Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Front Pain Res (Lausanne) ; 4: 1237090, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028428

RESUMO

Immersive virtual reality (VR) is a promising tool to reduce pain in clinical setting. Digital scripts displayed by VR disposals can be enriched by several analgesic interventions, which are widely used to reduce pain. One of these techniques is hypnosis induced through the VR script (VRH) which is facilitated by immersive environment and particularly efficient even for low hypnotizable patients. The aim of this study is to assess the efficacy of a VRH script on experimentally induced cold pain perception (intensity and unpleasantness) and physiological expression. 41 healthy volunteers had been recruited in this within-subjects study. They received 9 stimulations of 20 s (3 non-nociceptive cold; 3 low nociceptive cold and 3 highly nociceptive cold) during a VRH session of 20 min (VRH condition) or without VRH (noVRH condition). Physiological monitoring during the cold pain stimulation protocol consisted of recording heart rate, heart rate variability and respiratory frequency. Maximum cold pain intensity perception, measured through the visual analog scale (VAS) on 10, was of 3.66 ± 1.84 (VAS score/10) in noVRH condition and 2.46 ± 1.54 in VRH (Wilcoxon, p < 0.0001). Considering pain unpleasantness perception, 3.68 ± 2.06 in noVRH and 2.21 ± 1.63 in VRH (Wilcoxon, p < 0.0001). Hypnotizability negatively correlated with the decrease in VAS intensity from noVRH to VRH (Spearman r = -0.45; p = 0.0038). In our sample, we found that 31/41 volunteers (75.6%) displayed a reduction of more than 10% of their VAS pain intensity and unpleasantness scores. Trait anxiety was the best predictor of the VRH responders, as well as heart rate variability. In addition, respiratory rate was diminished under VRH in every subgroup. VRH is an effective tool to reduced pain intensity and unpleasantness in a vast majority of healthy subjects. We further indicate in this study that heart rate variability parameter RMSSD (root mean square of successive differences) is a good predictor of this effect, as well as anxiety as a personality trait (but not state anxiety). Further studies are expected to determine more precisely to whom it will be the most useful to offer tailored, non-pharmacological pain management solutions to patients.

2.
EJNMMI Phys ; 9(1): 81, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36414716

RESUMO

PURPOSE: To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. METHODS: A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. RESULTS: We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. CONCLUSION: Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations.

3.
J Med Internet Res ; 24(7): e33255, 2022 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-35904872

RESUMO

BACKGROUND: Virtual reality hypnosis (VRH) is a promising tool to reduce pain. However, the benefits of VRH on pain perception and on the physiological expression of pain require further investigation. OBJECTIVE: In this study, we characterized the effects of VRH on the heat pain threshold among adult healthy volunteers while monitoring several physiological and autonomic functions. METHODS: Sixty healthy volunteers were prospectively included to receive nociceptive stimulations. The first set of thermal stimuli consisted of 20 stimulations at 60°C (duration 500 milliseconds) to trigger contact heat evoked potentials (CHEPs). The second set of thermal stimuli consisted of ramps (1°C/second) to determine the heat pain threshold of the participants. Electrocardiogram, skin conductance responses, respiration rate, as well as the analgesia nociception index were also recorded throughout the experiment. RESULTS: Data from 58 participants were analyzed. There was a small but significant increase in pain threshold in VRH (50.19°C, SD 1.98°C) compared to that in the control condition (mean 49.45°C, SD 1.87; P<.001, Wilcoxon matched-pairs signed-rank test; Cohen d=0.38). No significant effect of VRH on CHEPs and heart rate variability parameters was observed (all P>0.5; n=22 and n=52, respectively). During VRH, participants exhibited a clear reduction in their autonomic sympathetic tone, as shown by the lower number of nonspecific skin conductance peak responses (P<.001, two-way analysis of variance; n=39) and by an increase in the analgesia nociception index (P<.001, paired t-test; n=40). CONCLUSIONS: The results obtained in this study support the idea that VRH administration is effective at increasing heat pain thresholds and impacts autonomic functions among healthy volunteers. As a nonpharmacological intervention, VRH has beneficial action on acute experimental heat pain. This beneficial action will need to be evaluated for the treatment of other types of pain, including chronic pain.


Assuntos
Hipnose , Realidade Virtual , Adulto , Biomarcadores , Estudos Cross-Over , Humanos , Hipnose/métodos , Dor , Limiar da Dor/fisiologia , Estudos Prospectivos
4.
Surg Endosc ; 36(12): 9224-9233, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35831676

RESUMO

BACKGROUND: To prove feasibility of multimodal and temporal fusion of laparoscopic images with preoperative computed tomography scans for a real-time in vivo-targeted lymph node (TLN) detection during minimally invasive pelvic lymphadenectomy and to validate and enable such guidance for safe and accurate sentinel lymph node dissection, including anatomical landmarks in an experimental model. METHODS: A measurement campaign determined the most accurate tracking system (UR5-Cobot versus NDI Polaris). The subsequent interventions on two pigs consisted of an identification of artificial TLN and anatomical landmarks without and with augmented reality (AR) assistance. The AR overlay on target structures was quantitatively evaluated. The clinical relevance of our system was assessed via a questionnaire completed by experienced and trainee surgeons. RESULTS: An AR-based robotic assistance system that performed real-time multimodal and temporal fusion of laparoscopic images with preoperative medical images was developed and tested. It enabled the detection of TLN and their surrounding anatomical structures during pelvic lymphadenectomy. Accuracy of the CT overlay was > 90%, with overflow rates < 6%. When comparing AR to direct vision, we found that scores were significatively higher in AR for all target structures. AR aided both experienced surgeons and trainees, whether it was for TLN, ureter, or vessel identification. CONCLUSION: This computer-assisted system was reliable, safe, and accurate, and the present achievements represent a first step toward a clinical study.


Assuntos
Realidade Aumentada , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Linfonodo Sentinela , Cirurgia Assistida por Computador , Humanos , Feminino , Suínos , Animais , Procedimentos Cirúrgicos Robóticos/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Laparoscopia/métodos , Procedimentos Cirúrgicos em Ginecologia , Cirurgia Assistida por Computador/métodos
5.
Surg Endosc ; 35(4): 1844-1850, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32342212

RESUMO

BACKGROUND: Clinical evaluation of the demarcation line separating ischemic from non-ischemic liver parenchyma may be challenging. Hyperspectral imaging (HSI) is a noninvasive imaging modality, which combines a camera with a spectroscope and allows quantitative imaging of tissue oxygenation. Our group developed a software to overlay HSI images onto the operative field, obtaining HSI-based enhanced reality (HYPER). The aim of the present study was to evaluate the accuracy of HYPER to identify the demarcation line after a left vascular inflow occlusion during an anatomical left hepatectomy. MATERIALS AND METHODS: In the porcine model (n = 3), the left branches of the hepatic pedicle were ligated. Before and after vascular occlusion, HSI images based on tissue oxygenation (StO2), obtained through the Near-Infrared index (NIR index), were regularly acquired and superimposed onto RGB video. The demarcation line was marked on the liver surface with electrocautery according to HYPER. Local lactates were measured on blood samples from the liver surface in both ischemic and perfused segments using a strip-based device. At the same areas, confocal endomicroscopy was performed. RESULTS: After ligation, HSI demonstrated a significantly lower oxygenation (NIR index) in the left medial lobe (LML) (0.27% ± 0.21) when compared to the right medial lobe (RML) (58.60% ± 12.08; p = 0.0015). Capillary lactates were significantly higher (3.07 mmol/L ± 0.84 vs. 1.33 ± 0.71 mmol/L; p = 0.0356) in the LML versus RML, respectively. Concordantly, confocal videos demonstrated the absence of blood flow in the LML and normal perfusion in the RML. CONCLUSIONS: HYPER has made it possible to correctly identify the demarcation line and quantify surface liver oxygenation. HYPER could be an intraoperative tool to guide perfusion-based demarcation line assessment and segmentation.


Assuntos
Fígado/diagnóstico por imagem , Fígado/cirurgia , Análise Espectral , Animais , Diagnóstico por Imagem , Hepatectomia , Suínos
6.
Surg Innov ; 27(5): 424-430, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32886583

RESUMO

Anatomical liver resection (ALR) is the preferred oncological approach for the treatment of primary liver malignancies, such as hepatocellular carcinoma and intrahepatic cholangiocarcinoma. The demarcation line (DL) is formed by means of selective vascular occlusion and is used by surgeons to guide ALR. Emerging intraoperative technologies are playing a major role to enhance the surgeon's vision and ensure a precise oncologic surgery. In this article, a brief overview of modalities to assess the DL during ALRs is presented, from the established conventional techniques to future perspectives.


Assuntos
Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Carcinoma Hepatocelular/cirurgia , Colangiocarcinoma/cirurgia , Hepatectomia , Humanos , Verde de Indocianina , Neoplasias Hepáticas/cirurgia
7.
PLoS One ; 9(9): e106675, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25203629

RESUMO

Hepatocellular carcinoma (HCC) is one of the most common cancer related deaths worldwide. One of the main challenges in cancer treatment is drug delivery to target cancer cells specifically. Preclinical evaluation of intratumoral drugs in orthotopic liver cancer mouse models is difficult, as percutaneous injection hardly can be precisely performed manually. In the present study we have characterized a hepatoma model developing a single tumor nodule by implantation of Hep55.1C cells in the liver of syngeneic C57BL/6J mice. Tumor evolution was followed up by µCT imaging, and at the histological and molecular levels. This orthotopic, poorly differentiated mouse HCC model expressing fibrosis, inflammation and cancer markers was used to assess the efficacy of drugs. We took advantage of the high precision of a previously developed robotized system for automated, image-guided intratumoral needle insertion, to administer every week in the tumor of the Hep55.1C mouse model. A significant tumor growth inhibition was observed using our robotized system, whereas manual intraperitoneal administration had no effect, by comparison to untreated control mice.


Assuntos
Carcinoma Hepatocelular/patologia , Avaliação de Medicamentos/instrumentação , Neoplasias Hepáticas/patologia , Robótica , Microtomografia por Raio-X , Animais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/tratamento farmacológico , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Modelos Animais de Doenças , Doxorrubicina/farmacologia , Doxorrubicina/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Camundongos , Camundongos Endogâmicos C57BL , Ensaios Antitumorais Modelo de Xenoenxerto
8.
IEEE Trans Biomed Eng ; 60(8): 2193-204, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23475327

RESUMO

The development of imaging devices adapted to small animals has opened the way to image-guided procedures in biomedical research. In this paper, we focus on automated procedures to study the effects of the recurrent administration of substances to the same animal over time. A dedicated system and the associated workflow have been designed to percutaneously position a needle into the abdominal organs of mice. Every step of the procedure has been automated: the camera calibration, the needle access planning, the robotized needle positioning, and the respiratory-gated needle insertion. Specific devices have been developed for the registration, the animal binding under anesthesia, and the skin puncture. Among the presented results, the system accuracy is particularly emphasized, both in vitro using gelose phantoms and in vivo by injecting substances into various abdominal organs. The study shows that robotic assistance could be routinely used in biomedical research laboratories to improve existing procedures, allowing automated accurate treatments and limited animal sacrifices.


Assuntos
Biópsia por Agulha/instrumentação , Biópsia por Agulha/veterinária , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/veterinária , Robótica/instrumentação , Gravação em Vídeo/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Stud Health Technol Inform ; 184: 117-21, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23400142

RESUMO

No-scar surgery, which aims at performing surgical operations without visible scars, is the vanguard in the field of Minimally Invasive Surgery. No-scar surgery can be performed with flexible instruments, carried by a guide under the vision of an endoscopic camera. This technique brings many benefits for the patient, but also introduces several difficulties for the surgeon. We aim at developing a teleoperated robotic system for assisting surgeons in this kind of operations. In this paper, we present a virtual simulator of the system that allows to assess different control strategies for our robot and to study possible mechanical issues.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Biológicos , Robótica/instrumentação , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Telemedicina/métodos , Cicatriz/etiologia , Cicatriz/prevenção & controle , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Design de Software , Cirurgia Assistida por Computador/instrumentação , Telemedicina/instrumentação
10.
IEEE Trans Biomed Eng ; 59(3): 805-15, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22186930

RESUMO

Transcranial magnetic stimulation is a noninvasive brain stimulation technique. It is based on current induction in the brain with a stimulation coil emitting a strong varying magnetic field. Its development is currently limited by the lack of accuracy and repeatability of manual coil positioning. A dedicated robotic system is proposed in this paper. Contrary to previous approaches in the field, a custom design is introduced to maximize the safety of the subject. Furthermore, the control of the force applied by the coil on the subject's head is implemented. The architecture is original and its experimental evaluation demonstrates its interest: the compensation of the head motion is combined with the force control to ensure accuracy and safety during the stimulation.


Assuntos
Robótica/instrumentação , Estimulação Magnética Transcraniana/instrumentação , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Imagens de Fantasmas , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA