Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
IEEE Trans Med Imaging ; 41(10): 2704-2714, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35442884

RESUMO

Non-invasive small-animal imaging technologies, such as optical imaging, magnetic resonance imaging and x -ray computed tomography, have enabled researchers to study normal biological phenomena or disease progression in their native conditions. However, existing small-animal imaging technologies often lack either the penetration capability for interrogating deep tissues (e.g., optical microscopy), or the functional and molecular sensitivity for tracking specific activities (e.g., magnetic resonance imaging). To achieve functional and molecular imaging in deep tissues, we have developed an integrated photoacoustic, ultrasound and acoustic angiographic tomography (PAUSAT) system by seamlessly combining light and ultrasound. PAUSAT can perform three imaging modes simultaneously with complementary contrast: high-frequency B-mode ultrasound imaging of tissue morphology, microbubble-enabled acoustic angiography of tissue vasculature, and multi-spectral photoacoustic imaging of molecular probes. PAUSAT can provide three-dimensional (3D) multi-contrast images that are co-registered, with high spatial resolutions at large depths. Using PAUSAT, we performed proof-of-concept in vivo experiments on various small animal models: monitoring longitudinal development of placenta and embryo during mouse pregnancy, tracking biodistribution and metabolism of near-infrared organic dye on the whole-body scale, and detecting breast tumor expressing genetically-encoded photoswitchable phytochromes. These results have collectively demonstrated that PAUSAT has broad applicability in biomedical research, providing comprehensive structural, functional, and molecular imaging of small animal models.


Assuntos
Técnicas Fotoacústicas , Angiografia , Animais , Imageamento Tridimensional , Camundongos , Imagem Molecular , Sondas Moleculares , Técnicas Fotoacústicas/métodos , Distribuição Tecidual , Tomografia/métodos , Ultrassonografia
2.
Hepatol Commun ; 6(7): 1827-1839, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35202510

RESUMO

Shear wave elastography (SWE) is an ultrasound-based stiffness quantification technology that is used for noninvasive liver fibrosis assessment. However, despite widescale clinical adoption, SWE is largely unused by preclinical researchers and drug developers for studies of liver disease progression in small animal models due to significant experimental, technical, and reproducibility challenges. Therefore, the aim of this work was to develop a tool designed specifically for assessing liver stiffness and echogenicity in small animals to better enable longitudinal preclinical studies. A high-frequency linear array transducer (12-24 MHz) was integrated into a robotic small animal ultrasound system (Vega; SonoVol, Inc., Durham, NC) to perform liver stiffness and echogenicity measurements in three dimensions. The instrument was validated with tissue-mimicking phantoms and a mouse model of nonalcoholic steatohepatitis. Female C57BL/6J mice (n = 40) were placed on choline-deficient, L-amino acid-defined, high-fat diet and imaged longitudinally for 15 weeks. A subset was sacrificed after each imaging timepoint (n = 5) for histological validation, and analyses of receiver operating characteristic (ROC) curves were performed. Results demonstrated that robotic measurements of echogenicity and stiffness were most strongly correlated with macrovesicular steatosis (R2  = 0.891) and fibrosis (R2  = 0.839), respectively. For diagnostic classification of fibrosis (Ishak score), areas under ROC (AUROCs) curves were 0.969 for ≥Ishak1, 0.984 for ≥Ishak2, 0.980 for ≥Ishak3, and 0.969 for ≥Ishak4. For classification of macrovesicular steatosis (S-score), AUROCs were 1.00 for ≥S2 and 0.997 for ≥S3. Average scanning and analysis time was <5 minutes/liver. Conclusion: Robotic SWE in small animals is feasible and sensitive to small changes in liver disease state, facilitating in vivo staging of rodent liver disease with minimal sonographic expertise.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Procedimentos Cirúrgicos Robóticos , Animais , Modelos Animais de Doenças , Técnicas de Imagem por Elasticidade/métodos , Feminino , Cirrose Hepática/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos C57BL , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Reprodutibilidade dos Testes
3.
Sci Rep ; 12(1): 102, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996939

RESUMO

Preclinical mouse solid tumor models are widely used to evaluate efficacy of novel cancer therapeutics. Recent reports have highlighted the need for utilizing orthotopic implantation to represent clinical disease more accurately, however the deep tissue location of these tumors makes longitudinal assessment challenging without the use of imaging techniques. The purpose of this study was to evaluate the performance of a new multi-modality high-throughput in vivo imaging system that combines bioluminescence imaging (BLI) with robotic, hands-free ultrasound (US) for evaluating orthotopic mouse models. Long utilized in cancer research as independent modalities, we hypothesized that the combination of BLI and US would offer complementary advantages of detection sensitivity and quantification accuracy, while mitigating individual technological weaknesses. Bioluminescent pancreatic tumor cells were injected into the pancreas tail of C57BL/6 mice and imaged weekly with the combination system and magnetic resonance imaging (MRI) to serve as a gold standard. BLI photon flux was quantified to assess tumor activity and distribution, and US and MRI datasets were manually segmented for gross tumor volume. Robotic US and MRI demonstrated a strong agreement (R2 = 0.94) for tumor volume measurement. BLI showed a weak overall agreement with MRI (R2 = 0.21), however, it offered the greatest sensitivity to detecting the presence of tumors. We conclude that combining BLI with robotic US offers an efficient screening tool for orthotopic tumor models.


Assuntos
Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética , Imagem Óptica , Neoplasias Pancreáticas/diagnóstico por imagem , Ultrassonografia , Animais , Linhagem Celular Tumoral , Progressão da Doença , Ensaios de Triagem em Larga Escala , Camundongos Endogâmicos C57BL , Imagem Multimodal , Neoplasias Pancreáticas/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Carga Tumoral
4.
J Vis Exp ; (174)2021 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-34459826

RESUMO

Common modalities for in vivo imaging of rodents include positron emission tomography (PET), computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound (US). Each method has limitations and advantages, including availability, ease of use, cost, size, and the use of ionizing radiation or magnetic fields. This protocol describes the use of 3D robotic US for in vivo imaging of rodent kidneys and heart, subsequent data analysis, and possible research applications. Practical applications of robotic US are the quantification of total kidney volume (TKV), as well as the measurement of cysts, tumors, and vasculature. Although the resolution is not as high as other modalities, robotic US allows for more practical high throughput data collection. Furthermore, using US M-mode imaging, cardiac function may be quantified. Since the kidneys receive 20%-25% of the cardiac output, assessing cardiac function is critical to the understanding of kidney physiology and pathophysiology.


Assuntos
Procedimentos Cirúrgicos Robóticos , Animais , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Camundongos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Ultrassonografia
5.
Kidney360 ; 1(10): 1126-1136, 2020 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-33521650

RESUMO

Polycystic kidney disease (PKD) is an inherited disorder characterized by renal cyst formation and enlargement of the kidney. PKD severity can be staged noninvasively by measuring total kidney volume (TKV), a promising biomarker that has recently received regulatory qualification. In preclinical mouse models, where the disease is studied and potential therapeutics are evaluated, the most popular noninvasive method of measuring TKV is magnetic resonance imaging (MRI). Although MRI provides excellent 3D resolution and contrast, these systems are expensive to operate, have long acquisition times, and, consequently, are not heavily used in preclinical PKD research. In this study, a new imaging instrument, based on robotic ultrasound (US), was evaluated as a complementary approach for assessing PKD in rodent models. The objective was to determine the extent to which TKV measurements on the robotic US scanner correlated with both in vivo and ex vivo reference standards (MRI and Vernier calipers, respectively). A cross-sectional study design was implemented that included both PKD-affected mice and healthy wild types, spanning sex and age for a wide range of kidney volumes. It was found that US-derived TKV measurements and kidney lengths were strongly associated with both in vivo MRI and ex vivo Vernier caliper measurements (R 2=0.94 and 0.90, respectively). In addition to measuring TKV, renal vascular density was assessed using acoustic angiography (AA), a novel contrast-enhanced US methodology. AA image intensity, indicative of volumetric vascularity, was seen to have a strong negative correlation with TKV (R 2=0.82), suggesting impaired renal vascular function in mice with larger kidneys. These studies demonstrate that robotic US can provide a rapid and accurate approach for noninvasively evaluating PKD in rodent models.


Assuntos
Doenças Renais Policísticas , Procedimentos Cirúrgicos Robóticos , Animais , Estudos Transversais , Imageamento por Ressonância Magnética/métodos , Camundongos , Doenças Renais Policísticas/diagnóstico por imagem , Roedores
6.
Ultrasound Med Biol ; 46(2): 369-376, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31694771

RESUMO

A cost-effective method for serial in vivo imaging of tumor microvasculature has been developed. We evaluated acoustic angiography (AA) for visualizing and assessing non-small cell lung tumor (A549) microvasculature in mice before and after tumor vascular disruption by vascular-targeted gold nanoparticles and radiotherapy. Standard B-mode and microbubble-enhanced AA images were acquired at pre- and post-treatment time points. Using these modes, a new metric, 50% vessel penetration depth, was developed to characterize the 3-D spatial heterogeneity of microvascular networks. We observed an increase in tumor perfusion after radiation-induced vascular disruption, relative to control animals. This was also visualized in vessel morphology mode, which revealed a loss in vessel integrity. We found that tumors with poorly perfused vasculature at day 0 exhibited a reduced growth rate over time. This suggested a new method to reduce in-group treatment response variability using pre-treatment microvessel maps to objectively identify animals for study removal.


Assuntos
Angiografia/métodos , Meios de Contraste , Imageamento Tridimensional , Nanopartículas Metálicas , Microbolhas , Microvasos/diagnóstico por imagem , Neoplasias/irrigação sanguínea , Neoplasias/diagnóstico por imagem , Animais , Feminino , Aumento da Imagem , Camundongos , Ultrassonografia/métodos
7.
IEEE Trans Biomed Eng ; 66(1): 72-79, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993406

RESUMO

OBJECTIVE: Ultrasound is an effective tool for rapid noninvasive assessment of cardiac structure and function. Determining the cardiorespiratory phases of each frame in the ultrasound video and capturing the cardiac function at a much higher temporal resolution are essential in many applications. Fulfilling these requirements is particularly challenging in preclinical studies involving small animals with high cardiorespiratory rates, requiring cumbersome and expensive specialized hardware. METHODS: We present a novel method for the retrospective estimation of cardiorespiratory phases directly from the ultrasound videos. It transforms the videos into a univariate time series preserving the evidence of periodic cardiorespiratory motion, decouples the signatures of cardiorespiratory motion with a trend extraction technique, and estimates the cardiorespiratory phases using a Hilbert transform approach. We also present a robust nonparametric regression technique for respiratory gating and a novel kernel-regression model for reconstructing images at any cardiac phase facilitating temporal superresolution. RESULTS: We validated our methods using two-dimensional echocardiography videos and electrocardiogram (ECG) recordings of six mice. Our cardiac phase estimation method provides accurate phase estimates with a mean-phase-error range of 3%-6% against ECG derived phase and outperforms three previously published methods in locating ECGs R-wave peak frames with a mean-frame-error range of 0.73-1.36. Our kernel-regression model accurately reconstructs images at any cardiac phase with a mean-normalized-correlation range of 0.81-0.85 over 50 leave-one-out-cross-validation rounds. CONCLUSION AND SIGNIFICANCE: Our methods can enable tracking of cardiorespiratory phases without additional hardware and reconstruction of respiration-free single cardiac-cycle videos at a much higher temporal resolution.


Assuntos
Ecocardiografia/métodos , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Animais , Coração/fisiologia , Camundongos , Gravação em Vídeo
8.
IEEE Trans Biomed Eng ; 66(3): 873-880, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30059292

RESUMO

BACKGROUND: Functional and molecular changes often precede gross anatomical changes, so early assessment of a tumor's functional and molecular response to therapy can help reduce a patient's exposure to the side effects of ineffective chemotherapeutics or other treatment strategies. OBJECTIVE: Our intent was to test the hypothesis that an ultrasound microvascular imaging approach might provide indications of response to therapy prior to assessment of tumor size. METHODS: Mice bearing clear-cell renal cell carcinoma xenograft tumors were treated with antiangiogenic and Notch inhibition therapies. An ultrasound measurement of microvascular density was used to serially track the tumor response to therapy. RESULTS: Data indicated that ultrasound-derived microvascular density can indicate response to therapy a week prior to changes in tumor volume and is strongly correlated with physiological characteristics of the tumors as measured by histology ([Formula: see text]). Furthermore, data demonstrated that ultrasound measurements of vascular density can determine response to therapy and classify between-treatment groups with high sensitivity and specificity. CONCLUSION/SIGNIFICANCE: Results suggests that future applications utilizing ultrasound imaging to monitor tumor response to therapy may be able to provide earlier insight into tumor behavior from metrics of microvascular density rather than anatomical tumor size measurements.


Assuntos
Inibidores da Angiogênese/farmacologia , Carcinoma de Células Renais , Neoplasias Renais , Microvasos , Ultrassonografia/métodos , Angiografia/métodos , Animais , Carcinoma de Células Renais/irrigação sanguínea , Carcinoma de Células Renais/diagnóstico por imagem , Monitoramento de Medicamentos , Feminino , Xenoenxertos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Neoplasias Renais/irrigação sanguínea , Neoplasias Renais/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Microvasos/diagnóstico por imagem , Microvasos/efeitos dos fármacos , Microvasos/patologia
10.
Rev Sci Instrum ; 89(7): 075107, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30068108

RESUMO

Noninvasive in vivo imaging technologies enable researchers and clinicians to detect the presence of disease and longitudinally study its progression. By revealing anatomical, functional, or molecular changes, imaging tools can provide a near real-time assessment of important biological events. At the preclinical research level, imaging plays an important role by allowing disease mechanisms and potential therapies to be evaluated noninvasively. Because functional and molecular changes often precede gross anatomical changes, there has been a significant amount of research exploring the ability of different imaging modalities to track these aspects of various diseases. Herein, we present a novel robotic preclinical contrast-enhanced ultrasound system and demonstrate its use in evaluating tumors in a rodent model. By leveraging recent advances in ultrasound, this system favorably compares with other modalities, as it can perform anatomical, functional, and molecular imaging and is cost-effective, portable, and high throughput, without using ionizing radiation. Furthermore, this system circumvents many of the limitations of conventional preclinical ultrasound systems, including a limited field-of-view, low throughput, and large user variability.


Assuntos
Imageamento Tridimensional/instrumentação , Roedores , Ultrassonografia/instrumentação , Animais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/fisiopatologia , Linhagem Celular Tumoral , Meios de Contraste , Progressão da Doença , Desenho de Equipamento , Feminino , Hemangiossarcoma/diagnóstico por imagem , Hemangiossarcoma/fisiopatologia , Humanos , Estudos Longitudinais , Microbolhas , Transplante de Neoplasias , Variações Dependentes do Observador , Projetos Piloto , Reprodutibilidade dos Testes , Robótica , Software
11.
Theranostics ; 8(1): 156-168, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29290799

RESUMO

Measuring changes in tumor volume using anatomical imaging weeks to months post radiation therapy (RT) is currently the clinical standard for indicating treatment response to RT. For patients whose tumors do not respond successfully to treatment, this approach is suboptimal as timely modification of the treatment approach may lead to better clinical outcomes. We propose to use tumor microvasculature as a biomarker for early assessment of tumor response to RT. Acoustic angiography is a novel contrast ultrasound imaging technique that enables high-resolution microvascular imaging and has been shown to detect changes in microvascular structure due to cancer growth. Data suggest that acoustic angiography can detect longitudinal changes in the tumor microvascular environment that correlate with RT response. Methods: Three cohorts of Fisher 344 rats were implanted with rat fibrosarcoma tumors and were treated with a single fraction of RT at three dose levels (15 Gy, 20 Gy, and 25 Gy) at a dose rate of 300 MU/min. A simple treatment condition was chosen for testing the feasibility of our imaging technique. All tumors were longitudinally imaged immediately prior to and after treatment and then every 3 days after treatment for a total of 30 days. Both acoustic angiography (using in-house produced microbubble contrast agents) and standard b-mode imaging was performed at each imaging time point using a pre-clinical Vevo770 scanner and a custom modified dual-frequency transducer. Results: Results show that all treated tumors in each dose group initially responded to treatment between days 3-15 as indicated by decreased tumor growth accompanied with decreased vascular density. Untreated tumors continued to increase in both volume and vascular density until they reached the maximum allowable size of 2 cm in diameter. Tumors that displayed complete control (no tumor recurrence) continued to decrease in size and vascular density, while tumors that progressed after the initial response presented an increase in tumor volume and volumetric vascular density. The increase in tumor volumetric vascular density in recurring tumors can be detected 10.25 ± 1.5 days, 6 ± 0 days, and 4 ± 1.4 days earlier than the measurable increase in tumor volume in the 15, 20, and 25 Gy dose groups, respectively. A dose-dependent growth rate for tumor recurrence was also observed. Conclusions: In this feasibility study we have demonstrated the ability of acoustic angiography to detect longitudinal changes in vascular density, which was shown to be a potential biomarker for tumor response to RT.


Assuntos
Fibrossarcoma/diagnóstico por imagem , Microbolhas , Microvasos/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Biomarcadores/análise , Feminino , Humanos , Ratos
12.
Artigo em Inglês | MEDLINE | ID: mdl-25570939

RESUMO

Recently, it has been demonstrated that through the use of contrast agents and multi-frequency transducer technology, high resolution and high signal to noise ultrasound images can be obtained which illustrate microvascular structure in unprecedented detail for an ultrasound modality. The enabling technology is ultrasound transducers which are fabricated with elements which can excite microbubble contrast agents near resonance and detect their broadband harmonics at a much higher bandwidth (several times the fundamental frequency). The resulting images contain very little background from tissue scattering and thus provide high contrast, and can have a resolution on the order of 130 microns with an appropriate high frequency receiving element. Because microbubbles are strictly an intravascular agent, this approach enables visualization of microvascular morphology with unique clarity, providing insight into angiogenesis associated with tumor development.


Assuntos
Fibrossarcoma/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Angiografia/métodos , Animais , Meios de Contraste , Fibrossarcoma/irrigação sanguínea , Humanos , Camundongos , Microbolhas , Ratos , Razão Sinal-Ruído , Transdutores , Ultrassonografia
13.
Biomaterials ; 34(37): 9341-51, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24011714

RESUMO

A method of 3D functional ultrasound imaging has been developed to enable non-destructive assessment of extracellular matrix scaffolds that have been prepared by decellularization protocols and are intended for recellularization to create organoids. A major challenge in organ decellularization is retaining patent micro-vascular structures crucial for nutrient access and functionality of organoids. The imaging method described here provides statistical distributions of flow rates throughout the tissue volumes, 3D vessel network architecture visualization, characterization of microvessel volumes and sizes, and delineation of matrix from vascular circuits. The imaging protocol was tested on matrix scaffolds that are tissue-specific, but not species-specific, matrix extracts, prepared by a process that preserved >98% of the collagens, collagen-associated matrix components, and matrix-bound growth factors and cytokines. Image-derived data are discussed with respect to assessment of scaffolds followed by proof-of-concept studies in organoid establishment using Hep3B, a human hepatoblast-like cell line. Histology showed that the cells attached to scaffolds with patent vasculature within minutes, achieved engraftment at near 100%, expressed liver-specific functions within 24 h, and yielded evidence of proliferation and increasing differentiation of cells throughout the two weeks of culture studies. This imaging method should prove valuable in analyses of such matrix scaffolds.


Assuntos
Matriz Extracelular/diagnóstico por imagem , Fígado/diagnóstico por imagem , Organoides/citologia , Alicerces Teciduais/química , Animais , Linhagem Celular , Matriz Extracelular/química , Matriz Extracelular/ultraestrutura , Humanos , Fígado/citologia , Fígado/ultraestrutura , Ratos , Ratos Wistar , Ultrassonografia
14.
Int J Biomed Imaging ; 2013: 936593, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23997762

RESUMO

The purpose of this paper is to provide the biomedical imaging community with details of a new high resolution contrast imaging approach referred to as "acoustic angiography." Through the use of dual-frequency ultrasound transducer technology, images acquired with this approach possess both high resolution and a high contrast-to-tissue ratio, which enables the visualization of microvascular architecture without significant contribution from background tissues. Additionally, volumetric vessel-tissue integration can be visualized by using b-mode overlays acquired with the same probe. We present a brief technical overview of how the images are acquired, followed by several examples of images of both healthy and diseased tissue volumes. 3D images from alternate modalities often used in preclinical imaging, contrast-enhanced micro-CT and photoacoustics, are also included to provide a perspective on how acoustic angiography has qualitatively similar capabilities to these other techniques. These preliminary images provide visually compelling evidence to suggest that acoustic angiography may serve as a powerful new tool in preclinical and future clinical imaging.

15.
Radiology ; 264(3): 733-40, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22771882

RESUMO

PURPOSE: To determine if the morphologies of microvessels could be extracted from contrast material-enhanced acoustic angiographic ultrasonographic (US) images and used as a quantitative basis for distinguishing healthy from diseased tissue. MATERIALS AND METHODS: All studies were institutional animal care and use committee approved. Three-dimensional contrast-enhanced acoustic angiographic images were acquired in both healthy (n = 7) and tumor-bearing (n = 10) rats. High-spatial-resolution and high signal-to-noise acquisition was enabled by using a prototype dual-frequency US transducer (transmit at 4 MHz, receive at 30 MHz). A segmentation algorithm was utilized to extract microvessel structure from image data, and the distance metric (DM) and the sum of angles metric (SOAM), designed to distinguish different types of tortuosity, were applied to image data. The vessel populations extracted from tumor-bearing tissue volumes were compared against vessels extracted from tissue volumes in the same anatomic location within healthy control animals by using the two-sided Student t test. RESULTS: Metrics of microvascular tortuosity were significantly higher in the tumor population. The average DM of the tumor population (1.34 ± 0.40 [standard deviation]) was 23.76% higher than that of the control population (1.08 ± 0.08) (P < .0001), while the average SOAM (22.53 ± 7.82) was 50.73% higher than that of the control population (14.95 ± 4.83) (P < .0001). The DM and SOAM metrics for the control and tumor populations were significantly different when all vessels were pooled between the two animal populations. In addition, each animal in the tumor population had significantly different DM and SOAM metrics relative to the control population (P < .05 for all; P value ranges for DM, 3.89 × 10(-)(7) to 5.63 × 10(-)(3); and those for SOAM, 2.42 × 10(-)(12) to 1.57 × 10(-)(3)). CONCLUSION: Vascular network quantification by using high-spatial-resolution acoustic angiographic images is feasible. Data suggest that the angiogenic processes associated with tumor development in the models studied result in higher instances of vessel tortuosity near the tumor site.


Assuntos
Fibrossarcoma/diagnóstico por imagem , Imageamento Tridimensional/métodos , Microcirculação , Neovascularização Patológica/diagnóstico por imagem , Animais , Meios de Contraste , Modelos Animais de Doenças , Feminino , Processamento de Imagem Assistida por Computador , Microbolhas , Estudos Prospectivos , Ratos , Ratos Endogâmicos F344 , Transdutores , Ultrassonografia
16.
Ultrasound Med Biol ; 38(4): 651-60, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22341052

RESUMO

For more than a decade, the application of acoustic radiation force (ARF) has been proposed as a mechanism to increase ultrasonic molecular imaging (MI) sensitivity in vivo. Presented herein is the first noninvasive in vivo validation of ARF-enhanced MI with an unmodified clinical system. First, an in vitro optical-acoustical setup was used to optimize system parameters and ensure sufficient microbubble translation when exposed to ARF. 3-D ARF-enhanced MI was then performed on 7 rat fibrosarcoma tumors using microbubbles targeted to α(v)ß3 and nontargeted microbubbles. Low-amplitude (<25 kPa) 3-D ARF pulse sequences were tested and compared with passive targeting studies in the same animal. Our results demonstrate that a 78% increase in image intensity from targeted microbubbles can be achieved when using ARF relative to the passive targeting studies. Furthermore, ARF did not significantly increase image contrast when applied to nontargeted agents, suggesting that ARF did not increase nonspecific adhesion.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fibrossarcoma/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imagem Molecular/métodos , Animais , Meios de Contraste/administração & dosagem , Meios de Contraste/síntese química , Desenho de Equipamento , Fibrossarcoma/patologia , Microbolhas , Ratos Endogâmicos F344 , Sensibilidade e Especificidade , Transdutores
17.
Reprod Biol Endocrinol ; 10: 7, 2012 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-22289508

RESUMO

BACKGROUND: Studies published in the 1970s by Mostafa S. Fahim and colleagues showed that a short treatment with ultrasound caused the depletion of germ cells and infertility. The goal of the current study was to determine if a commercially available therapeutic ultrasound generator and transducer could be used as the basis for a male contraceptive. METHODS: Sprague-Dawley rats were anesthetized and their testes were treated with 1 MHz or 3 MHz ultrasound while varying power, duration and temperature of treatment. RESULTS: We found that 3 MHz ultrasound delivered with 2.2 Watt per square cm power for fifteen minutes was necessary to deplete spermatocytes and spermatids from the testis and that this treatment significantly reduced epididymal sperm reserves. 3 MHz ultrasound treatment reduced total epididymal sperm count 10-fold lower than the wet-heat control and decreased motile sperm counts 1,000-fold lower than wet-heat alone. The current treatment regimen provided nominally more energy to the treatment chamber than Fahim's originally reported conditions of 1 MHz ultrasound delivered at 1 Watt per square cm for ten minutes. However, the true spatial average intensity, effective radiating area and power output of the transducers used by Fahim were not reported, making a direct comparison impossible. We found that germ cell depletion was most uniform and effective when we rotated the therapeutic transducer to mitigate non-uniformity of the beam field. The lowest sperm count was achieved when the coupling medium (3% saline) was held at 37 degrees C and two consecutive 15-minute treatments of 3 MHz ultrasound at 2.2 Watt per square cm were separated by 2 days. CONCLUSIONS: The non-invasive nature of ultrasound and its efficacy in reducing sperm count make therapeutic ultrasound a promising candidate for a male contraceptive. However, further studies must be conducted to confirm its efficacy in providing a contraceptive effect, to test the result of repeated use, to verify that the contraceptive effect is reversible and to demonstrate that there are no detrimental, long-term effects from using ultrasound as a method of male contraception.


Assuntos
Anticoncepção/métodos , Epididimo/citologia , Contagem de Espermatozoides , Testículo/citologia , Terapia por Ultrassom/métodos , Animais , Temperatura Alta , Masculino , Meiose , Ratos , Ratos Sprague-Dawley , Terapia por Ultrassom/instrumentação
18.
Ultrasound Med Biol ; 38(1): 168-72, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22104535

RESUMO

Acoustic radiation force has been proposed as a mechanism to enhance microbubble concentration for therapeutic and molecular imaging applications. It is hypothesized that once microbubbles are localized, bursting them with acoustic pressure could result in local drug delivery. It is known that low-frequency, high-amplitude acoustic energy combined with cavitation nuclei can result in bioeffects. However, little is known about the bioeffects potential of acoustic parameters involved in radiation force and microbubble destruction pulse sequences applied at higher frequencies. In this pilot study, rat kidneys are exposed to high-duty cycle, low-amplitude pulse sequences known to cause substantial bubble translation due to radiation force, as well as high-amplitude short pulse sequences known to cause microbubble destruction. Both studies are performed at 7 MHz on a clinical ultrasound system, and implemented in three-dimensions (3-D) for entire kidney exposure. Analysis of biomarkers of renal injury and renal histopathology indicate that there was no significant renal damage due to these ultrasound parameters in conjunction with microbubbles within the study group.


Assuntos
Injúria Renal Aguda/etiologia , Injúria Renal Aguda/fisiopatologia , Meios de Contraste/efeitos adversos , Ondas de Choque de Alta Energia/efeitos adversos , Rim/lesões , Rim/fisiopatologia , Rim/efeitos da radiação , Animais , Masculino , Microbolhas , Projetos Piloto , Ratos , Ratos Sprague-Dawley
19.
Mol Imaging ; 10(6): 460-8, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22201537

RESUMO

Molecular imaging (MI) with ultrasonography relies on microbubble contrast agents (MCAs) adhering to a ligand-specific target for applications such as characterizing tumor angiogenesis. It is projected that ultrasonic (US) MI can provide information about tumor therapeutic response before the detection of phenotypic changes. One of the limitations of preclinical US MI is that it lacks a comprehensive field of view. We attempted to improve targeted MCA visualization and quantification by performing three-dimensional (3D) MI of tumors expressing αvß3 integrin. Volumetric acquisitions were obtained with a Siemens Sequoia system in cadence pulse sequencing mode by mechanically stepping the transducer elevationally across the tumor in 800-micron increments. MI was performed on rat fibrosarcoma tumors (n  =  8) of similar sizes using MCAs conjugated with a cyclic RGD peptide targeted to αvß3 integrin. US MI and immunohistochemical analyses show high microbubble targeting variability, suggesting that individual two-dimensional (2D) acquisitions risk misrepresenting more complex heterogeneous tissues. In 2D serial studies, where it may be challenging to image the same plane repeatedly, misalignments as small as 800 microns can introduce substantial error. 3D MI, including volumetric analysis of inter- and intra-animal targeting, provides a thorough way of characterizing angiogenesis and will be a more robust assessment technique for the future of MI.


Assuntos
Fibrossarcoma/irrigação sanguínea , Fibrossarcoma/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem Molecular/métodos , Neovascularização Patológica/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Meios de Contraste , Imuno-Histoquímica , Integrina alfaVbeta3/análise , Integrina alfaVbeta3/biossíntese , Microbolhas , Neoplasias Experimentais/diagnóstico por imagem , Neovascularização Patológica/patologia , Oligopeptídeos/química , Ratos
20.
Ultrasound Med Biol ; 37(5): 827-33, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21439718

RESUMO

Ultrasound techniques are currently being developed that can assess the vascularization of tissue as a marker for therapeutic response. Some of these ultrasound imaging techniques seek to extract quantitative features about vessel networks, whereas high-frequency imaging also allows individual vessels to be resolved. The development of these new techniques, and subsequent imaging analysis strategies, necessitates an understanding of their sensitivities to vessel and vessel network structural abnormalities. Constructing in-vitro flow phantoms for this purpose can be prohibitively challenging, because simulating precise flow environments with nontrivial structures is often impossible using conventional methods of construction for flow phantoms. Presented in this manuscript is a method to create predefined structures with <10 µm precision using a three-axis motion system. The application of this technique is demonstrated for the creation of individual vessel and vessel networks, which can easily be made to simulate the development of structural abnormalities typical of diseased vasculature in vivo. In addition, beyond facilitating the creation of phantoms that would otherwise be very challenging to construct, the method presented herein enables one to precisely simulate very slow blood flow and respiration artifacts, and to measure imaging resolution.


Assuntos
Microvasos , Ultrassonografia , Artefatos , Materiais Biomiméticos , Meios de Contraste , Humanos , Aumento da Imagem , Imageamento Tridimensional , Microvasos/diagnóstico por imagem , Movimento (Física) , Sensibilidade e Especificidade , Ultrassonografia/instrumentação , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA