Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Lab Med ; 8(5): 1006-1007, 2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37673663
2.
Adv Lab Med ; 3(2): 175-200, 2022 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37361871

RESUMO

Objectives: Most errors in laboratory medicine occur in the pre- and post-analytical phases of the total testing process (TTP). In 2014, the Spanish Society of Laboratory Medicine (SEQCML) started the current Preanalytical Phase EQA Programme, with the objective of providing a tool for the improvement of the preanalytical phase. The aim of this study was to review the evolution of quality indicators (QI) and the comparability of established performance specifications (PS) with other EQA programmes. Methods: In the SEQCML programme, participants were asked to register rejections of the main specimens and the causes for rejections. Data collected from 2014 to 2017, and then reviewed biennially (2018-2019), was used to calculate the percentiles; p25, p50, p75, and p90 for every round, and their means were set as PS. These PS were compared with the results of other programmes. Results: The evolution of QI results for 2018-2019 period showed general maintenance or improvement, e.g., a significant decrease in the number of serum samples with a haemolytic index ≥0.5 g/L, except for EDTA and citrate samples handle, maybe for an improvement in detection. The comparison with PS for the QI of the IFCC Working Group "Laboratory Errors and Patient Safety" and the Key Incident Management and Monitoring System (KIMMS) programme of the RCPA showed comparable results, supporting the validity of the established specifications. Conclusions: The PS obtained are a helpful tool for benchmarking and to identify processes of the preanalytical phase whose improvement should be set as a priority.

3.
Clin Lab ; 60(11): 1859-64, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25648027

RESUMO

BACKGROUND: IGF-I is a clinically relevant protein in the diagnosis and monitoring of treatment of growth disor- ders. The Growth Hormone Research Society and the International IGF Research Society have encouraged the adoption of a universal calibration for immunoassays to improve standardization of IGF-I measurements, but currently commercial assays are calibrated either against the old WHO IRR 87/518 or the new WHO 02/254. We compared two IGF-I immunochemiluminescent assays: IMMULITE® 2000 (Siemens) and LIAISON® (DiaSorin), which differ in their standardization, and verified their precision according to quality specifications based on biological variation and their linear range. METHODS: 62 patient serum samples were analyzed for both assays and compared according to standards of the Clinical and Laboratory Standards Institute (CLSI), EP9-A2-IR. Precision was verified according to CLSI EP15- A2. Optimal coefficient of variation (CVo) and desirable coefficient of variation (CVd) for IGF-I assays were calculated as quality specifications based on the biological variability, in order to assess if the interassay analytical CV (CVa1) in the two methods were appropriate. Two dilution series using the 1st WHO International Standard (WHO IS) for IGF-I 02/254 were used to verify and compare the linearity range. RESULTS: The regression analysis showed constant and proportional differences for serum samples (slope b = 0.8115 (CI 95% CI; 0.7575-0.8556); intercept a = 33.6873 (95% CI: 23.3613-44.0133) between assays and similar pro- portional differences for WHO IS 02/254 standard dilutions series (slope b = 0.8024 (CI 95% CI; 0.7560-0.8616); intercept a = 6.9623 (95% CI: -2.0819-18.4383) between assays. Within-laboratory coefficients of variation for low and high levels were 2.82% and 3.80% for IMMULITE® 2000 and 3.58% and 2.14% for LIAISON®, respecttively. CONCLUSIONS: IGF-I concentrations measured by both assays are not transferable. The results emphasize the need to express IGF-I concentrations in standard deviation score (SDS) according to a matched normal population of the same age and gender. Within-laboratory precision in both methods met quality specifications derived from biological variation.


Assuntos
Imunoensaio/métodos , Fator de Crescimento Insulin-Like I/análise , Adolescente , Adulto , Automação Laboratorial , Biomarcadores/sangue , Criança , Feminino , Humanos , Imunoensaio/normas , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA