Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 34(7): e4832, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32190911

RESUMO

Injectable solutions containing epinephrine (EPI) and norepinephrine (NE) are not stable, and their degradation is favored mainly by the oxidation of catechol moiety. As studies of these drugs under forced degradation conditions are scarce, herein, we report the identification of their degradation products (DP) in anesthetic formulations by the development of stability-indicating HPLC method. Finally, the risk assessment of the major degradation products was evaluated using in silico toxicity approach. HPLC method was developed to obtain a higher selectivity allowing adequate elution for both drugs and their DPs. The optimized conditions were developed using a C18 HPLC column, sodium 1-octanesulfonate, and methanol (80:20, v/v) as mobile phase, with a flow rate of 1.5 mL/min, UV detection at 199 nm. The analysis of standard solutions with these modifications resulted in greater retention time for EPI and NE, which allow the separation of these drugs from their respective DPs. Then, five DPs were identified and analyzed by in silico studies. Most of the DPs showed important alerts as hepatotoxicity and mutagenicity. To the best of our acknowledgment, this is the first report of a stability-indicating HPLC method that can be used with formulations containing catecholamines.


Assuntos
Anestésicos , Cromatografia Líquida de Alta Pressão/métodos , Epinefrina , Norepinefrina , Anestesia Dentária , Anestésicos/análise , Anestésicos/química , Anestésicos/toxicidade , Animais , Simulação por Computador , Estabilidade de Medicamentos , Epinefrina/análise , Epinefrina/química , Epinefrina/toxicidade , Limite de Detecção , Modelos Lineares , Camundongos , Norepinefrina/análise , Norepinefrina/química , Norepinefrina/toxicidade , Ratos , Reprodutibilidade dos Testes
2.
J Sep Sci ; 41(8): 1716-1725, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29288527

RESUMO

The analysis of topiramate in the presence of its main degradation products is challenging due to the absence of chromophore moieties and their wide range of polarity. Mixed-mode chromatography has been used in such cases because it combines two or more modes of separation. Charged aerosol detector is also an alternative since its detection is independent of optical properties and analyte ionization. This study is aimed to develop and validate two new stability-indicating methods by high-performance liquid chromatography for the main degradation products of topiramate using mixed-mode chromatography and a charged aerosol detector. Method 1 employed an Acclaim Trinity P1® column (3.0 mm × 150 mm, 2.7 µm) with a mobile phase comprising of 80% ammonium acetate buffer (20 mM, pH 4.0) and 20% methanol at a flow rate of 0.5 mL/min at 35°C. Method 2 utilized a C18 Acclaim 120® column (4.6 mm × 250 mm; 5 µm) with ACN/water (50:50) at a flow rate of 0.6 mL/min at 50°C. Validation of the two methods demonstrated excellent performance with respect to linearity, precision, accuracy, and selectivity. The limits of detection for topiramate, fructose, sulfate, sulfamate, and compound A were 2.97, 12.08, 4.02, 13.91, and 3.94 µg/mL, respectively.


Assuntos
Frutose/análogos & derivados , Aerossóis/química , Cromatografia Líquida de Alta Pressão , Frutose/análise , Estrutura Molecular , Topiramato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA