Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Am J Audiol ; : 1-7, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37988681

RESUMO

PURPOSE: This study discusses the history and current state of the newborn hearing screening program in Québec and aims to assess general challenges associated with establishing universal newborn hearing screening (UNHS) programs. METHOD: We reviewed the statistics of the occurrence and long-term effects of congenital hearing loss and the immediate and long-term benefits of UNHS and its limitations. The resources for this study included financial reports related to establishing UNHS in different health care systems; Canadian provincial, territorial, and federal regulations and publications; local and nationwide media; and interviews health care staff and program managers. RESULTS: Because of its benefits and its cost-effectiveness, UNHS programs have been implemented in many health care systems around the world. Despite Canada's success in offering a wide array of health care services to its citizens, certain provinces trail behind others in developing UNHS programs. Although there have been recent improvements in the screening rate of the province of Québec, nearly half of all Québec newborns continue to not be screened for hearing loss. The reasons for the current low screening rate include delays in implementation, information-technology complications, operating costs, and lack of public awareness. CONCLUSIONS: For UNHS to be implemented in a timely fashion, those involved in the process should first understand what challenges may arise. Québec's experience with this process may provide useful lessons for other health care systems.

2.
J Acoust Soc Am ; 154(5): 2790-2799, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37916864

RESUMO

Optical coherence tomography (OCT) vibrometry is a non-invasive tool for functional imaging of the middle ear. It provides spatially resolved vibrational responses and also anatomical images of the same ear. Our objective here was to explore the potential of OCT vibration measurements at the incus, as well as at the umbo, to distinguish among middle-ear disorders. Our approach was to build finite-element models of normal and pathological ears, generate large amounts of synthetic data, and then classify the simulated data into normal and pathological groups using a decision tree based on features extracted from simulated vibration magnitudes. We could distinguish between normal ears and ears with incudomallear joint (IMJ) disarticulation or stapes fixation, with the sensitivity and specificity both being 1.0; distinguish between stapes fixation and IMJ disarticulation with a sensitivity of 0.900 and a specificity of 0.889; and distinguish ears with ISJ disarticulation from normal ears with a sensitivity of 0.784 and a specificity of 0.872. Less extreme pathologies were also simulated. The results suggest that the vibration measurements within the middle ear that can be provided by OCT (e.g., at the incus) may be very valuable for diagnosis.


Assuntos
Orelha Média , Tomografia de Coerência Óptica , Orelha Média/diagnóstico por imagem , Articulações , Vibração
3.
J Assoc Res Otolaryngol ; 24(3): 339-363, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37165211

RESUMO

PURPOSE: Optical coherence tomography (OCT) is an emerging imaging modality which is non-invasive, can be employed in vivo, and can record both anatomy and vibrations. The purpose here is to explore the application of finite-element (FE) modelling to OCT data. METHODS: We recorded vibrations for three human cadaver middle ears using OCT. We also have X-ray microCT images from the same ears. Three FE models were built based on geometries obtained from the microCT images. The material properties and boundary conditions of the models were obtained from previously reported studies. RESULTS: Tympanic-membrane (TM) vibration patterns were computed for the three models and compared with the patterns measured using OCT. Frequency responses were also computed for all three models for several locations in the middle ear and compared with the OCT displacements and with the literature. The three models were compared with each other in terms of geometry and function. Parameter sensitivity analyses were done and the results were compared among the models and with the literature. The simulated TM displacement patterns are qualitatively similar to the OCT results. The simulated displacements are closer to the OCT results for 500 Hz and 1 kHz but the differences are greater at 2 kHz. CONCLUSION: This study provides an initial look at the combined use of OCT measurements and FE modelling based on subject-specific anatomy. The geometries and parameters of the existing FE models could be modified for individual patients in the future to help identify abnormalities in the middle ear.


Assuntos
Orelha Média , Tomografia de Coerência Óptica , Humanos , Microtomografia por Raio-X , Tomografia de Coerência Óptica/métodos , Orelha Média/diagnóstico por imagem , Orelha Média/fisiologia , Membrana Timpânica/fisiologia , Vibração , Análise de Elementos Finitos
4.
J Assoc Res Otolaryngol ; 23(6): 739-750, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36100816

RESUMO

Tympanometry provides an objective measurement of the status of the middle ear. During tympanometry, the ear-canal pressure is varied, while the response of the ear to sound pressure is measured. The effects of the pressure on the mechanics of the middle ear are not well understood. This study is a continuation of our previous work in which the vibration response of the gerbil eardrum was measured in vivo under quasi-static pressure steps. In this study, we delivered a continuous pressure sweep to the middle ear and measured the vibration response at four locations for six gerbils. Vibrations were recorded using a single-point laser Doppler vibrometer and glass-coated reflective beads (diameter ~ 40 µm) at the umbo and on the mid-manubrium, posterior pars tensa and anterior pars tensa.The vibration magnitudes were similar to those in the previous step-wise pressurization experiments. Most gerbils showed repeatability within less than 10 dB for consecutive cycles. As described in the previous study, as the frequency was increased at ambient pressure, the vibration magnitude on the manubrium increased slightly to a broad peak (referred to as R1) and then decreased until a small peak appeared (referred to as R2), followed by multiple peaks and troughs as the magnitude decreased further. The low-frequency vibration magnitude (at 1 kHz) decreased monotonically as the pressure became more negative except for a dip (about 500 Pa wide) that occurred between - 700 and - 1800 Pa. The lowest overall magnitude was recorded in the dip at mid-manubrium. The vibration magnitudes also decreased as the middle-ear pressure was made more positive and were larger than those at negative pressures. R1 was only visible at negative and small positive middle-ear pressures, while R2 was visible for both positive and negative pressures. R2 split into multiple branches after the middle-ear pressure became slightly positive. No magnitude dip was visible for positive middle-ear pressures.The low-frequency vibration magnitudes at negative middle-ear pressures on the pars tensa were higher than those on the manubrium. R1 was not visible for large negative middle-ear pressures on the pars tensa. R2 appeared as a multi-peak feature on the pars tensa as well, and a higher-frequency branch on the posterior pars tensa appeared as a trough on the anterior pars tensa. The magnitude dip was not present on the pars tensa. The largest overall magnitude was recorded at the R2 peak on the posterior pars tensa.The results of this study expand on the findings of the step-wise pressurization experiments and provide further insight into the evolution of the vibration response of the eardrum under quasi-static pressures.


Assuntos
Membrana Timpânica , Vibração , Animais , Membrana Timpânica/fisiologia , Gerbillinae , Orelha Média/fisiologia , Som
5.
J Assoc Res Otolaryngol ; 21(4): 287-302, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32783164

RESUMO

Tympanometry is a relatively simple non-invasive test of the status of the middle ear. An important step towards understanding the mechanics of the middle ear during tympanometry is to make vibration measurements on the eardrum under tympanometric pressures. In this study, we measured in vivo vibration responses in 11 gerbils while varying the middle-ear pressure quasi-statically, with the ear canal at ambient pressure. Vibrations were recorded using a single-point laser Doppler vibrometer with five glass-coated reflective beads (diameter ~ 40 µm) as targets. The locations were the umbo, mid-manubrium, posterior pars tensa, anterior pars tensa and pars flaccida. As described in earlier studies, the unpressurized vibration magnitude was flat at low frequencies, increased until a resonance frequency at around 1.8-2.5 kHz, and became complex at higher frequencies. At both the umbo and mid-manubrium points, when the static pressure was decreased to the most negative middle-ear pressure (- 2500 Pa), the low-frequency vibration magnitude (measured at 1.0 kHz) showed a monotonic decrease, except for an unexpected dip at around - 500 to - 1000 Pa. This dip was not present for the pars-tensa and pars-flaccida points. The resonance frequency shifted to higher frequencies, to around 7-8 kHz at - 2500 Pa. For positive middle-ear pressures, the low-frequency vibration magnitude decreased monotonically, with no dip, and the resonance frequency shifted to around 5-6 kHz at + 2500 Pa. There was more inter-specimen variability on the positive-pressure side than on the negative-pressure side. The low-frequency vibration magnitudes on the negative-pressure side were higher for the pars-tensa points than for the umbo and mid-manubrium points, while the magnitudes were similar at all four locations on the positive-pressure side. Most gerbils showed repeatability within less than 10 dB for consecutive cycles. The results of this study provide insight into the mechanics of the gerbil middle ear under tympanometric pressures.


Assuntos
Testes de Impedância Acústica/métodos , Gerbillinae/fisiologia , Membrana Timpânica/fisiologia , Animais , Masculino , Pressão , Valores de Referência , Vibração
6.
J Assoc Res Otolaryngol ; 21(1): 21-32, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31620954

RESUMO

The ossicular joints of the middle ear can significantly affect middle-ear function, particularly under conditions such as high-intensity sound pressures or high quasi-static pressures. Experimental investigations of the mechanical behaviour of the human incudostapedial joint have shown strong non-linearity and asymmetry in tension and compression tests, but some previous finite-element models of the joint have had difficulty replicating such behaviour. In this paper, we present a finite-element model of the joint that can match the asymmetry and non-linearity well without using different model structures or parameters in tension and compression. The model includes some of the detailed structures of the joint seen in histological sections. The material properties are found from the literature when available, but some parameters are calculated by fitting the model to experimental data from tension, compression and relaxation tests. The model can predict the hysteresis loops of loading and unloading curves. A sensitivity analysis for various parameters shows that the geometrical parameters have substantial effects on the joint mechanical behaviour. While the joint capsule affects the tension curve more, the cartilage layers affect the compression curve more.


Assuntos
Ossículos da Orelha/fisiologia , Modelos Biológicos , Elasticidade , Análise de Elementos Finitos , Humanos , Viscosidade
7.
Int J Pediatr Otorhinolaryngol ; 127: 109659, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31493551

RESUMO

OBJECTIVE: Distortion-product otoacoustic emissions (DPOAEs) are currently used in many newborn hearing screening programs as the initial hearing test, typically testing frequencies between 1 and 4 or 6 kHz, but they have been associated with high false-positive rates. The objective was to investigate the possible benefit of high-frequency DPOAEs for reducing false-positive rates. METHODS: 255 healthy newborns (138 males and 117 females) undergoing conventional hearing screening based on DPOAE and automated auditory brainstem response (AABR) testing were recruited. High-frequency DPOAE amplitudes, noise floors and signal-to-noise ratios (SNRs) were measured for f2 frequencies up to 12 kHz. RESULTS: Of the 255 newborns who participated in this study, 23 (9%) failed the conventional DPOAE test but passed the AABR test, and 8 (3%) failed both tests. For an SNR threshold of 6 dB, high-frequency DPOAE tests at f2 = 4, 6, 8 and 10 kHz resulted in a reduction in the false-positive rate from 9% to 0.4%, or to zero if only three of the four frequencies were required to exceed the threshold. SNRs were lower in newborns with birth weights greater than 4000 g; lower at 2 kHz in newborns with a gestational age of 41 weeks; slightly higher in vaginally-delivered newborns; and higher at 2 kHz with increasing age in the group that failed the conventional DPOAE test but passed AABR. CONCLUSION: High-frequency DPOAEs resulted in a reduction in the DPOAE failure rate and the false-positive rate. These findings may be helpful in universal newborn hearing screening programs.


Assuntos
Testes Auditivos/métodos , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas , Audiometria de Resposta Evocada , Peso ao Nascer , Reações Falso-Positivas , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Razão Sinal-Ruído
8.
J Assoc Res Otolaryngol ; 18(5): 671-686, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28721606

RESUMO

The anatomical differences between the newborn ear and the adult one result in different input admittance responses in newborns than those in adults. Taking into account fluid-structure interactions, we have developed a finite-element model to investigate the wideband admittance responses of the ear canal and middle ear in newborns for frequencies up to 10 kHz. We have also performed admittance measurements on a group of 23 infants with ages between 14 and 28 days, for frequencies from 250 to 8000 Hz with 1/12-octave resolution. Sensitivity analyses of the model were performed to investigate the contributions of the ear canal and middle ear to the overall admittance responses, as well as the effects of the material parameters, measurement location and geometrical variability. The model was validated by comparison with our new data and with data from the literature. The model provides a quantitative understanding of the canal and middle-ear resonances around 500 and 1800 Hz, respectively, and also predicts the effects of the first resonance mode of the middle-ear cavity (around 6 kHz) as well as the first and second standing-wave modes in the ear canal (around 7.2 and 9.6 kHz, respectively), which may explain features seen in our high-frequency-resolution clinical measurements.


Assuntos
Meato Acústico Externo/fisiologia , Audição/fisiologia , Modelos Teóricos , Membrana Timpânica/fisiologia , Análise de Elementos Finitos , Humanos , Recém-Nascido , Som
9.
Int Forum Allergy Rhinol ; 7(8): 837-841, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28614638

RESUMO

BACKGROUND: Endoscopic sinus surgery poses unique training challenges due to complex and variable anatomy, and the risk of major complications. We sought to create and provide validity evidence for a novel 3D-printed simulator of the nose and paranasal sinuses. METHODS: Sinonasal computed tomography (CT) images of a patient were imported into 3D visualization software. Segmentation of bony and soft tissue structures was then performed. The model was printed using simulated bone and soft tissue materials. Rhinologists and otolaryngology residents completed 6 prespecified tasks including maxillary antrostomy and frontal recess dissection on the simulator. Participants evaluated the model using survey ratings based on a 5-point Likert scale. The average time to complete each task was calculated. Descriptive analysis was used to evaluate ratings, and thematic analysis was done for qualitative questions. RESULTS: A total of 20 participants (10 rhinologists and 10 otolaryngology residents) tested the model and answered the survey. Overall the participants felt that the simulator would be useful as a training/educational tool (4.6/5), and that it should be integrated as part of the rhinology training curriculum (4.5/5). The following responses were obtained: visual appearance 4.25/5; realism of materials 3.8/5; and surgical experience 3.9/5. The average time to complete each task was lower for the rhinologist group than for the residents. CONCLUSION: We describe the development and validation of a novel 3D-printed model for the training of endoscopic sinus surgery skills. Although participants found the simulator to be a useful training and educational tool, further model development could improve the outcome.


Assuntos
Endoscopia/educação , Modelos Anatômicos , Procedimentos Cirúrgicos Nasais/educação , Nariz/anatomia & histologia , Nariz/cirurgia , Humanos , Nariz/diagnóstico por imagem , Impressão Tridimensional , Tomografia Computadorizada por Raios X
10.
J Assoc Res Otolaryngol ; 18(1): 25-48, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27718037

RESUMO

Admittance measurement is a promising tool for evaluating the status of the middle ear in newborns. However, the newborn ear is anatomically very different from the adult one, and the acoustic input admittance is different than in adults. To aid in understanding the differences, a finite-element model of the newborn ear canal and middle ear was developed and its behaviour was studied for frequencies up to 2000 Hz. Material properties were taken from previous measurements and estimates. The simulation results were within the range of clinical admittance measurements made in newborns. Sensitivity analyses of the material properties show that in the canal model, the maximum admittance and the frequency at which that maximum admittance occurs are affected mainly by the stiffness parameter; in the middle-ear model, the damping is as important as the stiffness in influencing the maximum admittance magnitude but its effect on the corresponding frequency is negligible. Scaling up the geometries increases the admittance magnitude and shifts the resonances to lower frequencies. The results suggest that admittance measurements can provide more information about the condition of the middle ear when made at multiple frequencies around its resonance.


Assuntos
Estimulação Acústica , Meato Acústico Externo/fisiologia , Orelha Média/fisiologia , Análise de Elementos Finitos , Recém-Nascido/fisiologia , Humanos , Vibração
11.
Int J Pediatr Otorhinolaryngol ; 86: 156-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27260599

RESUMO

OBJECTIVES: Newborn hearing screening includes testing with otoacoustic emissions and the auditory brainstem response. Unfortunately, both tests are affected by the presence of material in the ear canal and middle ear such as vernix, meconium, and amniotic fluid. The objective of this study was to determine to what extent occlusion of the ear canal as seen on otoscopy affects wideband energy reflectance measurements in newborns. A secondary objective was to obtain additional normative wideband reflectance data in newborns. METHODS: Newborns from a well-baby nursery were enrolled. Wideband energy reflectance measurements and otoscopy were done immediately after the hearing screening. Occlusion of the ear canal as seen on otoscopy was described on a scale of 0-100%. RESULTS: A total of 156 babies were enrolled (mean age = 25 hours). A statistically significant difference in the reflectance at ambient pressure was found between the 0-70% and 80-100% occlusion groups. There was no significant difference in reflectance between the right and the left ears. The median reflectance pattern generally followed that of previous studies but in certain frequency regions the present reflectance values were higher. CONCLUSION: A significant increase in reflectance occurs when 70%-80% of the ear-canal diameter is occluded. Taking otoscopy findings into account may improve the interpretation of reflectance measurements. However, further studies are required to better establish the relationship between canal occlusion and reflectance.


Assuntos
Meato Acústico Externo/diagnóstico por imagem , Transtornos da Audição/diagnóstico , Otoscopia , Testes de Impedância Acústica , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Feminino , Humanos , Recém-Nascido , Masculino , Triagem Neonatal , Emissões Otoacústicas Espontâneas/fisiologia
12.
J Assoc Res Otolaryngol ; 16(5): 547-67, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26197870

RESUMO

We present a finite-element model of the gerbil middle ear that, using a set of baseline parameters based primarily on a priori estimates from the literature, generates responses that are comparable with responses we measured in vivo using multi-point vibrometry and with those measured by other groups. We investigated the similarity of numerous features (umbo, pars-flaccida and pars-tensa displacement magnitudes, the resonance frequency and break-up frequency, etc.) in the experimental responses with corresponding ones in the model responses, as opposed to simply computing frequency-by-frequency differences between experimental and model responses. The umbo response of the model is within the range of variability seen in the experimental data in terms of the low-frequency (i.e., well below the middle-ear resonance) magnitude and phase, the main resonance frequency and magnitude, and the roll-off slope and irregularities in the response above the resonance frequency, but is somewhat high for frequencies above the resonance frequency. At low frequencies, the ossicular axis of rotation of the model appears to correspond to the anatomical axis but the behaviour is more complex at high frequencies (i.e., above the pars-tensa break-up). The behaviour of the pars tensa in the model is similar to what is observed experimentally in terms of magnitudes, phases, the break-up frequency of the spatial vibration pattern, and the bandwidths of the high-frequency response features. A sensitivity analysis showed that the parameters that have the strongest effects on the model results are the Young's modulus, thickness and density of the pars tensa; the Young's modulus of the stapedial annular ligament; and the Young's modulus and density of the malleus. Displacements of the tympanic membrane and manubrium and the low-frequency displacement of the stapes did not show large changes when the material properties of the incus, stapes, incudomallear joint, incudostapedial joint, and posterior incudal ligament were changed by ±10 % from their values in the baseline parameter set.


Assuntos
Orelha Média/fisiologia , Análise de Elementos Finitos , Estimulação Acústica , Animais , Gerbillinae , Som
13.
Laryngoscope ; 125(4): E138-42, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25431116

RESUMO

OBJECTIVES/HYPOTHESIS: Otoacoustic emissions have frequently been used for newborn hearing screening. However, they have low specificities and high referral rates. The presence of amniotic fluid in the middle ear is one reason for these problems. The aim of this study was to determine the effects of human amniotic fluid on otoacoustic emissions and on middle-ear function. METHODS: Forty-six chinchillas were randomly divided into eight groups based on the type (amniotic fluid or normal saline) and volume (0.5, 1, 1.5, 2 ml) of liquid introduced into the middle ear. Distortion product otoacoustic emission (DPOAE) and wideband reflectance (WBR) measurements were taken under inhalational anaesthesia before and after introduction of middle-ear liquid. The differences in these measurements were subjected to statistical analyses. STUDY DESIGN: Prospective controlled animal study. RESULTS: Significant reductions of DPOAE levels and increases in WBR occurred across all frequencies when there was liquid in the middle ear, and the changes became greater for increased volumes of liquid. Changes in the noise level had important effects on the otoacoustic-emission signal-to-noise ratio at the three lowest frequencies. CONCLUSION: Both human amniotic fluid and saline in the chinchilla middle ear resulted in changes in otoacoustic-emission detection patterns and WBR that may be relevant to newborn hearing screening.


Assuntos
Líquido Amniótico , Orelha Média/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Cloreto de Sódio/farmacologia , Testes de Impedância Acústica/métodos , Animais , Chinchila , Modelos Animais de Doenças , Orelha Média/efeitos dos fármacos , Feminino , Humanos , Instilação de Medicamentos , Emissões Otoacústicas Espontâneas/efeitos dos fármacos , Distribuição Aleatória , Valores de Referência , Sensibilidade e Especificidade
15.
Int J Pediatr Otorhinolaryngol ; 78(5): 711-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24613088

RESUMO

BACKGROUND AND OBJECTIVES: Otoacoustic emission (OAE) tests are currently used to screen newborns for congenital hearing loss in many Universal Newborn Hearing Screening programs. However, there are concerns about high referral and false-positive rates. Various protocols have been used to address this problem. The main objective of this review is to determine the effects of different screening protocols on the referral rates and positive predictive values (PPV) of the OAE newborn screening test. METHODS: Eligible studies published in English from January 1990 until August 2012 were identified through searches of MEDLINE, Medline In-Process, Embase, PubMed (NCBI), ISI Web of Science, and the Cochrane Central Register of clinical controlled trials. Two reviewers independently screened the data sources, using pre-defined inclusion criteria to generate a list of eligible articles. Data extracted included the number of newborns screened, age at screening, OAE pass criteria, frequencies screened, number of retests, referral rates, and the number of newborns identified with permanent congenital hearing loss. RESULTS: Ten articles met the inclusion criteria, with a total of 119,714 newborn participants. The pooled referral rate was 5.5%. Individual referral rates ranged from 1.3% to 39%; the PPV from 2 to 40%. Increasing the age at initial screening and performing retests reduced the referral rate. Likewise, screenings involving higher frequencies had lower referral rates. CONCLUSION: Delaying newborn hearing screening improves test results but may not be practical in all contexts. The use of higher frequencies and more sophisticated OAE devices may be useful approaches to ensure better performance of the OAE test in newborn hearing screening.


Assuntos
Perda Auditiva , Triagem Neonatal , Emissões Otoacústicas Espontâneas , Encaminhamento e Consulta , Feminino , Humanos , Recém-Nascido , Masculino , Reações Falso-Positivas , Perda Auditiva/congênito , Perda Auditiva/diagnóstico , Perda Auditiva/epidemiologia , Testes Auditivos/métodos , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas/fisiologia , Prevalência , Quebeque , Encaminhamento e Consulta/estatística & dados numéricos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Protocolos Clínicos
16.
J Assoc Res Otolaryngol ; 15(3): 319-34, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24452323

RESUMO

This paper presents in vivo experimental measurements of vibrations on the pars flaccida, along the manubrium and at several points on the pars tensa in the gerbil with open middle-ear cavity. The effects of progressive opening of the middle-ear cavity are presented, with up to five different extents of opening. In all manubrial, pars-tensa and pars-flaccida responses, opening the cavity causes an increase in the low-frequency magnitude and a shift of the main middle-ear resonance to lower frequencies and introduces an antiresonance. However, opening the cavity has little or no effect on either the mode of vibration of the manubrium or the breakup frequency of the pars tensa. When the opening is gradually widened, the antiresonance frequency moves to higher frequencies. When the opening is made as wide as anatomically possible, the antiresonance moves to almost 10 kHz. The main increase in the low-frequency response magnitude happens upon making the smallest hole in the cavity wall, and further progressive enlarging of the opening has little or no effect on the low-frequency magnitude. The antiresonance interferes with the response shapes. An identification method is suggested for eliminating the effect of the antiresonance in order to estimate the ideal open-cavity response. The method is validated and then applied to manubrial and pars-tensa responses. Estimating the ideal open-cavity responses will simplify comparison of the data with numerical models which do not include the air cavity. The data collected at intermediate stages of opening will be useful in validating models that do include the cavity.


Assuntos
Orelha Média/fisiologia , Membrana Timpânica/fisiologia , Vibração , Animais , Gerbillinae
17.
J Otolaryngol Head Neck Surg ; 43: 40, 2014 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-25927463

RESUMO

BACKGROUND: Endoscopic sinus surgery (ESS) is a technically challenging procedure, associated with a significant risk of complications. Virtual reality simulation has demonstrated benefit in many disciplines as an important educational tool for surgical training. Within the field of rhinology, there is a lack of ESS simulators with appropriate validity evidence supporting their integration into residency education. The objectives of this study are to evaluate the acceptability, perceived realism and benefit of the McGill Simulator for Endoscopic Sinus Surgery (MSESS) among medical students, otolaryngology residents and faculty, and to present evidence supporting its ability to differentiate users based on their level of training through the performance metrics. METHODS: 10 medical students, 10 junior residents, 10 senior residents and 3 expert sinus surgeons performed anterior ethmoidectomies, posterior ethmoidectomies and wide sphenoidotomies on the MSESS. Performance metrics related to quality (e.g. percentage of tissue removed), efficiency (e.g. time, path length, bimanual dexterity, etc.) and safety (e.g. contact with no-go zones, maximum applied force, etc.) were calculated. All users completed a post-simulation questionnaire related to realism, usefulness and perceived benefits of training on the MSESS. RESULTS: The MSESS was found to be realistic and useful for training surgical skills with scores of 7.97 ± 0.29 and 8.57 ± 0.69, respectively on a 10-point rating scale. Most students and residents (29/30) believed that it should be incorporated into their curriculum. There were significant differences between novice surgeons (10 medical students and 10 junior residents) and senior surgeons (10 senior residents and 3 sinus surgeons) in performance metrics related to quality (p < 0.05), efficiency (p < 0.01) and safety (p < 0.05). CONCLUSION: The MSESS demonstrated initial evidence supporting its use for residency education. This simulator may be a potential resource to help fill the void in endoscopic sinus surgery training.


Assuntos
Simulação por Computador , Currículo , Endoscopia/educação , Internato e Residência , Otolaringologia/educação , Seios Paranasais/cirurgia , Interface Usuário-Computador , Competência Clínica , Desenho de Equipamento , Humanos , Estudos Retrospectivos
18.
J Assoc Res Otolaryngol ; 14(4): 467-81, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23624883

RESUMO

The purpose of the present work is to investigate the spatial vibration pattern of the gerbil tympanic membrane (TM) as a function of frequency. In vivo vibration measurements were done at several locations on the pars flaccida and pars tensa, and along the manubrium, on surgically exposed gerbil TMs with closed middle ear cavities. A laser Doppler vibrometer was used to measure motions in response to audio frequency sine sweeps in the ear canal. Data are presented for two different pars flaccida conditions: naturally flat and retracted into the middle ear cavity. Resonance of the flat pars flaccida causes a minimum and a shallow maximum in the displacement magnitude of the manubrium and pars tensa at low frequencies. Compared with a flat pars flaccida, a retracted pars flaccida has much lower displacement magnitudes at low frequencies and does not affect the responses of the other points. All manubrial and pars tensa points show a broad resonance in the range of 1.6 to 2 kHz. Above this resonance, the displacement magnitudes of manubrial points, including the umbo, roll off with substantial irregularities. The manubrial points show an increasing displacement magnitude from the lateral process toward the umbo. Above 5 kHz, phase differences between points along the manubrium start to become more evident, which may indicate flexing of the tip of the manubrium or a change in the vibration mode of the malleus. At low frequencies, points on the posterior side of the pars tensa tend to show larger displacements than those on the anterior side. The simple low-frequency vibration pattern of the pars tensa becomes more complex at higher frequencies, with the breakup occurring at between 1.8 and 2.8 kHz. These observations will be important for the development and validation of middle ear finite-element models for the gerbil.


Assuntos
Orelha Média/fisiopatologia , Gerbillinae/fisiologia , Membrana Timpânica/fisiopatologia , Vibração , Animais , Feminino , Martelo/fisiopatologia , Microesferas , Modelos Animais , Plásticos
19.
Biomech Model Mechanobiol ; 12(4): 705-15, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22965177

RESUMO

Some biological tissues are repeatedly stimulated under cyclic loading, and this stimulation can be combined with large pressures, thus leading to large deformations. For such applications, visco-hyperelastic models have been proposed in the literature and used in finite-element studies. An extensively used quasi-linear model (QLVH), which assumes linear evolution equations, is compared with a nonlinear model (NLVH), which assumes a multiplicative split of the deformation gradient. The comparison is made here using sets of simulations covering a large frequency range. Lost and stored energies are computed, and the additional parameter of the NLVH model is set to two values found in the literature (NLVH-2 and NLVH-30 models). The predicted behaviour is very similar for all models at small strains, with each time constant (and corresponding viscous modulus) being associated with a damping peak and a stored-energy increase. When the strain amplitude is increased, the ratio of lost to stored energy increases for the QLVH model, but decreases for the NLVH models. The NLVH-30 model also displays a shift of the peak damping towards higher frequencies. Before reaching a steady state, all models display a decay of energy independent of the frequency, and the additional parameter of the NLVH model permits the modelling of complex types of evolution of the damping. In conclusion, this study compares the behaviour of two viscous hyper-elastic laws to allow an informed choice between them.


Assuntos
Elasticidade , Estresse Mecânico , Simulação por Computador , Modelos Lineares , Dinâmica não Linear , Reologia , Termodinâmica , Fatores de Tempo , Viscosidade
20.
J Acoust Soc Am ; 134(6): 4427, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25669254

RESUMO

The mechanical behavior of the tympanic membrane displays both non-linearity and viscoelasticity. Previous finite-element models of the tympanic membrane, however, have been either non-linear or viscoelastic but not both. In this study, these two features are combined in a non-linear viscoelastic model. The constitutive equation of this model is a convolution integral composed of a non-linear elastic part, represented by an Ogden hyperelastic model, and an exponential time-dependent part, represented by a Prony series. The model output is compared with the relaxation curves and hysteresis loops observed in previous measurements performed on strips of tympanic membrane. In addition, a frequency-domain analysis is performed based on the obtained material parameters, and the effect of strain rate is explored. The model presented here is suitable for modeling large deformations of the tympanic membrane for frequencies less than approximately 3 rad/s or about 0.6 Hz. These conditions correspond to the pressurization involved in tympanometry.


Assuntos
Mecanotransdução Celular , Modelos Biológicos , Membrana Timpânica/fisiologia , Simulação por Computador , Elasticidade , Análise de Elementos Finitos , Humanos , Movimento (Física) , Dinâmica não Linear , Pressão , Reprodutibilidade dos Testes , Som , Fatores de Tempo , Membrana Timpânica/anatomia & histologia , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA