Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Am J Sports Med ; 52(3): 845-858, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37183988

RESUMO

BACKGROUND: Magnetic resonance (MR) imaging is the most common modality for assessment of the rotator cuff before and after surgery. Several classifications have been described aiming to define main tear characteristics. However, there is still confusion when it comes to the reliability of those classifications. PURPOSE: (1) To identify all MR classifications available in the literature for preoperative assessment of rotator cuff tears, (2) to summarize available data on the reliability of identified classifications, and (3) to assess the methodological quality of reliability studies. STUDY DESIGN: Systematic review; Level of evidence, 4. METHODS: This systematic review was conducted following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. All studies reporting MR assessment in patients with a superior or posterosuperior rotator cuff tear were included. After identification of the available MR criteria, reliability studies were analyzed. Descriptive statistics were used to summarize findings. Methodological quality was assessed using the Quality Appraisal of Reliability Studies checklist. RESULTS: A total of 75 studies were included in this review. Eight categories of outcomes could be identified. Of the total, 62 studies reported interobserver reliability whereas 32 reported intraobserver reliability of some of the identified criteria. Each category reflected a variety of reliability, ranging from poor to excellent agreement. MR proved to be a reliable imaging modality to detect the structural integrity of the posterosuperior cuff, especially in cases of full-thickness tear; it was also reliable in terms of tear width and length and muscle atrophy based on a tangent sign or Thomazeau classification. All other classifications did not prove acceptable reliability. Methodological quality was high for 23 articles and moderate for 14. CONCLUSION: Preoperative MR is a reliable imaging modality to identify full-thickness tears, measure tear size and morphology, and identify muscle atrophy with tangent sign or Thomazeau classification. All other outcomes and classifications did not show acceptable reliability; therefore, caution is needed when using them for preoperative evaluation of a rotator cuff tear.


Assuntos
Lacerações , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Atrofia Muscular
2.
Pacing Clin Electrophysiol ; 47(1): 106-112, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37208957

RESUMO

Embolic cerebral protection devices are not routinely used in clinical practice during electrophysiological interventions. We report a case series of patients with intracardiac thrombosis undergoing a percutaneous left atrial appendage (LAA) closure and a ventricular tachycardia (VT) catheter ablation supported by TriGuard 3 Cerebral Embolic Protection Device.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivos de Proteção Embólica , Cardiopatias , Trombose , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Apêndice Atrial/cirurgia , Trombose/cirurgia
3.
Cardiovasc Revasc Med ; 57: 53-59, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37543502

RESUMO

BACKGROUND: The magnesium Magmaris scaffold is the latest resorbable technology with low thrombogenicity, short scaffolding time, and almost complete resorption at 12 months (95 %). As compared with stable coronary artery disease (SCAD), acute coronary syndrome (ACS) is associated with increased risk of adverse clinical outcome after percutaneous coronary intervention. We analyzed the data of the Magmaris Multicenter Italian Registry to compare clinical outcomes in SCAD versus ACS patients. METHODS: We evaluated the 24-month rates of target lesion failure (TLF) and scaffold thrombosis (ST). Device implantation procedures were performed according to the manufacturer's recommendations (proper patient/lesion selection, pre-dilatation, proper scaffold sizing, and post-dilatation). Dual antiplatelet therapy was terminated after 12 months. RESULTS: Data from 207 patients (145 SCAD and 62 ACS) were collected from July 2016 to June 2018. The 2-year follow-up compliance was 92.8 % (192 patients). At 2 years, TLF rates were 7.4 % in the SCAD group and 8.8 % in the ACS group (p = 0.7); ST rates were 0 % in the SCAD group and 1.8 % in the ACS group (p = 0.1). CONCLUSION: The 2-year clinical results from the Magmaris Multicenter Italian Registry are favorable in terms of TLF and ST, indicating the safety and effectiveness of the Magmaris scaffold in both SCAD and ACS patients.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Trombose , Humanos , Implantes Absorvíveis , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Trombose/etiologia , Sistema de Registros , Itália
4.
Circulation ; 148(13): 989-999, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37624364

RESUMO

BACKGROUND: Limited information is available on the comparative efficacy and safety of different stent platforms in patients at high bleeding risk undergoing an abbreviated dual antiplatelet therapy duration after percutaneous coronary intervention (PCI). The aim of this study was to compare the safety and effectiveness of the biodegradable-polymer sirolimus-eluting stent with the durable-polymer zotarolimus-eluting stent in patients at high bleeding risk receiving 1 month of dual antiplatelet therapy after PCI. METHODS: The Bioflow-DAPT Study is an international, randomized, open-label trial conducted at 52 interventional cardiology hospitals in 18 countries from February 24, 2020, through September 20, 2021. Patients with a clinical indication to PCI because of acute or chronic coronary syndrome who fulfilled 1 or more criteria for high bleeding risk were eligible for enrollment. Patients were randomized to receive either biodegradable-polymer sirolimus-eluting stents or durable-polymer, slow-release zotarolimus-eluting stents after successful lesion preparation, followed by 1 month of dual antiplatelet therapy and thereafter single antiplatelet therapy. The primary outcome was the composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year, and was powered for noninferiority, with an absolute margin of 4.1% at 1-sided 5% alpha. RESULTS: A total of 1948 patients at high bleeding risk were randomly assigned (1:1) to receive biodegradable-polymer sirolimus-eluting stents (969 patients) or durable-polymer zotarolimus-eluting stents (979 patients). At 1 year, the primary outcome was observed in 33 of 969 patients (3.6%) in the biodegradable-polymer sirolimus-eluting stent group and in 32 of 979 patients (3.4%) in the durable-polymer zotarolimus-eluting stent group (risk difference, 0.2 percentage points; upper boundary of the 1-sided 95% CI, 1.8; upper boundary of the 1-sided 97.5% CI, 2.1; P<0.0001 for noninferiority for both tests). CONCLUSIONS: Among patients at high risk for bleeding who received 1 month of dual antiplatelet therapy after PCI, the use of biodegradable-polymer sirolimus-eluting stents was noninferior to the use of durable-polymer zotarolimus-eluting stents with regard to the composite of death from cardiac causes, myocardial infarction, or stent thrombosis. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04137510.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento , Implantes Absorvíveis , Sirolimo/efeitos adversos , Infarto do Miocárdio/tratamento farmacológico , Stents/efeitos adversos , Trombose/etiologia
5.
J Cardiovasc Transl Res ; 16(5): 1135-1143, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37264295

RESUMO

The optimal duration of dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients undergoing percutaneous coronary intervention (PCI) with implantation of the Orsiro Mission stent remains unclear. The BIOFLOW-DAPT (clinicaltrials.gov, NCT04137510) trial is a prospective, multi-center, randomized controlled study designed to assess the safety of the Orsiro Mission versus the Resolute Onyx stent in HBR patients. Patients are treated with DAPT (aspirin and a P2Y12 inhibitor) for 1 month, followed by a single antiplatelet therapy (SAPT). The primary endpoint is the composite of cardiac death, myocardial infarction, and definite or probable stent thrombosis at 1 year. With a final sample size of 1948 HBR patients, this study is powered to assess the noninferiority of the Orsiro Mission stent with respect to the primary study endpoint. The BIOFLOW-DAPT is the first randomized clinical trial investigating 1-month DAPT duration in HBR patients after implantation of the Orsiro Mission stent.Trial Registration: ClinicalTrials.gov number, NCT04137510 Study design and key features. Patient selection starts before the index PCI, when consented patients will be randomized to the Orsiro Mission or the Resolute Onyx stent with mandated 1-month DAPT. At 1 month, eligibility is reassessed and if met, patients will discontinue DAPT and continue with P2Y12 inhibitor or aspirin monotherapy. PCI, percutaneous coronary intervention; DAPT, dual antiplatelet therapy; DES, drug-eluting stent; HBR, high bleeding risk; P2Y12i, P2Y12 inhibitor; ST, stent thrombosis.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Trombose , Humanos , Inibidores da Agregação Plaquetária , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Quimioterapia Combinada , Hemorragia/induzido quimicamente , Aspirina/uso terapêutico , Stents , Trombose/prevenção & controle , Trombose/induzido quimicamente , Resultado do Tratamento
6.
J Cardiovasc Comput Tomogr ; 17(4): 277-280, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37248106

RESUMO

BACKGROUND: The ADVANTAGE study demonstrated in a cohort of stented patients a diagnostic accuracy of stress myocardial CT perfusion (CTP) significantly higher than that of coronary CT angiography (CCTA) for the detection of in-stent restenosis (ISR) or CAD progression vs. quantitative coronary angiography (QCA). This is a pre-defined subanalysis of the ADVANTAGE aimed at assessing the difference in terms of diagnostic accuracy vs. QCA of a subendocardial vs. a transmural perfusion defect using static stress CTP. METHODS: We enrolled consecutive patients who previously underwent coronary stenting and were referred for QCA. All patients underwent stress CTP and rest CTP â€‹+ â€‹CCTA. The diagnostic accuracy of CCTA and CTP were evaluated in territory-based and patient-based analyses. We compared the diagnostic accuracy of "subendocardial" perfusion defect, defined as hypo-enhancement encompassing >25% but <50% of the transmural myocardial thickness within a specific coronary territory vs. "transmural" perfusion defect, defined as hypo-enhancement encompassing >50% of the transmural thickness. RESULTS: In 150 patients (132 men, mean age 65.1 â€‹± â€‹9.1 years), the diagnostic accuracy of subendocardial vs. transmural perfusion defect in a vessel-based analysis was 93.5% vs. 87.7%, respectively (p â€‹< â€‹0.0001). The sensitivity and specificity of subendocardial vs. transmural defect were 87.9% vs. 46.9% (p â€‹< â€‹0.001) and 94.9% vs. 97.9% (p â€‹= â€‹0.004), respectively. In a patient-based analysis, the diagnostic accuracy of the subendocardial vs. transmural approach was 86.6% vs. 68% (p â€‹< â€‹0.0001). CONCLUSIONS: This study shows that detection of a subendocardial perfusion defect as compared to a transmural defect is significantly more accurate to identify coronary territories with ISR or CAD progression.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Estenose Coronária , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Valor Preditivo dos Testes , Angiografia Coronária , Angiografia por Tomografia Computadorizada , Constrição Patológica , Intervenção Coronária Percutânea/efeitos adversos , Perfusão
7.
Cardiovasc Revasc Med ; 54: 57-60, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37085354

RESUMO

BACKGROUND: Transradial approach for carotid artery stenting (TRCAS) is an established technique in specific anatomies potentially associated with high periprocedural event rate from femoral catheterization. The engagement of left common carotid artery originating from the aortic arch is the most challenging scenario requiring specific catheters and techniques. METHODS: Among 542 consecutive TRCAS 66 had left, non-bovine carotid stenosis as the target vessel. We retrospectively compared the feasibility, safety, efficacy, fluoroscopy time and radiation exposure of two different techniques, the standard (ST) and the 'trawl-fishing' (TFT), to engage the LCCA with the 5F, 125 cm-long Simmons-2 catheter. RESULTS: The ST was initially used in 20 patients with a technical success of 85 % (17/20). In the following 46 patients, the TFT was successfully tested first as bailout after ST failure in 12 cases and as first option in the remaining 34 patients. Full technical success was obtained in all patients at the first attempt. No MACCEs or vascular complications occurred in all patients. Fluoroscopy time and radiation exposure were significantly lower with the TFT vs. ST (p < 0.001). CONCLUSIONS: TFT represents a definite improvement in the technique of LCCA engagement during TRCAS.


Assuntos
Estenose das Carótidas , Humanos , Aorta Torácica , Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Catéteres , Artéria Radial/diagnóstico por imagem , Estudos Retrospectivos , Stents , Resultado do Tratamento
8.
EuroIntervention ; 19(2): e167-e175, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-36636768

RESUMO

BACKGROUND: The novel sirolimus-eluting resorbable scaffold DREAMS 3G was designed as a third-generation development of its predecessor, the Magmaris scaffold. AIMS: This preclinical study aimed to examine the qualitative and temporal course of the degradation of the DREAMS 3G relative to the Magmaris scaffold. METHODS: Forty-nine DREAMS 3G and 24 Magmaris scaffolds were implanted into 48 mini swine for degradation kinetics analysis. Another DREAMS 3G was implanted into one mini swine for crystallinity analysis of the degradation end product after 730 days. Degradation kinetics were determined at 28, 90, 120, 180, and 365 days. RESULTS: Discontinuity density in DREAMS 3G was significantly lower than that in Magmaris scaffolds for the follow-up timepoints of 90 and 120 days. Planimetric analysis indicated 99.6% backbone degradation for DREAMS 3G at 12 months. Compared to the Magmaris scaffold, individual strut degradation in DREAMS 3G showed less variability and the remaining backbone core was more homogeneous. The degradation end product of DREAMS 3G manifested as calcium phosphate with a minor share of aluminium phosphate. CONCLUSIONS: DREAMS 3G showed almost complete degradation after one year, with amorphous calcium and aluminium phosphate as the end products of degradation. Despite its thinner struts, scaffold discontinuity was significantly lower in the DREAMS 3G than in the Magmaris scaffold, likely providing a longer scaffolding time.


Assuntos
Implantes Absorvíveis , Intervenção Coronária Percutânea , Animais , Suínos , Magnésio , Cinética , Fosfatos , Desenho de Prótese , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 143(6): 3241-3250, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36344784

RESUMO

INTRODUCTION: For several years, many arthrometers have been developed to assess anterior knee laxity. The aim of our study was to evaluate the validity of a new practical and handy testing device with the hypothesis that the new arthrometer had good validity in terms of reliability and accuracy. METHODS: Lachman test was performed on five fresh frozen cadaveric knees by five examiners. Anterior tibial translation (ATT) was measured with a new arthrometer (BLU-DAT) and on lateral stress radiographs. Data on ATT were obtained under 7 kg (69 N), 9 kg (88 N), and maximum manual traction (MMT). Tests were performed on the same specimens before and after arthroscopic ACL excision. Inter-rater reliability of the BLU-DAT measures was assessed with the intraclass correlation coefficient (ICC) for single and average measurements. The Bland-Altman method was used to estimate agreement between the BLU-DAT and stress radiographs. RESULTS: ICC values for single measurements were 0.62, 0.54 and 0.58 for 7-kg, 9-kg and MMT assessment, respectively. Overall reliability was good (ICC = 0.63). ICC values for average measurements were 0.89, 0.85 and 0.88 for 7-kg, 9-kg and MMT assessment, respectively. Overall reliability was very good (ICC = 0.90) SEM ranged from 1.4 mm to 1.6 mm for single measurements and was below 1 mm at each testing condition for average measurements. Analysis of agreement between BLU-DAT and radiographic measurements showed a mean difference equal to 0.83 mm ± 2.1 mm (95% CI: 0.55-1.11). Upper LOA was equal to 4.9 mm (95% CI: 5.39-4.41). Lower LOA was equal to - 3.2 mm (95% CI: - 2.71 to - 3.69). CONCLUSION: Measurement of anterior knee laxity with the BLU-DAT testing device has a good to very good inter-rater reliability and good agreement with a gold standard such as stress radiographs. Cadaveric Diagnostic Study, Level of Evidence IV.


Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Humanos , Reprodutibilidade dos Testes , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Joelho/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Cadáver
10.
EuroIntervention ; 18(13): e1090-e1098, 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36147027

RESUMO

BACKGROUND: Cardiac stress tests remain the cornerstone for evaluating patients suspected of having obstructive coronary artery disease (CAD). Coronary microvascular dysfunction (CMD) can lead to abnormal non-invasive tests. AIMS: We sought to assess the diagnostic performance of exercise stress tests with indexes of epicardial and microvascular resistance as reference. METHODS: This was a prospective, single-arm, multicentre study of patients with an intermediate pretest probability of CAD and positive exercise stress tests who were referred for invasive angiography. Patients underwent an invasive diagnostic procedure (IDP) with measurement of fractional flow reserve (FFR) and index of microvascular resistance (IMR) in at least one coronary vessel. Obstructive CAD was defined as diameter stenosis (DS) >50% by quantitative coronary angiography (QCA). The objective was to determine the false discovery rate (FDR) of cardiac exercise stress tests with both FFR and IMR as references. RESULTS: One hundred and seven patients (137 vessels) were studied. The mean age was 62.1±8.7, and 27.1% were female. The mean diameter stenosis was 37.2±27.5%, FFR was 0.84±0.10, coronary flow reserve was 2.74±2.07, and IMR 20.3±11.9. Obstructive CAD was present in 39.3%, whereas CMD was detected in 20.6%. The FDR was 60.7% and 62.6% with QCA and FFR as references (p-value=0.803). The combination of FFR and IMR as clinical reference reduced the FDR by 25% compared to QCA (45.8% vs 60.7%; p-value=0.006). CONCLUSIONS: In patients with evidence of ischaemia, an invasive functional assessment accounting for the epicardial and microvascular compartments led to an improvement in the diagnostic performance of exercise tests, driven by a significant FDR reduction.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Masculino , Doença da Artéria Coronariana/diagnóstico , Teste de Esforço , Estenose Coronária/diagnóstico , Constrição Patológica , Estudos Prospectivos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Índice de Gravidade de Doença
11.
Minerva Cardiol Angiol ; 70(6): 765-777, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36519647

RESUMO

BACKGROUND: The aim of this study was to evaluate the feasibility, safety and efficacy of transradial/brachial (TR/TB) carotid artery stenting (CAS) with proximal cerebral protection (PCP) as a first line of treatment of carotid artery stenosis. METHODS: Among 556 patients with significant (>50% if symptomatic or >70% if asymptomatic by Doppler US) unilateral, lipid-rich carotid artery stenosis undergoing TR/TB CAS, 137 (24.5%) deemed at high-risk for periprocedural cerebral embolization were scheduled for PCP with Mo.MA Ultra or Mo.MA mono-balloon. In patients with very complex anatomy the standard technique was modified loading the Mo.MA catheter without mandrel on two-wire system (so called 'No MAndrel 2 wire' technique, No.MA2) to increase support and deliverability. Device, technical and procedural successes both acute and at follow-up were the main outcomes. RESULTS: Mean patients' age was 74±7 years (93% male), 15% were symptomatic and 59.6% owned 'high-surgical-risk' features. Stenosis degree was 85±7% with soft composition in all (by CT-angiography). TR and TB approach were selected in 92 (67%) and 45 (33%) patients, respectively. Target carotid axes were right, left bovine and left non bovine in 55%, 38% and 7% of patients. Procedures were successfully completed in all patients (intention-to-treat basis) with the standard Mo.MA Ultra system in 129 patients and the Mo.MA mono-balloon in 8 patients. No.MA2 technique was succesfully used in 16 patients as 'bailout' and in 27 patients as 'first line'). Device and technical success was 97% (133/137 patients) due to crossover to femoral access in 3 cases, and Mo.MA too short to engage the ECA in 1 patient. The procedural success was 96.7% (131/137, two minor strokes). Procedural time and fluoroscopy time were increased with No.MA2 technique. One major vascular complication occurred, in the TB group, while chronic radial occlusion was detected by Doppler ultrasound in 7/92 patients (7.1%) at 372±163 days of follow-up. The event-free survival was 91% and the stroke rate was 0%. CONCLUSIONS: TR/TB CAS with proximal protection is a feasible, safe and effective strategy and may be considered a first line strategy in all comer patients.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Estenose das Carótidas/complicações , Stents/efeitos adversos , Artéria Radial , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Artérias Carótidas
12.
Front Cardiovasc Med ; 9: 922696, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36407470

RESUMO

Background: Conduction disorders (CD) are the most common complications after Transcatheter Aortic Valve Implantation (TAVI). The last generation of Edwards balloon expandable valves, the SAPIEN 3 Ultra (S3U), is provided with an external sealing skirt that aims to further reduce paravalvular leakage (PVL) compared to SAPIEN 3 (S3) and could potentially lead to higher CD rate. We sought to investigate the rate of new-onset CD in patients undergoing TAVI with the S3 or S3U valve. Methods: We included 582 consecutive patients undergoing TAVI in a single high-volume Center. Patients with previously implanted pacemaker and Valve in valve procedures were excluded. CD rate was evaluated early after implantation and at discharge. Results: No significant difference in the overall CD rate was found between S3 and S3U patients both immediately after the procedure (S3 45.5% vs. S3U 41.8%, p = 0.575) and at discharge (S3 30.4% vs. S3U 35.6%, p = 0.348) with low rate of permanent pacemaker implantation (S3 6.3% vs. S3U 5.5%, p = 0.749). No significant differences were found also in patients with pre-existing atrial fibrillation (S3 8.2% vs. S3U 5%, p = 0.648). A significantly lower rate of PVL was found with S3U compared to S3 (S3 42% vs. S3U 26%, p = 0.007). According to the manufacturer's guidelines we confirmed that S3U were implanted in a significantly higher position compared to S3 (S3 4.89 ± 1.57 mm vs. S3U 4.47 ± 1.36 mm, p = 0.001). Conclusion: No significant difference in the rate of CD, including the need for PPM implantation, was found in patients undergoing TAVI with the S3 compared to S3U. Moreover, S3U significantly reduced the PVL rate.

13.
JACC Case Rep ; 4(8): 486-490, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35493795

RESUMO

Left atrial appendage (LAA) closure may be complicated by occluder embolization. Percutaneous retrieval is preferred for devices embolized to large vessels. In this report, the successful percutaneous retrieval of an LAA occluder embolized to the abdominal aorta was followed by several complications, culminating in iatrogenic aortic rupture requiring endovascular repair. (Level of Difficulty: Advanced.).

14.
Knee Surg Sports Traumatol Arthrosc ; 30(11): 3835-3841, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35435470

RESUMO

PURPOSE: To compare the clinical outcome of arthroscopic capsulolabral repair for traumatic anterior shoulder instability with PEEK knotless and knotted biodegradable suture anchors. METHODS: Arthroscopic stabilization was performed in 78 patients with recurrent traumatic anterior shoulder instability. They were divided into 2 groups of 39 patients each, according to suture anchors used: knotless PEEK anchors in group 1, and biodegradable anchors in group 2. Exclusion criteria were: instability without dislocation, posterior or multidirectional instability, glenoid bone loss > 20%, off-track lesions, concomitant rotator cuff tears and previous surgery. The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) self-administered questionnaire. Secondary outcomes were: Work-DASH, Sport-DASH, Rowe score, recurrent instability and subsequent surgery. The following independent variables were considered: age, gender, dominance, generalized ligamentous hyperlaxity, duration of symptoms, age at first dislocation, number of dislocations, type of work, type of sport, sports activity level, capsule-labral injury pattern, SLAP lesion and number of anchors. Differences between groups for numerical variables were analyzed by use of the Student's t-test or Mann-Whitney U-test. Fisher's exact test was used for analysis of categorical variables. Significance was set at p < 0.05. RESULTS: Seven patients (9%) were lost at follow-up, 5 from group 1 and 2 from group 2. Follow-up ranged from 36 to 60 months (median: 44; IQR: 13). Comparison between groups did not show significant differences for each independent variable considered. No differences could be found either for DASH (n.s.) or Rowe (p = n.s.) scores between the two groups. Overall recurrence rate was 7%. Three re-dislocations were reported in group 1 and two in group 2 (n.s.). Only one patient in each group underwent re-operation. CONCLUSIONS: The study showed no significant differences in clinical outcomes after arthroscopic treatment of traumatic anterior shoulder instability using PEEK knotless or biodegradable knotted anchors at mid-term follow-up. LEVEL OF EVIDENCE: I.


Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Artroscopia , Benzofenonas , Humanos , Luxações Articulares/complicações , Instabilidade Articular/complicações , Instabilidade Articular/cirurgia , Polímeros , Estudos Prospectivos , Recidiva , Ombro , Luxação do Ombro/complicações , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Âncoras de Sutura , Resultado do Tratamento
15.
Cardiovasc Revasc Med ; 41: 69-75, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35256294

RESUMO

BACKGROUND: Magnesium Reabsorbable Scaffold (MRS), is the newest reabsorbable technology with low thrombogenicity, short scaffolding time and almost complete resorption at 12-months (95%). Preliminary 12-months data in selected patients has shown that safety and efficacy are comparable with second generation Drug Eluting Stent (DES). Magmaris Multicenter registry showed 1-and 2-years clinical outcome on the first patients suitable for MRS enrolled in 4 Italian centers. METHODS: We evaluated 12- and 24-months clinical results in "real world" experience with Magnesium Reabosrbable Scaffold in terms of Target Lesion Failure (TLF) and scaffold thrombosis (ST). TLF is the primary endpoint and was defined as composite of cardiac mortality, target vessel myocardial infarction (MI), and ischemia-driven target lesion revascularization (ID-TLR). 4P's strategy (Patient/lesion selection, Pre-dilatation, Proper scaffold sizing and Post-dilatation) was strongly recommended. Dual Antiplatelet Therapy (DAPT) has been recommended for 12 months. RESULTS: Data from 207 patients, including initial experience, have been collected. Patients were 83% male, 20% diabetic and Acute Coronary Syndrome (ACS) in 23%. Lesion type were A-B1 in 54% and B2C in 46%. 4P's strategy was respected in 94%. Procedural success was 98% (2% peri-procedural MI). Compliance at 12-months follow up was 97.6%, TLF rate was 5.4% (including 1 case of myocardial infarction with late scaffold thrombosis (ST), all patients were successfully treated with in-scaffold segment DES implantation). At 24-months compliance was 92.8% (192 patients) and TLF was 7.4%. In the period between 13 and 24 months only 4 patients had TLF (including 1 case of myocardial infarction, all patients were successfully treated with in-scaffold segment DES implantation). None of the patients died for a cardiac reason. CONCLUSION: Our 2-years results confirm safety and efficacy showed at 12-months, reinforcing long-term performance with only 2% rate of TLF increase and no ST after 1 year.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Magnésio , Masculino , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/terapia , Desenho de Prótese , Sistema de Registros , Trombose/etiologia , Resultado do Tratamento
16.
Front Cardiovasc Med ; 9: 829117, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35265684

RESUMO

Objectives: This study aims to describe the outcome of intravascular lithotripsy (IVL) when used with different indications and to assess the short- and long-term outcomes of IVL-facilitated percutaneous coronary intervention (PCI). Background: Intravascular lithotripsy can improve the results of PCI of calcified coronary lesions with a low rate of periprocedural complications. Methods: A total of 105 consecutive patients with 110 calcified lesions underwent IVL. A total of 87 de novo lesions were treated by IVL with the following indications: 25 before attempting other balloon-based devices (primary IVL), 51 after the failure of non-compliant balloon dilatation (secondary IVL), and 11 after stent implantation because of stent under expansion (bailout IVL). In 23 lesions, IVL was used for the treatment of in-stent restenosis (ISR). Effectiveness (angiographic success) and safety [major adverse cardiovascular events (MACEs) and IVL-related procedural complications] endpoints were assessed. Results: Angiographic success was achieved in 84.6% of lesions. Early MACEs were periprocedural MI only, ranging from 6.7 to 20% depending on MI definition. The flow-limiting dissections rate was 2.7%. A total of five (4.5%) IVL balloons ruptured during treatment with subsequent vessel perforation in 1 case. MACEs at 12 months were 13.3%, with TLR occurring in 8 lesions (12% primary IVL, 0% secondary IVL, 0% bailout IVL, and 21.7% IVL for ISR, p = 0.002). Conclusion: Treatment of calcified coronary lesions with IVL in a "real-world" setting can be performed with high success, low rate of procedural complications, and an acceptable MACEs rate. Target lesion failure may be more frequent when IVL is performed for the treatment of ISR due to calcium-mediated stent under expansion.

17.
J Chromatogr A ; 1664: 462796, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-34999302

RESUMO

Phosphonium-based ionic liquids (ILs) have proven to be successful stationary phases (SPs) for gas chromatography (GC) in several fields of application because of their unique selectivity and good chromatographic properties. This study focuses on the use of two ILs as GC SPs that are based on the phosphonium derivatives trihexyl(tetradecyl)phosphonium chloride ([P66614+] [Cl-]), and trihexyl(tetradecyl)phosphonium bis[(trifluoromethyl)sulfonyl]imide ([P66614+][NTf2-]), which have previously been shown to be complementary in terms of chromatographic selectivity and retention. Their application in routine analysis has been limited by their lower maximum allowable operating temperatures (MAOT) (200 °C for the [P66614+][Cl-] IL and 180 °C for [P66614+][NTf2-]), which restricts their use to samples that consist of analytes with relatively high volatility. A previous study carried out in the Authors' laboratory focused on extending the use of the [P66614+][Cl-] IL SP to the analysis of samples with analytes of medium-to-low volatility by optimizing column characteristics and operative conditions. This study addresses the immobilization of both the [P66614+][Cl-] and [P66614+][NTf2-] ILs to the inner wall of fused silica columns to increase their MAOT under soft and hard reaction conditions. The resulting MAOT depended on more or less drastic immobilization conditions, and reached 220 °C for soft immobilization (So-Im) and 240 °C for hard immobilization (Ha-Im) in the [P66614+][Cl-] IL columns, and 200 °C for So-Im and 220° for Ha-Im in columns coated with the [P66614+] [NTf2-] IL. The influence of immobilization on the separation power and performance of all the columns has been evaluated using i) the Grob test, ii) a model mixture of 41 compounds of different polarity, structure, and with different organic functional groups representative of the flavor and fragrance field, iii) a standard mixture of 37 fatty acid methyl esters, iv) the peppermint essential oil, v) two mixtures of sesquiterpenic alcohols (farnesols and santalols), and vi) a standard mixture of 16 pesticides. These test samples were also used to demonstrate the complementarity of the two phosphonium-based IL SPs in terms of selectivity and retention.


Assuntos
Produtos Biológicos , Líquidos Iônicos , Perfumes , Cromatografia Gasosa , Odorantes/análise , Perfumes/análise
18.
Cardiovasc Revasc Med ; 39: 106-113, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34629285

RESUMO

Bioresorbable scaffolds provide transient vessel support without the long-term limitations of permanent metallic drug-eluting stents. The sirolimus-eluting resorbable magnesium scaffold Magmaris is the only CE-marked metallic bioresorbable scaffold and provides short-term lumen support before being completely bioresorbed. To date, clinical trial results have demonstrated low adverse event rates in patients with simple coronary lesions. Seven European centers with large experience in Magmaris implantation, combined efforts in an informal collaboration to evaluate and appraise clinical data currently available regarding the performance of Magmaris in patients presenting with acute coronary syndromes, and to supply user-advice on patient selection and optimal implantation practice.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Implantes Absorvíveis , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/etiologia , Humanos , Magnésio , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Resultado do Tratamento
19.
Cardiovasc Revasc Med ; 34: 11-16, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33674219

RESUMO

Bioresorbable scaffolds have emerged as a potential breakthrough for the treatment of coronary artery lesions. The need for drug release and plaque scaffolding is temporary, and leaving a permanent stent once the process of plaque recoil and vessel healing has ended might be superfluous or even deleterious exposing the patient to the risk of very late thrombosis, eliminating vessel reactivity, impairing non-invasive imaging and precluding possible future surgical revascularization. This long-term potential limitation of permanent bare metal stents might be overcome by using a resorbable scaffold. The metallic and antithrombotic properties make the resorbable magnesium scaffold an appealing technology for the treatment of coronary artery lesions. Notwithstanding this, its mechanical properties substantially differ from those of conventional bare metal stents, and previous experience using polymer-based scaffolds has shown that a standardized implantation technique and optimal patient and lesion selection are key factors for a successful implantation. A panel of expert cardiologists gathered to find a consensus on the best practices for Magmaris implantation in a selected patient population and to discuss the rationale for new potential future indications.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Magnésio , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Resultado do Tratamento
20.
Minerva Cardiol Angiol ; 70(6): 738-750, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36700669

RESUMO

Carotid artery stenting (CAS) is an established technique to treat carotid artery stenosis. Favorable results have been reported in different subsets of patients in both acute and long-term settings. Among the CAS periprocedural variables the type of cerebral protection - distal filter and proximal protection - play a pivot role to reduce cerebral embolization. Accumulating evidence is in favor of better performance of proximal protection vs. distal filters. However, the rate of worldwide penetration of this devise is low. Potential reasons include a lengthy list of technical issues that may account for the reluctance of filter-oriented operators to change systems. This paper shows how to identify, treat, and overcome these technical obstacles.


Assuntos
Estenose das Carótidas , Humanos , Estenose das Carótidas/cirurgia , Resultado do Tratamento , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA