Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Transfusion ; 64(1): 116-123, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088084

RESUMO

BACKGROUND: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) essentially affects respiratory organs and tissues. SARS-CoV-2 RNAemia is often associated with more severe cases of coronavirus disease 2019 (COVID-19) compared to cases without RNAemia. To determine the impact of the pandemic on transfusion medicine, particularly transfusion-related infection, we examined the frequency of blood donation with RNAemia, the viral RNA (vRNA) concentration, and any possibility of transfusion-transmitted infection (TTI) among transfusion recipients. STUDY DESIGN AND METHODS: vRNA was examined in plasma/serum samples from 496 of 513 blood donors who reported having been infected with SARS-CoV-2 within 2 weeks of donation among a total of ca. 9.9 million blood donations in Japan between January 15, 2020, and December 31, 2021. The clinical course of patients transfused with the blood component containing vRNA was also examined. RESULTS: vRNA was detected in 23 of 496 samples. The median period from blood donation to COVID-19 onset was 1 day in 16 RNAemia-positive donors. Most samples had vRNA concentrations below the limit of quantification. Three patients were transfused with either a packed red blood cell or platelet concentrate that tested positive for vRNA, showing no COVID-19 symptoms and testing negative for vRNA in post-transfusion blood. CONCLUSION: The rate of RNAemia was 4.6% among blood donors who were found to be infected with SARS-CoV-2 shortly after donation, and vRNA concentrations in their donated blood were extremely low. There was no evidence of TTI in the recipients transfused with RNAemia-positive blood components. TTI risk in SARS-CoV-2 is negligible.


Assuntos
COVID-19 , Reação Transfusional , Humanos , SARS-CoV-2 , COVID-19/epidemiologia , Doadores de Sangue , Japão/epidemiologia , RNA Viral
2.
Vox Sang ; 118(7): 582-586, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37191237

RESUMO

BACKGROUND: Transfusion-transmitted bacterial infections (TTBIs) in Japan have been largely prevented due to a short shelf life of 3.5 days after blood collection for platelet concentrate (PC) and washed PCs (WPCs; PC in which 95% plasma is replaced by platelet additive solution). CASE PRESENTATION: Case 1: In January 2018, a woman in her 50s with aplastic anaemia who received WPC transfusion and developed a fever the next day and Streptococcus dysgalactiae subspecies equisimilis (SDSE) was detected in the residual WPC. Case 2: In May 2018, a man in his 60s with a haematologic malignancy who received PC transfusion and developed chills during the transfusion. SDSE was detected in the patient's blood and residual PC. The contaminated platelet products were both manufactured from blood donated by the same donor. The multi-locus sequencing typing revealed that SDSE detected in case 1 was identical to that from case 2; however, whole blood subsequently obtained from the donor was culture negative. CONCLUSION: WPC and PC produced from two blood donated 106 days apart by the same donor were contaminated with SDSE of the same strain and both caused TTBIs. Safety measures should be considered regarding blood collection from a donor with a history of bacterial contamination.


Assuntos
Doação de Sangue , Reação Transfusional , Feminino , Humanos , Masculino , Bactérias , Transfusão de Sangue , Streptococcus , Pessoa de Meia-Idade
3.
Transfusion ; 63(6): 1250-1254, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37129363

RESUMO

BACKGROUND: Hepatitis B virus (HBV)-positive individuals with isolated anti-HBs are found among HBV vaccine recipients and healthy blood donors with no vaccination history. HBV infectivity from blood transfusions derived from such individuals remains unclear. CASE PRESENTATION: A male patient who received transfusion with blood negative for individual donation-NAT, HBsAg and anti-HBc but weakly positive for anti-HBs developed typical transfusion-transmitted (TT)-HBV with anti-HBc response. The responsible blood donor was a frequent repeat donor showing a marked increase in anti-HBs titer without anti-HBc response 84 days after index donation. Test results for his past donations showed transient viremia with very low viral load and fluctuating low-level anti-HBs. The HBV vaccination history of this donor was unknown. DISCUSSION: Anti-HBs and anti-HBc kinetics of the donor suggest a second antibody response to new HBV challenge, representing a vaccine breakthrough case. On the other hand, transient low-level viremia and fluctuating anti-HBs in the test results of past donations suggested chronic occult HBV infection with isolated anti-HBs. CONCLUSION: Whatever the basic infection state, blood donors with isolated weak anti-HBs may include a small population with a risk of causing TT-HBV. Identifying individuals harboring such TT-HBV risk among individuals positive only for anti-HBs is difficult under current screening strategies. Active surveillance for the occurrence of TT-HBV with blood positive only for anti-HBs is necessary.


Assuntos
Hepatite B Crônica , Hepatite B , Humanos , Masculino , Vírus da Hepatite B/genética , Viremia , Anticorpos Anti-Hepatite B , Antígenos de Superfície da Hepatite B , Antígenos do Núcleo do Vírus da Hepatite B , Vacinas contra Hepatite B , Doadores de Sangue , DNA Viral
4.
Transfusion ; 63(6): 1204-1214, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37119513

RESUMO

BACKGROUND: In Japan, plasma with a high concentration of Hepatitis B Virus (HBV) antibodies for hepatitis B immunoglobulin (HBIG) is almost entirely imported. We aimed to produce recombinant HBIG by isolating immunoglobulin cDNAs against the HBV surface antigen (HBsAg). STUDY DESIGN AND METHODS: B cells expressing HBsAg antibodies were obtained from blood center personnel who had been administered HB vaccine booster and then isolated by either an Epstein-Barr virus hybridoma or an antigen-specific memory B cell sorting method. Each cDNA of the heavy and light chains of the target antibody was cloned into an IgG1 expression vector and transfected into Expi293F cells to produce a recombinant monoclonal antibody (mAb), which was screened by ELISA and in vitro HBV neutralizing assays. The cross-reactivity of the mAbs to normal human molecules was evaluated by ELISA and immunohistochemistry. RESULTS: Antibody cDNAs were cloned from 11 hybridoma cell lines and 204 HBsAg-bound memory B cells. Three of the resulting recombinant mAbs showed stronger neutralizing activity in vitro than the currently used HBIG. All three bind to the conformational epitope(s) of HBsAg but not to human DNA or cells. DISCUSSION: We successfully isolated HBV-neutralizing monoclonal antibodies from B cells collected from healthy plasma donors boosted against the HBV. To obtain an alternative source for HBIG, HBV-neutralizing monoclonal antibodies from B cells collected from healthy plasma donors boosted against the HBV may be useful.


Assuntos
Infecções por Vírus Epstein-Barr , Hepatite B , Humanos , Antígenos de Superfície da Hepatite B , Vírus da Hepatite B/genética , Estudos de Viabilidade , Herpesvirus Humano 4 , Vacinas contra Hepatite B , Anticorpos Anti-Hepatite B , Anticorpos Monoclonais , Proteínas Recombinantes , Hepatite B/prevenção & controle
5.
Retrovirology ; 19(1): 7, 2022 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-35585539

RESUMO

BACKGROUND: The potential risk and association of bovine leukemia virus (BLV) with human remains controversial as it has been reported to be both positive and negative in human breast cancer and blood samples. Therefore, establishing the presence of BLV in comprehensive human clinical samples in different geographical locations is essential. RESULT: In this study, we examined the presence of BLV proviral DNA in human blood and breast cancer tissue specimens from Japan. PCR analysis of BLV provirus in 97 Japanese human blood samples and 23 breast cancer tissues showed negative result for all samples tested using long-fragment PCR and highly-sensitive short-fragment PCR amplification. No IgG and IgM antibodies were detected in any of the 97 human serum samples using BLV gp51 and p24 indirect ELISA test. Western blot analysis also showed negative result for IgG and IgM antibodies in all tested human serum samples. CONCLUSION: Our results indicate that Japanese human specimens including 97 human blood, 23 breast cancer tissues, and 97 serum samples were negative for BLV.


Assuntos
Anticorpos Antivirais , DNA Viral , Vírus da Leucemia Bovina , Provírus , Anticorpos Antivirais/isolamento & purificação , Sangue/virologia , Neoplasias da Mama/virologia , DNA Viral/isolamento & purificação , Feminino , Humanos , Imunoglobulina G/isolamento & purificação , Imunoglobulina M/isolamento & purificação , Japão , Vírus da Leucemia Bovina/genética , Vírus da Leucemia Bovina/imunologia , Provírus/genética
6.
Transfusion ; 62(3): 621-632, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35045189

RESUMO

BACKGROUND: Bacterial contamination in platelet concentrates (PCs) is a major problem in transfusion medicine. Contamination with Staphylococcus aureus is occasionally missed, even with cultural screening. STUDY DESIGN AND METHODS: Donors implicated in S. aureus-contaminated PC were followed up. Skin and nasal swab specimens from six donors and S. aureus isolated from PCs related to these donors were subjected to multilocus sequence typing (MLST) and pulsed-field gel electrophoresis (PFGE) to determine the identity of bacteria. To evaluate the validity of the screening method using BacT/ALERT 3D, we spiked S. aureus and three other bacterial species as comparisons into PCs and investigated their growth pattern. RESULTS: S. aureus was isolated from all nasal specimens and from the arm skin specimens of three donors with atopic dermatitis. In all cases, the S. aureus strains isolated from the PC and those from the nasal and skin specimens of the same donor showed concordant results using MLST and PFGE. In the spiking study, S. aureus showed irregular detectability over 24 to 48 h post-spike periods, whereas the three other bacterial species were detected in all culture bottles after a 24-h post-spike period. DISCUSSION: The strain identity of S. aureus between donor and PC suggests that the contaminants were derived from those colonized in the donor. Furthermore, S. aureus yielded false-negative results using BacT/ALERT 3D.


Assuntos
Dermatopatias , Infecções Estafilocócicas , Bactérias , Doadores de Sangue , Plaquetas/microbiologia , Humanos , Tipagem de Sequências Multilocus , Infecções Estafilocócicas/diagnóstico , Staphylococcus aureus
7.
Sci Rep ; 11(1): 12134, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-34108521

RESUMO

Tetanus is a fatal disease caused by tetanus neurotoxin (TeNT). TeNT is composed of a light chain (Lc) and a heavy chain, the latter of which is classified into two domains, N-terminus Hn and C-terminus Hc. Several TeNT-neutralizing antibodies have been reported, but it remains unclear which TeNT domains are involved in neutralization. To further understand the mechanism of these antibodies, we isolated TeNT-reactive human antibody clones from peripheral blood mononuclear cells. We then analyzed the reactivity of the isolated antibody clones to each protein domain and their inhibition of Hc-ganglioside GT1b binding, which is critical for TeNT toxicity. We also investigated the TeNT-neutralizing ability of isolated antibody clones and showed that an Hn-reactive clone protected strongly against TeNT toxicity in mice. Furthermore, combination treatment of Hn-reactive antibody clones with both Hc-reactive and TeNT mix (the mixture of Hc, Hn, and Lc proteins)-reactive antibody clones enhanced the neutralizing effect. These results indicated that antibody clones targeting Hn effectively neutralized TeNT. In addition, the use of a cocktail composed of Hc-, Hn-, and TeNT mix-reactive antibodies provided enhanced protection compared to the use of each antibody alone.


Assuntos
Anticorpos Antibacterianos/imunologia , Anticorpos Monoclonais/imunologia , Anticorpos Neutralizantes/imunologia , Clostridium tetani/isolamento & purificação , Leucócitos Mononucleares/imunologia , Metaloendopeptidases/imunologia , Toxina Tetânica/imunologia , Tétano/imunologia , Animais , Anticorpos Antibacterianos/sangue , Anticorpos Monoclonais/sangue , Anticorpos Neutralizantes/sangue , Humanos , Camundongos , Tétano/sangue , Tétano/microbiologia
8.
PLoS One ; 16(5): e0251650, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34014978

RESUMO

The risk of sepsis through bacterial transmission is one of the most serious problems in platelet transfusion. In processing platelet concentrates (PCs), several methods have been put into practice to minimize the risk of bacterial transmission, such as stringent monitoring by cultivation assays and inactivation treatment by photoirradiation with or without chemical agents. As another potential option, we applied a light-emitting diode (LED) with a peak emission wavelength of 265 nm, which has been shown to be effective for water, to disinfect PCs. In a bench-scale UV-LED exposure setup, a 10-min irradiation, corresponding to an average fluence of 9.2 mJ/cm2, resulted in >2.0 log, 1.0 log, and 0.6 log inactivation (mean, n = 6) of Escherichia coli, Staphylococcus aureus, and Bacillus cereus, respectively, in non-diluted plasma PCs. After a 30-min exposure, platelet counts decreased slightly (18 ± 7%: mean ± SD, n = 7); however, platelet surface expressions of CD42b, CD61, CD62P, and PAC-1 binding did not change significantly (P>0.005), and agonist-induced aggregation and adhesion/aggregation under flow conditions were well maintained. Our findings indicated that the 265 nm UV-LED has high potential as a novel disinfection method to ensure the microbial safety of platelet transfusion.


Assuntos
Bactérias/crescimento & desenvolvimento , Plaquetas , Desinfecção , Viabilidade Microbiana/efeitos da radiação , Raios Ultravioleta , Plaquetas/metabolismo , Plaquetas/microbiologia , Humanos
9.
Vox Sang ; 115(2): 159-166, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31769038

RESUMO

BACKGROUND AND OBJECTIVES: Although HLA-eliminated platelets can facilitate transfusions to patients possessing HLA antibodies, no such products are currently available commercially perhaps because the platelet collection rate is not yet economically viable. We have improved this process' efficiency by employing a hollow-fibre system at the last step of the production process after an acid and a reaction buffer have been washed out conventionally by centrifugation. MATERIALS AND METHODS: HLA-eliminated platelets were prepared via four distinct steps: chilled on ice, treated with an acid solution, diluted and finally washed using the hollow-fibre system. The efficiency of this platelet recovery process was determined. The resulting products' platelet characteristics, including a capacity for HLA expression, were evaluated in vitro and compared in detail to their corresponding originals. RESULTS: The average efficiency of platelet recovery was 91%. Although the expression levels of CD62P, a molecular marker for platelet activation, were approximately threefold higher on new platelets than on the original platelets, their HLA expression levels were lower. The phagocytosis assay, with monoclonal antibodies and cognate HLA antibody-containing sera, suggested that HLA-ABC molecules on the cell surface were sufficiently removed. The platelet functions, including the agonist-induced aggregability and adherence/aggregability of the collagen-coated plates under certain conditions, were conserved and not significantly different from the original ones. CONCLUSION: We propose a novel preparation system for producing HLA-eliminated platelets without centrifugation, which ensures a highly efficient, and therefore, much more economical method of platelet recovery that also retains their key functionality.


Assuntos
Plaquetas/citologia , Separação Celular/métodos , Anticorpos Monoclonais/imunologia , Plaquetas/imunologia , Separação Celular/instrumentação , Separação Celular/normas , Centrifugação/efeitos adversos , Antígenos HLA/imunologia , Humanos , Selectina-P/genética , Selectina-P/metabolismo , Ativação Plaquetária
10.
Transfusion ; 57(9): 2084-2095, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28656655

RESUMO

BACKGROUND: In previous studies, we demonstrated that the basophil activation test, which is performed using patient blood and the supernatants from transfused blood components, was able to elucidate not only the causative relationship between allergic transfusion reactions and the transfusion but also the mechanisms behind allergic transfusion reactions. However, for a large number of allergic transfusion reactions, patients are in a state of myelosuppression, and the basophil activation test cannot be performed for these patients because there are insufficient numbers of peripheral blood basophils. STUDY DESIGN AND METHODS: To overcome this obstacle, we developed a passive immune basophil activation test, in which patient plasma and residually transfused blood are used as the patient's sources of immunoglobulin E and allergen, respectively, whereas healthy volunteer basophils serve as the responder cell source. The passive immune basophil activation test was performed for two patients who had severe allergic transfusion reactions, using supernatants of the residual platelet concentrates and the patients' own immunoglobulin E. RESULTS: There were no differences in either surface immunoglobulin E or activation in response to allergens between untreated basophils and so-called quasi-basophils, in which immunoglobulin E was replaced by a third party's immunoglobulin E. In these patients, the supernatants of the residual platelet concentrates exclusively activated basophils in response to quasi-basophils onto which the patients' immunoglobulin E, but not a third party's immunoglobulin E, was bound. CONCLUSION: The passive immune basophil activation test may help clarify the causal relationship between allergic transfusion reactions and transfused blood, even when patients experience myelosuppression.


Assuntos
Basófilos/imunologia , Plaquetas/imunologia , Hipersensibilidade Imediata/prevenção & controle , Reação Transfusional , Reação Transfusional/imunologia , Alérgenos/sangue , Basófilos/citologia , Humanos , Hipersensibilidade Imediata/imunologia , Imunoglobulina E , Reação Transfusional/etiologia
11.
Transfusion ; 56(5): 1201-12, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26920340

RESUMO

BACKGROUND: Platelet concentrates (PCs) are the most common blood components eliciting nonhemolytic transfusion reactions (NHTRs), such as allergic transfusion reactions and febrile reactions. However, the precise mechanisms of NHTRs in PC transfusion remain largely unknown. Previous studies reported that mitochondria-derived damage-associated molecular patterns (DAMPs) could be important mediators of innate cell inflammation. Platelets (PLTs) represent a major reservoir of mitochondria in the blood circulation. The aim of this study was to determine the possible involvement of mitochondrial DAMPs in NHTRs. STUDY DESIGN AND METHODS: The amount of mitochondrial DAMPs was determined as an index of total copy numbers of mitochondrial DNA (mtDNA), including mtDNA itself and free mitochondria, using quantitative real-time polymerase chain reaction. To examine whether neutrophils, monocytes, and basophils were activated by mitochondrial DAMPs in vitro, an in vitro whole blood cell culture assay was performed. RESULTS: In blood components associated with NHTRs, the mean total mtDNA concentration was highest in PCs followed in order by fresh-frozen plasma and red blood cells. The amount of mtDNA in NHTR PCs was higher than that in control PCs without NHTRs. The mitochondrial DAMPs present in NHTR PCs was high enough to activate neutrophils, monocytes, and basophils, when costimulated with N-formyl-l-methionyl-l-leucyl-l-phenylalanine or HLA antibodies. CONCLUSION: PLT-derived mitochondrial DAMPs are candidate risk factors for the onset of NHTRs.


Assuntos
Plaquetas/ultraestrutura , DNA Mitocondrial/análise , Mitocôndrias/genética , Transfusão de Plaquetas/efeitos adversos , Reação Transfusional/etiologia , Basófilos/imunologia , Segurança do Sangue , DNA Mitocondrial/genética , Humanos , Fenômenos do Sistema Imunitário , Mediadores da Inflamação , Japão , Monócitos/imunologia , Neutrófilos/imunologia
12.
Immunohematology ; 31(1): 7-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26308464

RESUMO

Human neutrophil antigen (HNA)-typed granulocyte panels are widely used to screen for the presence of HNA antibodies and to determine antibody specificity. Many laboratories screen donors for HNA genotypes using low-throughput methods such as allele-specific polymerase chain reaction (PCR), PCR-restriction fragment-length polymorphism, and multiplex PCR. In the present study, we used a high-resolution melting (HRM) analysis to determine HNA genotypes. For the HRM analysis, purified genomic DNA samples were amplified via PCR with HNA-specific primers. Nucleotide substitutions in genes encoding HNAs were differentiated on the basis of the HRM curves, and the results of HRM and DNA sequencing analyses were determined to be in complete agreement. The gene frequency of HNA-1a, -1b, -1c, -3a, -3b, -4a, -4b, -5a, and -5b in the Japanese population was consistent with the previous reports. Our results suggest that HRM analysis can be used for genotyping HNA antigens determined by single nucleotide substitutions.


Assuntos
Frequência do Gene , Técnicas de Genotipagem , Isoantígenos/genética , Neutrófilos , Reação em Cadeia da Polimerase , Polimorfismo de Nucleotídeo Único , Povo Asiático , Feminino , Humanos , Japão , Masculino
13.
Int J Hematol ; 102(1): 93-100, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25840771

RESUMO

On transfusion, several plasma proteins can cause anaphylaxis in patients deficient in the corresponding plasma proteins. However, little is known about other allergens, which are encountered much more infrequently. Although it has been speculated that an allergen-independent pathway underlying allergic transfusion reactions (ATRs) is elicited by biological response modifiers accumulated in blood components during storage, the exact mechanisms remain unresolved. Furthermore, it is difficult even to determine whether ATRs are induced via allergen-dependent or allergen-independent pathways. To distinguish these two pathways in ATR cases, we established a basophil activation test, in which the basophil-activating ability of supernatants of residual transfused blood of ATR cases to whole blood basophils was assessed in the presence or absence of dasatinib, an inhibitor of IgE-mediated basophil activation. Three of 37 supernatants from the platelet concentrates with ATRs activated panel blood basophils in the absence, but not in the presence, of dasatinib. The basophil activation was inhibited by treatment of anti-fish collagen I MoAb in one case, suggesting that the involvement of fish allergens may have been present in donor plasma. We concluded that unknown non-plasma proteins, some of which had epitopes similar to fish antigens, in blood component may be involved in ATRs via an allergen/IgE-dependent pathway.


Assuntos
Alérgenos/imunologia , Hipersensibilidade Imediata/imunologia , Reação Transfusional/imunologia , Basófilos/efeitos dos fármacos , Basófilos/imunologia , Basófilos/metabolismo , Antígenos de Grupos Sanguíneos/imunologia , Proteínas Sanguíneas/imunologia , Dasatinibe/farmacologia , Humanos , Hipersensibilidade Imediata/diagnóstico , Transfusão de Plaquetas/efeitos adversos , Inibidores de Proteínas Quinases/farmacologia , Reação Transfusional/diagnóstico
14.
Transfusion ; 55(8): 1889-99, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25721073

RESUMO

BACKGROUND: In Japanese Red Cross (JRC) blood centers, blood collected from donors with serum alanine aminotransferase (ALT) levels of more than 60 U/L are disqualified even if serologically negative for transfusion-transmitted infections (TTIs). To assess potential risks of TTIs in plasma with elevated serum ALT levels in the current donor screening program of the JRC, we conducted a metagenomic analysis (MGA) of virome profiles in the plasma of blood donors with or without elevated serum ALT levels. STUDY DESIGN AND METHODS: Based on serum ALT levels, donors were classified into three groups: "high," more than 79 U/L; "middle," 61 to 79 U/L; and "low," less than 61 U/L. We individually analyzed 100 plasma samples from each group by MGA, employing shotgun sequencing. Viral sequences detected using MGA were partly confirmed using real-time polymerase chain reaction (PCR). RESULTS: Donors with high and middle ALT levels were significantly younger than those with low ALT levels, and more than 90% were males. Herpesviridae, Anelloviridae, Picornaviridae, and Flaviviridae sequences were identified in plasma samples, and their distribution and frequency were not significantly different among the three groups. CONCLUSION: The serum ALT test may be unsuitable for monitoring for additional risks of TTIs in blood donors who were negative for typical TTIs using serologic and nucleic acid tests. Although MGA is less sensitive than PCR, it remains the best technology to detect known viruses in these donors.


Assuntos
Alanina Transaminase/sangue , Doadores de Sangue , Segurança do Sangue , Genoma Viral , Metagenômica/métodos , Plasma/virologia , Adolescente , Adulto , Idoso , Anelloviridae/genética , Anelloviridae/isolamento & purificação , Patógenos Transmitidos pelo Sangue , DNA Viral/genética , Feminino , Flaviviridae/genética , Flaviviridae/isolamento & purificação , Herpesviridae/genética , Herpesviridae/isolamento & purificação , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Picornaviridae/genética , Picornaviridae/isolamento & purificação , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real , Análise de Sequência de DNA , Análise de Sequência de RNA , Viremia/enzimologia , Viremia/virologia , Adulto Jovem
15.
Transfusion ; 55(4): 880-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25363675

RESUMO

BACKGROUND: Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. STUDY DESIGN AND METHODS: Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. RESULTS: In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. CONCLUSION: Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies.


Assuntos
Doadores de Sangue , Segurança do Sangue/métodos , Seleção do Doador/métodos , Anticorpos Anti-HTLV-I/sangue , Infecções por HTLV-I/diagnóstico , Vírus Linfotrópico T Tipo 1 Humano/isolamento & purificação , Viremia/diagnóstico , Fatores de Transcrição de Zíper de Leucina Básica/imunologia , Western Blotting , Seleção do Doador/legislação & jurisprudência , Ensaio de Imunoadsorção Enzimática , Reações Falso-Negativas , Reações Falso-Positivas , Genes Reporter , Vetores Genéticos , Células HEK293 , Antígenos HTLV-I/genética , Antígenos HTLV-I/imunologia , Infecções por HTLV-I/sangue , Infecções por HTLV-I/epidemiologia , Infecções por HTLV-I/prevenção & controle , Infecções por HTLV-I/virologia , Vírus Linfotrópico T Tipo 1 Humano/imunologia , Humanos , Imunoprecipitação , Japão/epidemiologia , Luciferases de Renilla/análise , Luciferases de Renilla/genética , Medições Luminescentes , Valor Preditivo dos Testes , Proteínas dos Retroviridae/imunologia , Sensibilidade e Especificidade , Viremia/virologia
16.
Transfusion ; 53(10 Pt 2): 2545-55, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23590180

RESUMO

BACKGROUND: The risk of transferring blood-borne infections during transfusion is continually increasing because of newly emerging and reemerging viruses. Development of a rapid screening method for emerging viruses that might be transmitted by transfusion is required to eliminate such pathogens during blood donor screening. Owing to increased use of human materials in organ transplants and cell therapy, the risk of donor-transmitted viral infections is also increasing. Although nucleic acid amplification technology (NAT) is dedicated to blood screening, a small, convenient detection system is needed at the laboratory and hospital level. STUDY DESIGN AND METHODS: We developed a new pathogen detection system that can detect multiple viruses simultaneously, using originally designed degenerate polymerase chain reaction primers to amplify a wide range of viral genotypes. Amplified samples were identified using a DNA microarray of pathogen-specific probes. RESULTS: We detected very low copy numbers of multiple subtypes of viruses, such as human hepatitis C virus (HCV), human hepatitis B virus (HBV), human parvovirus B19 (PVB19), and West Nile virus (WNV), using a single plate. We also detected all genotypes of human immunodeficiency virus (HIV) but sensitivity was less than for the other viruses. CONCLUSION: We developed a microarray assay using novel primers for detection of a wide range of multiple pathogens and subtypes. Our NAT system was accurate and reliable for detection of HIV, HBV, HCV, PVB19, and WNV, with respect to specificity, sensitivity, and genotype inclusivity. Our system could be customized and extended for emerging pathogens and is suitable as a future NAT system.


Assuntos
Doadores de Sangue , Programas de Rastreamento/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Reação em Cadeia da Polimerase/métodos , Vírus/isolamento & purificação , Patógenos Transmitidos pelo Sangue/isolamento & purificação , Primers do DNA/genética , DNA Viral/genética , DNA Viral/isolamento & purificação , Genótipo , Humanos , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Sensibilidade e Especificidade , Vírus/genética , Organização Mundial da Saúde
17.
Jpn J Infect Dis ; 65(4): 334-6, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22814159

RESUMO

The xenotropic murine leukemia virus-related virus (XMRV) was first described as a novel human gammaretrovirus in prostate tumor tissues and was reported to be found in blood, suggesting the possibility of XMRV transmission via blood transfusion. The gag and env regions of the XMRV proviral DNA that were detected 1,030 blood samples collected from the greater Tokyo area were examined by real-time PCR analysis. However, XMRV infection was not found in the samples; this suggested that the risk of XMRV transmission via transfusion is very low in Japan.


Assuntos
DNA Viral/sangue , Provírus/genética , Vírus Relacionado ao Vírus Xenotrópico da Leucemia Murina/genética , Adolescente , Adulto , Idoso , Animais , Doadores de Sangue , Feminino , Genes env , Genes gag , Genoma Humano , Humanos , Masculino , Camundongos , Pessoa de Meia-Idade , Integração Viral , Adulto Jovem
19.
Retrovirology ; 8: 20, 2011 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-21414229

RESUMO

BACKGROUND: The involvement of xenotropic murine leukemia virus-related virus (XMRV) in prostate cancer (PC) and chronic fatigue syndrome (CFS) is disputed as its reported prevalence ranges from 0% to 25% in PC cases and from 0% to more than 80% in CFS cases. To evaluate the risk of XMRV infection during blood transfusion in Japan, we screened three populations--healthy donors (n = 500), patients with PC (n = 67), and patients with CFS (n = 100)--for antibodies against XMRV proteins in freshly collected blood samples. We also examined blood samples of viral antibody-positive patients with PC and all (both antibody-positive and antibody-negative) patients with CFS for XMRV DNA. RESULTS: Antibody screening by immunoblot analysis showed that a fraction of the cases (1.6-3.0%) possessed anti-Gag antibodies regardless of their gender or disease condition. Most of these antibodies were highly specific to XMRV Gag capsid protein, but none of the individuals in the three tested populations retained strong antibody responses to multiple XMRV proteins. In the viral antibody-positive PC patients, we occasionally detected XMRV genes in plasma and peripheral blood mononuclear cells but failed to isolate an infectious or full-length XMRV. Further, all CFS patients tested negative for XMRV DNA in peripheral blood mononuclear cells. CONCLUSION: Our data show no solid evidence of XMRV infection in any of the three populations tested, implying that there is no association between the onset of PC or CFS and XMRV infection in Japan. However, the lack of adequate human specimens as a positive control in Ab screening and the limited sample size do not allow us to draw a firm conclusion.


Assuntos
Anticorpos Antivirais/sangue , Síndrome de Fadiga Crônica/virologia , Neoplasias da Próstata/virologia , RNA Viral/sangue , Infecções por Retroviridae/complicações , Vírus Relacionado ao Vírus Xenotrópico da Leucemia Murina/isolamento & purificação , Animais , Doadores de Sangue , Linhagem Celular , Feminino , Humanos , Immunoblotting , Japão , Masculino , Camundongos , Vírus da Leucemia Murina de Moloney/imunologia , Infecções por Retroviridae/virologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Reação Transfusional , Vírus Relacionado ao Vírus Xenotrópico da Leucemia Murina/genética , Vírus Relacionado ao Vírus Xenotrópico da Leucemia Murina/imunologia
20.
Retrovirology ; 7: 110, 2010 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-21171978

RESUMO

During pilot studies to investigate the presence of viral RNA of xenotropic murine leukemia virus (MLV)-related virus (XMRV) infection in sera from chronic fatigue syndrome (CFS) patients in Japan, a positive band was frequently detected at the expected product size in negative control samples when detecting a partial gag region of XMRV using a one-step RT-PCR kit. We suspected that the kit itself might have been contaminated with small traces of endogenous MLV genome or XMRV and attempted to evaluate the quality of the kit in two independent laboratories. We purchased four one-step RT-PCR kits from Invitrogen, TaKaRa, Promega and QIAGEN in Japan. To amplify the partial gag gene of XMRV or other MLV-related viruses, primer sets (419F and 1154R, and GAG-I-F and GAG-I-R) which have been widely used in XMRV studies were employed. The nucleotide sequences of the amplicons were determined and compared with deposited sequences of a polytropic endogenous MLV (PmERV), XMRV and endogenous MLV-related viruses derived from CFS patients. We found that the enzyme mixtures of the one-step RT-PCR kit from Invitrogen were contaminated with RNA derived from PmERV. The nucleotide sequence of a partial gag region of the contaminant amplified by RT-PCR was nearly identical (99.4% identity) to a PmERV on chromosome 7 and highly similar (96.9 to 97.6%) to recently identified MLV-like viruses derived from CFS patients. We also determined the nucleotide sequence of a partial env region of the contaminant and found that it was almost identical (99.6%) to the PmERV. In the investigation of XMRV infection in patients of CFS and prostate cancer, researchers should prudently evaluate the test kits for the presence of endogenous MLV as well as XMRV genomes prior to PCR and RT-PCR tests.


Assuntos
Retrovirus Endógenos/isolamento & purificação , Genoma Viral , Vírus da Leucemia Murina/isolamento & purificação , Kit de Reagentes para Diagnóstico/virologia , Vírus Relacionado ao Vírus Xenotrópico da Leucemia Murina/isolamento & purificação , Sequência de Bases , Primers do DNA/genética , Retrovirus Endógenos/genética , Síndrome de Fadiga Crônica/genética , Síndrome de Fadiga Crônica/virologia , Humanos , Japão , Vírus da Leucemia Murina/genética , Dados de Sequência Molecular , Kit de Reagentes para Diagnóstico/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Vírus Relacionado ao Vírus Xenotrópico da Leucemia Murina/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA