1.
J Am Coll Cardiol ; 76(25): 2940-2951, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33334422

RESUMO

BACKGROUND: Few studies have evaluated if diastolic function could predict outcomes in patients with aortic stenosis. OBJECTIVES: The authors aimed to assess the association between diastolic dysfunction (DD) and outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). METHODS: Baseline, 30-day, and 1- and 2-year transthoracic echocardiograms from the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registry were analyzed by a consortium of core laboratories and divided into the American Society of Echocardiography DD groups. RESULTS: Among the 1,750 included, 682 (54.4%) had grade 1 DD, 352 (28.1%) had grade 2 DD, 168 (13.4%) had grade 3 DD, and 51 (4.1%) had indeterminate DD grade. Incremental baseline grades of DD were associated with an increase in combined 1- and 2-year cardiovascular (CV) death/rehospitalization (all p < 0.002) and all-cause death at 2 years (p = 0.01) but not at 1 year. Improvement in DD grade/grade 1 DD at 30 days post-TAVR was seen in 70.8% patients. Patients with improvement in ≥1 grade of DD/grade 1 DD had reduced 1-year CV death/rehospitalization (p < 0.001) and increased 2-year survival (p = 0.01). Baseline grade 3 DD was a predictor of 1-year CV death/rehospitalization (hazard ratio: 2.73; 95% confidence interval: 1.07 to 6.98; p = 0.04). Improvement in DD grade/grade 1 DD at 30 days was protective for 1-year CV death/rehospitalizations (hazard ratio: 0.39; 95% confidence interval: 0.19 to 0.83; p = 0.01). CONCLUSIONS: In the PARTNER 2 SAPIEN 3 registry, baseline DD was a predictor of up to 2 years clinical outcomes in patients who underwent TAVR. Improvement in DD grade at 30 days was associated with improvement in short-term clinical outcomes. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128; PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - High Risk and Nested Registry 7 [PII S3HR/NR7]; NCT03222141).


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca Diastólica , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Canadá , Ecocardiografia/métodos , Ecocardiografia/estatística & dados numéricos , Feminino , Insuficiência Cardíaca Diastólica/diagnóstico , Insuficiência Cardíaca Diastólica/etiologia , Insuficiência Cardíaca Diastólica/fisiopatologia , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Prognóstico , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos
2.
Ann Thorac Surg ; 106(6): 1716-1725, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30153438

RESUMO

BACKGROUND: The incidence of leaflet thrombosis after transcatheter aortic valve replacement (TAVR) with active surveillance by four-dimensional computed tomography (4DCT) ranges from 7% to 14%. The incidence of leaflet thrombosis when 4DCT is performed for clinical and echocardiographic indications is unknown. METHODS: All patients with prior TAVR or surgical aortic valve replacement (SAVR) who underwent evaluation between October 2015 and January 2017 at our institution and had clinical or echocardiographic indications of leaflet thrombosis were evaluated by 4DCT. Indications for 4DCT by echocardiography included (1) interval increase in mean gradient of 10 mm Hg or more, (2) interval decrease in ejection fraction of 10% or more, (3) thrombus seen on transthoracic echocardiography, (4) persistent or increasing paravalvular leak, or (5) valve dehiscence or thickened leaflets seen on transthoracic echocardiography. Clinical indicators were (1) stroke, (2) transient ischemic attack, or (3) new or worsening heart failure. RESULTS: During the study period, 612 patients underwent TAVR, and 101 patients (55 TAVR; 46 SAVR) met the criteria for 4DCT imaging. Leaflet thrombosis was seen in 17 of 55 TAVR patients (30.9%) and 15 of 46 SAVR patients (32.6%). Follow-up imaging with 4DCT after treatment with anticoagulation showed improvement or resolution in thrombus burden and leaflet excursion in all TAVR patients and in two-thirds of SAVR patients. CONCLUSIONS: One-third of patients with clinical or echocardiographic indications suggestive of leaflet thrombosis were found to have evidence of leaflet thrombosis using 4DCT. This allowed tailored anticoagulation therapy with resolution of the thrombus in most patients and avoiding unnecessary anticoagulation in the remaining two-thirds of patients.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Tomografia Computadorizada Quadridimensional , Doenças das Valvas Cardíacas/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Trombose/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Humanos
3.
Proc (Bayl Univ Med Cent) ; 31(4): 414-418, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30948969

RESUMO

Cardiac computed tomography angiography (CCTA) is the gold standard for accurately sizing the aortic valve annulus prior to aortic valve replacement. A reduction of contrast volume administered for CCTA, without sacrificing image quality, is desirable. Signal-to-noise ratio represents final CCTA image quality. Consecutive patients referred to CCTA for aortic valve annulus sizing were retrospectively analyzed. Patients were grouped into a low-dose contrast (LDCT) group and traditional dose contrast (TDCT) group. In the LDCT group, contrast dose was <50% of the maximal allowable dose (3.7 × estimated glomerular filtration rate). Guided by a time-density curve, the contrast was administered in a two-stage infusion, and retrospectively gated images were acquired with a 64-multidetector computed tomography scanner. Out of 123 patients (age 80 ± 9 years; 46% female), 65 (52.9%) underwent LDCT and 58 (47.2%) underwent TDCT. Contrast volume was significantly lower in the LDCT group (LDCT 41.2 ± 9.8 vs TDCT 76.2 ± 14.2 mL; P < 0.001). The signal-to-noise ratio of the aortic root was 10.4 ± 4.1 for the LDCT group and 8.4 ± 3.3 for the TDCT group (P = 0.004). Aortic root dimensions could be measured in both LDCT and TDCT groups. In conclusion, LDCT with 64-slice CCTA can effectively size the aortic valve annulus to direct aortic valve replacement while offering reduced contrast exposure.

4.
Glob Cardiol Sci Pract ; 2017(2): 15, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29644227

RESUMO

A major concern regarding transcatheter aortic valve replacement (TAVR) is leaflet thrombosis. Four-dimensional computed tomography (4D-CT) is the preferred imaging modality to evaluate patients with suspected valve thrombosis. To date, the abnormal findings visualized by 4D-CT suggestive of leaflet thrombosis have lacked pathologic confirmation from a surgically explanted valve in a surviving patient. Herein, we provide pathologic confirmation of thrombus formation following surgical explantation of a thrombosed TAVR prosthesis that was initially identified by 4D-CT.

5.
Artigo em Inglês | MEDLINE | ID: mdl-28017714

RESUMO

OBJECTIVES: The aim of this study was to evaluate the long-term performance of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) through longitudinal echocardiographic analysis. BACKGROUND: The long-term performance of the SAPIEN TAVR is not well-described. Therefore, we examined the hemodynamic and valvular profile of the SAPIEN TAVR over 5 years. METHODS: All patients receiving TAVR or SAVR with first post-implant (FPI) and 5-year echoes were analyzed for aortic valve (AV) peak velocity, AV mean gradient, AV area, peak left ventricular (LV) outflow tract and in-stent velocities, Doppler velocity index, aortic regurgitation (AR), LV mass index, stroke volume index, and cardiac index. The FPI and 5-year data were compared using a paired t test or McNemar's analyses. RESULTS: There were 86 TAVR and 48 SAVR patients with paired FPI and 5-year echocardiograms. Baseline characteristics were similar between groups. The AV area did not change significantly 5 years after TAVR (p = 0.35). The AV mean gradient also remained stable: 11.5 ± 5.4 mm Hg at FPI to 11.0 ± 6.3 mm Hg at 5 years (p = 0.41). In contrast, the peak AV and LV outflow tract velocities decreased (p = 0.03 and p = 0.008, respectively), as did in-stent velocity (p = 0.015). Correspondingly, the TAVR Doppler velocity index was unchanged (p = 0.07). Among TAVR patients, there was no change in total AR (p = 0.40), transvalvular AR (p = 0.37), or paravalvular AR (p = 0.26). Stroke volume index and cardiac index remained stable (p = 0.16 and p = 0.25, respectively). However, there was a significant regression of LV mass index (p < 0.0001). The longitudinal evaluation among SAVR patients revealed similar trends. There was a low rate of adverse events among TAVR and SAVR patients alive at 5 years. CONCLUSIONS: Longitudinal assessment of the PARTNER I trial (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial) demonstrates that valve performance and cardiac hemodynamics are stable after implantation in both SAPIEN TAVR and SAVR in patients alive at 5 years. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894).

6.
J Clin Diagn Res ; 9(5): ZD21-2, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26155582

RESUMO

Nasopalatine duct cyst ( NPDC) is described as most common non-odontogenic developmental cyst of the jaws. Despite being common, its clinical and radiographic presentation could be varied and it can sometimes be a diagnostic challenge. This paper presents an unusual case of an infected NPDC associated with an impacted inverted mesiodens and a history of trauma that misled the clinical diagnosis.

7.
J Contemp Dent Pract ; 16(3): 215-21, 2015 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-26057921

RESUMO

AIM: Diabetes mellitus (DM) has become a global problem. By monitoring the health status of these individuals, diabetic complications can be prevented. We aimed to analyze alterations in the morphology and cytomorphometry of buccal epithelial cells of type 2 DM patients using oral exfoliative cytology technique and determine its importance in public health screening, diagnosis and monitoring of diabetes mellitus. MATERIALS AND METHODS: The study was carried out in 100 type 2 DM patients and 30 healthy individuals. Smears were taken from the right buccal mucosa and stained by the Papanicolaou technique. Staining with Acridine orange was carried out to view qualitative changes with confocal laser scanning microscope (LSM-510 Meta). The cytomorphometry was evaluated using IMAGE PRO PLUS 5.5 software with Evolution LC camera. All findings were statistically analyzed. RESULTS: The results showed that with increase in fasting plasma glucose levels, there is significant increase in nuclear area, decrease in cytoplasmic area, and increase in nuclear cytoplasmic ratio (p < 0.05) when compared to the control group. Various qualitative changes were noted, such as cell degeneration, micronuclei, binucleation, intracytoplasmic inclusion, candida and keratinization. CONCLUSION: In the present study, we found significant alterations in the cytomorphometry and cytomorphology of buccal epithelial cells of type 2 DM patients. This study supports and extends the view that these cellular changes can alert the clinician to the possibility of diabetes and aid in monitoring of diabetes throughout the lifetime of the patient.


Assuntos
Citodiagnóstico/métodos , Diabetes Mellitus Tipo 2/patologia , Mucosa Bucal/patologia , Laranja de Acridina , Glicemia/análise , Candida/isolamento & purificação , Morte Celular , Núcleo Celular/ultraestrutura , Citoplasma/ultraestrutura , Diabetes Mellitus Tipo 2/sangue , Células Epiteliais/patologia , Jejum , Corantes Fluorescentes , Humanos , Processamento de Imagem Assistida por Computador/métodos , Corpos de Inclusão/ultraestrutura , Queratinas , Programas de Rastreamento/métodos , Testes para Micronúcleos , Microscopia/métodos , Microscopia Confocal/métodos , Neutrófilos/patologia , Teste de Papanicolaou/métodos
8.
JACC Cardiovasc Imaging ; 8(3): 288-318, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25772835

RESUMO

Transcatheter aortic valve replacement (TAVR) using a balloon-expandable valve is an accepted alternative to surgical replacement for severe, symptomatic aortic stenosis in high risk or inoperable patients. Intraprocedural transesophageal echocardiography (TEE) offers real-time imaging guidance throughout the procedure and allows for rapid and accurate assessment of complications and procedural results. The value of intraprocedural TEE for TAVR will likely increase in the future as this procedure is performed in lower surgical risk patients, who also have lower risk for general anesthesia, but a greater expectation of optimal results with lower morbidity and mortality. This imaging compendium from the PARTNER (Placement of Aortic Transcatheter Valves) trials is intended to be a comprehensive compilation of intraprocedural complications imaged by intraprocedural TEE and diagnostic tools to anticipate and/or prevent their occurrence.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ultrassonografia de Intervenção/métodos , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Ensaios Clínicos como Assunto , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Cuidados Intraoperatórios , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
9.
J Am Soc Echocardiogr ; 28(2): 210-7.e1-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25455544

RESUMO

BACKGROUND: Inoperable aortic stenosis may be treated with either transcatheter aortic valve replacement (TAVR) or medical management (MM) with or without balloon aortic valvuloplasty (BAV). The aim of this study was to compare the long-term echocardiographic findings among TAVR, MM, and BAV in patients with severe, inoperable aortic stenosis. METHODS: A total of 358 inoperable patients in the Placement of Aortic Transcatheter Valves trial were randomized to MM or TAVR. Echocardiograms obtained at baseline, 30 days, and 1, 2, and 3 years were analyzed by a central core laboratory. RESULTS: At baseline, TAVR and MM were similar, with more frequent Society of Thoracic Surgeons score > 10 (51.7% vs 65.0%, P = .03) and larger end-systolic volumes (54.5 ± 29.3 vs 69.1 ± 48.0 mL, P = .03) in MM. By 30 days after TAVR, mean aortic valve gradient had decreased (from 43.8 ± 14.7 to 10.0 ± 4.3 mm Hg, P < .001), ejection fraction had increased (from 53.2 ± 12.4% to 56.7 ± 10.0%, P < .001), and left ventricular (LV) mass index had decreased (from 144.7 ± 36.1 to 140.0 ± 37.9 gm/m(2), P < .05). After 1 year, aortic valve gradients and area were unchanged, while LV mass index had decreased by another 16 gm/m(2) (to 124 gm/m(2)). By 30 days after BAV, mean aortic valve gradient had decreased from 43.4 ± 15.0 to 31.9 ± 11.1 mm Hg, while ejection fraction and LV mass index were unchanged; gradient reverted to baseline at 1 year. No changes in gradients or mass were seen in MM patients. CONCLUSIONS: TAVR results in immediate and sustained relief in pressure overload and improved LV systolic function, with continued regression of hypertrophy over 3 years. Poor clinical results with BAV are explained by the modest and transient reductions in pressure overload with BAV, which were not accompanied by improved LV function or remodeling. TAVR is the preferred treatment in eligible inoperable patients (ClinicalTrials.gov identifier NCT00530894).


Assuntos
Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/métodos , Estudos de Coortes , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Estudos Longitudinais , Masculino , Seleção de Pacientes , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Taxa de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
11.
J Oral Maxillofac Pathol ; 15(3): 326-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22144839

RESUMO

Juvenile ossifying fibroma is an uncommon, benign, bone-forming neoplasm with aggressive local growth that is distinguished from other fibro-osseous lesions primarily by its age of onset, clinical presentation and aggressive behavior. Although a benign entity, juvenile ossifying fibroma is known to be locally aggressive and has a high tendency to recur. Two distinctive microscopic patterns have been described: A trabecular variant and a psammomatoid variant. This latter variant is predominantly a craniofacial lesion and occurs rarely in the jaws. We present herein two cases of psammomatoid juvenile ossifying fibroma involving the jaws. The first case was a mandibular lesion in a 31-year-old female whereas the second case presented with maxillary involvement in a 46-year-old female. In addition, the pathology of the lesion was analyzed with confocal laser scanning microscopy.

12.
J Invasive Cardiol ; 22(2): 67-73, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20124591

RESUMO

BACKGROUND: The coronary sinus (CS) travels in close proximity to the left circumflex (LCX) artery. Percutaneously placed CS devices used to treat mitral regurgitation (MR) therefore have the potential to impinge upon the LCX arterial distribution and compromise coronary flow. OBJECTIVES: In this study, we sought to analyze the anatomic relationship between the CS, LCX and mitral annulus (MA) in patients with right dominant (RCD), left dominant (LCD) and codominant (CCD) arterial systems using a novel systematic approach. METHODS: We retrospectively studied 102 normal patients (46 females) and 27 consecutive patients (5 females) with ischemic severe MR. All patients underwent cardiovascular computed tomographic (CCT) angiography with a 64 multidetector scanner for clinical indications. Images were analyzed using a GE Advantage workstation, version 4.4, capable of advanced image processing and manipulation. RESULTS: In patients with a normal mitral valve, the LCX initially crossed under the coronary sinus/great cardiac vein (CS/GCV) in 74% with RCD, 83% with LCD and 97% with CCD. In patients with ischemic severe MR, the LCX initially crossed under the CS/GCV in 96%. CONCLUSIONS: The majority of patients, especially those with a CCD, have the LCX initially coursing under the CS/GCV. CCT data analysis using our newly established method is an excellent tool to evaluate the anatomic course of the LCX in patients being evaluated for percutaneous CS device placement.


Assuntos
Cateterismo/métodos , Seio Coronário/diagnóstico por imagem , Insuficiência da Valva Mitral , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Seio Coronário/anatomia & histologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/terapia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Isquemia Miocárdica/terapia , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA