Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Transplant Proc ; 53(4): 1160-1168, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33483166

RESUMO

BACKGROUND: The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has raised concern for the health of immunocompromised individuals, who are potentially at higher risk of more severe infection and poorer outcomes. As a large London transplant center serving a diverse patient population, we report the outcomes of SARS-CoV-2 infection in our cohort of 2848 kidney and/or pancreas transplant patients. METHODS: Data were obtained retrospectively for all transplant patients who attended hospital during the peak of the pandemic and had a positive nasopharyngeal SARS-CoV-2 test. RESULTS: Sixty-six patients were found to be positive for SARS-CoV-2. Twenty percent were treated as outpatients, 59% were admitted to the general ward, and 21% required intensive care. Treatment consisted of reduced immunosuppression, antibiotics for pneumonia or sepsis, and other supportive treatments. Within our cohort, 12 patients died (18%), with an overall mortality of 0.4%. Predictive risk factors for COVID-19 severity were explored. CONCLUSIONS: Severe disease was associated with lower hemoglobin prior to COVID-19 diagnosis and lower lymphocyte count at the time of diagnosis but not age, sex, ethnicity, or preexisting comorbidities. Lower glomerular filtration rate and higher C-reactive protein were associated with more severe disease. Despite no use of hydroxychloroquine, azithromycin, antiviral, or immunomodulatory medications, our mortality rate (kidney and pancreas transplant patients) is similar to current international rates.


Assuntos
COVID-19/epidemiologia , Hospedeiro Imunocomprometido/imunologia , Transplante de Rim/efeitos adversos , Transplante de Pâncreas/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , SARS-CoV-2/imunologia , Adulto , Idoso , COVID-19/imunologia , COVID-19/virologia , Comorbidade , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Terapia de Imunossupressão/efeitos adversos , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/imunologia , Complicações Pós-Operatórias/virologia , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Reino Unido/epidemiologia
2.
EuroIntervention ; 8(12): 1372-8, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23360653

RESUMO

AIMS: The haemodynamic effect of mitral valve (MV) repair using multiple MitraClips® (MC) has not been investigated. The aim of the study was to evaluate the stress performance of MV repair with MC. METHODS AND RESULTS: Twenty consecutive patients (77±7 years, 13 men [65%]) after implantation of >2 MitraClips® were subsequently evaluated with dobutamine stress echocardiography (DSE). After MC implantation, mean transmitral pressure gradient (TPG) (3.3±0.8 mmHg vs. 4.0±0.6 mmHg; p<0.001) and mitral valve orifice area (2.9±0.3 cm2 vs. 3.9±0.4 cm2; p<0.001) were significantly increased during DSE showing a physiological behaviour effect of the MV. LVEF (41±18% vs. 46±21%; p<0.001) and systolic pulmonary artery pressure (42±11 mmHg vs. 44±12 mmHg; p=0.014) increased significantly. The degree of MR was stable during stress (p=0.68). At linear regression, only baseline peak TPG was related to stress mean TPG (p<0.001; Beta 0.816; 95% CI: 0.368-0.918). CONCLUSIONS: MV repair using MitraClips® should be performed with the aim of maximal reduction of MR degree. MV repair using MC may not lead to pathological degrees of MV stenosis. Although the TPG is significantly increased during stress, it never reaches pathological levels and is always accompanied by a significant increase in MVOA. The degree of residual MR remains unchanged during maximal pharmacological stress.


Assuntos
Cateterismo Cardíaco/instrumentação , Ecocardiografia sob Estresse , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Valva Mitral/diagnóstico por imagem , Instrumentos Cirúrgicos , Idoso , Idoso de 80 Anos ou mais , Pressão Arterial , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Humanos , Modelos Lineares , Masculino , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/etiologia , Análise Multivariada , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
Can J Cardiol ; 29(2): 255.e1-3, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22840299

RESUMO

The results of the Endovascular Valve Edge-to-Edge Repair Study (EVEREST) II trial have demonstrated that percutaneous mitral valve repair using the MitraClip in high-risk patients was associated favourable outcomes. However, commonly accepted contraindications for the standard MitraClip procedure include extensively prolapsed valves and flail leaflets. We report on the management of a patient not amenable to standard interventional procedure.


Assuntos
Adenosina/uso terapêutico , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/instrumentação , Insuficiência da Valva Mitral/terapia , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Humanos , Masculino , Desenho de Prótese , Índice de Gravidade de Doença
4.
Catheter Cardiovasc Interv ; 81(4): 609-17, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22887450

RESUMO

OBJECTIVES: We undertook this study to investigate the mid-term clinical results after MitraClip® implantation and the impact of post-repair mitral valve (MV) function and anatomy on survival and outcome composite endpoint in high-risk patients. BACKGROUND: Percutaneous MV repair is a potential treatment option for high-risk patients with severe mitral regurgitation (MR). METHODS: MitraClip® was implanted in patients with symptomatic MR rejected to conventional surgery. Differences between patients that survived at follow-up and patients deceased were tested. A stepwise Cox multivariate analysis was performed to identify independent predictors for composite endpoint of mortality, cardiac re-hospitalization, re-intervention, and major cerebro-vascular and cardiac events. RESULTS: A total of 85 consecutive patients [78 ± 6 years, 48 (56.5%) men] with severe MR were included. There was no operative mortality while in-hospital mortality was 3.5% (n = 3) and 30-day mortality 4.7% (n = 4). Follow-up was 211 ± 173 days. Survival and composite endpoint-free survival at one year were 71% and 55%. Multivariate analysis revealed that residual MR immediately after MitraClip® placement (OR 7.4; 95% CI 2.3-23.7) and preoperative MV gradient (OR 2.7; 95% CI 1.5-5.0) were predictors for composite endpoint. Chronic obstructive pulmonary disease (OR 8.3; 95% CI 1.9-37.1) was an additional predictor for composite endpoint. CONCLUSION: MitraClip® is a valid tool with favorable outcomes in high-risk patients. The degree of residual MR seems to impact on follow-up composite endpoint outcome. An optimal correction of MR after MitraClip placement could be advocated to optimize the benefits of the procedure and minimize the risk of adverse outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Instrumentos Cirúrgicos , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Hemodinâmica , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Análise Multivariada , Razão de Chances , Readmissão do Paciente , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Modelos de Riscos Proporcionais , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 81(7): 1224-31, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22745049

RESUMO

OBJECTIVES: The purpose of this study was to compare outcomes using standard clipping (SC) (one to two clips) or multiple clipping (MC) (more than two clips). BACKGROUND: MitraClip implantation using MC has been proposed to treat severe mitral regurgitation (MR) in high-risk patients. METHODS AND RESULTS: A tailored strategy was used implanting as many clips as required to eliminate MR. A total of 85 consecutive patients [78 ± 6 years, 48 men (56.5%) ] with MR (grade 3+ or 4+) were included. EuroSCORE was 24 ± 12 (2.5-56.3) and STS-score 12 ± 7 (1.2-31.2). SC was used in 61 (71.8%) and MC in 24 (28.2%) patients. Patients in MC group had larger mitral valve (MV) annuli (P = 0.025), MV orifice areas (MVOA) (P = 0.01), and MR degree (P = 0.005). Successful clip placement was achieved in 82 patients (96.5%). At discharge, no patient had grade 4+ MR. MR 3+ presented in 4 patients (7.0%) in the SC group and in 1 (4.5%) in the MC group (P = 0.72). There were 3 (3.5%) in-hospital deaths. Follow up (211 ± 173 days, range 4-652) echocardiography confirmed similar MVOA (P = 0.83) and MV gradients (P = 0.54) in the both groups. At linear regression there was no independent correlation between clips number and postoperative MVOA/gradient. One-year survival was 71.1% without difference between groups (P = 0.74). CONCLUSION: Although the hemodynamic and anatomical basis of MR may differ, every procedure should aim at eliminating MR. In some patients this goal can be achieved using MC with minimized risk of MV stenosis if preoperative anatomy/mechanism of MV regurgitation are adequately assessed.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Instrumentos Cirúrgicos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia , Desenho de Equipamento , Feminino , Hemodinâmica , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Modelos Lineares , Modelos Logísticos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/fisiopatologia , Análise Multivariada , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
6.
Can J Cardiol ; 29(4): 452-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22926038

RESUMO

BACKGROUND: The objective of this study was to compare outcomes of surgical repair (SR) vs MitraClip (MC) implantation for severe mitral regurgitation (MR). METHODS: A retrospective analysis of patients treated within a single institution was performed. Patients had EuroSCORE [European System for Cardiac Operative Risk Evaluation] < 20%, left ventricular ejection fraction ≥45%, and grade 3+/4+ MR. RESULTS: Fifty patients (24 [48%] MC group, 26 [52%] SR group) with EuroSCORE 7.9 ± 5.6 were included. The MC group included 24 (48%) and the SR group 26 (52%) patients. Patients in the MC group had a significantly more complex comorbid profile (P < 0.001). Successful MC placement was in 22 patients (91.7%) and SR in 26 (100%). At discharge, no patient had grade 3+/4+ MR. There were no in hospital or 30-day deaths. At follow-up (mean 526 ± 398 days), further mitral valve surgery was necessary in 1 (3.8%) patient in the SR group and in 2 (8.3%) patients in the MC group (P = 0.26). One-year freedom from composite end point (death, stroke, myocardial infarction, major bleeding, cardiac rehospitalization) was 75.5% (SR 83% vs MC 67%; P = 0.18). Degree of residual MR Degree of residual MR immediately after the procedure was equally distributed in both groups (P = 0.13) and the sole independent determinant for composite outcome (odds ratio, 16.9; P = 0.024). CONCLUSIONS: MC in nonsurgical candidates and SR in surgical patients showed similar perioperative and follow-up outcomes at an institution experienced with both techniques. Neither MC nor SR were independently related to outcome whenever similar degrees of acute correction with minimal residual MR were achieved. However, these findings should be interpreted within the selection biases and the numerical limitations of the present study.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Razão de Chances , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
7.
BMC Cardiovasc Disord ; 12: 80, 2012 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23006607

RESUMO

BACKGROUND: Nonagenarians are mostly denied from different therapeutic strategies due to high comorbidity index and risk-benefit calculation. We present the results of nonagenarians with high comorbidity index not eligible for conventional aortic valve surgery undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve system. METHODS: Our retrospective analysis include baseline parameters, procedural characteristics, morbidity, mortality as well as twelve-lead surface ECG and echocardiographic parameters which were revealed preinterventionally, at hospital discharge and at 30-day follow-up. Clinical follow-up was performed 6 months after TAVI. RESULTS: Out of 158 patients 11 nonagenarians with a mean age of 92.6 ± 1.3 years suffering from severe aortic valve stenosis and elevated comorbidity index (logistic EuroSCORE of 32.0 ± 9.5%, STS score 25.3 ± 9.7%) underwent TAVI between January 2008 and January 2011 using the third-generation percutaneous self-expanding CoreValve prosthesis. Baseline transthoracic echocardiography reported a mean aortic valve area (AVA) of 0.6 ± 0.2 cm(2) with a mean and peak pressure gradient of 60.2 ± 13.1 mmHg and 91.0 ± 27.4 mmHg, respectively. The 30-day follow up all cause and cardiovascular mortality was 27.3% and 9.1%, respectively. One major stroke (9.1%), 2 pulmonary embolisms (18.2%), 1 periprocedural (9.1%) and 1 (9.1%) spontaneous myocardial infarction occured. Life-threatening or disabling bleeding occurred in 2 cases (18.2%), and minor bleeding in 7 cases (63.6%). Mean severity of heart failure according to NYHA functional class improved from 3.2 ± 0.8 to 1.36 ± 0.5 while mean AVA increased from 0.6 ± 0.2 cm(2) to 1.8 ± 0.2 cm(2). At 6-months follow-up 8 patients (72.7%) were alive without any additional myocardial infarction, pulmonary embolism, bleeding, or stroke as compared to 30-day follow-up. CONCLUSION: Our case series demonstrate that even with elevated comorbidity index, clinical endpoints and valve-associated results are relatively favorable in nonagenarians treated with CoreValve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Morbidade , Estudos Retrospectivos
8.
EuroIntervention ; 8(5): 571-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22995083

RESUMO

AIMS: Compare mid-term outcomes after MitraClip® implantation for severe mitral regurgitation (MR) in patients categorised in different logistic EuroSCORE (LES) groups. METHODS AND RESULTS: MitraClip was implanted in 85 patients (78 ± 6 years, 48 men [56.5%]) with severe symptomatic MR. Baseline characteristics, perioperative results, mid-term survival, major adverse cerebrovascular and cardiac events (MACCE), and re-hospitalisation were compared in patients with LES <20% (n=30) and ≥ 20% (n=55). Overall LES was 24 ± 12 (range 2.5-56.3) and STS-score 12 ± 7 (range 1.2-31.2). Overall procedural success rate was 96.5% with an in-hospital mortality rate of 3.5%. Echocardiographic and clinical follow-up confirmed similar mean transmitral pressure gradient (p=0.13), MR degree (p=0.48), and NYHA Class (p=0.93). Estimated six-month survival and freedom from composite endpoint was 80.7%/77.1% in LES ≥ 20% and 90.8/86.6% in LES<20% group, respectively (p= 0.014; p=0.018). Multivariate analysis determined LES ≥ 20% (OR=8.1; 95% CI 1.002-65.186), mean transmitral gradient after intervention (OR 2.5; 95% CI 1.267-5.131) and residual MR (OR=5.1; 95% CI 1.464-17.946) as predictors for overall mortality. CONCLUSIONS: LES is a good predictor of perioperative results, and follow-up adverse outcomes after MitraClip implantation are significantly influenced by the preoperative risk profile. The presence of residual MR immediately after MitraClip therapy can exacerbate the occurrence of MACCE.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
9.
Chin Med J (Engl) ; 124(20): 3427-9, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22088549

RESUMO

Drug-eluting stents have changed the practice in interventional cardiology. With the widespread use of these stents important safety concerns regarding stent thrombosis and formation of coronary artery aneurysm have been expressed. While the majority of attention was focused on stent thrombosis, the formation of coronary aneurysm was only described in anecdotal reports. We report on a patient who suffered from very late stent thrombosis in association with coronary artery aneurysm formation secondary to drug-eluting stent but not to bare-metal stent.


Assuntos
Aneurisma Coronário/diagnóstico , Trombose Coronária/diagnóstico , Stents Farmacológicos/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Feminino , Humanos , Pessoa de Meia-Idade
10.
Med Klin (Munich) ; 104(11): 878-81, 2009 Nov 15.
Artigo em Alemão | MEDLINE | ID: mdl-19916078

RESUMO

BACKGROUND: Both, acute and chronic aortic insufficiency, can be caused by various conditions. While the acute form is often associated with an endocarditis, type A aortic dissection and trauma, one possible cause of chronic aortic insufficiency is a congenital malformation of the aortic valve. Among these malformations, the quadricuspid aortic valve is the most rare form. The diagnosis is often made by Doppler echocardiography, during cardiac surgery, or postmortem. CASE REPORT: A 44-year-old female patient presented with a 2-year history of increasing dyspnea on exertion. The physical examination revealed a diastolic heart murmur in the second right intercostal space and a blood pressure of 170/60 mmHg. Transthoracic and transesophageal Doppler echocardiography disclosed a quadricuspid aortic valve with severe aortic insufficiency. After implantation of a mechanical aortic valve, the patient was clinically well. CONCLUSION: Quadricuspid aortic valve, often associated with aortic insufficiency, is a rare condition. The diagnosis can be made by Doppler echocardiography. The special treatment should be based on objective and subjective findings. In the absence of severe aortic regurgitation or clinical signs, a medical treatment with close follow-up is justified. In case of severe aortic regurgitation or clinical signs of cardiac decompensation, surgical treatment is recommended.


Assuntos
Insuficiência da Valva Aórtica/congênito , Valva Aórtica/anormalidades , Adulto , Anticoagulantes/administração & dosagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Aortografia , Quimioterapia Combinada , Dispneia/etiologia , Ecocardiografia Transesofagiana , Feminino , Humanos , Cuidados Pós-Operatórios , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA