Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Indian Heart J ; 75(4): 279-284, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36972762

RESUMO

OBJECTIVES: To assess the long-term (3 years) safety and efficacy of Tetrilimus everolimus-eluting stent (EES) and subgroup analysis of outcomes of ultra-long (44/48 mm) Tetrilimus EES implantation in patients with long coronary lesions. MATERIAL AND METHODS: In this observational, single-centre, single-arm, investigator-initiated registry, 558 patients who underwent implantation of Tetrilimus EES for the treatment of coronary artery disease were retrospectively included. The primary endpoint was occurrence of any major adverse cardiac event (MACE) at 12 months follow-up (composite of cardiac death, myocardial infarction [MI], and target lesion revascularization [TLR]) and we hereby report 3 years follow-up data. Stent thrombosis was assessed as a safety endpoint. A subgroup analysis of patients with long coronary lesions is also reported. RESULTS: A total of 558 patients (57.0 ± 10.2 years) received 766 Tetrilimus EES (1.3 ± 0.5 stents/patient) to treat 695 coronary lesions. In subgroup analysis of 143 patients implanted with ultra-long EES, 155 lesions were intervened successfully with only one Tetrilimus EES (44/48 mm) implanted per lesion. At 3 years, event rates of 9.1% MACE with predominance of MI (4.4%), followed by 2.9% TLR and 1.7% cardiac death, and only 1.0% stent thrombosis were reported in overall population, while in a subgroup of patients implanted with ultra-long EES, 10.4% MACE and 1.5% stent thrombosis were reported. CONCLUSIONS: Three years clinical outcomes showed favourable long-term safety and excellent performance of Tetrilimus EES in high-risk patients and complex coronary lesions in routine clinical practice, including a subgroup of patients with long coronary lesions, with acceptable primary and safety endpoints.


Assuntos
Aterosclerose , Trombose Coronária , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Everolimo/farmacologia , Trombose Coronária/etiologia , Estudos Retrospectivos , Seguimentos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Stents , Aterosclerose/etiologia , Desenho de Prótese , Morte , Resultado do Tratamento
2.
Minerva Med ; 111(4): 315-323, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33032393

RESUMO

BACKGROUND: The registry investigated clinical outcomes after 12 months of implantation of ultra-thin strut (60 µm) biodegradable polymer-coated Tetrilimus everolimus-eluting stents (EES; Sahajanand Medical Technologies Pvt. Ltd., Surat, India) in patients with atherosclerotic coronary lesions. Additionally, sub-group analysis was performed to evaluate outcomes of ultra-long (44/48 mm) Tetrilimus EES in patients with long lesions. METHODS: This was an observational, single-center, single-arm and investigator-initiated retrospective registry. In this all-comers registry, patients who underwent implantation of Tetrilimus EES for treatment of coronary artery disease during routine clinical practice between February-2016 and August-2016 at tertiary care center of India were included. Primary endpoint was occurrence of any major adverse cardiac event (MACE) up to 12 months' follow-up. MACE was a composite of cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). Similar endpoints were observed in sub-group patients. RESULTS: Total 766 stents were implanted to treat 695 lesions in 558 patients. Of treated lesions, 11.4% lesions were type B2 and 78.3% were type C lesions. In sub-group analysis of 143 patients, a total of 155 long coronary lesions were intervened successfully with only one stent been implanted per lesion. At 12 months' follow-up, four (0.7%) cases of cardiac death, eight (1.4%) of MI, and two (0.4%) of TLR were reported, resulting in a 2.5% rate of MACE. The MACE rate was 2.8% in sub-group patients. CONCLUSIONS: Twelve months' clinical data demonstrated favorable safety and excellent performance of Tetrilimus EES in high-risk patients and complex coronary lesions in routine clinical practice and also in patients with ultra-long lesions.


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Implantes Absorvíveis , Idoso , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Stents , Resultado do Tratamento
3.
Minerva Med ; 111(6): 529-535, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32323934

RESUMO

BACKGROUND: The FLEX-LONG study assessed the safety and clinical outcomes of ultra-long (44 mm/48 mm) biodegradable polymer-coated Supraflex (Sahajanand Medical Technology Pvt. Ltd., Surat, India) sirolimus-eluting stents (SES) in real-world patients with complex, long coronary artery lesions. METHODS: It was an investigator-initiated, retrospective, non-randomized, observational and single-center study, which evaluated one-year results of 141 patients who had undergone implantation of at least one ultra-long (44 mm/48 mm) Supraflex SES. The incidence of major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR), at one-year follow-up was considered as primary outcome. Stent thrombosis was analyzed as a safety outcome. RESULTS: The mean age of the study population was 56.2±9.6 years and 78.0% (110/141) patients were male. The study analyzed high risk patients, including 62 (44.0%) hypertensive and 60 (42.6%) diabetic patients. Total 147 target lesions were treated, including 25 (17.0%) total occlusions. Total 51 (34.7%) and 96 (65.3%) Supraflex SES of 44 mm and 48 mm were implanted, respectively. Average stent length and diameter were 46.6±1.9 mm and 3.4±0.2 mm, respectively. One-year follow-up was obtained in 100% of patients. There was one probable stent thrombosis after three weeks. At one-year follow-up, 99.3% of patients remained event free. CONCLUSIONS: The results of the FLEX-LONG study support the use of ultra-long (44 mm/48 mm) Supraflex SES, in the treatment of high-risk real-world patients. The stent appeared to be safe and effective at one-year with low clinical events in complex, long coronary artery lesions.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Imunossupressores/administração & dosagem , Desenho de Prótese , Sirolimo/administração & dosagem , Implantes Absorvíveis/efeitos adversos , Implantes Absorvíveis/estatística & dados numéricos , Doença da Artéria Coronariana/patologia , Diabetes Mellitus/epidemiologia , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/estatística & dados numéricos , Feminino , Humanos , Hipercolesterolemia/epidemiologia , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fumantes/estatística & dados numéricos , Trombose/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA