Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
J Am Coll Cardiol ; 83(18): 1779-1798, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38692829

RESUMO

Right ventricular infarction (RVI) complicates 50% of cases of acute inferior ST-segment elevation myocardial infarction, and is associated with high in-hospital morbidity and mortality. Ischemic right ventricular (RV) systolic dysfunction decreases left ventricular preload delivery, resulting in low-output hypotension with clear lungs, and disproportionate right heart failure. RV systolic performance is generated by left ventricular contractile contributions mediated by the septum. Augmented right atrial contraction optimizes RV performance, whereas very proximal occlusions induce right atrial ischemia exacerbating hemodynamic compromise. RVI is associated with vagal mediated bradyarrhythmias, both during acute occlusion and abruptly with reperfusion. The ischemic dilated RV is also prone to malignant ventricular arrhythmias. Nevertheless, RV is remarkably resistant to infarction. Reperfusion facilitates RV recovery, even after prolonged occlusion and in patients with severe shock. However, in some cases hemodynamic compromise persists, necessitating pharmacological and mechanical circulatory support with dedicated RV assist devices as a "bridge to recovery."


Assuntos
Ventrículos do Coração , Disfunção Ventricular Direita , Humanos , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/etiologia , Ventrículos do Coração/fisiopatologia , Infarto do Miocárdio/fisiopatologia
3.
Cardiovasc Revasc Med ; 64: 70-75, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38538447

RESUMO

OBJECTIVES: This study evaluated the efficacy of a novel comprehensive shield designed to minimize radiation exposure (RE) to Physicians performing coronary and structural heart procedures. BACKGROUND: The Protego™ radiation shielding system (Image Diagnostics Inc., Fitchburg, Ma) is designed to provide comprehensive protection from RE and has been State certified sufficient to allow operators to perform procedures without orthopedically burdensome lead aprons. METHODS: This single center two-group cohort study assessed the efficacy of this shield in a large number of cardiac procedures (coronary and structural), comparing operator RE compared to standard protection methods (personal lead apparel and "drop down" shield). RESULTS: The Protego™ system reduced operator RE by 99 % compared to Standard Protection. RE was significantly lower at both "Head" level by thyroid median dose 0.0 (0.0, 0,0) vs 5.7 (2.9, 8.2) µSv (p < 0.001), as well as waist dose 0.0 (0.0, 0.0) vs 10.0 (5.0, 16.6) µSv (p < 0.001). "Zero" Total RE was documented by Raysafe™ in 64 % (n = 32) of TAVR cases and 73.2 % (n = 183) of the coronary cases utilizing Protego™. In contrast, standard protection did not achieve "Zero" exposure in a single case. These dramatic differences in RE were achieved despite higher fluoroscopy times in the Protego™ arm (11.9 ± 8.6 vs 14.3 ± 12.5 min, p = 0.015). Per case procedural exposure measured by Dose Area Product was higher in the Protego™ group compared to standard protection (115.4 ± 139.2 vs 74.9 ± 69.3, p < 0.001). CONCLUSION: The Protego™ shield provides total body RE protection for operators performing both coronary and structural heart procedures. This shield allows procedural performance without the need for personal lead aprons and has potential to reduce catheterization laboratory occupational health hazards.


Assuntos
Exposição Ocupacional , Saúde Ocupacional , Doses de Radiação , Exposição à Radiação , Proteção Radiológica , Radiografia Intervencionista , Humanos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/efeitos adversos , Exposição à Radiação/prevenção & controle , Exposição à Radiação/efeitos adversos , Proteção Radiológica/instrumentação , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/normas , Fatores de Risco , Medição de Risco , Lesões por Radiação/prevenção & controle , Lesões por Radiação/etiologia , Desenho de Equipamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Masculino , Monitoramento de Radiação , Feminino
5.
JACC Case Rep ; 4(19): 1267-1273, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36406921

RESUMO

We report a patient with severe mitral annular calcification, mitral stenosis/regurgitation, hypertrophic obstructive cardiomyopathy, and subaortic membrane treated with valved left atrium-left ventricle conduit, septal myectomy, and membrane resection. Subsequent thrombosis of the conduit prompted successful valve-in- mitral annular calcification transcatheter mitral valve replacement and laceration of the anterior mitral leaflet to prevent outflow obstruction. (Level of Difficulty: Advanced.).

9.
JACC Case Rep ; 3(9): 1174-1176, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34401753
10.
Catheter Cardiovasc Interv ; 97(2): 299-300, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33587803

RESUMO

In acute pulmonary embolism (PE), low cardiac output (CO)-hypotension results from disparate ventricular conditions: The left ventricle (LV) is under-filled and contracting vigorously, whereas the right ventricle (RV) is failing and dilated. The proximate cause of LV preload deprivation is thrombus-induced pulmonary vascular obstruction; abruptly increased pulmonary vascular resistance (PVR) induces acute RV systolic dysfunction which further compromises trans-pulmonary flow. "Escalation of Care" interventions (thrombolytics and aspiration thrombectomy) improve systemic hemodynamics by increasing LV preload delivery directly by reducing PVR and indirectly by relief of the strained failing RV.


Assuntos
Embolia Pulmonar , Disfunção Ventricular Direita , Ventrículos do Coração , Hemodinâmica , Humanos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Resultado do Tratamento , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia
11.
Catheter Cardiovasc Interv ; 97(6): 1301-1308, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33471957

RESUMO

In asymptomatic severe aortic (AR) and mitral regurgitation (MR), left ventricular (LV) dimension criteria were established to guide timing of valve replacement to prevent irreversible LV dysfunction. Given both lesions are primary LV volume overload ''leaks'', it might be expected that both lesions would induce similar impact on the LV and result in equivalent dimension criteria for intervention. However, the dimension-based intervention criteria for AR versus MR (developed through natural history studies), differ markedly. The pathophysiological foundations for such discordance have neither been fully elucidated nor emphasized. This case-based treatise compares the two regurgitant lesions with respect to: (a) ''total regurgitant circuits''; (b) ''driving pressures'' resulting in LV volume overload from each respective ''leak''; and (c) volume and afterload wall stresses imposed on the LV.Key points The ''total circuits'' of volume overload differ: The AR circuit includes the LV and systemic vasculature, whereas MR includes the LV ejecting into the left atrium/pulmonary veins and systemic circulation. The ''driving pressure'' of regurgitation and afterload are high with AR and low with MR. Differing ''total circuits'' and ''driving pressures'' impose disparate wall stresses upon the LV. Parallel and serial sarcomere replication occurs in AR, while only serial replication occurs in MR. It therefore follows that for regurgitation of similar severities, AR results in greater LV dilation at the point of irreversible myocardial dysfunction compared to MR. These considerations may explain, at least in part, the disparate dimension criteria employed for valve intervention for severe AR vs MR.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Dilatação , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 96(2): 382-383, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32797744

RESUMO

Rapid restoration of hemodynamics is key to successful shock management. The failing right ventricular (RV) is resilient and recovers if hemodynamics are supported while the underlying insulting cause is alleviated. Inotropic/vasopressor drugs constitute a "double-edged sword" that augment hemodynamics, but exacerbate myocardial and multiorgan injury. Impella RP mechanical support for RV shock stabilizes hemodynamics and is associated with favorable clinical outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Adolescente , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Hemodinâmica , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia , Adulto Jovem
16.
J Am Coll Cardiol ; 75(12): 1371-1382, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32216905

RESUMO

BACKGROUND: Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes. OBJECTIVES: The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents. METHODS: In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesion-related, nonculprit (untreated) lesion-related, or indeterminate. RESULTS: Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesion-related, 10.7% were nonculprit lesion-related, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesion-related MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors. CONCLUSIONS: Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/metabolismo , Stents Farmacológicos/tendências , Intervenção Coronária Percutânea/tendências , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/metabolismo , Idoso , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Metabolismo dos Lipídeos/fisiologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Sistema de Registros , Espectroscopia de Luz Próxima ao Infravermelho/tendências , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 95(6): 1240-1248, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31904891

RESUMO

Constrictive pericarditis (CP) and restrictive cardiomyopathy (RCM) are indolent disabling diseases of diastolic function. The two conditions share common pathophysiologic features, resulting in similar and overlapping clinical presentations, echocardiographic findings, and hemodynamic characteristics. However, their clinical course differs, as CP is surgically curable whereas RCM is a chronic condition managed medically. Separating these two entities is based on delineation of anatomic and physiologic derangements employing multimodality hemodynamic interrogation by advanced imaging techniques (Echo-Doppler, CT, and especially MRI) combined with sophisticated invasive hemodynamics.


Assuntos
Cardiomiopatia Restritiva/fisiopatologia , Hemodinâmica , Pericardite Constritiva/fisiopatologia , Adulto , Idoso , Cardiomiopatia Restritiva/diagnóstico por imagem , Cardiomiopatia Restritiva/terapia , Diagnóstico Diferencial , Ecocardiografia Doppler , Feminino , Monitorização Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Pericardite Constritiva/diagnóstico por imagem , Pericardite Constritiva/terapia , Valor Preditivo dos Testes , Prognóstico , Tomografia Computadorizada por Raios X
20.
Catheter Cardiovasc Interv ; 94(6): 886-892, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31454157

RESUMO

Patients presenting with hemodynamic instability attributable to left ventricular systolic dysfunction and concomitant severe mitral regurgitation (MR) are increasingly recognized and pose complex management challenges. Surgical therapy is typically precluded owing to prohibitive mortality. The role of percutaneous mechanical circulatory support in such cases is well established; however, such interventions may be neither sufficient to achieve optimal stability nor prove definitive. The advent of novel catheter-based mitral repair modalities now offers primary decisive therapeutic intervention. Three cases of cardiogenic shock with severe MR illustrate the salutary hemodynamic and clinical responses to percutaneous mechanical support and valve repair by mitral clip.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Hemodinâmica , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Choque Cardiogênico/terapia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/fisiopatologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA