RESUMO
To date, poly- and perfluoroalkyl substances (PFAS) represent a real threat for their environmental persistence, wide physicochemical variability, and their potential toxicity. Thus far a large portion of these chemicals remain structurally unknown. These chemicals, therefore, require the implementation of complex non-targeted analysis workflows using liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) for their comprehensive detection and monitoring. This approach, even though comprehensive, does not always provide the much-needed analytical resolution for the analysis of complex PFAS mixtures such as fire-fighting aqueous film-forming foams (AFFFs). This study consolidates the advantages of the LC×LC technique hyphenated with high-resolution tandem mass spectrometry (HRMS/MS) for the identification of PFAS in AFFF mixtures. A total of 57 PFAS homolog series (HS) were identified in 3M and Orchidee AFFF mixtures thanks to the (i) high chromatographic peak capacity (n'2D,c ~ 300) and the (i) increased mass domain resolution provided by the "remainder of Kendrick Mass" (RKM) analysis on the HRMS data. Then, we attempted to annotate the PFAS of each HS by exploiting the available reference standards and the FluoroMatch workflow in combination with the RKM defect by different fluorine repeating units, such as CF2, CF2O, and C2F4O. This approach resulted in 12 identified PFAS HS, including compounds belonging to the HS of perfluoroalkyl carboxylic acids (PFACAs), perfluoroalkyl sulfonic acids (PFASAs), (N-pentafluoro(5)sulfide)-perfluoroalkane sulfonates (SF5-PFASAs), N-sulfopropyldimethylammoniopropyl perfluoroalkane sulfonamides (N-SPAmP-FASA), and N-carboxymethyldimethylammoniopropyl perfluoroalkane sulfonamide (N-CMAmP-FASA). The annotated categories of perfluoroalkyl aldehydes and chlorinated PFASAs represent the first record of PFAS HS in the investigated AFFF samples.
RESUMO
BACKGROUND: Polyesters are applied in high-end products in many industrial applications, including resins and powder-coating applications. The characterization of the chemical heterogeneities within a polyester is of utmost interest to develop new products or improve existing applications. Unfortunately, characterization is a difficult task, as polyesters may feature distributions in end-group functionality, molecular weight, chemical composition, and degree of branching. Currently, no analytical method can characterize all these interdependent distributions in a single analysis. RESULTS: We report the use of comprehensive normal-phase liquid chromatography × size-exclusion chromatography hyphenated with ultraviolet-light spectroscopy and high-resolution mass spectrometry in parallel (NPLC × SEC-UV/HRMS) to characterize polyesters according to their end-group-functionality and molecular-weight distributions. The chemical composition can be measured with HRMS, while relative quantitation can be performed with UV detection. A supercharging agent was used during ionization allowing to extend the molecular-weight range of the detected chemical species. SIGNIFICANCE: The presented platform allows characterization of polyesters with varying fractions of carboxyl or hydroxyl end-group functionalities and varying distributions of molecular weight, degree of branching, and chemical compositions. The number-average and weight-average molar masses are obtained in the same analysis. This information cannot be obtained by any one-dimensional technique. The developed NPLC × SEC-UV/HRMS platform is a valuable tool for characterizing polyesters in an industrial setting.
RESUMO
Protein glycosylation is implicated in a wide array of diseases, yet glycoprotein analysis remains elusive owing to the extreme heterogeneity of glycans, including microheterogeneity of some of the glycosites (amino acid residues). Various mass spectrometry (MS) strategies have proven tremendously successful for localizing and identifying glycans, typically utilizing a bottom-up workflow in which glycoproteins are digested to create glycopeptides to facilitate analysis. An emerging alternative is top-down MS that aims to characterize intact glycoproteins to allow precise identification and localization of glycans. The most comprehensive characterization of intact glycoproteins requires integration of a suitable separation method and high performance tandem mass spectrometry to provide both protein sequence information and glycosite localization. Here, we couple ultraviolet photodissociation and hydrophilic interaction chromatography with high resolution mass spectrometry to advance the characterization of intact glycoproteins ranging from 15 to 34 kDa, offering site localization of glycans, providing sequence coverages up to 93%, and affording relative quantitation of individual glycoforms.
Assuntos
Glicoproteínas , Interações Hidrofóbicas e Hidrofílicas , Polissacarídeos , Espectrometria de Massas em Tandem , Raios Ultravioleta , Polissacarídeos/análise , Polissacarídeos/química , Glicoproteínas/química , Glicoproteínas/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Glicosilação , Sequência de Aminoácidos , Humanos , Glicopeptídeos/análise , Glicopeptídeos/químicaRESUMO
End groups of poly(Lactide-co-glycolide) (PLGA) play an important role in determining the properties of polymers for use in drug delivery systems. For instance, it has been reported that the encapsulation efficiency in PLGA microspheres varies significantly between ester-terminated and acid-terminated PLGA. More importantly, the in-vivo degradation time of such polymer excipients is influenced by the functional end-group of the copolymer used. The end group distribution in PLGA polymers has been studied using electrospray and matrix-assisted laser-desorption/ionization - high-resolution mass spectrometry. In both cases, the application of these methods is typically limited to PLGA having a molecular weight of up to 4 kDa. 13Carbon-nuclear-magnetic-resonance has also been reported as a method to differentiate and quantify PLGA end groups with a molecular weight up to 136 kDa. However, reported NMR methods take over 12 h per sample, limiting throughput.Cryoprobe NMR can reduce the time required for the process, however such NMR equipment is costly, which makes it unsuitable for the quality control of PLGA. Here, we present a normal-phase liquid chromatography method capable of resolving functionality type distribution (FTD) and, partially, chemical composition distribution (CCD) in commercial PLGA polymers obtained from ring opening polymerization. This method can separate PLGA polymers with a molecular weight of up to 183.0 kDa while also enabling the simultaneous separation of the difference of Lactic acid (LA)/Glycolic acid (GA) ratios. To achieve this, a cross-linked diol column was used with a ternary gradient from HEX to 0.1 % v/v TEA in EA to 0.1 % v/v FA in THF to allow first for the elution of mono-ester terminated PLGA, followed by the di-acid terminated. In addition, a separation of ester-terminated PLGA in the difference of the LA/GA ratio was achieved. This method is expected to aid in understanding the correlation between PLGA's FTD, CCD, and physical properties, facilitating product development and quality control.
Assuntos
Ácido Poliglicólico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Peso Molecular , Ácido Láctico/química , Cromatografia Líquida/métodos , Espectroscopia de Ressonância Magnética , Concentração de Íons de HidrogênioRESUMO
Physiological phenomena exhibit complex behaviours arising at multiple time scales. To investigate them, techniques derived from chaos theory were applied to physiological signals, providing promising results in distinguishing between healthy and pathological states. Fractal-like properties of electrodermal activity (EDA), a well-validated tool for monitoring the autonomic nervous system state, have been reported in previous literature. This study proposes the multiscale complexity index of electrodermal activity (MComEDA) to discern different autonomic responses based on EDA signals. This method builds upon our previously proposed algorithm, ComEDA, and it is empowered with a coarse-graining procedure to provide a view at multiple time scales of the EDA response. We tested MComEDA's performance on the EDA signals of two publicly available datasets, i.e., the Continuously Annotated Signals of Emotion (CASE) dataset and the Affect, Personality and Mood Research on Individuals and Groups (AMIGOS) dataset, both containing physiological data recorded from healthy participants during the view of ultra-short emotional video clips. Our results highlighted that the values of MComEDA were significantly different (p-value < 0.05 after Wilcoxon signed rank test with Bonferroni's correction) when comparing high- and low-arousal stimuli. Furthermore, MComEDA outperformed the single-scale approach in discriminating among different valence levels of high-arousal stimuli, e.g., showing significantly different values for scary and amusing stimuli (p-value = 0.024). These findings suggest that a multiscale approach to the nonlinear analysis of EDA signals can improve the information gathered on task-specific autonomic response, even when ultra-short time series are considered.
RESUMO
Despite the high gain in peak capacity, online comprehensive two-dimensional liquid chromatography coupled with high-resolution mass spectrometry (LC × LC-HRMS) has not yet been widely applied to the analysis of complex protein digests. One reason is the method's reduced sensitivity which can be linked to the high flow rates of the second separation dimension (2D). This results in higher dilution factors and the need for flow splitters to couple to ESI-MS. This study reports proof-of-principle results of the development of an RPLC × RPLC-HRMS method using parallel gradients (2D flow rate of 0.7 mL min-1) and its comparison to shifted gradient methods (2D of 1.4 mL min-1) for the analysis of complex digests using HRMS (QExactive-Plus MS). Shifted and parallel gradients resulted in high surface coverage (SC) and effective peak capacity (SC of 0.6226 and 0.7439 and effective peak capacity of 779 and 757 in 60 min). When applied to a cell line digest sample, parallel gradients allowed higher sensitivity (e.g., average MS intensity increased by a factor of 3), allowing for a higher number of identifications (e.g., about 2600 vs 3900 peptides). In addition, reducing the modulation time to 10 s significantly increased the number of MS/MS events that could be performed. When compared to a 1D-RPLC method, parallel RPLC × RPLC-HRMS methods offered a higher separation performance (FHWH from 0.12 to 0.018 min) with limited sensitivity losses resulting in an increase of analyte identifications (e.g., about 6000 vs 7000 peptides and 1500 vs 1990 proteins).
Assuntos
Espectrometria de Massas , Proteínas , Cromatografia Líquida/métodos , Proteínas/análise , Proteínas/metabolismo , Humanos , Espectrometria de Massas/métodosRESUMO
The characterization of proteins and complexes in biological systems is essential to establish their critical properties and to understand their unique functions in a plethora of bioprocesses. However, it is highly difficult to analyze low levels of intact proteins in their native states (especially those exceeding 30 kDa) with liquid chromatography (LC)-mass spectrometry (MS). Herein, we describe for the first time the use of nanoflow ion-exchange chromatography directly coupled with native MS to resolve mixtures of intact proteins. Reference proteins and protein complexes with molecular weights between 10 and 150 kDa and a model cell lysate were separated using a salt-mediated pH gradient method with volatile additives. The method allowed for low detection limits (0.22 pmol of monoclonal antibodies), while proteins presented nondenatured MS (low number of charges and limited charge state distributions), and the oligomeric state of the complexes analyzed was mostly kept. Excellent chromatographic separations including the resolution of different proteoforms of large proteins (>140 kDa) and a peak capacity of 82 in a 30 min gradient were obtained. The proposed setup and workflows show great potential for analyzing diverse proteoforms in native top-down proteomics, opening unprecedented opportunities for clinical studies and other sample-limited applications.
Assuntos
Espectrometria de Massas , Cromatografia por Troca Iônica/métodos , Espectrometria de Massas/métodos , Proteínas/análise , Proteínas/química , Nanotecnologia , Humanos , Proteômica/métodos , Anticorpos Monoclonais/química , Anticorpos Monoclonais/análiseRESUMO
BACKGROUND: The non-enzymatic glycation of proteins and their advanced glycation end products (AGEs) are associated with protein transformations such as in the development of diseases and biopharmaceutical storage. The characterization of heavily glycated proteins at the intact level is of high interest as it allows to describe co-occurring protein modifications. However, the high heterogeneity of glycated protein makes this process challenging, and novel methods are required to accomplish this. RESULTS: In this study, we investigated two novel LC-HRMS methods to study glycated reference proteins at the intact protein level: low-flow hydrophilic-interaction liquid chromatography (HILIC) and native size-exclusion chromatography (SEC). Model proteins were exposed to conditions that favored extensive glycation and the formation of AGEs. After glycation, complicated MS spectra were observed, along with a sharply reduced signal response, possibly due to protein denaturation and the formation of aggregates. When using HILIC-MS, the glycated forms of the proteins could be resolved based on the number of reducing monosaccharides. Moreover, some positional glycated isomers were separated. The SEC-MS method under non-denaturing conditions provided insights into glycated aggregates but offered only a limited separation of glycated species based on molar mass. Overall, more than 25 different types of species were observed in both methods, differing in molar mass by 14-162 Da. 19 of these species have not been previously reported. SIGNIFICANCE: The proposed strategies show great potential to characterize highly glycated intact proteins from native and denaturing perspectives and provide new opportunities for fast clinical diagnoses and investigating glycation-related diseases.
Assuntos
Processamento de Proteína Pós-Traducional , Proteínas , Espectrometria de Massas/métodos , Cromatografia Líquida , Cromatografia em GelRESUMO
BACKGROUND: Therapeutic monoclonal antibodies (mAbs) comprise a large structural variability with respect to charge, size and post-translational modifications. These critical quality attributes (CQAs) need to be assessed during and after the production of mAbs. This normally requires off-line purification and sample preparation as well as several chromatographic selectivities, which makes the whole process time-consuming and error-prone. To improve on this, we developed an integrated and automated multi-dimensional analytical platform for the simultaneous assessment of multiple CQAs of mAbs in cell culture fluid (CCF) from upstream processes. RESULTS: The on-line system allows mAb characterization at the intact level, combining protein A affinity chromatography (ProtA) with size-exclusion, ion-exchange, and reversed-phase liquid chromatographic modes with UV and mass spectrometric detection. Multiple heart cuts of a single mAb elution band from ProtA are stored in 20-µL loops and successively sent to the multimethod options in the second dimension. ProtA loading and elution conditions and their compatibility with second-dimension LC modes were studied and optimized. Subsequently, heart-cutting and valve-switching schemes were investigated to achieve effective and reproducible analyses. The applicability of the developed workflow was demonstrated by the direct analysis (i.e. not requiring off-line sample preparation) of a therapeutic mAb in CCF, obtaining useful information on accurate molecular mass, glycosylation, and charge and size variants of the mAb product at the same time and in just over 1 h. SIGNIFICANCE: The developed multidimensional platform is the first system that allows for multiple fractions from a single ProtA band to be characterized using different chromatographic selectivities in a single run allowing direct correlation between CQAs. The performance of the system is comparable to established off-line methods, fully compatible with upstream process samples, and provides a significant time-reduction of the characterization procedure.
Assuntos
Anticorpos Monoclonais , Técnicas de Cultura de Células , Fluxo de Trabalho , Cromatografia de Fase Reversa , GlicosilaçãoRESUMO
While the advent of modern analytical technology has allowed scientists to determine the complexity of mixtures, it also spurred the demand to understand these sophisticated mixtures better. Chemical transformation can be used to provide insights into properties of complex samples such as degradation pathways or molecular heterogeneity that are otherwise unaccessible. In this article, we explore how sample transformation is exploited across different application fields to empower analytical methods. Transformation mechanisms include molecular-weight reduction, controlled degradation, and derivatization. Both offline and online transformation methods have been explored. The covered studies show that sample transformation facilitates faster reactions (e.g. several hours to minutes), reduces sample complexity, unlocks new sample dimensions (e.g. functional groups), provides correlations between multiple sample dimensions, and improves detectability. The article highlights the state-of-the-art and future prospects, focusing in particular on the characterization of protein and nucleic-acid therapeutics, nanoparticles, synthetic polymers, and small molecules.
RESUMO
We constructed a high-performance biosensor for detecting uric acid by immobilizing an engineered urate oxidase on gold nanoparticles deposited on a carbon-glass electrode. This biosensor showed a low limit-of-detection (9.16 nM), a high sensitivity (14 µA/µM), a wide range of linearity (50 nM-1 mM), and more than 28 days lifetime.
Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Urato Oxidase , Ouro , Carbono , Eletrodos , Técnicas Eletroquímicas , Enzimas ImobilizadasRESUMO
Size-exclusion chromatography (SEC) employing aqueous mobile phases with volatile salts at neutral pH combined with native mass spectrometry (nMS) is a valuable tool to characterize proteins and protein aggregates in their native state. However, the liquid-phase conditions (high salt concentrations) frequently used in SEC-nMS hinder the analysis of labile protein complexes in the gas phase, necessitating higher desolvation-gas flow and source temperature, leading to protein fragmentation/dissociation. To overcome this issue, we investigated narrow SEC columns (1.0 mm internal diameter, I.D.) operated at 15-µL/min flow rates and their coupling to nMS for the characterization of proteins, protein complexes and higher-order structures (HOS). The reduced flow rate resulted in a significant increase in the protein-ionization efficiency, facilitating the detection of low-abundant impurities and HOS up to 230 kDa (i.e., the upper limit of the Orbitrap-MS instrument used). More-efficient solvent evaporation and lower desolvation energies allowed for softer ionization conditions (e.g., lower gas temperatures), ensuring little or no structural alterations of proteins and their HOS during transfer into the gas phase. Furthermore, ionization suppression by eluent salts was decreased, permitting the use of volatile-salt concentrations up to 400 mM. Band broadening and loss of resolution resulting from the introduction of injection volumes exceeding 3% of the column volume could be circumvented by incorporating an online trap-column containing a mixed-bed ion-exchange (IEX) material. The online IEX-based solid-phase extraction (SPE) or "trap-and-elute" set-up provided on-column focusing (sample preconcentration). This allowed the injection of large sample volumes on the 1-mm I.D. SEC column without compromising the separation. The enhanced sensitivity attained by the micro-flow SEC-MS, along with the on-column focusing achieved by the IEX precolumn, provided picogram detection limits for proteins.
Assuntos
Proteínas , Sais , Espectrometria de Massas/métodos , Cromatografia em Gel , Proteínas/análise , Cromatografia Líquida de Alta Pressão/métodosRESUMO
Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a â¼40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.
Assuntos
Glicoproteínas , Indicadores e Reagentes , Cromatografia Líquida/métodos , Glicoproteínas/química , Espectrometria de Massas , Íons , Interações Hidrofóbicas e HidrofílicasRESUMO
In this research, we developed an online comprehensive two-dimensional liquid chromatographic (LC × LC) method hyphenated with high-resolution mass spectrometry (HRMS) for the non-targeted identification of poly- and perfluorinated compounds (PFASs) in fire-fighting aqueous-film forming foams (AFFFs). The method exploited the combination of mixed-mode weak anion exchange-reversed phase with a octadecyl stationary phase, separating PFASs according to ionic classes and chain length. To develop and optimize the LC × LC method we used a reference training set of twenty-four anionic PFASs, representing the main classes of compounds occurring in AFFFs and covering a wide range of physicochemical properties. In particular, we investigated different modulation approaches to reduce injection band broadening and breakthrough in the second dimension separation. Active solvent and stationary phase assisted modulations were compared, with the best results obtained with the last approach. In the optimal conditions, the predicted peak capacity corrected for undersampling was higher than three-hundred in a separation space of about 60 min. Subsequently, the developed method was applied to the non-targeted analysis of two AFFF samples for the identification of homologous series of PFASs, in which it was possible to identify up to thirty-nine potential compounds of interest utilizing Kendrick mass defect analysis. Even within the samples, the features considered potential PFAS by mass defect analysis elute in the chromatographic regions discriminating for the ionic group and/or the chain length, thus confirming the applicability of the method presented for the analysis of AFFF mixtures and, to a further extent, of environmental matrices affected by the AFFF.
Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Fluorocarbonos/análise , Poluentes Químicos da Água/análise , Água/química , Espectrometria de Massas , Solventes/análise , Cefotaxima/análiseRESUMO
SARS-CoV-2 cellular infection is mediated by the heavily glycosylated spike protein. Recombinant versions of the spike protein and the receptor-binding domain (RBD) are necessary for seropositivity assays and can potentially serve as vaccines against viral infection. RBD plays key roles in the spike protein's structure and function, and thus, comprehensive characterization of recombinant RBD is critically important for biopharmaceutical applications. Liquid chromatography coupled to mass spectrometry has been widely used to characterize post-translational modifications in proteins, including glycosylation. Most studies of RBDs were performed at the proteolytic peptide (bottom-up proteomics) or released glycan level because of the technical challenges in resolving highly heterogeneous glycans at the intact protein level. Herein, we evaluated several online separation techniques: (1) C2 reverse-phase liquid chromatography (RPLC), (2) capillary zone electrophoresis (CZE), and (3) acrylamide-based monolithic hydrophilic interaction chromatography (HILIC) to separate intact recombinant RBDs with varying combinations of glycosylations (glycoforms) for top-down mass spectrometry (MS). Within the conditions we explored, the HILIC method was superior to RPLC and CZE at separating RBD glycoforms, which differ significantly in neutral glycan groups. In addition, our top-down analysis readily captured unexpected modifications (e.g., cysteinylation and N-terminal sequence variation) and low abundance, heavily glycosylated proteoforms that may be missed by using glycopeptide data alone. The HILIC top-down MS platform holds great potential in resolving heterogeneous glycoproteins for facile comparison of biosimilars in quality control applications.
Assuntos
Medicamentos Biossimilares , COVID-19 , Cromatografia Líquida , Cromatografia de Fase Reversa/métodos , Glicoproteínas/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas , Polissacarídeos/análise , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/químicaRESUMO
Comprehensive two-dimensional liquid chromatography (LC × LC) is an attractive separation technique that allows achieving high peak capacities and information on chemical correlations. Unfortunately, its application in industrial practice is still not widespread due to limiting factors such as complex method development, tedious method optimization and solvent-incompatibility (such as solvent-strength mismatch or immiscibility experienced during fraction transfer). A severe case of solvent-incompatibility is encountered in the comprehensive coupling of normal-phase LC and reversed-phase LC (NPLC × RPLC). NPLC × RPLC is considered a desirable LC × LC system, especially for the characterization of synthetic polymers, due to the high orthogonality of the two retention mechanisms. However, its experimental realization often suffers from solvent-injection effects in the RPLC dimension, such as peak-deformation, peak-splitting, or even unretained elution ("breakthrough") of sample components. Such a decrease in performance or loss of retention is highly dependent on the types of solvents used. To explore the boundaries of solvent compatibility, we applied large-volume injections (LVI) of reference analytes (e.g. alkyl benzenes; ethoxylate and propoxylate polymers) dissolved in water-immiscible sample solvents, such as dichloromethane, n-hexane, and isooctane in fast water-based gradient RPLC separations (using methanol or acetonitrile as eluent). It was found that, when using highly aqueous initial gradient conditions, hydrophobic sample diluents were retained and eluted during the applied gradient. Depending on the relative retention of the retained diluent and the sample analytes, good chromatograms for LVI of immiscible solvents were obtained, comparable with injections under ideal conditions. The conclusions from injection experiments in aqueous RPLC were verified by coupling an NPLC system with a gradient from isooctane to tetrahydrofuran and an RPLC system with a gradient from water to acetonitrile in an online comprehensive NPLC × RPLC separation of a mixture of propoxylate polymers. The separation provided separation of the polymers based on their number of hydroxyl end-groups (NPLC) and oligomer chain-length (RPLC), without suffering from significant band-broadening effects due to solvent-mismatch upon injection in the second-dimension RPLC system.
Assuntos
Cromatografia de Fase Reversa , Água , Interações Hidrofóbicas e Hidrofílicas , Polímeros , SolventesRESUMO
In this study, we optimized a polymerization mixture to synthesize poly(acrylamide-co-N,N'-methylenebisacrylamide) monolithic stationary phases for hydrophilic-interaction chromatography (HILIC) of intact proteins. Thermal polymerization was performed, and the effects of varying the amount of cross-linker and the porogen composition on the separation performance of the resulting columns were studied. The homogeneity of the structure and the different porosities were examined through scanning electron microscopy (SEM). Further characterization of the monolithic structure revealed a permeable (Kf between 2.5 × 10-15 and 1.40 × 10-13 m2) and polar stationary phase suitable for HILIC. The HILIC separation performance of the different columns was assessed using gradient separation of a sample containing four intact proteins, with the best performing stationary phase exhibiting a peak capacity of 51 in a gradient of 25 min. Polyacrylamide-based materials were compared with a silica-based particulate amide phase (2.7 µm core-shell particles). The monolith has no residual silanol sites and, therefore, fewer sites for ion-exchange interactions with proteins. Thus, it required lower concentrations of ion-pair reagent in HILIC of intact proteins. When using 0.1% of trifluoroacetic acid (TFA), the peak capacities of the two columns were similar (30 and 34 for the monolithic and packed column, respectively). However, when decreasing the concentration of TFA to 0.005%, the monolithic column maintained similar separation performance and selectivity (peak capacity 23), whereas the packed column showed greatly reduced performance (peak capacity 12), lower selectivity, and inability to elute all four reference proteins. Finally, using a mobile phase containing 0.1% formic acid and 0.005% TFA, the HILIC separation on the monolithic column was successfully hyphenated with high-resolution mass spectrometry. Detection sensitivity for protein and glycoproteins was increased and the amount of adducts formed was decreased in comparison with separations performed at 0.1% TFA.
Assuntos
Acrilamidas , Resinas Acrílicas , Cromatografia Líquida , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas , Ácido TrifluoracéticoRESUMO
Understanding the relation between chemical characteristics and properties of synthetic polymers is one of the challenges faced by analytical chemists in industry. This is a complex task, as polymers are not synthesized as single molecule, but are populations of chemically similar compounds with distributions over several properties. The latter include, for example, molecular weight, nature of end-groups (functionality), and chemical composition. In this paper, comprehensive two-dimensional liquid chromatography was used to determine the combined functionality-type and molecular-weight distributions of hydroxyfunctionalized propoxylates. Propoxylates derived from different initiators (one up to eight terminal hydroxyl groups) were separated in the first dimension using a gradient normal-phase LC separation (NPLC). In the second dimension ultra-high pressure size-exclusion chromatography separation (UHPSEC), further speciating distributions based on molecular size. The developed NPLC × SEC method with evaporative light-scattering detection can be used for the fast screening (< 30 min) of mutually dependent functionality-type and molecular-weight distributions of unknown propoxylates.
Assuntos
Polímeros , Cromatografia em Gel , Cromatografia Líquida , Peso MolecularRESUMO
Trifluoroacetic acid (TFA) is commonly used as mobile phase additive to improve retention and peak shape characteristics in hydrophilic interaction liquid chromatography (HILIC) of intact proteins. However, when using electrospray ionization-mass spectrometry (ESI-MS) detection, TFA may cause ionization suppression and adduct formation, leading to reduced analyte sensitivity. To address this, we describe a membrane-based microfluidic chip with multiple parallel channels for the selective post-column removal of TFA anions from HILIC. An anion-exchange membrane was used to physically separate the column effluent from a stripper flow solution comprising acetonitrile, formic acid, and propionic acid. The exchange of ions allowed the post-column removal of TFA used during HILIC separation of model proteins. The multichannel design of the device allows the use of flow rates of 0.2 mL/min without the need for a flow splitter, using mobile phases containing 0.1% TFA (13 mM). Separation selectivity and efficiency were maintained (with minor band broadening effects) while increasing the signal intensity and peak areas by improving ionization and reducing TFA adduct formation.