Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
JACC Adv ; 3(7): 100976, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39130041
2.
Heart Rhythm ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39117003

RESUMO

BACKGROUND: Recurrence during the 3-month blanking period following radiofrequency ablation of atrial fibrillation (AF) is typically not considered as a predictor for late recurrence. OBJECTIVE: We investigated the significance of early recurrence as a risk factor for late recurrence in AF patients receiving pulsed-field ablation (PFA). METHODS: Consecutive patients undergoing PFA were prospectively followed-up for 1 year. All patients received isolation of pulmonary veins. Additional ablations were performed per operator's discretion. Following the procedure all remained on their previously ineffective antiarrhythmic drugs (AAD) during the 2-month blanking period after which the AADs were discontinued. Early recurrence was defined as atrial arrhythmia of > 30 second duration during the 3-mo blanking period and any recurrence beyond 3-mo was considered as late recurrence. RESULTS: A total of 337 patients undergoing PFA for AF were included. Early recurrence was recorded in 53 (15.7%) patients; 10 in the 1st month, 12 in the 2nd month and 31 in the 3rd month. Of the 10 patients having recurrence during the 1st month, 7 (70%) remained in sinus rhythm after cardioversion whereas 3 (30%) underwent redo because of late-recurrence. At 1 year, all patients with recurrence during the 2nd and 3rd month, experienced late-recurrence of which 10/12 and 27/31 underwent redo and the remaining 6 patients were in sinus on-AAD. CONCLUSION: In this consecutive series of AF patients, early-recurrence in the 2nd or 3rd month following the PFA procedure was associated with high risk of late-recurrence. Thus, blanking period could be redefined as 1-month following PFA.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38878012

RESUMO

BACKGROUND: Purkinje fibers play an important role in initiation and maintenance of ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT). Fascicular substrate modification (FSM) approaches have been suggested to treat recurrent VF in case reports and small case series. OBJECTIVES: The aim of this study was to investigate outcomes of catheter-based FSM to treat VF and PMVT. METHODS: Of 2,212 consecutive patients with ventricular arrhythmia undergoing catheter ablation, 18 (0.81%) underwent FSM of the Purkinje fibers as identified with high-density mapping during sinus rhythm. Fascicular substrate and VF initiation were mapped using a multipolar catheter. The endpoint of the ablation was noninducibility of VF and PMVT. In select patients, remapping revealed elimination of the targeted Purkinje potentials. Demographic, clinical, and follow-up characteristics were prospectively collected in our institutional database. RESULTS: A total of 18 patients (mean age 56 ± 3.8 years, 22% women) were included in the study. Of those, 11 (61.1%) had idiopathic VF, 3 (16.7%) had nonischemic cardiomyopathy, and 4 (22.2%) had mixed cardiomyopathy. The average left ventricular ejection fraction was 42.5%. At least 2 antiarrhythmic drugs had failed preablation. At baseline, all patients had inducible VF or PMVT. At the end of the procedure, no patient demonstrated new evidence of fascicular block or bundle branch block. There were no procedure-related complications. After a median follow-up period of 24 months, 16 patients (88.9%) were arrhythmia free on or off drugs: 11 of 11 patients (100%) with idiopathic VF vs 5 of 7 patients (71.4%) with underlying cardiomyopathy (P = 0.06). CONCLUSIONS: Catheter ablation of human VF and PMVT with FSM is feasible and safe and appears highly effective, with high rates of acute VF noninducibility and long-term freedom from recurrent VF.

6.
J Cardiovasc Electrophysiol ; 35(7): 1422-1428, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38751010

RESUMO

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.


Assuntos
Amiloidose , Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Ablação por Cateter/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fatores de Risco , Fatores de Tempo , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/diagnóstico por imagem , Hemorragia/induzido quimicamente , Administração Oral , Estudos Retrospectivos , Medição de Risco , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Esquema de Medicação , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
7.
Card Electrophysiol Clin ; 16(2): 181-186, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749639

RESUMO

A 70-year-old man with recurrent atrial fibrillation (AF) underwent transcatheter radiofrequency ablation after an earlier unsuccessful attempt. Although typical AF triggers were ablated, the patient's condition persisted, leading to the identification of the interatrial septum (IAS) as the probable source of the tachycardia trigger. Given the depth and thickness of the IAS, traditional radiofrequency ablation proved ineffective. However, using the alternative method of bipolar radiofrequency catheter ablation (B-RFCA), the atrial tachycardia was successfully terminated. B-RFCA demonstrates potential for effectively terminating tachycardias originating from deep intramural locations, suggesting its potential as a pivotal technique for complex cases with septal atrial tachycardia.


Assuntos
Ablação por Cateter , Humanos , Masculino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Septo Interatrial/cirurgia , Septo Interatrial/diagnóstico por imagem
9.
J Arrhythm ; 40(2): 382-384, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586852

RESUMO

Background: The impact of chronic kidney disease (CKD) on atrial fibrillation outcomes (AF) is not well understood. Methods: We conducted analyses of comorbid AF and CKD related death in the United States from 1999 to 2020 using descriptive epidemiology. Results: Age-adjusted mortality rates (AAMR) per 100,000 increased from 0.39 in 1999 to 1.65 in 2020. Non-Hispanic populations (1.01) and nonmetropolitan areas (1.08) had higher AAMRs compared to Hispanic (0.62) and metropolitan (0.97) areas. Midwestern (1.11) and Western (1.13) US regions recorded the highest AAMRs. Conclusions: These findings highlight the need for interventions to address AF death disparities in patients with CKD.

10.
JACC Case Rep ; 29(5): 102227, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38464799

RESUMO

We present a case of persistent complete atrioventricular block that occurred during the diagnostic portion of a premature ventricular contractions' radiofrequency ablation in a complex heart failure patient. The case was managed by bailout deep left ventricular septal pacing after bipolar radiofrequency elimination of premature ventricular contractions.

11.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
12.
Heart Rhythm ; 21(8): 1267-1276, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38246567

RESUMO

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Pontuação de Propensão , Humanos , Masculino , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Apêndice Atrial/cirurgia , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Administração Oral , Medição de Risco/métodos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Fatores de Risco , Seguimentos , Estudos Prospectivos , Incidência , Resultado do Tratamento , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/epidemiologia , Idoso de 80 Anos ou mais
15.
JACC Clin Electrophysiol ; 10(3): 477-486, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38069973

RESUMO

BACKGROUND: Studies have reported development of pulmonary hypertension (PH) secondary to reduced LA compliance following AF ablation. OBJECTIVES: This study aimed to compare the risk of worsening of baseline PH between non-paroxysmal AF patients undergoing pulsed-field ablation (PFA) and standard radiofrequency ablation (RFA). METHODS: This multicenter study included 28 nonparoxysmal AF patients with PH undergoing a PFA-based ablation procedure after >1 failed RFA. A cohort of 28 AF patients with PH, scheduled for repeat RFA, 1:1 propensity-score matched using a multivariable logistic model, were used as the comparator group. Right heart catheterization and echocardiography were performed before and after the procedure to assess the pulmonary artery pressure (PAP). PH was defined as resting mean PAP of >20 mm Hg. RESULTS: The baseline characteristics of the PFA and propensity-matched RFA groups were comparable. The mean PAP assessments at baseline, follow-up, and change from baseline were analyzed. The groups had comparable baseline mean pulmonary artery pressures (mPAP) (P = 0.177). After adjustment for baseline mPAP in an analysis of covariance model, the least-squares means change at 3 months after ablation was -1.71 ± 1.03 mm Hg and 19.67 ± 1.03 mm Hg in PFA and RFA, respectively (P <0.001). CONCLUSIONS: In this propensity-matched population, no worsening of mPAP was detected following pulsed-field ablation in patients with pre-existing PH undergoing a repeat procedure for recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Hipertensão Pulmonar , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/cirurgia , Hipertensão Pulmonar/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Radiofrequência/efeitos adversos , Cateterismo Cardíaco
17.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
18.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37889200

RESUMO

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos
19.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37746923

RESUMO

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Veia Cava Superior , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA