Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Lab Hematol ; 31(2): 199-206, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18190589

RESUMO

The platelet count has a primary role in the diagnosis and treatment of idiopathic thrombocytopenic purpura (ITP). This study analysed the accuracy of ITP patient platelet counts determined by Abbott CD-Sapphire (impedance/optical) and Bayer Advia 120 (optical) analyses, compared with a reference immunoplatelet method. Instrument platelet estimates showed broad equivalence in the higher range of observed values, but significant discrepancies against the immunoplatelet count were seen when platelet counts were <10 x 10(9)/l. CD-Sapphire mean platelet volume (MPV) results revealed increased (>12 fl) platelet volumes in eight of eight ITP patients with counts of <20 x 10(9)/l compared with 6/6 and 5/13 patients with platelet counts of 20-50 and >50 x 10(9)/l. In contrast, Bayer Advia MPV values showed no relationship with the platelet count. Increased reticulated platelets were associated with an increasing CD-Sapphire MPV (R(2) = 0.61) and a decreasing platelet count. High (>40%) reticulated platelet values were seen in 9/9 patients with immunoplatelet counts of <20 x 10(9)/l compared with 0/19 patients with platelet counts above 20 x 10(9)/l. There may be a need for caution in the interpretation of platelet counts in ITP patients obtained with conventional instrument methods, and therapeutic decisions should ideally be validated by reference immunoplatelet procedures.


Assuntos
Plaquetas/patologia , Erros de Diagnóstico , Contagem de Plaquetas/métodos , Púrpura Trombocitopênica Idiopática/diagnóstico , Doença Aguda , Adolescente , Adulto , Tamanho Celular , Criança , Pré-Escolar , Doença Crônica , Humanos , Adulto Jovem
3.
Appl Opt ; 13(2): 274-9, 1974 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20125974

RESUMO

A high speed framing camera was used to record the sequential steps of the start, development, and cessation of a highly energetic plume of matter caused by a ruby laser pulse of intensity of the order of 10(7) W/cm(2) on alumina ceramic and copper materials. The results of the experiments have established that the laser intensity and a normalized absorption coefficient are the two most important factors to be considered for any material removal process such as hole drilling. This study has provided the experimental support of a theoretical analysis on laser-induced vaporization and explosion of solid material, developed and published previously.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA