Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Malar J ; 20(1): 443, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34819092

RESUMO

BACKGROUND: Though most of Panamá is free from malaria, localized foci of transmission persist, including in the Guna Yala region. Government-led entomological surveillance using an entomological surveillance planning tool (ESPT) sought to answer programmatically-relevant questions that would enhance the understanding of both local entomological drivers of transmission and gaps in protection that result in persisting malaria transmission to guide local vector control decision-making. METHODS: The ESPT was used to design a sampling plan centered around the collection of minimum essential indicators to investigate the relevance of LLINs and IRS in the communities of Permé and Puerto Obaldía, Guna Yala, as well as to pinpoint any remaining spaces and times where humans are exposed to Anopheles bites (gaps in protection). Adult Anopheles were collected at three time points via human landing catches (HLCs), CDC Light Traps (LT), and pyrethrum spray catches (PSCs) during the rainy and dry seasons. Mosquitoes were identified to species via molecular methods. Insecticide susceptibility testing of the main vector species to fenitrothion was conducted. RESULTS: In total, 7537 adult Anopheles were collected from both sites. Of the 493 specimens molecularly confirmed to species, two thirds (n = 340) were identified as Nyssorhynchus albimanus, followed by Anopheles aquasalis. Overall Anopheles human biting rates (HBRs) were higher outdoors than indoors, and were higher in Permé than in Puerto Obaldía: nightly outdoor HBR ranged from 2.71 bites per person per night (bpn) (Puerto Obaldía), to 221.00 bpn (Permé), whereas indoor nightly HBR ranged from 0.70 bpn (Puerto Obaldía) to 81.90 bpn (Permé). Generally, peak biting occurred during the early evening. The CDC LT trap yields were significantly lower than that of HLCs and this collection method was dropped after the first collection. Pyrethrum spray catches resulted in only three indoor resting Anopheles collected. Insecticide resistance (IR) of Ny. albimanus to fenitrothion was confirmed, with only 65.5% mortality at the diagnostic time. CONCLUSION: The early evening exophagic behaviour of Anopheles vectors, the absence of indoor resting behaviours, and the presence of resistance to the primary intervention insecticide demonstrate limitations of the current malaria strategy, including indoor residual spraying (IRS) and long-lasting insecticidal nets (LLINs), and point to both gaps in protection and to the drivers of persisting malaria transmission in Guna Yala. These findings highlight the need for continued and directed entomological surveillance, based on programmatic questions, that generates entomological evidence to inform an adaptive malaria elimination strategy.


Assuntos
Anopheles/fisiologia , Resistência a Inseticidas , Mosquiteiros Tratados com Inseticida/estatística & dados numéricos , Inseticidas/administração & dosagem , Malária/transmissão , Mosquitos Vetores/fisiologia , Animais , Feminino , Humanos , Masculino , Controle de Mosquitos , Panamá
2.
J Water Health ; 9(1): 187-99, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21301126

RESUMO

The relationship between temperature, high pH, desiccation, decomposition, pathogen destruction, and user operation in active double vault urine diverting (DVUD) composting latrines located in the Bocas del Toro region of Panama was assessed. Latrine samples were analyzed for temperature, pH, % moisture, carbon-to-nitrogen (C/N) ratio, and presence of specific pathogens. Surveys and visual inspections were used to verify use and type of dry material desiccant added. Measurements supported findings that compost latrines do not reach temperatures sufficient to destroy all pathogens. pH measurements showed that many latrines were operating within the range for ideal aerobic decomposition, a pH of 7.5-8.5, but only 17% of latrines measured pH 9 or above. Almost 100% of composting latrine users added sawdust and wood ash, to lower moisture level and provide carbon for decomposition. However, the recommended amount of desiccant added was insufficient to reduce moisture to the suggested 25% for pathogen destruction and C/N ratios remained in the range of raw human faeces. Importantly, pathogens, mainly helminths, were still present in compost stored for the 6-month contact time. The latrines have conflicting goals of pathogen destruction and aerobic decomposition. Recommendations are made regarding operation of composting latrines and disposal of composted material.


Assuntos
Biodegradação Ambiental , Carbono/análise , Fezes/microbiologia , Fezes/parasitologia , Nitrogênio/análise , Banheiros , Animais , Bactérias/classificação , Bactérias/isolamento & purificação , Entamoeba/isolamento & purificação , Fezes/química , Giardia lamblia/isolamento & purificação , Helmintos/classificação , Helmintos/isolamento & purificação , Humanos , Higroscópicos/química , Panamá , Solo , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA