area under the ROC curve (AUC) revealed a good accuracy of pre- and post-CRT values of VT2 (0.86; 0.91) and VDWI (0.82; 1.00) as well as those of ΔVT2% (0.84) and ΔVDWI% (1.00) for the CR assessment, with no statistical difference. The AUC of pre- and post-CRT ADC (0.53; 0.54) and that of ΔADC% (0.58) were significantly lower. CONCLUSIONS: Both post-CRT VDWI and ΔVDWI% (AUC = 1) are very accurate for the assessment of the CR, in spite of no significant differences in comparison to the conventional post-CRT VT2 (AUC = 0.91) and ΔVT2% (AUC = 0.84). On the contrary, both ADC and ΔADC% values are not reliable.

9.
J Radiol Case Rep ; 11(12): 8-15, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29290905

RESUMO

Pelvic kidney is a relatively common renal malformation as well as duplex kidney; however, the unilateral coexistence of these abnormalities is not frequently found. We present a case of a young woman with a history of hypertension in whom a pelvic and dysmorphic left kidney was discovered during ultrasound examination performed for the study of the renal arteries. Magnetic resonance imaging and computed tomography imaging revealed a duplex pelvic kidney. This combination is very rare; we have not found a similar case reported in the literature.


Assuntos
Hipertensão/etiologia , Nefropatias/diagnóstico por imagem , Rim/anormalidades , Rim/diagnóstico por imagem , Adulto , Feminino , Humanos , Nefropatias/complicações , Nefropatias/congênito
10.
J Plast Reconstr Aesthet Surg ; 69(3): e48-54, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26867468

RESUMO

BACKGROUND: Both tissue expanders and implants are commonly used during breast reconstructions. These devices are the preferred choice of many plastic surgeons around the world during breast reconstruction due to their technical ease of use, low comorbidity and safety. However, several issues such as the integrity of the chest wall during and after tissue expansion remain unclear. Here we present a longitudinal study that shows deformities of the chest wall caused by the use of tissue expanders. PATIENTS AND METHODS: A prospective longitudinal study of the chest wall in 36 patients who underwent immediate two-stage expander-to-implant reconstruction from 2010 to 2013 was conducted to evaluate the possible causes of chest wall deformity. Computed tomography (CT) scans of the chest walls were taken before the second-stage reconstruction and after 1 year. Chest wall deformities (graded from I, no deformities, to V, costal fracture) were evaluated with CT scans. RESULTS: This study examined 36 breast reconstructions. Chest wall deformities were observed by a CT scan before the second-stage reconstruction. There were eight patients with grade I scores, 14 with grade II, 10 with grade III and four with grade IV. No cases of costal fracture (grade V) were observed. At the 1-year follow-up after the TE/implant change, 22 patients had the same degree of chest wall deformity. Ten patients showed an improvement and four a higher-grade deformity. CONCLUSION: Chest wall deformities commonly occur after tissue expander/implant reconstruction. However, the size of the expander, reconstruction timing and filling volume are not correlated with deformity development.


Assuntos
Implantes de Mama , Mamoplastia/métodos , Parede Torácica/fisiopatologia , Dispositivos para Expansão de Tecidos/efeitos adversos , Expansão de Tecido/efeitos adversos , Adulto , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Mamoplastia/efeitos adversos , Mastectomia/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Parede Torácica/diagnóstico por imagem , Expansão de Tecido/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
12.
Acta Radiol ; 57(2): 188-96, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25824206

RESUMO

BACKGROUND: Recently different software with the ability to plan ablation volumes have been developed in order to minimize the number of attempts of positioning electrodes and to improve a safe overall tumor coverage. PURPOSE: To assess the feasibility of three-dimensional cone beam computed tomography (3D CBCT) fusion imaging with "virtual probe" positioning, to predict ablation volume in lung tumors treated percutaneously. MATERIAL AND METHODS: Pre-procedural computed tomography contrast-enhanced scans (CECT) were merged with a CBCT volume obtained to plan the ablation. An offline tumor segmentation was performed to determine the number of antennae and their positioning within the tumor. The volume of ablation obtained, evaluated on CECT performed after 1 month, was compared with the pre-procedural predicted one. Feasibility was assessed on the basis of accuracy evaluation (visual evaluation [VE] and quantitative evaluation [QE]), technical success (TS), and technical effectiveness (TE). RESULTS: Seven of the patients with lung tumor treated by percutaneous thermal ablation were selected and treated on the basis of the 3D CBCT fusion imaging. In all cases the volume of ablation predicted was in accordance with that obtained. The difference in volume between predicted ablation volumes and obtained ones on CECT at 1 month was 1.8 cm(3) (SD ± 2, min. 0.4, max. 0.9) for MW and 0.9 cm(3) (SD ± 1.1, min. 0.1, max. 0.7) for RF. CONCLUSION: Use of pre-procedural 3D CBCT fusion imaging could be useful to define expected ablation volumes. However, more patients are needed to ensure stronger evidence.


Assuntos
Ablação por Cateter , Tomografia Computadorizada de Feixe Cônico , Neoplasias Pulmonares/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Resultado do Tratamento
13.
Eur Radiol ; 26(2): 381-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26045345

RESUMO

PURPOSE: To compare the diagnostic performance of cone-beam CT (CBCT)-guided and CT fluoroscopy (fluoro-CT)-guided technique for transthoracic needle biopsy (TNB) of lung nodules. METHODS: The hospital records of 319 consecutive patients undergoing 324 TNBs of lung nodules in a single radiology unit in 2009-2013 were retrospectively evaluated. The newly introduced CBCT technology was used to biopsy 123 nodules; 201 nodules were biopsied by conventional fluoro-CT-guided technique. We assessed the performance of the two biopsy systems for diagnosis of malignancy and the radiation exposure. RESULTS: Nodules biopsied by CBCT-guided and by fluoro-CT-guided technique had similar characteristics: size, 20 ± 6.5 mm (mean ± standard deviation) vs. 20 ± 6.8 mm (p = 0.845); depth from pleura, 15 ± 15 mm vs. 15 ± 16 mm (p = 0.595); malignant, 60% vs. 66% (p = 0.378). After a learning period, the newly introduced CBCT-guided biopsy system and the conventional fluoro-CT-guided system showed similar sensitivity (95% and 92%), specificity (100% and 100%), accuracy for diagnosis of malignancy (96% and 94%), and delivered non-significantly different median effective doses [11.1 mSv (95 % CI 8.9-16.0) vs. 14.5 mSv (95% CI 9.5-18.1); p = 0.330]. CONCLUSION: The CBCT-guided and fluoro-CT-guided systems for lung nodule biopsy are similar in terms of diagnostic performance and effective dose, and may be alternatively used to optimize the available technological resources. KEY POINTS: • CBCT-guided and fluoro-CT-guided lung nodule biopsy provided high and similar diagnostic accuracy. • Effective dose from CBCT-guided and fluoro-CT-guided lung nodule biopsy was similar. • To optimize resources, CBCT-guided lung nodule biopsy may be an alternative to fluoro-CT-guided.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Adulto , Idoso , Biópsia por Agulha/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Fluoroscopia/métodos , Humanos , Biópsia Guiada por Imagem/métodos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
14.
Acta Radiol ; 56(12): 1471-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25487715

RESUMO

BACKGROUND: Computed tomography angiography (CTA) is the most employed modality in the follow-up after endovascular aneurysm repair (EVAR) of abdominal aorta (AA); repeated standard controls expose patients to a high cumulative radiation dose (RD). PURPOSE: To compare image quality and RD between 100 kV and 120 kV protocols in the same group of patients, previously treated with EVAR. MATERIAL AND METHODS: Thirty patients, who had performed a previous CTA at 120 kV, underwent a low dose CTA with the same 64-detector machine. Images were evaluated qualitatively and quantitatively. The influence of body mass index (BMI), considering three groups of patients (normal weight, overweight, and obese) was also assessed. RD values (volume CT dose index and effective dose) were calculated. RESULTS: The mean qualitative score at 100 kV was worse than that at 120 kV, but the difference was not statistically significant and in all cases the image quality was satisfactory. At 100 kV the vessels mean attenuation value was significantly higher; signal-to-noise ratio significantly lower; contrast-to-noise ratio lower, but the difference was not significant. Regarding BMI, the difference in the qualitative score was significant in the obese group, but not in the other two groups; of the quantitative parameters only the signal-to-noise ratio presented a significant difference in the obese group. The average CTDIvol was reduced by 22% and the mean effective dose by 36% with the 100 kV protocol compared to the 120 kV protocol. Both differences were significant. CONCLUSION: The 100 kV protocol allowed a consistent RD reduction, maintaining a satisfactory image quality in all patients.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Doses de Radiação , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Meios de Contraste , Feminino , Seguimentos , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Radiol Med ; 119(7): 483-98, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24981482

RESUMO

Unresectable locally advanced pancreatic cancer with or without metastatic disease is associated with a very poor prognosis. Ablation techniques are based on direct application of chemical, thermal, or electrical energy to a tumor, which leads to cellular necrosis. Initial studies about ablation therapies of the pancreas were associated with significant morbidity and mortality, which limited widespread adoption. Modifications to the various applications, in particular combining the techniques with high-quality imaging and intra-operative approach has enabled real-time treatment monitoring and significant improvements in safety. Inoperable cases of pancreatic cancer have been treated by various ablation techniques in the last few years with promising results. The purpose of this review is to present the current status of local ablative therapies in the treatment of pancreatic advanced tumor.


Assuntos
Técnicas de Ablação , Neoplasias Pancreáticas/cirurgia , Eletroporação/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Pancreatectomia , Neoplasias Pancreáticas/patologia , Complicações Pós-Operatórias , Radiografia Intervencionista
16.
Radiol Med ; 119(7): 533-40, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25001585

RESUMO

In the last decades an increased incidence of new renal tumor cases has been for clinically localized, small tumors <2.0 cm. This trend for small, low-stage tumors is the reflection of earlier diagnosis primarily as a result of the widespread and increasing use of non-invasive abdominal imaging modalities such as ultrasound, computerized tomography, and magnetic resonance imaging. Renal tumors are often diagnosed in elderly patients, with medical comorbidities whom the risk of surgical complications may pose a greater risk of death than that due to the tumor itself. In these patients, unsuitable for surgical approach, thermal ablation represents a valid alternative to traditional surgery. Thermal ablation is a less invasive, less morbid treatment option thanks to reduced blood loss, lower incidence of complications during the procedure and a less long convalescence. At present, the most widely used thermal ablative techniques are cryoablation, radiofrequency ablation and microwave ablation (MWA). MWA offers many benefits of other ablation techniques and offers several other advantages: higher intratumoral temperatures, larger tumor ablation volumes, faster ablation times, the ability to use multiple applicators simultaneously, optimal heating of cystic masses and tumors close to the vessels and less procedural pain. This review aims to provide the reader with an overview about the state of the art of microwave ablation for renal tumors and to cast a glance on the new development trends of this technique.


Assuntos
Técnicas de Ablação/tendências , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Diagnóstico por Imagem , Humanos , Neoplasias Renais/diagnóstico , Neoplasias Renais/patologia , Estadiamento de Neoplasias , Radiografia Intervencionista , Ultrassonografia de Intervenção
17.
Radiol Med ; 119(1): 75-82, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24234180

RESUMO

PURPOSE: This study was done to evaluate the feasibility, effectiveness and safety of microwave (MW) ablation of lung tumours. MATERIALS AND METHODS: Twenty-four patients underwent percutaneous MW ablation of 26 intraparenchymal pulmonary masses. All patients were judged to be inoperable on the basis of tumour stage, comorbidities, advanced age and/or refusal to undergo surgery. Ablation was performed using a microwave generator (Evident Microwave Ablation System, Covidien Ltd., Dublin). Lesions with a diameter ≤ 3 cm were treated with a single antenna, lesions with a diameter >3 cm were treated by positioning two or more antennae, simultaneously. All patients underwent computed tomography (CT) follow-up with and without contrast administration at 1, 3 and 6 months and then yearly in combination with complete blood and metabolic tests. RESULTS: Technical success was 100 %. No major complications were recorded. Asymptomatic grade-1 pneumothorax was recorded in 9 patients (37.5 %). One case of asymptomatic pleural effusion and one of haemoptysis, not requiring transfusion, were observed. No patients were diagnosed with a post-ablation syndrome. Complete necrosis was observed in 16 of 26 lesions (61.6 %). Partial necrosis was obtained in 30.8 % (8/26 lesions); in one case (3.8 %) a progression of the disease was recorded and in another case (3.8 %) a stability was observed. CONCLUSIONS: Our preliminary experience may be considered in accordance with literature dates, in terms of efficacy and safety.


Assuntos
Ablação por Cateter/métodos , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Ácidos Tri-Iodobenzoicos
18.
J Vasc Interv Radiol ; 24(10): 1513-20, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24070507

RESUMO

PURPOSE: To evaluate the safety and efficacy of percutaneous microwave (MW) ablation treatment in locally advanced, nonresectable, nonmetastatic pancreatic head cancer. MATERIALS AND METHODS: Ten patients with pancreatic head cancer treated with percutaneous (n = 5) or laparotomic (n = 5) MW ablation were retrospectively reviewed. The MW generator used (45 W at 915 MHz) was connected by coaxial cable to 14-gauge straight MW antennas with a 3.7- or 2-cm radiating section. One or two antennae were used, with an ablation time of 10 minutes. Ultrasonographic (US) and combined US/cone-beam computed tomographic (CT) guidance were used in five patients each. Follow-up was performed by CT after 1, 3, 6, and, when possible, 12 months. Tumor response was assessed per Response Evaluation Criteria In Solid Tumors (version 1.1) and Choi criteria. The feasibility, safety, and major and minor complications associated with quality of life (QOL) were recorded prospectively. RESULTS: The procedure was feasible in all patients (100%). One late major complication was observed in one patient, and no visceral injury was detected. No patient had further surgery, and all minor complications resolved during the hospital stay. An improvement in QOL was observed in all patients despite a tendency to return to preoperative levels in the months following the procedure, without the influence of minor complications. No repeat treatment was performed. CONCLUSIONS: Despite the small number of patients, the present results can be considered encouraging, showing that MW ablation is a feasible approach in the palliative treatment of pancreatic tumors.


Assuntos
Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Laparotomia/métodos , Cisto Pancreático/etiologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirurgia , Pancreatite/etiologia , Idoso , Feminino , Humanos , Masculino , Micro-Ondas/efeitos adversos , Micro-Ondas/uso terapêutico , Cisto Pancreático/diagnóstico , Pancreatite/diagnóstico , Resultado do Tratamento
19.
Clin Imaging ; 37(6): 1061-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24012208

RESUMO

This study evaluates retrospectively the accuracy and reproducibility of multislice computed tomography with colon water distension (MSCT-c) in diagnosing bowel (BE) and ureteral (UE) endometriosis. Sixty-four patients underwent MSCT-c and videolaparoscopic surgery. Two radiologists reviewed MSCT-c examinations: sensitivity and specificity were calculated, considering histological exam as reference standard. In the BE cases, the degree of bowel wall infiltration was also assessed. Sensitivity and specificity for both readers were 100% and 97.6% for BE and 72.2% and 100% for UE; the interobserver agreement was excellent. The degree of bowel wall involvement was correctly defined in 90.9% of cases. MSCT-c is an accurate and reproducible technique but-considering the age of the patients-delivers a nonnegligible radiation dose.


Assuntos
Endometriose/diagnóstico por imagem , Enteropatias/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Doenças Uterinas/diagnóstico por imagem , Adulto , Colo/diagnóstico por imagem , Feminino , Humanos , Intestinos/diagnóstico por imagem , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ureter/diagnóstico por imagem , Água
20.
J Cardiovasc Electrophysiol ; 24(11): 1232-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23875875

RESUMO

INTRODUCTION: Left atrial diverticula (LAD) have been reported to be (1) at risk for intracavitary thrombosis and cardiac perforation during ablation and (2) sites of extrapulmonary vein foci. In atrial fibrillation (AF) ablation, their presence might undermine procedure safety and efficacy. This observational study evaluates the morphology and clinical impact of LAD in patients undergoing AF ablation. METHODS AND RESULTS: Consecutive patients undergoing computed tomography scan (Aquilion 64, Toshiba, Otawara, Japan) and AF ablation with imaging integration (CARTO 3 Merge, Biosense Webster, CA, USA) in our center were included. Morphologic analysis was performed by 2 independent radiologists. Ablation was obtained by irrigated radiofrequency energy (Navistar Thermocool or Thermocool SF, Biosense Webster). Out of 212 patients, 58 (27.3%) had LAD; 74.4% of LAD were located in the anterosuperomedial left atrium. In patients with and without LAD, the prevalence of prior cerebrovascular events was similarly low. The rate of major periprocedure complications did not differ significantly: 1.7% versus 2.6% (P = 1) in patients with and without LAD, respectively. However, 1 case of cardiac perforation occurred during ablation in a diverticulum. During follow-up, survival free from arrhythmia recurrences was comparable in the 2 groups. CONCLUSION: LAD are present in about one-fourth of patients undergoing AF ablation and, in general, they have no impact on its safety and efficacy. However, occasionally, radiofrequency energy delivery in a LAD can cause tissue overheating and perforation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Divertículo/complicações , Adulto , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Divertículo/diagnóstico por imagem , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Recidiva , Fatores de Risco , Irrigação Terapêutica , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA