Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Vox Sang ; 117(10): 1163-1170, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36102116

RESUMO

BACKGROUND AND OBJECTIVES: Di-ethyl-hexyl-phthalate (DEHP) is currently the main plasticizer used for whole blood collection systems. However, in Europe, after May 2025, DEHP may no longer be used above 0.1% (w/w) in medical devices. DEHP stabilizes red cell membranes, thereby suppressing haemolysis during storage. Here we compared in vitro quality parameters of red cell concentrates (RCCs) collected and stored in DEHP-, DINCH- or DINCH/BTHC-PVC hybrid blood bags with saline-adenine-glucose-mannitol (SAGM) or phosphate-adenine-glucose-guanosine-saline-mannitol (PAGGSM) storage solution. Last, we performed haemovigilance surveillance for RCC collected in DINCH-PVC and stored in PAGGSM/BTHC-PVC. MATERIALS AND METHODS: In vitro quality parameters of RCC were determined during 42 days of storage. Haemovigilance surveillance was conducted to compare the frequency and type of transfusion reaction. RESULTS: Haemolysis levels were increased in SAGM/BTHC-PVC as compared to SAGM/DEHP-PVC (0.66% ± 0.18% vs. 0.36% ± 0.17%). PAGGSM storage solution was able to adequately suppress haemolysis to levels observed during storage in SAGM/DEHP-PVC, both in BTHC-PVC (0.38% ± 0.12%), and to a slightly lesser extent in DINCH-PVC (0.48% ± 0.17%). A total of 1650 PAGGSM/BTHC-PVC and 5662 SAGM/DEHP-PVC RCC were transfused yielding a transfusion reaction frequency of 0.24% (95% CI 0.0000-0.0048) and 0.44% (95% CI 0.0027-0.0061) respectively. CONCLUSION: The in vitro quality of RCC stored in PAGGSM/BTHC-PVC and SAGM/DEHP-PVC is comparable. There is no indication that transfusion of erythrocytes stored in PAGGSM/BTHC-PVC results in increased transfusion reaction frequency. These initial results provide a basis for further clinical evaluation to narrow down the confidence interval of transfusion reaction frequency.


Assuntos
Carcinoma de Células Renais , Dietilexilftalato , Neoplasias Renais , Reação Transfusional , Adenina/farmacologia , Preservação de Sangue/métodos , Butiratos , Carcinoma de Células Renais/metabolismo , Eritrócitos/metabolismo , Glucose/metabolismo , Guanosina , Hemólise , Humanos , Neoplasias Renais/metabolismo , Manitol/farmacologia , Fosfatos/metabolismo , Plastificantes , Cloreto de Polivinila , Cloreto de Sódio
2.
Transfus Med ; 32(1): 53-63, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34761451

RESUMO

OBJECTIVES: Our objectives were to determine the separation characteristics and blood product quality of a gravity-driven microfiltration blood separation system (HemoClear, The Netherlands). BACKGROUND: A range of centrifugal blood separation devices, including intraoperative cell salvage devices (cell savers) and apheresis machines, are available to assist in preparing both allogenic and autologous blood products. These devices are expensive to operate and require extensive training. METHODS AND MATERIALS: Nine whole blood units were collected under standard conditions and analysed for haematological parameters, thromboelastographic properties, platelet morphology and activation, and red blood cell (RBC) deformability and morphology. Three whole blood units were separated by means of the HemoClear device, into a liquid and cellular component. The cellular component was diluted with SAGM and cold stored for 14 days. To simulate cell salvage six whole blood units were diluted with isotonic saline, followed by multiple HemoClear separation rounds. RESULTS: The recovery of both RBCs (100 ± 1.6%) and white blood cells (99 ± 4.5%) after undiluted filtration were very high, while platelet recovery was high (83 ± 3.0%). During the filtration, and cold storage after filtration storage both the non-deformable RBC fraction and the RBC maximum elongation remained stable. Parameters of thromboelastography indicated that platelets remain functional after filtration and after 7 days of cold storage. In the cell salvage simulation the total protein load in the cellular fraction was reduced by 65 ± 4.1% after one washing round and 84 ± 1.9% after two consecutive washing rounds. CONCLUSION: The novel blood filter studied effectively separates whole blood into diluted plasma and platelet-rich RBCs. Moreover, the device effectively washed diluted whole blood, driving over 80% of proteins to the liquid component.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Preservação de Sangue , Contagem de Eritrócitos , Eritrócitos , Humanos , Leucócitos
3.
Transfusion ; 58(11): 2627-2634, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30265755

RESUMO

BACKGROUND: Apheresis is increasingly being applied to collect cells or plasma, even allowing the collection of multiple blood components during one procedure. Although the quality of the cellular and plasma products that are obtained by apheresis have been extensively studied and shown to be of high quality, the impact of apheresis on the red blood cells (RBCs) that are returned to the donor has not been investigated. STUDY DESIGN AND METHODS: The effect of the plasma- or plateletpheresis procedures by four different devices-MCS+ (Haemonetics), PCS2 (Haemonetics), Trima Accel (Terumo BCT), and Autopheresis-C (Auto-C, Fresenius Kabi)-on the RBCs that are returned to the donor was tested in a blinded, prospective trial in a cohort of 25 donors. RESULTS: A rheologic analysis of donor RBCs before and after plasma- or plateletpheresis showed no differences in outcome. However, a strong increase in hemolysis was found in samples from the Trima Accel devices after plateletpheresis, compared to all other machines tested. Furthermore, an increase in complement deposition on RBCs was seen after all plasmapheresis procedures (MCS+, PCS2, and Auto-C). Finally, a significant decrease in the expression of the complement-regulating protein CD59 was seen in all postapheresis samples as well as a significant decrease of the adhesion molecule CD147. CONCLUSION: The increase in complement deposition and the decrease in the expression of CD59 suggests that RBC clearance might be enhanced after return to the donor. Possible side effects due to an increase in hemolysis after Trima Accel plateletpheresis should be further investigated.


Assuntos
Remoção de Componentes Sanguíneos/efeitos adversos , Eritrócitos/metabolismo , Antígenos CD59/metabolismo , Citometria de Fluxo , Hemólise , Humanos , Plaquetoferese/efeitos adversos
4.
Transfusion ; 55(3): 522-31, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25331824

RESUMO

BACKGROUND: The plasticizer di(2-ethylhexyl)phthalate (DEHP) is a common component in blood bags. DEHP is noncovalently bound to polyvinylchloride (PVC) polymer and can leach into the blood product. There are public concerns that exposure to DEHP might induce developmental and reproductive toxicity in humans. The aim of this study was to evaluate an alternative plasticizer, di(isononyl) cyclohexane-1,2-dicarboxylate (Hexamoll DINCH, BASF SE), for its use in blood bags. STUDY DESIGN AND METHODS: Whole blood (WB) was collected into DEHP-containing and DEHP-free collection systems. After overnight hold, WB was centrifuged and separated in plasma, buffy coat, and red blood cells (RBCs). Buffy coats and plasma were used to make platelet (PLT) concentrates in DEHP-free systems. After addition of additive solution (AS), SAG-M, PAGGS-M, AS-3, or PAGGG-M, RBCs were leukoreduced and analyzed for in vitro characteristics and plasticizer levels during storage. RESULTS: The use of DINCH-based systems had no effect on WB composition, blood processing, and plasma quality. PLT in vitro quality variables were maintained during storage in DEHP-free systems. During storage in SAG-M, hemolysis was significantly higher in DINCH-PVC while potassium leakage and adenosine triphosphate content were comparable. During storage in alternative ASs, hemolysis was reduced compared to storage in SAG-M. CONCLUSIONS: The complete absence of DEHP in the collection system had no effect on WB composition, processing, or plasma and PLT quality. During storage in SAG-M, the absence of DEHP resulted in increased hemolysis. With alternative ASs like PAGGS-M, AS-3, or PAGGG-M, the absence of DEHP had no effect on hemolysis. Leakage of DINCH into the blood product was less pronounced than that of DEHP.


Assuntos
Preservação de Sangue/instrumentação , Coleta de Amostras Sanguíneas/instrumentação , Ácidos Cicloexanocarboxílicos , Ácidos Dicarboxílicos , Dietilexilftalato , Plastificantes , Adenina/farmacologia , Células Sanguíneas/citologia , Células Sanguíneas/efeitos dos fármacos , Coagulação Sanguínea/efeitos dos fármacos , Citratos/farmacologia , Criopreservação/instrumentação , Dietilexilftalato/sangue , Glucose/farmacologia , Guanosina/farmacologia , Hemólise/efeitos dos fármacos , Humanos , Técnicas In Vitro , Procedimentos de Redução de Leucócitos , Manitol/farmacologia , Soluções Farmacêuticas/farmacologia , Fosfatos/farmacologia , Plastificantes/análise , Cloreto de Sódio/farmacologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA