Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Rev Recent Clin Trials ; 14(2): 95-105, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30706789

RESUMO

INTRODUCTION: Ischemic heart diseases are the major leading cause of death worldwide. Revascularization procedures dramatically reduced the overall risk for death related to acute coronary syndromes. Two kinds of myocardial revascularization can grossly be outlined: percutaneous coronary intervention (PCI) and surgical coronary artery bypass graft intervention (CABG). The net clinical benefit coming from these two kinds of procedures is still under debate. METHODS: We have traced the state-of-the-art background about myocardial revascularization procedures by comparing the most important trials dealing with the evaluation of percutaneous interventions versus a surgical approach to coronary artery diseases. RESULTS: Both PCI and CABG have become effective treatments for revascularization of patients suffering from advanced CAD. The advance in technology and procedural techniques made PCI an attractive and, to some extent, more reliable procedure in the context of CAD. However, there are still patients that cannot undergo PCI and have to be rather directed towards CABG. CONCLUSION: CABG still remains the best strategy for the treatment of multiple vessel CAD due to improved results in term of survival and freedom from reintervention. Anyway, a systematic, multidisciplinary approach to revascularization is the fundamental behaviour to be chased in order to effectively help the patients in overcoming its diseases. The creation of the "heart team" seems to be a good option for the correct treatment of patients suffering from stable and unstable CAD.


Assuntos
Doença da Artéria Coronariana/cirurgia , Revascularização Miocárdica , Intervenção Coronária Percutânea , Humanos , Resultado do Tratamento
3.
J Cardiovasc Med (Hagerstown) ; 19(11): 664-668, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30299409

RESUMO

AIMS: In addition to the transfemoral route, common approaches for transcatheter aortic valve implantation (TAVI) are the transapical and transaortic ones. Yet, these are associated with morbidity. The transsubclavian approach (TSA) is an alternative to minimize invasiveness. METHODS: Fifteen consecutive patients underwent TAVI via TSA using the CoreValve Evolut R. The 14F delivery system without sheath was directly introduced into the artery. RESULTS: Success was 100%; contrast volume was 99.4 ±â€Š29.58 ml. Patients were extubated after 1.66 ±â€Š0.89 h. Hemoglobin drop was 0.64 ±â€Š0.28 g/dl. There were no complications. Hospital stay was 4.53 ±â€Š1.24 days: 11 patients were discharged home, the remainder to rehabilitation. CONCLUSION: TSA is associated with limited morbidity, early patient mobilization, short hospitalization.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Próteses Valvulares Cardíacas , Artéria Subclávia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Deambulação Precoce , Feminino , Humanos , Tempo de Internação , Masculino , Desenho de Prótese , Punções , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Heart Vessels ; 33(3): 291-298, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29027587

RESUMO

Takotsubo cardiomyopathy (TTC) is characterized by transient systolic ventricular dysfunction. It is supposed to be caused by a cathecolaminergic wave which leads to myocardial stunning through a massive action on beta2-adrenoreceptor. Moreover, beta2-receptor hyperactivity negatively influences endothelial function. It can be detected by brachial flow mediated dilation (b-FMD) which assesses endothelium regulated vasomotility. The study aim is to analyze the b-FMD variability during hospitalization in 50 patients admitted with TTC. In addition, we investigated a possible correlation between b-FMD at admission and both length of hospital stay (LOHS) and troponin I peak. We detected b-FMD by measuring the hypoxic induced vasoreactivity through assessing brachial artery dilation after 5 min of iatrogenic ischemia obtained by inflating a sphygmomanometer cuff. Artery diameter modifications were assessed by high-resolution ultrasound, and a dedicated software calculated accurately the percentage of dilation after ischemia by comparing it to the basal. These values were measured at admission and on discharge. The obtained values were compared for each patient to explore their variability during hospitalization. Moreover, the correlation between the b-FMD at admission and both the troponin I peak and the LOHS was investigated. There was a statistical significant difference between mean FMD measured at admission and at discharge (respectively 1.54 ± 0.34 and 8.92 ± 2.48%; p < 0.001). Moreover, we found a significant negative correlation between troponin I peak and FMD values at admission (r = - 0.7645; p < 0.001) and a significant inverse correlation between FMD at admission and LOHS (r = - 0.7543; p < 0.001). There is a significant improvement of b-FMD during hospitalization in patients admitted for Tako-Tsubo Cardiomyopathy. Moreover, for the first time, a direct correlation among b-FMD, troponin I peak and LOHS has been detected.


Assuntos
Artéria Braquial/fisiopatologia , Endotélio Vascular/fisiopatologia , Miocárdio/metabolismo , Cardiomiopatia de Takotsubo/fisiopatologia , Troponina I/metabolismo , Vasodilatação/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/metabolismo , Ultrassonografia
6.
G Ital Cardiol (Rome) ; 18(2 Suppl 1): 31S-34S, 2017 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-28398399

RESUMO

Aortic injury is a rare but severe complication that may occur during transcatheter aortic valve implantation (TAVI). Few patients with type A dissection are treated surgically because of the high rate of postoperative mortality and neurological complications in this high-risk population; thoracic endovascular aortic repair is rare too, and technically challenging because of the anatomical variations of spiral type A aortic dissection. Sometimes a watchful waiting strategy could be the best solution. We report the case of an acute, extended aortic type A dissection occurred during a TAVI procedure, probably due to the rupture of the dedicated sheath, and conservatively managed.


Assuntos
Dissecção Aórtica/etiologia , Complicações Intraoperatórias/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença Aguda , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
7.
Curr Neurovasc Res ; 14(1): 39-45, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27823553

RESUMO

According to the American Heart Association (AHA), primitive dilated cardiomyopathy (PDCM) is a "progressive dilation of the left or both ventricles and a depressed contractility in the absence of abnormal load conditions". It evolves in progressive heart-failure. The term "cardiogenic dementia" expresses the intimate connection between heart diseases and cognitive functions. The association between PDCM and the neuropsychological functions is unclear: the main pathophysiological hypotheses are cerebral hypoperfusion and cardiogenic emboli. The aim of this study is to evaluate the impact that the PDCM has on neuropsychological decline and to detect early echocardiographic markers of cognitive impairment. We enrolled 235 patients: 168 suffering from PDCM as sample group and 67 suffering from hypertensive dilated cardiomyopathy (HTCM) as control group. They underwent a cardiology examination and a neuropsychological assessment. A p<0.05 was considered significant. The two groups showed no differences in risk factors, demographic and cardiovascular parameters (except for dimensions of aortic root, left atrium and ventricle which appeared greater in PDCM and left ventricle ejection fraction that appeared lower in PDCM). Among administered neuropsychological tests, only the Stroop Test (which explores executive and attentive functions) appeared significantly lower in PDCM (p = 0.029). Moreover left ventricle end-diastolic diameter was inversely related to the Stroop Test Score (r= -0.32). PDCM doesn't appear to be at the basis of a generalized cognitive and neuropsychological decline. Only the executive functions seem impaired in PDCM. Left ventricle dilation seems to be associated to attentive and executive functions decline.


Assuntos
Cardiomiopatia Dilatada/fisiopatologia , Função Executiva/fisiologia , Adulto , Idoso , Cognição/fisiologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Função Ventricular Esquerda/fisiologia
8.
Surg Technol Int ; 29: 201-206, 2016 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-27466865

RESUMO

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) technique represents a real revolution in the field of interventional cardiology and medicine, in particular for the treatment of severe aortic valve stenosis in elderly patients or in patients when the periprocedural risk for the traditional surgical option is considered too high, as an alternative to the traditional aortic valve replacement. Although experience on the valves of the last generation is still limited in terms of time, the data currently available are definitely moving in the direction of a minimum hospital mortality (1%) as well as a drastic reduction in the incidence of complications when compared to the devices of the previous generation. Finally, the evolution of specified materials of the newest generation have greatly enhanced safety and efficacy of TAVI procedures in the last years. In order to ensure the selection of the most appropriate valve and the success of the procedure, the role of cardiac imaging (computed tomography scan evaluation and angiography) is crucial. These examinations require the use of contrast medium in patients suffering from renal dysfunction at the baseline. The need for fluoroscopy and angiography using contrast agents to aid positioning of the valve may lead to contrast-induced nephropathy (CIN) as one form or one etiology of acute kidney injury (AKI), which is associated with increased morbidity and mortality. The aim of our study is to investigate the accuracy of intravascular ultrasound (IVUS-a technique which does not need contrast) for the assessment of native valve measures in patients undergoing TAVI by comparing values obtained with IVUS to those ones previously obtained in the same patients with computed tomography (CT) scans. MATERIAL AND METHODS: We enrolled 25 consecutive patients (10 males, average age 81.3±5,1 years) who underwent TAVI with femoral access in our Cardiac Surgery Cath-Lab (University of Bari) from January to October 2015 (Logistic EuroSCORE 21.6±15.4%; STS score mortality 20.9±14.9%). Each patient scheduled for TAVI underwent coronary angiography and high resolution angio-CT in order to obtain a complete evaluation (diameters, perimeters, and areas at annulus level, -3mm level, +15mm level, height of coronary ostia, shape, and conformation of left ventricle outflow tract, conformation, and calcifications of aortic and ileo-femoral axis) to choose the most suitable prosthetic aortic valve for each patient. In all patients, during the procedure (before the prosthetic valve implantation), we executed a manual IVUS pullback (from left ventricle outflow tract to ascending aorta) by using a 7F IVUS probe (Volcano Corporation, San Diego, CA). On the recorded IVUS pullback, a second operator (who did not know the values obtained by CT measurements) identified the aortic annulus and, at this level, measured: minimum and maximum diameter; perimeter; derived perimeter, and area. The t-student test has been used to compare the averages of these IVUS values to the CT ones. A p value< 0.05 was considered as statistically significant. RESULTS: Independently from the kind and size of implanted prosthetic valve, no statistical differences were found when the averages of all considered parameters (obtained both with CT and IVUS) were compared. The following are the results obtained: minimum diameter (CT: 19,62mm±1,10 vs. IVUS: 19,55mm±1,40; p=0.41); maximum diameter (CT: 24,73mm±2,42 vs. IVUS: 25,9mm±1,80; p=0.08); perimeter (CT: 72,05mm±4,36 vs. IVUS: 73,32mm±6,09; p=0.164); derived perimeter (CT: 22,94mm±1,40 vs. IVUS: 23,32mm ± 1,95; p=0,198); and area (CT: 3,99cm2 ±0,97 vs. IVUS: 4,06 cm2 ± 0,47; p=0,073) (Figs. 1-3). CONCLUSIONS: These preliminary data suggest accurate IVUS measures when compared to CT in the evaluation of valve parameters considered (minimum and maximum diameters, area, perimeter, and derived perimeter at the annulus level). In order to confirm these findings and to give them statistical significance, it will be necessary to increase the sample size.


Assuntos
Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia
9.
Coron Artery Dis ; 27(2): 151-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26717005

RESUMO

In recent years, bioresorbable vascular scaffolds (BVS) have been introduced into clinical practice. The main advantage of BVS is that they overcome the problem of the foreign body in the treated artery. BVS, once placed into narrowed coronary vessels, behave like a conventional drug-eluting stent, but a device that disappears over time can preserve the anatomy and physiology of the treated vessel. The progression of stenosis after stenting has been attributed, at least in part, to inflammation around metallic struts, that, however, disappears gradually when using BVS. BVS have proven to be effective and safe as drug-eluting stents; in fact, the rate of adverse cardiovascular events and scaffold thrombosis in patients is low. The aim of this review article is to provide a comprehensive and updated description of the status of the art on BVS, highlighting the current evidence and future perspectives of this technology.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Doença da Artéria Coronariana/cirurgia , Alicerces Teciduais , Reestenose Coronária , Humanos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA