Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 34(6): 951-958, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34617663

RESUMO

OBJECTIVE: The aims of this study were to evaluate whether the use of a dentifrice containing 5% potassium nitrate (KNO3 ) prior to and during in-office dental bleaching reduces bleaching-induced tooth sensitivity and affects bleaching efficiency. MATERIALS AND METHODS: Thirty-eight individuals were randomly distributed into two groups (n = 19). The experimental group performed toothbrushing using a dentifrice containing 5% KNO3 , one week before treatment and before the first and second bleaching sessions. In the control group, a placebo dentifrice without KNO3 was applied as described for the first group. Tooth sensitivity was recorded on visual analog scales (VAS) and numeric rating scales (NRS) immediately and up to 48 h after bleaching sessions. Color change at different time intervals, was evaluated with shade guide units (∆SGU) and a digital spectrophotometer (∆E CIELab 1976 and CIEDE2000) at baseline and 7, 15, and 30 days post-bleaching. Mann-Whitney test and t-test were used to evaluate TS intensity for NRS and VAS scales, respectively, and T-test was used for color difference evaluation. RESULTS: No significant difference in tooth sensitivity's absolute risk and intensity were observed between tested groups in any evaluated treatment time for NRS (p = 0.91) or VAS scales (p = 0.48). T-test showed no significant difference in both ∆E and ∆SGU tooth color among the experimental and control groups during the different evaluation times (p = 0.27). CONCLUSION: The use of a dentifrice containing 5% KNO3 does not prevent post-operatory tooth sensitivity but allows the same whitening efficiency as a regular dentifrice. CLINICAL SIGNIFICANCE: The use of a dentifrice-containing KNO3 did not prevent bleaching-induced tooth sensitivity when high-concentrated hydrogen peroxide was used for in-office bleaching.


Assuntos
Dentifrícios , Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Dentifrícios/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Sensibilidade da Dentina/prevenção & controle , Humanos , Peróxido de Hidrogênio/efeitos adversos , Nitratos , Compostos de Potássio/uso terapêutico , Clareamento Dental/efeitos adversos , Clareadores Dentários/efeitos adversos , Resultado do Tratamento
2.
J Appl Oral Sci ; 29: e20200865, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33886943

RESUMO

Denture stomatitis is the most frequent oral lesion in removable prosthesis wearers, with high recurrence rates and a complex treatment. OBJECTIVE: This study describes a protocol to obtain and to contaminate a palatal device with Candida albicans biofilm that could be used for an animal model of denture stomatitis. METHODOLOGY: Acrylic resin devices (N=41) were obtained from impressions of the palates of Wistar rats with individual trays and polyether. The efficacy of microwave irradiation (MW), ultraviolet light (UV), or ultrasonic bath (US) was assessed by colony viability and spectrophotometric analyses (n=5) in order to select the most appropriate method for sterilizing the devices. Then, different devices (n=5) were contaminated with C. albicans and evaluated by CFU/mL determination, scanning electron microscopy, and laser confocal microscopy. Device stabilization was assessed with either autopolymerizing acrylic resins or a self-adhesive resin cement (n=2). The spectrophotometric data were analyzed by one-way ANOVA followed by the Tukey's HSD post-hoc test (α=0.05). RESULTS: MW was the only method capable of sterilizing the devices, and the contamination protocol developed a mature and viable C. albicans biofilm (~1.2 x 106 CFU/mL). The self-adhesive resin cement was the best stabilization material. CONCLUSIONS: This acrylic resin palatal device was designed to be similar to the clinical situation of contaminated prostheses, with easy manufacturing and handling, effective stabilization, and satisfactory contamination. Thus, the acrylic device can be a valuable tool in the development of denture stomatitis in rats.


Assuntos
Candida albicans , Estomatite sob Prótese , Resinas Acrílicas , Animais , Biofilmes , Bases de Dentadura , Palato , Ratos , Ratos Wistar
3.
J. appl. oral sci ; 29: e20200865, 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1286916

RESUMO

Abstract Denture stomatitis is the most frequent oral lesion in removable prosthesis wearers, with high recurrence rates and a complex treatment. Objective This study describes a protocol to obtain and to contaminate a palatal device with Candida albicans biofilm that could be used for an animal model of denture stomatitis. Methodology Acrylic resin devices (N=41) were obtained from impressions of the palates of Wistar rats with individual trays and polyether. The efficacy of microwave irradiation (MW), ultraviolet light (UV), or ultrasonic bath (US) was assessed by colony viability and spectrophotometric analyses (n=5) in order to select the most appropriate method for sterilizing the devices. Then, different devices (n=5) were contaminated with C. albicans and evaluated by CFU/mL determination, scanning electron microscopy, and laser confocal microscopy. Device stabilization was assessed with either autopolymerizing acrylic resins or a self-adhesive resin cement (n=2). The spectrophotometric data were analyzed by one-way ANOVA followed by the Tukey's HSD post-hoc test (α=0.05). Results MW was the only method capable of sterilizing the devices, and the contamination protocol developed a mature and viable C. albicans biofilm (~1.2 x 106 CFU/mL). The self-adhesive resin cement was the best stabilization material. Conclusions This acrylic resin palatal device was designed to be similar to the clinical situation of contaminated prostheses, with easy manufacturing and handling, effective stabilization, and satisfactory contamination. Thus, the acrylic device can be a valuable tool in the development of denture stomatitis in rats.


Assuntos
Animais , Ratos , Estomatite sob Prótese , Candida albicans , Palato , Resinas Acrílicas , Ratos Wistar , Biofilmes , Bases de Dentadura
4.
Eur J Dent ; 6(3): 248-54, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22904652

RESUMO

OBJECTIVE: To evaluate the effects of etch-and-rinse and self-etching adhesive systems on Vickers hardness (VHN) uniformity of dual-cured resin cements after fiber post cementation. METHODS: FIFTY GLASS FIBER POSTS WERE CEMENTED INTO BOVINE ROOTS USING THE FOLLOWING CEMENTING SYSTEMS: Prime&Bond 2.1 Dual Cure and Enforce with light-activation (PBDC-LCEN); Prime&Bond 2.1 and Enforce with light-activation (PB-CLEN); Prime&Bond 2.1 Dual Cure and Enforce without light exposure (PBDC-SCEN); ED Primer and Panavia 21 (ED-SCPN); and Clearfil SE Bond and Panavia 21 (CF-SCPN). The roots were stored in distilled water for 72 h and transversely sectioned into thirds (coronal, medium, and apical). The VHN values of the resin cement layers were measured close to the post and to the dentin wall on the transversely sectioned flat surfaces. The results were analyzed by three-way repeated measures analysis of variance (ANOVA) and Tukey's post-hoc test (pre-set alpha of 5%). RESULTS: Most resin cements presented higher VHN values near the post than near the dentin wall. The ED-SCPN group showed the highest VHN values regardless of the root third, while the self-cured group PBDC-SCEN exhibited the lowest values. The resin cements from the light-activated groups PBDC-LCEN and PB-LCEN showed lower VHN values at the apical third than at the coronal third. The VHN values were not influenced by the root third in self-cured groups PBDC-SCEN, ED-SCPN, and ED-SCPN. CONCLUSION: Depending on the product, bonding agents might promote changes in hardness uniformity of resin cements after post cementation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA