1.
Artigo em Inglês | MEDLINE | ID: mdl-18238692

RESUMO

Time domain correlation technique is a widely used method for blood flow velocity measurement. The time shift between a pair of windowed ultrasonic echoes is estimated by searching the temporal position of the maximum of the interpolated normalized correlation function. Between two consecutive echoes, the acoustical footprint of a group of scatterers, which are transported with the flow, moves and is deformed. This implies a decreasing of the amplitude of the normalized correlation coefficient. In the case of microcirculation (low flow rate, low SNR), the amplitude of the correlation peak can be used to detect the presence of blood flow and to discriminate false and true detections (reliability index). We have numerically evaluated the statistical performances of the cross-correlation algorithm used as a correlation peak amplitude estimator in severe conditions (short correlation window length, low SNR). These theoretical results have been compared with in vitro experimentation on a 100-/spl mu/m-diameter microcirculatory phantom and with in vivo experimentation on a 180-/spl mu/m-diameter vessel of a human leg carrying erysipelas.

2.
Skin Res Technol ; 6(4): 214-221, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11428960

RESUMO

BACKGROUND/AIMS: A new method for the in vivo characterization of the mechanical properties of skin has been developed. This comprises a suction chamber and an ultrasound device to measure both the vertical displacement of the skin's surface, and the skin's thickness. METHODS: A mathematical model of the mechanical behaviour of a taught elastic membrane is used to obtain a set of parameters intrinsic to the skin, such as Young's modulus (E) and the initial stress (sigma0), which reflect the stiffness and the natural tension of the skin, respectively. We also calculated an index of non-elasticity of the skin (unrestored energy ratio, UER), which takes into account the volume of tissue mobilized. It determines a ratio between the energy input to the skin and the energy it dissipates. These parameters were evaluated from the volar forearm of 10 normal male volunteers. RESULTS: The results were: 129+/-88 kPa for E, 13.5+/-5 kPa for sigma0, and 0.42+/-0.04 for UER; with reproducibilities of 9.5%, 12.4% and 6.4%, respectively. CONCLUSIONS: This new suction device was found useful for the study of the behaviour of the skin, and the device may be used for the evaluation of certain skin diseases and their therapy.

3.
Eur J Ultrasound ; 10(1): 53-63, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10502640

RESUMO

OBJECTIVE: This paper investigates the problems, advantages and potential applications of 20 MHz ultrasonic devices. METHOD: Aqueous gel and a thin appropriate membrane to enclose the front tip were used with 20 MHz probes without obvious decrease in resolution and sensitivity compared to the results obtained without a membrane and this considerably facilitates their routine use. RESULTS: Many applications with linear scanning were evaluated in dermatology, ophthalmology (investigations of the anterior chamber of the eye, checking of corneal grafts), stomatology (detection and evaluation of periodontal disease) and in the field of measurement of very low velocities in small vessels by means of a duplex probe comprising two 20 MHz transducers: an imaging transducer and an inclined blood flow measurement transducer. Velocity profiles (velocities less than 0.50 mm/s) were measured in 100-300 microm diameter vessels using a cross-correlation method. CONCLUSION: The use of 20 MHz frequency limits resolution but we have shown that this frequency allows the development of easy to handle probes.


Assuntos
Ultrassonografia/instrumentação , Velocidade do Fluxo Sanguíneo/fisiologia , Dermatologia/instrumentação , Desenho de Equipamento , Géis , Humanos , Membranas Artificiais , Oftalmologia/instrumentação , Medicina Bucal/instrumentação , Transdutores