Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656032

RESUMO

We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Facoemulsificação , Retalhos Cirúrgicos , Acuidade Visual , Humanos , Facoemulsificação/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Masculino , Diplopia/etiologia , Resultado do Tratamento , Topografia da Córnea , Catarata , Pessoa de Meia-Idade
2.
Arq. bras. oftalmol ; 87(4): e2023, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557099

RESUMO

ABSTRACT We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.

3.
Rev. bras. oftalmol ; 83: e0043, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1569743

RESUMO

ABSTRACT Objective To evaluate intraocular lens power calculation and postoperative refractive errors in patients with high myopia undergoing cataract surgery, comparing predicted target refraction and actual postoperative refraction measured 30 days after surgery with SRK/T formula. Methods This retrospective analysis comprised 39 eyes of 31 patients undergoing cataract surgery through phacoemulsification with in-the-bag IOL implantation. Axial length was measured by partial coherence interferometry or immersion ultrasound biometry, with measurements greater than 26 mm and preoperative myopia greater than -6.0 D Manifest refraction was performed at the 1-month postoperative visit, and the spherical equivalent was analyzed. Results After analysis of 39 eyes of 31 patients undergoing cataract surgery with a mean axial length of 30.4 (standard deviation of 2.2) mm, the mean preoperative refractive spherical equivalent was -15.6 (standard deviation of 7.6) D, ranging from -24.0 to -13.4 D. At 30 days postoperatively, the mean spherical equivalent was -0.35 (standard deviation of 1.1) D, ranging from -2.4 to 2.50 D. Conclusion We encountered a correlation between the absolute refractive error and the dioptric power of the intraocular lens. Against expectations, in our study, ultrasound biometry yielded better results than the optical biometer device, probably due to the small number of patients undergoing optical biometry, suggesting that well-performed immersion biometry can still produce satisfactory results.


RESUMO Objetivo Avaliar os cálculos de potência da lente intraocular e os erros refrativos pós-operatórios em pacientes com alta miopia submetidos à cirurgia de catarata, comparando a refração-alvo prevista e a refração pós-operatória real medida 30 dias após a cirurgia com a fórmula SRK/T. Métodos Esta análise retrospectiva incluiu 39 olhos de 31 pacientes com cirurgia de catarata de facoemulsificação não complicada com implantação de lente intraocular na bolsa. Os comprimentos axiais foram medidos por biometria de coerência óptica ou ultrassônica (imersão), com medidas de axial length (AL) maiores que 26 mm em pacientes com miopia maior que -6.0 D. A refração manifesta foi realizada na consulta pós-operatória de 1 mês, e o equivalente esférico foi analisado. Resultados Após análise de 39 olhos de 31 pacientes submetidos à cirurgia de catarata com AL médio de 30,4 (desvio-padrão de 2,2) mm, o equivalente esférico refrativo médio pré-operatório foi de -15,6 (desvio-padrão de 7,6) D, variando de -24,0 a -13,4 D. Aos 30 dias de pós-operatório, o equivalente esférico médio foi de -0,35 (desvio-padrão de 1,1) D, variando de -2,4 a 2,50 D. Conclusão Encontramos uma correlação entre o erro refrativo absoluto e o poder dióptrico da lente intraocular. Contrariando as expectativas, em nosso estudo, a biometria ultrassônica apresentou melhores resultados que o biômetro óptico, provavelmente devido ao pequeno número de pacientes submetidos à biometria óptica, sugerindo que a biometria de imersão bem executada ainda pode produzir resultados satisfatórios.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA