Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 31(7): 10920-10933, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38216815

RESUMO

This study established the simultaneous determination of the selected endocrine-disrupting compounds (EDCs) and pesticides in rock, soil, water, moss, and feces samples collected from the Antarctic region. The spray-assisted droplet formation-based liquid phase microextraction (SADF-LPME) coupled to GC-MS system was developed and validated for the screening and monitoring of 29 selected EDCs and pesticides. Binary solvent system, 1:1 (v/v) dichlormethane: 1,2-dichloroethane mixture was employed as an extraction solvent and sprayed onto sample or standard solutions using a straightforward and practical spray apparatus. The factors affecting the extraction process such as extraction solvent type and ratio, extraction solvent volume (spray repetition), vortexing period, and sample pH were properly optimized. Analytical figures of the merit of the method were recorded under the optimal extraction/chromatographic conditions. The LOD, LOQ, and enhancement factor were in the range of 1.0 to 6.6 ng/g, 3.2 to 22.1 ng/g, and 3.7 to 158.9, respectively. The method demonstrated a good linear working range for all the selected analytes with proper coefficients of determination. The usability and reliability of the microextraction strategy was confirmed using seawater, moss, and soil samples, and the %recoveries were within an acceptable range (> 70%) for all examined samples. The environmental samples collected from the Horseshoe and Faure Islands of the Antarctica region were analyzed to assess the potential pollution of EDCs and pesticides. This method has the potential to be employed for the analysis of EDCs in routine analytical laboratories and for controlling and screening the organic pollutant content of different environmental samples.


Assuntos
Disruptores Endócrinos , Microextração em Fase Líquida , Praguicidas , Água/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Disruptores Endócrinos/análise , Regiões Antárticas , Microextração em Fase Líquida/métodos , Reprodutibilidade dos Testes , Solo , Solventes/química
2.
Turk J Chem ; 47(5): 1075-1084, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38173744

RESUMO

In this study, a portable smartphone-based digital image colorimetric system (SDIC) was designed and integrated with a solidified floating organic drop microextraction method (SFODME) for the quantification of methyl red in textile wastewater samples. The RGB (red, green, and blue) data were evaluated for each captured image, and the green channel was selected for quantification due to its linear response for the analyte. Under optimal conditions, an acceptable linear range was recorded for the analyte. The proposed method recorded a limit of detection (LOD) value of 0.046 mg/L. The developed microextraction method was also combined with UV-Vis spectrophotometry, which recorded an LOD value of 0.012 mg/L. Real sample analysis was carried out with textile wastewater samples to check the applicability/accuracy of the developed method, using a matrix matching calibration strategy to enhance quantification accuracy. Satisfactory percent recoveries in the range of 93.3%-114.3% and 92%-92.7% were recorded for the SFODME-SDIC and SFODME-UV methods, respectively.

3.
Environ Monit Assess ; 192(2): 133, 2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-31970566

RESUMO

In this study, a new liquid-phase microextraction method termed sieve-conducted two-syringe-based pressurized liquid-phase microextraction (SCTS-PLPME) was developed as a preconcentration tool for indium. Here, two syringes were connected to each other by an apparatus to produce an environment subject to pressure. The pressure created between the two syringes by simultaneous movements of the syringe plungers (to and fro) generated an efficient dispersion and this eliminated the need for dispersive solvents. Determination of indium after preconcentration was carried out with a slotted quartz tube attached flame atomic absorption spectrometer (SQT-FAAS). The detection limit (LOD) and quantification limit (LOQ) of the developed method were calculated as 19.2 and 72.2 µg L-1, respectively. The reliability and accuracy of the developed method was tested by performing recovery studies on lake water spiked at different concentrations and the obtained percent recoveries were between 101.2 and 106.9%.


Assuntos
Microextração em Fase Líquida , Poluentes Químicos da Água , Monitoramento Ambiental , Índio/análise , Limite de Detecção , Microextração em Fase Líquida/métodos , Quartzo , Reprodutibilidade dos Testes , Espectrofotometria Atômica , Seringas , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA