Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Herz ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743296

RESUMO

BACKGROUND: Percutaneous valve therapies (PVT) are performed on a large number of patients. With increasing procedural volume, the need for follow-up has also increased. Follow-up in the heart valve clinic is endorsed by recent guidelines but utilization is unknown, making resource allocation in the clinic difficult. Central follow-up in valve centers may not be feasible for all patients in the future. METHODS: In our center, follow-up for PVT patients is scheduled at 1 month and 12 months after the index procedure. Patients are reminded of their appointment by invitation letters or phone calls. We analyzed 150 consecutive patients who underwent transcutaneous aortic valve implantation (TAVI) and MitraClip implantation (n = 300) at our center. RESULTS: At 1 month, 72.7% of patients attended their follow-up, while at 12 months the rate dropped to 58%. Patients who underwent TAVI were older than the MitraClip patients (82.7 vs. 76.1 years) but had lower mean logEuroSCORE (22.6% vs. 25.9%). There was no significant difference in 1­year mortality between TAVI and MitraClip patients (20% vs. 17.3%). By contrast, the rate of missed follow-up visits was higher for TAVI compared to MitraClip patients (52% vs. 33.3%; p = 0.002). Female patients less frequently attended follow-up (p = 0.005), whereas age, EuroSCORE, NYHA class, ejection fraction, and health status (EQ-5DVAS) were not predictors of attendance in multivariable analysis. Although the result of the EQ-5D assessment was not associated with mortality or attendance, completing the questionnaire was associated with overall survival (p < 0.001). CONCLUSION: In our heart valve clinic, we observed a high percentage of missed follow-up appointments (42% at 12 months) despite a structured follow-up plan. Factors significantly associated with non-attendance in multivariable analysis were female gender and having a TAVI rather than MitraClip. Future follow-up concepts should take such findings into account, and decentralized approaches need to be explored.

2.
Front Cardiovasc Med ; 11: 1223588, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468721

RESUMO

Background: There are different types of transcatheter mitral valve repair (TMVr) currently in clinical use, including leaflet approximation, annular cinching, and restoration of the chordal apparatus of the mitral valve (MV). While the concomitant combination (COMBO) therapy of mitral transcatheter edge-to-edge repair (M-TEER) with another TMVr concept has been proven feasible, potentially offering patient-tailored treatment for severe mitral regurgitation (MR), a comparison with M-TEER alone has not been made. Aims: To evaluate the procedural and clinical outcome of COMBO therapies compared with M-TEER alone. Methods: We included consecutive patients undergoing COMBO and M-TEER between March 2015 and April 2018 at our Heart Valve Center, while excluding patients presenting a case of redo or with previous MV surgery. Procedural outcomes and all-cause mortality were compared between COMBO therapy vs. M-TEER alone. Results: A total of 357 patients (mean age 78.9 ± 7.0 years, 53.2% male, M-TEER n = 322, COMBO n = 35; COMBO: MitraClip and the Carillon mitral contour system n = 26, MitraClip and Cardioband n = 5, and MitraClip and NeoChord n = 4) were analyzed. Patients with COMBO therapy had larger left chamber sizes, a lower left ventricular systolic ejection fraction (LVEF; COMBO: 37.4 ± 13.8%, M-TEER: 47.9 ± 14.3%, p < 0.001), and a more severe MR grade (p < 0.001). There were no significant differences in the prevalence of residual MR ≧2+. However, the need for re-intervention, always employing M-TEER, was more common in the COMBO group. During a mean 3.6-year long-term follow-up, there was no significant difference of all-cause mortality between both groups (Log rank p = 0.921). Conclusions: COMBO therapy may still be a beneficial therapy option for patients with severe MR who already have a more dilated left ventricle (LV), a more severe MR, and a more pronounced LV systolic dysfunction. The higher need for re-intervention in the COMBO group may signal more complex anatomies and possibly underlines the necessity of treating significant MR earlier. Future research is required to establish the COMBO approach as a toolbox-like treatment option, thus offering a patient-tailored approach depending on the individual anatomy and pathology.

3.
Echocardiography ; 41(1): e15700, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37788169

RESUMO

Minimalist approaches have evolved for TAVR over the last years with impact on in-hospital stay and patient safety. As part of this concept, transradial secondary arterial access is capable of reducing vascular and bleeding complications. Yet, steering of the marker pigtail catheter in the descending aorta might by fluoroscopic imaging sometimes be challenging. In our manuscript, we present a very simple "piggyback" technique, simplifying management of transradial secondary access in transfemoral TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Fatores de Risco , Valva Aórtica/cirurgia
4.
J Thorac Imaging ; 39(2): 127-135, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982533

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Feminino , Masculino , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração , Função Ventricular Esquerda
6.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648344

RESUMO

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
7.
Front Cardiovasc Med ; 10: 1181771, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37435055

RESUMO

Background: Transcatheter aortic valve implantation (TAVI) is a standard treatment for patients with aortic valve stenosis due to its very low mortality and complication rates. However, survival and physical integrity are not the only important factors. Quality of life (QoL) improvement is a crucial part in the evaluation of therapy success. Methods: Patients with TAVI were questioned about their QoL before, one month and one year after the intervention as part of the INTERVENT registry trial at Mainz University Medical Center. Three different questionnaires were included in the data collection (Katz ADL, EQ-5D-5l, PHQ-D). Results: We included 285 TAVI patients in the analysis (mean age 79.8 years, 59.4% male, mean EuroSCORE II 3.8%). 30-day mortality was 3.6%, complications of any kind occurred in 18.9% of the patients. Main finding was a significant increase in the general state of health measured on the visual analog scale by an average of 4.53 (± 23.58) points (BL to 1-month follow-up, p = 0.009) and by 5.19 (± 23.64) points (BL to 12-month follow-up, p = 0.016). There was also an improvement of depression symptoms, which was reflected in a decrease in the total value of the PHQ-D by 1.67 (± 4.75) points (BL to 12-month follow-up, p = 0.001). The evaluation of the EQ-5D-5l showed a significant improvement in mobility after one month (M = -0.41 (± 1.31), p < 0.001. Regarding the independence of the patients, no significant difference could be found. Apart from that, patients with risk factors, comorbidities or complications also benefited from the intervention despite their poor starting position. Conclusion: We could show an early benefit of QoL in TAVI patients with significant improvement in the subjective state of health and a decrease in symptoms of depression. These findings were consistent over 1 year of follow up.

8.
Front Cardiovasc Med ; 10: 1029103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36873404

RESUMO

Aims: For patients with severe mitral valve regurgitation (MR), different kinds of transcatheter mitral valve repair (TMVr) exist, targeting the leaflets, annulus, and chordae. The concomitant combination (COMBO) therapy of TMVrs is rarely used as treatment, and there are very few publications about this therapeutic strategy. We evaluated the effect of COMBO-TMVr on the cardiac left chambers and clinical data, including survival. Methods: We included 35 patients at high risk who underwent concomitant sequential transcatheter mitral valve edge-to-edge repair (M-TEER) and another TMVr for severe MR in our hospital between March 2015 and April 2018. Of these, 13 had adequate follow-up transthoracic echocardiography (TTE) up to around 1 year after the procedure. Results: Survival for all patients was 83% at 1 year, 71% at 2 years, and 63% at 3 years, respectively. In the 13 patients with adequate TTE follow-up, M-TEER plus either Cardioband (n = 4), Carillon Mitral Contour System (n = 7), or Neochord (n = 2) were used, respectively. Ten patients had secondary, and three patients primary MR. After 1 year, changes [median (Q1, Q3)] of left ventricular (LV) end-systolic diameter of -9.9 cm (-11.1, 0.4), LV end-diastolic diameter of -3.3 cm (-8.5, 0.0), LV end-systolic volume (LVESV) of -17.4 mL (-32.6, -0.4), LV end-diastolic volume (LVEDV) of -13.5 mL (-15.9, -3.2), LV mass of -19.5 g (-24.2, -7.6), and left atrial volume (LAV) index (LAVi) of -16.4 mL (-23.3, -11.3) were observed. A significant reduction was also seen in the change ratios of LVESV, LVEDV, LV mass, and LAVi, respectively. Conclusion: We found that COMBO therapy of TMVr seems feasible and may support reverse remodeling of left cardiac chambers during 1 year after the procedure in a cohort of patients at high risk.

10.
Sensors (Basel) ; 23(3)2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36772778

RESUMO

Apples are stored at temperatures close to 0 °C and high relative humidity (up to 95%) under controlled atmosphere conditions. Under these conditions, the cyclic operation of the refrigeration machine and the associated temperature fluctuations can lead to localized undershoots of the dew point on fruit surfaces. The primary question for the present study was to prove that such condensation processes can be measured under practical conditions during apple storage. Using the example of a measuring point in the upper apple layer of a large bin in the supply air area, this evidence was provided. Using two independent measuring methods, a wetness sensor attached to the apple surface and determination of climatic conditions near the fruit, the phases of condensation, namely active condensation and evaporation, were measured over three weeks as a function of the operating time of the cooling system components (refrigeration machine, fans, defrosting regime). The system for measurement and continuous data acquisition in the case of an airtight CA-storage room is presented and the influence of the operation of the cooling system components in relation to condensation phenomena was evaluated. Depending on the set point specifications for ventilation and defrost control, condensed water was present on the apple surface between 33.4% and 100% of the duration of the varying cooling/re-warming cycles.

12.
JACC Case Rep ; 28: 102116, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204548

RESUMO

Recently, a novel transfemoral self-expandable valve (JenaValve Trilogy) was granted a CE mark as a dedicated device for transfemoral treatment of both aortic valve stenosis and regurgitation. Here, we highlight the importance of 3-dimensional preprocedural planning for the optimal choice of a prosthesis in challenging anatomies by reporting an unusual case of a heavily calcified aortic sinus.

13.
Clin Cardiol ; 45(12): 1236-1245, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36070481

RESUMO

BACKGROUND: The number of MitraClip® implantations increased significantly in recent years. Data regarding the impact of weight class on survival are sparse. HYPOTHESIS: We hypothesized that weight class influences survival of patients treated with MitraClip® implantation. METHODS: We investigated in-hospital, 1-year, 3-year, and long-term survival of patients successfully treated with isolated MitraClip® implantation for mitral valve regurgitation (MR) (June 2010-March 2018). Patients were categorized by weight classes, and the impact of weight classes on survival was analyzed. RESULTS: Of 617 patients (aged 79.2 years; 47.3% females) treated with MitraClip® implantation (June 2010-March 2018), 12 patients were underweight (2.2%), 220 normal weight (40.1%), 237 overweight (43.2%), and 64 obesity class I (11.7%), 12 class II (2.2%), and 4 class III (0.7%). Preprocedural Logistic EuroScore (21.1 points [IQR 14.0-37.1]; 26.0 [18.5-38.5]; 26.0 [18.4-39.9]; 24.8 [16.8-33.8]; 33.0 [25.9-49.2]; 31.6 [13.1-47.6]; p = .291) was comparable between groups. Weight class had no impact on in-hospital death (0.0%; 4.1%; 1.5%; 0.0%; 7.7%; 0.0%; p = .189), 1-year survival (75.0%; 72.0%; 76.9%; 75.0%; 75.0%; 33.3%; p = .542), and 3-year survival (40.0%; 36.8%; 38.2%; 48.6%; 20.0%; 33.3%; p = .661). Compared to normal weight, underweight (hazard ratio [HR]: 1.35 [95% confidence interval [CI]: 0.65-2.79], p = .419), obesity-class I (HR: 0.93 [95% CI: 0.65-1.34], p = .705), class II (HR: 0.39 [95% CI: 0.12-1.24], p = .112), and class III (HR: 1.28 [95% CI: 0.32-5.21], p = .726) did not affect long-term survival. In contrast, overweight was associated with better survival (HR: 1.32 [95% CI: 1.04-1.68], p = .023). CONCLUSION: Overweight affected the long-term survival of patients undergoing MitraClip® implantation beneficially compared to normal weight.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Magreza/complicações , Mortalidade Hospitalar , Sobrepeso/complicações , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Obesidade/complicações , Cateterismo Cardíaco/efeitos adversos
14.
Eur J Heart Fail ; 24(11): 2162-2171, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36054557

RESUMO

AIMS: Right ventricular dysfunction (RVD), as expressed by right ventricular to pulmonary artery coupling, has recently been identified as a strong outcome predictor in patients undergoing mitral valve edge-to-edge repair (M-TEER) for secondary mitral regurgitation (MR). The aim of this study was to define RVD in patients undergoing M-TEER for primary MR (PMR) and to evaluate its impact on procedural MR reduction, symptomatic development and 2-year all-cause mortality. METHODS AND RESULTS: This multicentre study included patients undergoing M-TEER for symptomatic PMR at nine international centres. The study cohort was divided into a derivation (DC) and validation cohort (VC) for calculation and validation of the best discriminatory value for RVD. A total of 648 PMR patients were included in the study. DC and VC were comparable regarding procedural success and outcomes at follow-up. Sensitivity analysis identified RVD as an independent predictor for 2-year mortality in the DC (hazard ratio [HR] 2.37, 95% confidence interval [CI] 1.47-3.81, p < 0.001), which was confirmed in the VC (HR 2.06, 95% CI 1.36-3.13, p < 0.001). Procedural success (MR ≤2+) and symptomatic improvement at follow-up (New York Heart Association [NYHA] class ≤II) were lower in PMR patients with RVD (MR ≤2+: 82% vs. 93%, p = 0.002; NYHA class ≤II: 57.3% vs. 66.5%, p = 0.09 for with vs. without RVD). In all PMR patients, the presence of RVD significantly impaired 2-year survival after M-TEER (HR 2.23, 95% CI 1.63-3.05, p < 0.001). CONCLUSIONS: Mitral valve edge-to-edge repair is an effective treatment option for PMR patients. The presence of RVD is associated with less MR reduction, less symptomatic improvement and increased 2-year mortality. Accordingly, RVD might be included into pre-procedural prognostic considerations.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Humanos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia
15.
Front Cardiovasc Med ; 9: 922366, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35990972

RESUMO

Aim: The aim of this study is to provide evidence on how use of standardized intravascular ultrasound (IVUS) use impacts stent size choice in the setting of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) compared to visual estimation. Methods and results: Data of 82 consecutive patients who had successfully undergone IVUS-guided revascularization of CTO at the University Medical Center Mainz were analyzed. Angiography-based stent size prediction for the proximal and distal vessels was compared to the implanted stent diameter after IVUS assessment. Angiography-based stent size prediction for the proximal vessel was 3.09 ± 0.41, whereas IVUS use demonstrated larger vessel diameter, resulting in larger implanted stent diameter (3.24 ± 0.45, p < 0.001). Proximal vessel stent size prediction was underestimated in the majority of patients by angiographic estimation. Angiography-based stent size prediction for the distal vessel was 2.79 ± 0.38, whereas IVUS use demonstrated larger vessel diameter, resulting in larger implanted stent diameter (2.92 ± 0.39, p < 0.001). Conclusion: Pre-stent IVUS assessment in CTO PCI provides important information on vessel morphology and size. Angiography-based stent size prediction for the proximal and distal vessels was frequently underestimated, IVUS use demonstrated larger vessel diameter, resulting in significantly larger implanted stent diameter.

16.
J Cardiovasc Med (Hagerstown) ; 23(7): 477-478, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35763770

RESUMO

Anomalies of the coronary ostia are a potential challenge to the interventionalist. Commissural alignment has recently been introduced as concept for transcatheter aortic valve replacement (TAVR) to avoid potential coronary obstruction and to facilitate future coronary re-access. Here, we report a case of TAVR in a patient with a rare anomaly of the left coronary artery (LCA)-ostium, originating from the commissure between left- and noncoronary sinus, illustrating a potential pitfall for contemporary TAVR-implantation protocols and discuss the final choice of prosthesis suiting the demands of this distinct anatomical variance.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos
18.
Sci Rep ; 12(1): 3073, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35197506

RESUMO

Feasibility and efficacy of complex percutaneous coronary intervention (PCI) in the elderly, a more frail population due to more comorbidities is incompletely understood. We therefore set out to compare success and complication rate of PCI for chronic total occlusion (CTO) in octogenarians, in comparison to non-octogenarians. Data from 267 patients (58 patients over 80 years of age and 209 under 80 years of age) who had undergone CTO PCI were analyzed. To compare the results we calculated the propensity score and used inverse probability of treatment weighting. We evaluated demographic, clinical, angiographic, and periprocedural information. The median age of the total collective was 68 (31-90) years (octogenarian collective 82 (80-90) years vs non-octogenarians 65 (31-79) years). We observed a high success rate in both collectives (82.8% vs 90.4%, p = 0.10) and no difference in periprocedural complications or complications in the follow-up period. In our collective restenosis rate at follow-up was comparable to the propensity sore weighted population (11.3% vs 16.3%, p = 0.9). Our results show that CTO PCI in older patients is safe and feasible with comparable in-hospital and follow-up complication rates compared to a younger patient population.


Assuntos
Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/epidemiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Octogenários , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/etiologia , Pontuação de Propensão , Resultado do Tratamento
20.
Foods ; 10(12)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34945516

RESUMO

Adjusting beneficial gas concentrations in real time in response to changing storage conditions is important for fresh produce, especially throughout the supply chain when temperature abuse occurs frequently. In this study, a controlled-ventilated box for bulk transportation of fresh produce was demonstrated and tested under variable temperatures. The presented system comprised a rigid container with a miniature blower installed in the opening of its wall for facilitating the gas exchange and an additional wall opening with a metal tube protruding into the inner container's space. The in-package atmosphere was formed by the balance between the respiratory activity of the produce and the influx of fresh air through the wall openings, regulated by switching the blower ON or OFF. The mass transfer coefficient for metal tubes of different dimensions was measured under modified atmosphere featuring 15% CO2 and 5% O2 at 10 °C. The addition of an air blower increased the mass transfer coefficient by at least 100 times. A further storage trial with cherries was successfully performed at 10 °C and 20 °C. The demonstrated trial featured some significant inputs to increase the knowledge about better storage of fresh produce throughout the supply chain and storage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA