Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
2.
J Clin Virol ; 146: 105049, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34871906

RESUMO

BACKGROUND: The highly transmissible Delta variant of SARS-CoV-2 (B.1.617.2), first identified in India, is currently replacing pre-existing variants in many parts of the world. To help guide public health policies it is important to monitor efficiently its spread. Genome sequencing is the gold standard for identification of Delta, but is time-consuming, expensive, and unavailable in many regions. OBJECTIVE: To develop and evaluate a rapid, simple and inexpensive alternative to sequencing for Delta identification. METHODS: A double-mismatch allele-specific RT-PCR (DMAS-RT-PCR) was developed. The technique exploits allele-specific primers, targeting two spike gene mutations, L452R and T478K, within the same amplicon. The discriminatory power of each primer was enhanced by an additional mismatch located at the fourth nucleotide from the 3' end. Specificity was assessed by testing well characterised cell culture-derived viral isolates and clinical samples, most of which had previously been fully sequenced. RESULTS: In all cases the results of viral genotyping by DMAS-RT-PCR were entirely concordant with the results of sequencing, and the assay was shown to discriminate reliably between the Delta variant and other variants (Alpha and Beta), and 'wild-type' SARS-CoV-2. Influenza A and RSV were non-reactive in the assay. The sensitivity of DMAS-RT-PCR matched that of the diagnostic SARS-CoV-2 RT-qPCR screening assay. Several samples that could not be sequenced due to insufficient virus were successfully genotyped by DMAS-RT-PCR. CONCLUSION: The method we describe would be simple to establish in any laboratory that can conduct PCR assays and should greatly facilitate monitoring of the spread of the Delta variant globally.


Assuntos
COVID-19 , SARS-CoV-2 , Alelos , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Transcrição Reversa , Sensibilidade e Especificidade
3.
Sci Rep ; 11(1): 14283, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34253796

RESUMO

There is increasing evidence that endogenous retroviruses (ERVs) play a significant role in central nervous system diseases, including amyotrophic lateral sclerosis (ALS). Studies of ALS have consistently identified retroviral enzyme reverse transcriptase activity in patients. Evidence indicates that ERVs are the cause of reverse transcriptase activity in ALS, but it is currently unclear whether this is due to a specific ERV locus or a family of ERVs. We employed a combination of bioinformatic methods to identify whether specific ERVs or ERV families are associated with ALS. Using the largest post-mortem RNA-sequence datasets available we selectively identified ERVs that closely resembled full-length proviruses. In the discovery dataset there was one ERV locus (HML6_3p21.31c) that showed significant increased expression in post-mortem motor cortex tissue after multiple-testing correction. Using six replication post-mortem datasets we found HML6_3p21.31c was consistently upregulated in ALS in motor cortex and cerebellum tissue. In addition, HML6_3p21.31c showed significant co-expression with cytokine binding and genes involved in EBV, HTLV-1 and HIV type-1 infections. There were no significant differences in ERV family expression between ALS and controls. Our results support the hypothesis that specific ERV loci are involved in ALS pathology.


Assuntos
Esclerose Lateral Amiotrófica/virologia , Retrovirus Endógenos/genética , Córtex Motor/metabolismo , Idoso , Esclerose Lateral Amiotrófica/metabolismo , Esclerose Lateral Amiotrófica/mortalidade , Animais , Cerebelo/metabolismo , Córtex Cerebral/metabolismo , Biologia Computacional , Citocinas/metabolismo , Bases de Dados Factuais , Feminino , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , HIV/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Provírus/genética , RNA-Seq
4.
J Virol Methods ; 294: 114174, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33984396

RESUMO

There is growing evidence that measurement of SARS-CoV-2 viral copy number can inform clinical and public health management of SARS-CoV-2 carriers and COVID-19 patients. Here we show that quantification of SARS-CoV-2 is feasible in a clinical setting, using a duplex RT-qPCR assay which targets both the E gene (Charité assay) and a human RNA transcript, RNase P (CDC assay) as an internal sample sufficiency control. Samples in which RNase P is not amplified indicate that sample degradation has occurred, PCR inhibitors are present, RNA extraction has failed or swabbing technique was insufficient. This important internal control reveals that 2.4 % of nasopharyngeal swabs (15/618 samples) are inadequate for SARS-CoV-2 testing which, if not identified, could result in false negative results. We show that our assay is linear across at least 7 logs and is highly reproducible, enabling the conversion of Cq values to viral copy numbers using a standard curve. Furthermore, the SARS-CoV-2 copy number was independent of the RNase P copy number indicating that the per-swab viral copy number is not dependent on sampling- further allowing comparisons between samples. The ability to quantify SARS-CoV-2 viral copy number will provide an important opportunity for viral burden-guided public health and clinical decision making.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/normas , RNA Viral/genética , SARS-CoV-2/genética , Manejo de Espécimes/normas , COVID-19/diagnóstico , COVID-19/virologia , Dosagem de Genes , Genes Essenciais , Humanos , Limite de Detecção , RNA Viral/isolamento & purificação , Padrões de Referência , Ribonuclease P/genética , Manejo de Espécimes/métodos , Carga Viral
7.
J Virol Methods ; 268: 17-23, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30871982

RESUMO

Dengue is a vector-transmitted viral infection that is a significant cause of morbidity and mortality in humans worldwide, with over 50 million apparent cases and a fatality rate of 2.5 % of 0.5 million severe cases per annum in recent years. Four serotypes are currently co-circulating. Diagnosis of infection may be by polymerase chain reaction, serology or rapid antigen test for NS1. Both pan-serotype and serotype-specific genome detection assays have been described, however, achieving adequate sensitivity with pan-serotype assays has been challenging. Indeed, as we show here, inspection of components and cycling parameters of a pan-serotype RT-qPCR assay in use in laboratories worldwide revealed insufficient probe stability to accommodate potential nucleotide mismatches, resulting in false-negatives. A minor-groove binder (MGB)-modified version of the probe was designed and its performance compared with that of the original probe in 32 samples. Eight of the samples were undetected by the original probe but detected by the MGB modified probe and six out of seven of these that could be serotyped belonged to serotype 4. Sequencing of the region targeted by the probe in these samples revealed two mismatches which were also universally present in all other serotype 4 sequences in a public database. We therefore recommend adoption of this MGB modification in order to reduce the risk of false-negative results, especially with dengue serotype 4 infections.


Assuntos
Sondas de DNA/genética , Vírus da Dengue/isolamento & purificação , Dengue/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sítios de Ligação , Dengue/sangue , Reações Falso-Negativas , Humanos , Hidrólise , RNA Viral/sangue , Sensibilidade e Especificidade , Sorogrupo
8.
Acta Neuropathol Commun ; 7(1): 45, 2019 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-30885274

RESUMO

Over the past two decades a number of studies have demonstrated activity of the retroviral enzyme reverse transcriptase in the serum of patients with sporadic amyotrophic lateral sclerosis (ALS). Known human exogenous retroviruses such as HIV-1 have been eliminated as possible sources of this activity and investigators have therefore considered the possibility that human endogenous retroviruses (HERVs) might be involved. HERV-K (HML-2) is the most recent retroviral candidate to be proposed following the observation of elevated HERV-K expression in cortical and spinal neurons of ALS patients and the demonstration of HERV-K envelope protein neurotoxicity in vitro and in transgenic mice. This retroviral hypothesis is an attractive one, not least because it raises the possibility that ALS might become treatable using antiretroviral drugs. In the present study we have attempted independent confirmation of the observation that HERV-K RNA levels are elevated in ALS brain. Total RNA was extracted from the postmortem premotor cortex of 34 patients with ALS and 23 controls. Quantitative real-time reverse transcription PCR (RT-qPCR) was performed according to the MIQE guidelines using HERV-K gag, pol and env primer sets. Data was analysed by the 2-∆∆Ct method with normalisation against two reference genes, GAPDH and XPNPEP1. Geometric mean HERV-K RNA expression levels in the premotor cortex of ALS patients were not found to be different from the expression levels in non-ALS controls. Our findings do not confirm the recently reported association between elevated cortical HERV-K RNA levels and ALS, and thus raise doubts about the role of this endogenous retrovirus in ALS pathogenesis. The results of this study may have implications for ongoing clinical trials aiming to suppress HERV-K activity with antiretroviral drugs.


Assuntos
Esclerose Lateral Amiotrófica/metabolismo , Córtex Motor/metabolismo , RNA/biossíntese , Proteínas Virais/biossíntese , Idoso , Esclerose Lateral Amiotrófica/genética , Esclerose Lateral Amiotrófica/patologia , Retrovirus Endógenos/genética , Retrovirus Endógenos/metabolismo , Feminino , Expressão Gênica , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Motor/patologia , RNA/genética , Proteínas Virais/genética
9.
Open Forum Infect Dis ; 6(3): ofz048, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30882014

RESUMO

BACKGROUND: Japanese encephalitis virus (JEV) is a leading cause of central nervous system (CNS) infections in Asia and results in significant morbidity and mortality. JEV RNA is rarely detected in serum or cerebrospinal fluid (CSF), and diagnosis of JEV infection is usually based on serological tests that are frequently difficult to interpret. Unlike serum or CSF, urine is relatively easy to obtain, but, to date, there has been minimal work on the feasibility of testing urine for JEV RNA. METHODS: We investigated the use of lysis buffer and a Microsep device to optimize urine storage for detection of JEV RNA by reverse transcription real-time polymerase chain reaction (RT-qPCR). The best of the studied methods was then evaluated in consecutive patients admitted to the hospital with suspected CNS infections in Laos. RESULTS: We demonstrated degradation of JEV RNA in urine after even short storage periods at 4°C or -80°C. Although there was no advantage in using a Microsep concentration device alone, immediate addition of lysis buffer to fresh urine improved the detection of JEV RNA at the limit of detection. CONCLUSIONS: In 2 studies of 41 patients with acute encephalitis syndrome, 11 (27%) were positive for JEV IgM in CSF and/or serum, and 2 (4.9%) were JEV RT-qPCR positive from throat swabs. JEV RNA was not detected in any of these patients' urine samples. However, lysis buffer was only used during a prospective study, that is, for only 17/41 (41%) patient urine samples. Our findings suggest a need for larger studies testing urine for JEV RNA, with urine collected at different times from symptom onset, and using lysis buffer, which stabilizes RNA, for storage.

10.
PLoS One ; 13(3): e0194412, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29570739

RESUMO

BACKGROUND: Japanese encephalitis virus (JEV) is a major cause of encephalitis in Asia, and the commonest cause of mosquito-borne encephalitis worldwide. Detection of JEV RNA remains challenging due to the characteristic brief and low viraemia, with 0-25% of patients positive, and the mainstay of diagnosis remains detection of anti-JEV IgM antibody. METHODS: We performed a systematic review of published RT-PCR protocols, and evaluated them in silico and in vitro alongside new primers and probes designed using a multiple genome alignment of all JEV strains >9,000nt from GenBank, downloaded from the NCBI website (November 2016). The new assays included pan-genotype and genotype specific assays targeting genotypes 1 and 3. RESULTS: Ten RT-qPCR assays were compared, a pre-existing in-house assay, three published assays and six newly designed assays, using serial RNA dilutions. We selected three assays, one published and two novel assays, with the lowest limit of detection (LOD) for further optimisation and validation. One of the novel assays, detecting NS2A, showed the best results, with LOD approximately 4 copies/ reaction, and no cross-reaction on testing closely related viruses in the JEV serocomplex, West Nile Virus and St. Louis Virus. The optimised assays were validated in consecutive patients with central nervous system infections admitted to hospitals in Laos, testing paired CSF and serum samples. CONCLUSIONS: We succeeded in developing a JEV specific RT-qPCR assay with at least 1 log10 improved sensitivity as compared to existing assays. Further evaluation is required, field-testing the assay in a larger group of patients.


Assuntos
Vírus da Encefalite Japonesa (Espécie)/genética , Encefalite Japonesa/diagnóstico , Encefalite Japonesa/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Ásia/epidemiologia , Encefalite Japonesa/epidemiologia , Humanos
11.
Sci Rep ; 7(1): 1209, 2017 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-28446770

RESUMO

ABTRACT: Establishing a cure for HIV is hindered by the persistence of latently infected cells which constitute the viral reservoir. Real-time qPCR, used for quantification of this reservoir by measuring HIV DNA, requires external calibration; a common choice of calibrator is the 8E5 cell line, which is assumed to be stable and to contain one HIV provirus per cell. In contrast, digital PCR requires no external calibration and potentially provides 'absolute' quantification. We compared the performance of qPCR and dPCR in quantifying HIV DNA in 18 patient samples. HIV DNA was detected in 18 by qPCR and in 15 by dPCR, the difference being due to the smaller sample volume analysed by dPCR. There was good quantitative correlation (R2 = 0.86) between the techniques but on average dPCR values were only 60% of qPCR values. Surprisingly, investigation revealed that this discrepancy was due to loss of HIV DNA from the 8E5 cell calibrant. 8E5 extracts from two other sources were also shown to have significantly less than one HIV DNA copy per cell and progressive loss of HIV from 8E5 cells during culture was demonstrated. We therefore suggest that the copy number of HIV in 8E5 extracts be established by dPCR prior to use as calibrator.


Assuntos
DNA Viral/análise , Erros de Diagnóstico , Infecções por HIV/diagnóstico , HIV/genética , Reação em Cadeia da Polimerase/normas , Carga Viral/normas , Calibragem , Linhagem Celular , DNA Viral/genética , Humanos , Reação em Cadeia da Polimerase/métodos , Carga Viral/métodos
12.
Biomol Detect Quantif ; 10: 31-33, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27990347

RESUMO

Digital PCR (dPCR) has been reported to be more precise and sensitive than real-time quantitative PCR (qPCR) in a variety of models and applications. However, in the majority of commercially available dPCR platforms, the dynamic range is dependent on the number of partitions analysed and so is typically limited to four orders of magnitude; reduced compared with the typical seven orders achievable by qPCR. Using two different biological models (HIV DNA analysis and KRAS genotyping), we have demonstrated that the RainDrop Digital PCR System (RainDance Technologies) is capable of performing accurate and precise quantification over six orders of magnitude thereby approaching that achievable by qPCR.

13.
Virology ; 492: 213-24, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26971243

RESUMO

HIV-1 infected patients who acquire HCV infection have higher rates of chronicity and liver disease progression than patients with HCV mono-infection. Understanding early events in this pathogenic process is important. We applied single genome sequencing of the E1 to NS3 regions and viral pseudotype neutralization assays to explore the consequences of viral quasispecies evolution from pre-seroconversion to chronicity in four co-infected individuals (mean follow up 566 days). We observed that one to three founder viruses were transmitted. Relatively low viral sequence diversity, possibly related to an impaired immune response, due to HIV infection was observed in three patients. However, the fourth patient, after an early purifying selection displayed increasing E2 sequence evolution, possibly related to being on suppressive antiretroviral therapy. Viral pseudotypes generated from HCV variants showed relative resistance to neutralization by autologous plasma but not to plasma collected from later time points, confirming ongoing virus escape from antibody neutralization.


Assuntos
Anticorpos Antivirais/imunologia , Hepacivirus/imunologia , Hepatite C Crônica/imunologia , Evasão da Resposta Imune , Proteínas do Envelope Viral/genética , Proteínas não Estruturais Virais/genética , Doença Aguda , Adulto , Linfócitos B/imunologia , Linfócitos B/patologia , Linfócitos B/virologia , Doença Crônica , Coinfecção , Progressão da Doença , Epitopos/genética , Epitopos/imunologia , Expressão Gênica , Infecções por HIV/imunologia , Infecções por HIV/patologia , Infecções por HIV/virologia , HIV-1/imunologia , HIV-1/patogenicidade , Hepacivirus/genética , Hepacivirus/patogenicidade , Hepatite C Crônica/patologia , Hepatite C Crônica/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Tipagem Molecular , Mutação , Testes de Neutralização , Filogenia , Linfócitos T Citotóxicos/imunologia , Linfócitos T Citotóxicos/patologia , Linfócitos T Citotóxicos/virologia , Linfócitos T Auxiliares-Indutores/imunologia , Linfócitos T Auxiliares-Indutores/patologia , Linfócitos T Auxiliares-Indutores/virologia , Proteínas do Envelope Viral/imunologia , Proteínas não Estruturais Virais/imunologia
14.
J Clin Microbiol ; 54(2): 392-400, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26659206

RESUMO

Digital PCR (dPCR) is being increasingly used for the quantification of sequence variations, including single nucleotide polymorphisms (SNPs), due to its high accuracy and precision in comparison with techniques such as quantitative PCR (qPCR) and melt curve analysis. To develop and evaluate dPCR for SNP detection using DNA, RNA, and clinical samples, an influenza virus model of resistance to oseltamivir (Tamiflu) was used. First, this study was able to recognize and reduce off-target amplification in dPCR quantification, thereby enabling technical sensitivities down to 0.1% SNP abundance at a range of template concentrations, a 50-fold improvement on the qPCR assay used routinely in the clinic. Second, a method was developed for determining the false-positive rate (background) signal. Finally, comparison of dPCR with qPCR results on clinical samples demonstrated the potential impact dPCR could have on clinical research and patient management by earlier (trace) detection of rare drug-resistant sequence variants. Ultimately this could reduce the quantity of ineffective drugs taken and facilitate early switching to alternative medication when available. In the short term such methods could advance our understanding of microbial dynamics and therapeutic responses in a range of infectious diseases such as HIV, viral hepatitis, and tuberculosis. Furthermore, the findings presented here are directly relevant to other diagnostic areas, such as the detection of rare SNPs in malignancy, monitoring of graft rejection, and fetal screening.


Assuntos
Antivirais/farmacologia , Farmacorresistência Viral , Vírus da Influenza A/efeitos dos fármacos , Vírus da Influenza A/genética , Influenza Humana/diagnóstico , Influenza Humana/virologia , Mutação , Antivirais/uso terapêutico , Genes Virais , Humanos , Vírus da Influenza A Subtipo H1N1/efeitos dos fármacos , Vírus da Influenza A Subtipo H1N1/genética , Influenza Humana/tratamento farmacológico , Tipagem Molecular , Oseltamivir/farmacologia , Polimorfismo de Nucleotídeo Único , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
15.
Clin Infect Dis ; 61(1): 120-8, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25778749

RESUMO

BACKGROUND: Emerging data relating to human immunodeficiency virus type 1 (HIV-1) cure suggest that vaccination to stimulate the host immune response, particularly cytotoxic cells, may be critical to clearing of reactivated HIV-1-infected cells. However, evidence for this approach in humans is lacking, and parameters required for a vaccine are unknown because opportunities to study HIV-1 reactivation are rare. METHODS: We present observations from a HIV-1 elite controller, not treated with combination antiretroviral therapy, who experienced viral reactivation following treatment for myeloma with melphalan and autologous stem cell transplantation. Mathematical modeling was performed using a standard viral dynamic model. Enzyme-linked immunospot, intracellular cytokine staining, and tetramer staining were performed on peripheral blood mononuclear cells; in vitro CD8 T-cell-mediated control of virion production by autologous CD4 T cells was quantified; and neutralizing antibody titers were measured. RESULTS: Viral rebound was measured at 28,000 copies/mL on day 13 post-transplant before rapid decay to <50 copies/mL in 2 distinct phases with t1/2 of 0.71 days and 4.1 days. These kinetics were consistent with an expansion of cytotoxic effector cells and killing of productively infected CD4 T cells. Following transplantation, innate immune cells, including natural killer cells, recovered with virus rebound. However, most striking was the expansion of highly functional HIV-1-specific cytotoxic CD8 T cells, at numbers consistent with those applied in modeling, as virus control was regained. CONCLUSIONS: These observations provide evidence that the human immune response is capable of controlling coordinated global HIV-1 reactivation, remarkably with potency equivalent to combination antiretroviral therapy. These data will inform design of vaccines for use in HIV-1 curative interventions.


Assuntos
Infecções por HIV/imunologia , Infecções por HIV/virologia , HIV-1/imunologia , HIV-1/fisiologia , Ativação Viral/imunologia , Anticorpos Neutralizantes/sangue , Linfócitos T CD4-Positivos/virologia , Linfócitos T CD8-Positivos/imunologia , Citocinas/análise , ELISPOT , Anticorpos Anti-HIV/sangue , Infecções por HIV/complicações , Humanos , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/virologia , Melfalan/efeitos adversos , Melfalan/uso terapêutico , Pessoa de Meia-Idade , Modelos Teóricos , Mieloma Múltiplo/tratamento farmacológico , Agonistas Mieloablativos/efeitos adversos , Agonistas Mieloablativos/uso terapêutico , Transplante de Células-Tronco/efeitos adversos , Subpopulações de Linfócitos T/imunologia , Transplante Autólogo
16.
Clin Infect Dis ; 60(6): 919-23, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25572898

RESUMO

Metagenomic next-generation sequencing (NGS) was used to diagnose an unusual and fatal case of progressive encephalitis in an immunocompromised adult presenting at disease onset as bilateral hearing loss. The sequencing and confirmatory studies revealed neuroinvasive infection of the brain by an astrovirus belonging to a recently discovered VA/HMO clade.


Assuntos
Infecções por Astroviridae/diagnóstico , Encefalite Viral/diagnóstico , Mamastrovirus/genética , Mamastrovirus/isolamento & purificação , Adulto , Encéfalo/patologia , Proteínas do Capsídeo/genética , Encefalite Viral/complicações , Evolução Fatal , Perda Auditiva Bilateral/etiologia , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Leucemia Linfoide/complicações , Filogenia
17.
Anal Chem ; 86(9): 4387-94, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24684191

RESUMO

Performing nucleic acid amplification techniques (NAATs) in digital format using limiting dilution provides potential advantages that have recently been demonstrated with digital polymerase chain reaction (dPCR). Key benefits that have been claimed are the ability to quantify nucleic acids without the need of an external calibrator and a greater resistance to inhibitors than real-time quantitative PCR (qPCR). In this study, we evaluated the performance of four NAATs, qPCR, dPCR, real-time quantitative loop mediated isothermal amplification (qLAMP), and digital LAMP (dLAMP), for the detection and quantification of human cytomegalovirus (hCMV). We used various DNA templates and inhibitors to compare the performance of these methods using a conventional real-time thermocycler platform (Bio-Rad CFX96) and a chip based digital platform (Fluidigm Biomark 12.765 Digital Array). dPCR performed well and demonstrated greater resistance to inhibitors than the other methods although this resistance did not apply equally to all inhibitors tested. dLAMP was found to be less sensitive than dPCR, but its quantitative performance was better than qLAMP, the latter being unable to quantify below 1000 copies. dLAMP was also more resistant to inhibitors than qLAMP. Unlike qPCR, both digital methods were able to quantify viral genomes without requiring a calibrator; however, neither can currently compete with the large reaction volumes, and thus the greater absolute sensitivity, of qPCR. With the introduction of digital instrumentation that will enable larger reaction volumes, digital amplification methods such as those evaluated in this study could potentially offer a robust alternative to qPCR for nucleic acid quantification.


Assuntos
Citomegalovirus/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Citomegalovirus/genética , DNA Viral/genética , Limite de Detecção
18.
Transfusion ; 54(3 Pt 2): 870-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23701338

RESUMO

BACKGROUND: Culture-based systems are currently the preferred means for bacterial screening of platelet (PLT) concentrates. Alternative bacterial detection techniques based on nucleic acid amplification have also been developed but these have yet to be fully evaluated. In this study we evaluate a novel 16S rDNA polymerase chain reaction (PCR) assay and compare its performance with automated culture. STUDY DESIGN AND METHODS: A total of 2050 time-expired, 176 fresh, and 400 initial-reactive PLT packs were tested by real-time PCR using broadly reactive 16S primers and a "universal" probe (TaqMan, Invitrogen). PLTs were also tested using a microbial detection system (BacT/ALERT, bioMérieux) under aerobic and anaerobic conditions. RESULTS: Seven of 2050 (0.34%) time-expired PLTs were found repeat reactive by PCR on the initial nucleic acid extract but none of these was confirmed positive on testing frozen second aliquots. BacT/ALERT testing also failed to confirm any time-expired PLTs positive on repeat testing, although 0.24% were reactive on the first test. Three of the 400 "initial-reactive" PLT packs were found by both PCR and BacT/ALERT to be contaminated (Escherichia coli, Listeria monocytogenes, and Streptococcus vestibularis identified) and 14 additional packs were confirmed positive by BacT/ALERT only. In 13 of these cases the contaminating organisms were identified as anaerobic skin or oral commensals and the remaining pack was contaminated with Streptococcus pneumoniae. CONCLUSION: These results demonstrate that the 16S PCR assay is less sensitive than BacT/ALERT and inappropriate for early testing of concentrates. However, rapid PCR assays such as this may be suitable for a strategy of late or prerelease testing.


Assuntos
Azidas/química , Plaquetas/citologia , DNA Ribossômico/química , Reação em Cadeia da Polimerase/métodos , Plaquetas/metabolismo , Humanos
20.
Clin Chem ; 59(6): 892-902, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23570709

RESUMO

There is growing interest in digital PCR (dPCR) because technological progress makes it a practical and increasingly affordable technology. dPCR allows the precise quantification of nucleic acids, facilitating the measurement of small percentage differences and quantification of rare variants. dPCR may also be more reproducible and less susceptible to inhibition than quantitative real-time PCR (qPCR). Consequently, dPCR has the potential to have a substantial impact on research as well as diagnostic applications. However, as with qPCR, the ability to perform robust meaningful experiments requires careful design and adequate controls. To assist independent evaluation of experimental data, comprehensive disclosure of all relevant experimental details is required. To facilitate this process we present the Minimum Information for Publication of Quantitative Digital PCR Experiments guidelines. This report addresses known requirements for dPCR that have already been identified during this early stage of its development and commercial implementation. Adoption of these guidelines by the scientific community will help to standardize experimental protocols, maximize efficient utilization of resources, and enhance the impact of this promising new technology.


Assuntos
Computadores/normas , Guias como Assunto , Reação em Cadeia da Polimerase em Tempo Real/normas , Computadores/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA